Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Theoretical Studies in Hadronic Physics and Fundamental Symmetries

The nucleons (protons and neutrons) are at the center of every atom, the fundamental building blocks of matter in our Universe. Their structure and properties have been actively studied at DOE’s Thomas Jefferson Lab as well as the future US electron-ion collider at Brookhaven National Lab, and are believed to be described by a mathematical theory known as quantum chromodynamics (QCD). In this project, the PI and collaborators invented a theoretical approach called “Generalized parton distributions through Universal Moment Parametrization” (GUMP) to construct the 3D structure of the nucleon from experimental data on Deeply virtual compton scattering and Deep-Exclusive meson production, and semi-inclusive jet or meson productions. The PI and collaborators have also explored the full power of a theory called the large- momentum effective theory (LaMET) to calculate the 3D structure of the nucleon from the first principles known as lattice QCD. In particular, the work paved the way for unprecedented precision calculations which are coming in next decade.

3D Structure↗

Nanoscale electrostatic control in ultraclean van der Waals heterostructures by local anodic oxidation of graphite gates

In an all-van der Waals heterostructure, the active layer, gate dielectrics and gate electrodes are assembled from two-dimensional crystals that have a low density of atomic defects. This design allows two-dimensional electron systems with very low disorder to be created, particularly in heterostructures where the active layer also has intrinsically low disorder, such as crystalline graphene layers or metal dichalcogenide heterobilayers. A key missing ingredient has been nanoscale electrostatic control, with existing methods for fabricated local gates typically introducing unwanted contamination. Here we describe a resist-free local anodic oxidation process for patterning sub-100 nm features in graphite gates, and their subsequent integration into an all-van der Waals heterostructure. We define a quantum point contact in the fractional quantum Hall regime as a benchmark device and observe signatures of chiral Luttinger liquid behaviour, indicating an absence of extrinsic scattering centres in the vicinity of the point contact. In the integer quantum Hall regime, we demonstrate in situ control of the edge confinement potential, a key requirement for the precision control of chiral edge states. In conclusion, this technique may enable the fabrication of devices capable of single anyon control and coherent edge-state interferometry in the fractional quantum Hall regime.

36 MATERIALS SCIENCE↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

Direct Aerobic Generation of a Ferric Hydroperoxo Intermediate Via a Preorganized Secondary Coordination Sphere

Enzymes exert control over the reactivity of metal centers with precise tuning of the secondary coordination sphere of active sites. One particularly elegant illustration of this principle is in the controlled delivery of proton and electron equivalents in order to activate abundant but kinetically inert oxidants such as O 2 for oxidative chemistry. Chemists have drawn inspiration from biology in designing molecular systems where the secondary coordination sphere can shuttle protons or electrons to substrates. However, a biomimetic activation of O 2 requires the transfer of both protons and electrons, and molecular systems where ancillary ligands are designed to provide both of these equivalents are comparatively rare. Here, we report the use of a dihydrazonopyrrole (DHP) ligand complexed to Fe to perform exactly such a biomimetic activation of O 2 . In the presence of O 2 , this complex directly generates a high spin Fe(III)-hydroperoxo intermediate which features a DHP• ligand radical via ligand-based transfer of an H atom. This system displays oxidative reactivity and ultimately releases hydrogen peroxide, providing insight on how secondary coordination sphere interactions influence the evolution of oxidizing intermediates in Fe-mediated aerobic oxidations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Attitude stability of LDEF: Refinement of results from the silver pinhole camera

A measurement was previously described of the angular offset and attitude stability of the LDEF spacecraft using a simple pinhole camera device in the UAH experiment A0114. This device uses a silver surface to record the impact zone of atmospheric atomic oxygen passing through a small pinhole on the front surface of the satellite. The shape and size of this zone are well defined if the satellite velocity and gas temperature are known. The circular symmetry of the zone would be distorted by oscillation of the LDEF about its stable attitude, or by the effect of the co-rotation of the Earth's atmosphere for cases of satellites in nonequatorial orbits. The observed ellipticity of 1.05 with the major axis in the yaw direction is equivalent to an oscillation of + or - 0.2 deg about the stable attitude. The uncertainty in that measurement was estimated at about 0.1 deg. A refined analysis based on summing distributions of flux versus incidence angle for a large number of orbital positions, and including a co-rotating atmosphere, indicates that the combined distributions produce a result consistent with the measured exposed spot. It is suggested that, within the precision of the measurements, no actual oscillation of the LDEF is required to produce the results. Thus, the LDEF may have maintained a stable attitude to better than 0.1 deg, even under conditions of maximum aerodynamic perturbation when the silver oxygen record was made. This error is some two orders of magnitude lower than the predicted uncertainty in yaw oscillation and may indicate that the predict methodologies are too conservative.

Peters, P. N.↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Identification of $^{3}$He–$^{3}$H clusters in the $^{6}$Li+$^{89}$Y experiment using particle-$\gamma$ coincidence measurement

The 6 Li+ 89 Y experiment was performed to explore the reaction mechanism induced by a weakly bound nucleus 6 Li and its cluster configuration. Here, the particle-$\gamma$ coincidence method was used to identify the different reaction channels. The $\gamma$-rays coincident with 3 He/ 3 H indicate that the 3 H/ 3 He stripping reaction plays a significant role in the formation of Zr/Nb isotopes. The obtained results support the existence of a 3 He- 3 H cluster in 6 Li. Direct and sequential transfer reactions are adequately discussed, and the FRESCO code is used to perform precise finite-range cyclic redundancy check calculations. In the microscopic calculation, direct cluster transfer is more predominant than sequential transfer in 3 H transfer. However, the direct cluster transfer is of comparable magnitude to the sequential transfer in the 3 He transfer.

CRC calculations↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

Using Fourier-Plane Imaging Microscopy for Determining Transition-Dipole-Moment Orientations in Organic Light-Emitting Devices

Here, we use Fourier-plane imaging microscopy (FIM) to determine the transition-dipole-moment orientation in doped organic emissive thin films. The use of FIM enables precise, sensitive, and rapid measurement of dipole orientation in the emission layer of an organic light-emitting device (OLED). An optical model of a stratified birefringent multilayer is introduced for interpreting results obtained by FIM. Using the model, we determine the average orientation of transition-dipole-moment vectors of three phosphorescent dopant emitters. The dipole alignment measured by FIM quantitatively explains the difference in OLED efficiencies using these archetype dopant molecules. FIM provides a nondestructive tool to measure and ultimately improve the outcoupling efficiency of OLEDs and other light-emitting devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

No Escaping Helium from 55 Cnc e

We search for escaping helium from the hot super-Earth 55 Cnc e by taking high-resolution spectra of the 1083 nm line during two transits using Keck/NIRSPEC. We detect no helium absorption down to a 90% upper limit of 250 ppm in excess absorption or 0.27 mÅ in equivalent width. This corresponds to a mass-loss rate of less than ∼10{sup 9} g s{sup −1} assuming a Parker wind model with a plausible exosphere temperature of 5000–6000 K, although the precise constraint is heavily dependent on model assumptions. We consider both hydrogen- and helium-dominated atmospheric compositions and find similar bounds on the mass-loss rate in both scenarios. Our hydrodynamical models indicate that if a lightweight atmosphere exists on 55 Cnc e, our observations would have easily detected it. Together with the nondetection of Lyα absorption by Ehrenreich et al., our helium nondetection indicates that 55 Cnc e either never accreted a primordial atmosphere in the first place or lost its primordial atmosphere shortly after the dissipation of the gas disk.

74 ATOMIC AND MOLECULAR PHYSICS↗

Components in interstellar molecular hydrogen

Results are reported for precise spectrophotometric measurements of the profiles of selected Lyman absorption lines produced by hydrogen molecules in various rotational levels along the line of sight to 13 stars which have shown some evidence for an increase in line width with increasing rotational quantum number (J). The line profiles were measured by multiple scans with the Copernicus satellite telescope. Based on analysis of the radial velocities, derivations of the column densities, and line-profile fitting, the following conclusions are made: (1) the increase in interstellar H2 line width with increasing J results from the presence of the most shortward component, which is relatively weak at low J but becomes more important at higher J; (2) the relative column densities found for the different J levels in each component may be fitted by a theoretical model in which rotational excitation is due to absorption of UV photons followed by radiative quadrupole spontaneous transitions or collisionally induced downward transitions between different J levels; (3) the atomic hydrogen density is between 300 and 1000 per cu cm in the most shortward component for each of three stars; (4) the approaching gas which produces each shortward component must be in the form of thin sheets; and (5) the sheets are the compressed gas behind a shock front moving through the interstellar medium.

Spitzer, L., Jr.↗

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

Temperature Control of Crystal Optics for Ultrahigh-Resolution Applications

The temperature control of crystal optics is critical for ultrahigh resolution applications such as those used in meV-resolved Inelastic Scattering. Due to the low count rate and long acquisition time of these experiments, for 1-meV energy resolution, the absolute temperature stability of the crystal optics must be maintained below 4 mK to ensure the required stability of lattice constant, thereby ensuring the energy stability of the optics. Furthermore, the temperature control with sub-mK precision enables setting the absolute temperature of individual crystal, making it possible to align the reflection energy of each crystal’s rocking curve in sub-meV resolution thereby maximizing the combined efficiency of the crystal optics. In this contribution, we report the details of an EPICS control system using PT1000 sensors, Keithley 3706A 7.5 digits sensor scanner, and Wiener MPOD LV power supply for the analyzer crystals of the Inelastic X-ray Scattering (IXS) beamline 10-ID at NSLS-II**. We were able to achieve absolute temperature stability below 1 mK and sub-meV energy alignment for several asymmetrically cut analyzer crystals. The EPICS ePID record was used for the control of the power supplies based on the PT1000 sensor input that was read with 7.5 digits accuracy from the Keithley 3706A scanner. The system enhances the performance of the meV-resolved IXS spectrometer with currently a 1.4 meV total energy resolution and unprecedented spectral sharpness for studies of atomic dynamics in a broad range of materials.

Gofron, Kaz↗

Autonomous Synthesis of Metastable Materials Using a Modular Mixed-Flow Reactor

Understanding and controlling atomic-level processes at solid-liquid interfaces is key to advancing technologies in energy storage, carbon capture, critical element recovery, and materials synthesis. Many of these processes are dominated by the formation of short-lived intermediate precipitates that determine the final properties of synthesized materials. However, studying these intermediates is challenging due to their sensitivity and the reliance on trial-and-error methods. To address this, we developed an automated variable-volume mixed-flow reactor (MFR) to optimize metastable material synthesis and investigate rapid kinetic processes. This state-of-the-art MFR system, paired with an automated modeling framework, enables efficient synthesis and real-time analysis of transient phases. Benchmarking with advanced capabilities, such as wide-/small-angle X-ray scattering, allows us to resolve fast nucleation and growth dynamics that were previously inaccessible. By combining automation, ML-guided optimization, and tailored kinetic modeling, this approach provides a robust platform for improving material design and achieving precise control over solid-liquid reactions.

36 MATERIALS SCIENCE↗