Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waveforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Nonlinear Resonant Oscillations of Gas in Optimized Acoustical Resonators and the Effect of Central Blockage

Optimizing resonator shapes for maximizing the ratio of maximum to minimum gas pressure at an end of the resonator is investigated numerically. It is well known that the resonant frequencies and the nonlinear standing waveform in an acoustical resonator strongly depend on the resonator geometry. A quasi-Newton type scheme was used to find optimized axisymmetric resonator shapes achieving the maximum pressure compression ratio with an acceleration of constant amplitude. The acoustical field was solved using a one-dimensional model, and the resonance frequency shift and hysteresis effects were obtained through an automation scheme based on continuation method. Results are presented for optimizing three types of geometry: a cone, a horn-cone and a half cosine- shape. For each type, different optimized shapes were found when starting with different initial guesses. Further, the one-dimensional model was modified to study the effect of an axisymmetric central blockage on the nonlinear standing wave.

Li, Xiao-Fan↗

More Far-Side Deep Moonquake Nests Discovered

As reported last year, we started to reanalyze the seismic data acquired from 1969 to 1977 with a network of stations established on the Moon during the Apollo mission. The reason for the reanalysis was because recent advances in computer technology make it possible to employ much more sophisticated analysis techniques than was possible previously. The primary objective of the reanalysis was to search for deep moonquakes on the far side of the Moon and, if found, to use them to infer the structure of the Moon's deep interior, including a possible central core. The first step was to identify any new deep moonquakes that escaped our earlier search by applying a combination of waveform cross-correlation and single-link cluster analysis, and then to see if any of them are from previously unknown nests of deep moonquakes. We positively identified 7245 deep moonquakes, more than a five-fold increase from the previous 1360. We also found at least 88 previously unknown deep-moonquake nests. The question was whether any of these newly discovered nets were on the far side of the Moon, and we now report that our analysis of the data indicates that some of them are indeed on the far side.

Nakamura, Y.↗

Solar Arrays for Direct-Drive Electric Propulsion: Arcing at High Voltages

The results from an experimental investigation to assess arcing during operation of high voltage solar arrays in a plasma environment are presented. The experiments were part of an effort to develop systems that would allow safe operation of Hall-Effect Thrustefls) in direct-drive mode. Arc discharges are generated when the array is biased negative with respect to the plasma. If sustained for long periods of time between adjacent solar cells, arcs may severely damage a solar array, thus significantly shortening its lifetime. Most often sustained arcs are triggered by plasma produced during short-duration discharge arcs (approximately 20 microseconds). These trigger arcs are sparked between the semiconducting cell and the covering dielectric. Both trigger and sustained (greater than 1 millisecond) arcs have been captured during the tests. Current and voltage waveforms associated with the different arc events are presented. The test results have defined operational limits (thresholds) for the various array concepts studied that minimize the likelihood of damage from sustained arcs. Experimental trends regarding the effect of the solar array substrate on arc duration are also presented.

Schneider, Todd A.↗

LASTRAC.3d: Transition Prediction in 3D Boundary Layers

Langley Stability and Transition Analysis Code (LASTRAC) is a general-purpose, physics-based transition prediction code released by NASA for laminar flow control studies and transition research. This paper describes the LASTRAC extension to general three-dimensional (3D) boundary layers such as finite swept wings, cones, or bodies at an angle of attack. The stability problem is formulated by using a body-fitted nonorthogonal curvilinear coordinate system constructed on the body surface. The nonorthogonal coordinate system offers a variety of marching paths and spanwise waveforms. In the extreme case of an infinite swept wing boundary layer, marching with a nonorthogonal coordinate produces identical solutions to those obtained with an orthogonal coordinate system using the earlier release of LASTRAC. Several methods to formulate the 3D parabolized stability equations (PSE) are discussed. A surface-marching procedure akin to that for 3D boundary layer equations may be used to solve the 3D parabolized disturbance equations. On the other hand, the local line-marching PSE method, formulated as an easy extension from its 2D counterpart and capable of handling the spanwise mean flow and disturbance variation, offers an alternative. A linear stability theory or parabolized stability equations based N-factor analysis carried out along the streamline direction with a fixed wavelength and downstream-varying spanwise direction constitutes an efficient engineering approach to study instability wave evolution in a 3D boundary layer. The surface-marching PSE method enables a consistent treatment of the disturbance evolution along both streamwise and spanwise directions but requires more stringent initial conditions. Both PSE methods and the traditional LST approach are implemented in the LASTRAC.3d code. Several test cases for tapered or finite swept wings and cones at an angle of attack are discussed.

Chang, Chau-Lyan↗

Reflections of AE Waves in Finite Plates: Finite Element Modeling and Experimental Measurements

The capability of a three-dimensional dynamic finite element method for predicting far-field acoustic emission signals in thin plates of finite lateral extent, including their reflections from the plate edges, was investigated. A lead break (Hsu-Neilsen) source to simulate AE was modeled and used in the experimental measurements. For the thin plate studied, the signals were primarily composed of the lowest order symmetric (S0) and antisymmetric (A0) Lamb modes. Experimental waveforms were detected with an absolutely calibrated, wideband, conical element transducer. The conditions of lead fractures both on the surface of the plate as well as on the edge of the plate were investigated. Surface lead breaks preferentially generate the A0 mode while edge lead breaks generate the S0 mode. Reflections of developed plate waves from both normal and oblique incidence angles were evaluated. Particularly interesting for the case of the lead break on the plate edge were S0 waves produced by the interaction of a Rayleigh wave with the plate corner and by a bulk shear wave mode converting at the side edge. The Rayleigh wave, in this case, propagated along the specimen edge. For all cases considered, the experimental measurements were in good agreement with the predictions of the finite element model.

Prosser, W. H.↗

Human Response to Simulated Low-Intensity Sonic Booms

NASA's High Speed Research (HSR ) program in the 1990s was intended to develop a technology base for a future High-Speed Civil Transport (HSCT). As part of this program, the NASA Langley Research Center sonic boom simulator (SBS) was built and used for a series of tests on subjective response to sonic booms. At the end of the HSR program, an HSCT was deemed impractical, but since then interest in supersonic flight has reawakened, this time focusing on a smaller aircraft suitable for a business jet. To respond to this interest, the Langley sonic boom simulator has been refurbished. The upgraded computer-controlled playback system is based on an SGI O2 computer, in place of the previous DEC MicroVAX. As the frequency response of the booth is not flat, an equalization filter is required. Because of the changes made during the renovation (new loudspeakers), the previous equalization filter no longer performed as well as before, so a new equalization filter has been designed. Booms to be presented in the booth are preprocessed using the filter. When the preprocessed signals are presented into the booth and measured with a microphone, the results are very similar to the intended shapes. Signals with short rise times and sharp "corners" are observed to have a small amount of "ringing" in the response. During the HSR program a considerable number of subjective tests were completed in the SBS. A summary of that research is given in Leatherwood et al. (Individual reports are available at http://techreports.larc.nasa.gov/ltrs/ltrs.html.) Topics of study included shaped sonic booms, asymmetrical booms, realistic (recorded) boom waveforms, indoor and outdoor booms shapes, among other factors. One conclusion of that research was that a loudness metric, like the Stevens Perceived Level (PL), predicted human reaction much more accurately than overpressure or unweighted sound pressure level. Structural vibration and rattle were not included in these studies.

Sullivan, Brenda M.↗

MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

NASA Discipline Cardiopulmonary↗

Speech motor control and acute mountain sickness

BACKGROUND: An objective method that accurately quantifies the severity of Acute Mountain Sickness (AMS) symptoms is needed to enable more reliable evaluation of altitude acclimatization and testing of potentially beneficial interventions. HYPOTHESIS: Changes in human articulation, as quantified by timed variations in acoustic waveforms of specific spoken words (voice onset time; VOT), are correlated with the severity of AMS. METHODS: Fifteen volunteers were exposed to a simulated altitude of 4300 m (446 mm Hg) in a hypobaric chamber for 48 h. Speech motor control was determined from digitally recorded and analyzed timing patterns of 30 different monosyllabic words characterized as voiced and unvoiced, and as labial, alveolar, or velar. The Environmental Symptoms Questionnaire (ESQ) was used to assess AMS. RESULTS: Significant AMS symptoms occurred after 4 h, peaked at 16 h, and returned toward baseline after 48 h. Labial VOTs were shorter after 4 and 39 h of exposure; velar VOTs were altered only after 4 h; and there were no changes in alveolar VOTs. The duration of vowel sounds was increased after 4 h of exposure and returned to normal thereafter. Only 1 of 15 subjects did not increase vowel time after 4 h of exposure. The 39-h labial (p = 0.009) and velar (p = 0.037) voiced-unvoiced timed separations consonants and the symptoms of AMS were significantly correlated. CONCLUSIONS: Two objective measures of speech production were affected by exposure to 4300 m altitude and correlated with AMS severity. Alterations in speech production may represent an objective measure of AMS and central vulnerability to hypoxia.

NASA Discipline Space Human Factors↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

Relationship between early diastolic intraventricular pressure gradients, an index of elastic recoil, and improvements in systolic and diastolic function

BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.

Non-NASA Center↗

Intracranial pressure dynamics during simulated microgravity using a new noninvasive ultrasonic technique

It is believed that intracranial pressure (ICP) may be elevated in microgravity because a fluid shift toward the head occurs due to loss of gravitational blood pressures. Elevated ICP may contribute to space adaptation syndrome, because as widely observed in clinical settings, elevated ICP causes headache, nausea, and projectile vomiting, which are similar to symptoms of space adaptation syndrome. However, the hypothesis that ICP is altered in microgravity is difficult to test because of the invasiveness of currently-available techniques. We have developed a new ultrasonic technique, which allows us to record ICP waveforms noninvasively. The present study was designed to understand postural effects on ICP and assess the feasibility of our new device in future flight experiments.

NASA Center ARC↗

On the precision of automated activation time estimation

We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.

NASA Discipline Cardiopulmonary↗

Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

NASA Discipline Cardiopulmonary↗

A new technique to determine the correlation between the QT interval and heart-rate for control and SIDS babies

The ability of the autonomic nervous system to alter the QT interval in response to heart rate changes is essential to cardiovascular control. An accurate way to determine the relation between QT intervals and their corresponding RR intervals is described. A computer algorithm measures the RR intervals using digital filtering and cross-correlating the QRS sections of consecutive waveforms. The QT intervals is calculated by choosing a section of, the ECG that includes the T wave and cross-correlating it with all the consecutive T waves. At least 4000 pairs of QT-RR intervals are computed for each subject and a best fit correlation function determines the relations between the QT and RR intervals. This technique enables to establish a precise correlation between RR and QT in order to distinguish between control and SIDS babies.

Non-NASA Center↗

The use of in-flight foot pressure as a countermeasure to neuromuscular degradation

The purpose of this study was to determine whether applying foot pressure to unrestrained subjects during space flight could enhance the neuromuscular activation associated with rapid arm movements. Four men performed unilateral arm raises while wearing--or not wearing--specially designed boots during a 81- or 115-day space flight. Arm acceleration and surface EMG were obtained from selected lower limb and trunk muscles. Pearson r coefficients were used to evaluate similarity in phasic patterns between the two in-flight conditions. In-flight data also were magnitude normalized to the mean voltage value of the muscle activation waveforms obtained during the no-foot-pressure condition to facilitate comparison of activation amplitude between the two in-flight conditions. Foot pressure enhanced neuromuscular activation and somewhat modified the phasic features of the neuromuscular activation during the arm raises.

Mir Project↗

Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.

Seale, Michael D.↗

Advanced AE Techniques in Composite Materials Research

Advanced, waveform based acoustic emission (AE) techniques have been successfully used to evaluate damage mechanisms in laboratory testing of composite coupons. An example is presented in which the initiation of transverse matrix cracking was monitored. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite specimens or structures, the effects of modal wave propagation over larger distances and through structural complexities must be well characterized and understood. To demonstrate these effects, measurements of the far field, peak amplitude attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels are discussed. These measurements demonstrated that the flexural mode attenuation is dominated by dispersion effects. Thus, it is significantly affected by the thickness of the composite plate. Furthermore, the flexural mode attenuation can be significantly larger than that of the extensional mode even though its peak amplitude consists of much lower frequency components.

Prosser, William H.↗

High Voltage Solar Array Arc Testing for a Direct Drive Hall Effect Thruster System

The deleterious effects of spacecraft charging are well known, particularly when the charging leads to arc events. The damage that results from arcing can severely reduce system lifetime and even cause critical system failures. On a primary spacecraft system such as a solar array, there is very little tolerance for arcing. Motivated by these concerns, an experimental investigation was undertaken to determine arc thresholds for a high voltage (200-500 V) solar array in a plasma environment. The investigation was in support of a NASA program to develop a Direct Drive Hall-Effect Thruster (D2HET) system. By directly coupling the solar array to a Hall-effect thruster, the D2HET program seeks to reduce mass, cost and complexity commonly associated with the power processing in conventional power systems. In the investigation, multiple solar array technologies and configurations were tested. The cell samples were biased to a negative voltage, with an applied potential difference between them, to imitate possible scenarios in solar array strings that could lead to damaging arcs. The samples were tested in an environment that emulated a low-energy, HET-induced plasma. Short duration trigger arcs as well as long duration sustained arcs were generated. Typical current and voltage waveforms associated with the arc events are presented. Arc thresholds are also defined in terms of voltage, current and power. The data will be used to propose a new, high-voltage (greater than 300 V) solar array design for which the likelihood of damage from arcing is minimal.

Schneider, Todd↗