Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Demand Response and Smart Buildings: A Survey of Control, Communication, and Cyber-Physical Security

In this paper, we perform a comprehensive survey of the technical aspects related to the implementation of demand response and smart buildings. Specifically, we discuss various smart loads such as heating, ventilating, and air-conditioning (HVAC) systems and plug-in electric vehicles (PEVs); the power architecture with multibus characteristics; different control algorithms such as the hybrid centralized and decentralized control and the distributed coordination among buildings; the communication technologies and network architectures; and the potential cyber-physical security issues and possible mechanisms for enhancing the system security at both cyber and physical layers. Finally, the current status of the demand response in United States, Europe, Japan, and China is reviewed, and the benefits, costs, and challenges of implementing and operating demand response and smart buildings are also discussed.

42 ENGINEERING↗

STS-49 Endeavour/Compiled Video for Editors

Compiled footage includes shots taken of the rollout of Endeavour at Palmdale, CA, the departure and arrival of Endeavour for Kennedy Space Center (KSC), main engine three installation, solid rocket booster (SRB) segment lift and stack at the Vehicle Assembly Building (VAB), external tank mate to SRB, Intelsat rotation at the Vertical Processing Facility (VPF), Endeavour rollover from the Orbiter Processing Facility (OPF) to VAB, rollout to Pad B, and the flight readiness firing (FRF). The crew is seen during the Terminal Countdown and Demonstration Test (TCDT) training activities, at breakfast, suiting up, and exiting the Operations and Checkout (O&C) Building.

Source record↗

Global Power System Transformation Consortium

The Global Power System Transformation (G-PST) Consortium, an expert- and practitioner-driven initiative, engages key power system operators, research and educational institutes, governments, businesses, and stakeholders in all regions of the world to accelerate clean energy transitions at the ambitious scope and scale that is required. The G-PST Consortium provides coordinated, holistic support and knowledge infusion for system operators pursuing clean energy transitions, including performing cutting-edge research; providing implementation support for world-class engineering and operational solutions; supporting workforce development; building and disseminating open-access data and tools; and accelerating localized technology adoption, standards development, and testing programs.

consortium↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

Recent Upgrades at the Safety and Tritium Applied Research Facility

This paper gives a brief overview of the Safety and Tritium Applied Research (STAR) facility operated by the Fusion Safety Program (FSP) at the Idaho National Laboratory (INL). FSP researchers use the STAR facility to carry out experiments in tritium permeation and retention in various fusion materials, including wall armor tile materials. FSP researchers also perform other experimentation as well to support safety assessment in fusion development. This lab, in its present two-building configuration, has been in operation for over ten years. The main experiments at STAR are briefly described. This paper discusses recent work to enhance personnel safety at the facility. The STAR facility is a Department of Energy less than hazard category 3 facility; the personnel safety approach calls for ventilation and tritium monitoring for radiation protection. The tritium areas of STAR have about 4 to 12 air changes per hour, with air flow being once through and then routed to the facility vent stack. Additional radiation monitoring has been installed to read the laboratory room air where experiments with tritium are conducted. These ion chambers and bubblers are used to verify that no significant tritium concentrations are present in the experiment rooms. Standby electrical power has been added to the facility exhaust blower so that proper ventilation will now operate during commercial power outages as well as the real-time tritium air monitors.

tritium facility upgrades↗

Acquisition of Kerr Dam and Establishment of a Wholesale Power Generation Corporation to Operate It: Hiring of Power market Coordinator and Staff Engineer (Final Report)

This project aimed at supporting one key component of a major multi-step undertaking on the part of the CSKT: the acquisition of the Kerr Hydroelectric project and its subsequent operation as a wholesale power generation facility. This project provided support to kick-start the development of the organizational structure to acquire and operate the facility by acquiring critical expertise necessary for the acquisition by funding in part two key personnel for the first two years of the four-year organizational development process. These individuals provided the Tribes with expert knowledge in the highly specialized areas of resource balancing, power marketing, and hydro-engineering; essential prerequisites to the Tribes' ability to build an organization for the operation of the Kerr Project and to securing financial backing for the acquisition. Goals achieved: • Establishing an efficient and economic conveyance process, and transition plans • Establishing an efficient and effective Tribal wholesale power generation corporation to manage the plant, balance the resources, and market the power from the Kerr Project. The success of this project, which is essential to the Tribes' acquisition of the Kerr Hydroelectric facility, helps to address poverty and unemployment among Tribal members by generating a number of highly skilled and specialized, high-paying Tribal member jobs and providing a stream of income from power sales that will be used for Tribal economic development. Objectives achieved: The project supported the position of Power Plant Operations and Maintenance engineer and power marketing coordinator positions. These are key, in part, to the Tribes' successful acquisition and operation of the facility because they will enable to the Tribes to gain the very specialized expertise required to operate a large wholesale power generation facility. Specific objectives include: Objective 1: Hire a power marketing coordinator to develop and coordinate the appropriate power marketing strategy for the sale of power generated by the operation of Kerr Dam. Objective 2: Hire a staff engineer.

13 HYDRO ENERGY↗

Wireless Pneumatic Thermostat Evaluation, Ronald Reagan Building and International Trade Center

To be effective at maintaining indoor air conditions, a building heating, ventilation, and air conditioning (HVAC) system needs to be controlled in some fashion. The control system needs to sense the temperature of a space, feeding it to a control system, and manipulate the HVAC equipment to maintain desired temperatures for the occupants. Within the portfolio of buildings under the jurisdiction, custody, or control of the General Services Administration (GSA), approximately 20% have HVAC systems that are operated by pneumatic control systems. These buildings are under the same energy conservation mandates as all federal facilities. Unfortunately, the major drawback to pneumatic systems is that they are not capable of implementing automated energy-saving control strategies. They can’t automatically change the thermostat setting at night and on weekends in the same way as more modern control systems such as direct digital controls (DDCs). Converting a building from a pneumatic control system to DDCs is typically cost prohibitive.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Temperature Heat Exchanger Design and Fabrication for Systems with Large Pressure Differentials

The project’s main purpose was to design, build and test a compact heat exchanger for supercritical carbon dioxide (sCO 2 ) power cycle recuperators. The compact recuperator is required to operate at high temperature and high pressure differentials, 169 bar (~2,500 psi), between streams of sCO 2 . Additional project tasks included building a hot air-to-sCO 2 Heater heat exchanger (HX) and design, build and operate a test loop to characterize the recuperator and heater heat exchangers. A novel counter-current microtube recuperator was built to meet the high temperature high differential pressure criteria and tested. The compact HX design also incorporated a number of features that optimize material use, improved reliability and reduced cost. The air-to-sCO 2 Heater HX utilized a cross flow, counter-current, micro-tubular design. This compact HX design was incorporated into the test loop and exceeded design expectations. The test loop design to characterize the prototype Brayton power cycle HXs was assembled, commissioned and operated during the program. Both the prototype recuperator and Heater HXs were characterized. Measured results for the recuperator confirmed the predictions of the heat transfer models developed during the project. Heater HX data analysis is ongoing.

20 FOSSIL-FUELED POWER PLANTS↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Material Selection and Sizing of a Thermoelectric Generator (TEG) for Power Generation in a Self-Powered Heating System

By employing the high temperature heat source to directly generate the electricity needed to power auxiliary systems in a natural gas furnace, boiler or hot water heater, a “self-powered” heating system can provide several benefits. Compared with a traditional furnace, boiler or hot water heater, when overall fuel utilization is kept constant, the self-powered system will have a higher primary energy efficiency, lower operating costs, and dramatically improved building safety and resilience during electric grid outages. Furthermore, a self-powered heating system only has a single utility connection – natural gas, without an electric connection – thus simplifying installation. A thermoelectric generator can be used for direct energy conversion of thermal energy to electricity with no moving parts, which offers a very simple means to provide power for the self-powered heating system, and the operation is without noise or vibration and can thus provide a very long system life. This paper provides an analysis focused on materials selection and the thermal power requirements for a thermoelectric generator (TEG) for use in a self-powered heating system. The dimensionless figure of merit for thermoelectric materials, zT, is used to estimate the optimal efficiency that can be achieved with a TEG to produce the electric power required in such an application. Comparisons of the predicted efficiency, the required heat transfer rate to the TEG and the heat transfer area needed for sustained operation under thermal conditions relevant to the self-powered heating application are made for several potential thermoelectric materials. This analysis was used to develop system requirements for a self-powered hot water heater using a TEG for electric power generation.

Laclair, Tim↗

Building-Wide, Adaptive Energy Management Systems for High-Performance Buildings: Final CRADA Report

Development and field demonstration of the minimum ratio policy for occupancy-driven, predictive control of outdoor air ventilation. Technology transfer of Argonne’s methods for occupancy estimation and forecasting and for M&V to BuildingIQ for their deployment. Selection of CO2 sensing as the currently best-available technology for occupancy-driven controls. Accelerated restart capability for the commercial BuildingIQ system using horizon shifting strategies applied to receding horizon optimal control problems. Empirical-based evidence of 30% chilled water energy savings and 22% total HVAC energy savings achievable with the BuildingIQ system operating in the APS Office Building on-site at Argonne.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Retail Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and Reducing Plug and Process Loads in Office Buildings (Brochure)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retail Buildings: Assessing and Reducing Plug and Process Loads in Retail Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in retail spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weather forecast-based optimization of integrated energy systems.

In this work, we establish an on-line optimization framework to exploit detailed weather forecast information in the operation of integrated energy systems, such as buildings and photovoltaic/wind hybrid systems. We first discuss how the use of traditional reactive operation strategies that neglect the future evolution of the ambient conditions can translate in high operating costs. To overcome this problem, we propose the use of a supervisory dynamic optimization strategy that can lead to more proactive and cost-effective operations. The strategy is based on the solution of a receding-horizon stochastic dynamic optimization problem. This permits the direct incorporation of economic objectives, statistical forecast information, and operational constraints. To obtain the weather forecast information, we employ a state-of-the-art forecasting model initialized with real meteorological data. The statistical ambient information is obtained from a set of realizations generated by the weather model executed in an operational setting. We present proof-of-concept simulation studies to demonstrate that the proposed framework can lead to significant savings (more than 18% reduction) in operating costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗