Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

AmeriFlux FLUXNET-1F US-Hsm Hill Slough Marsh

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Hsm Hill Slough Marsh. This is the FLUXNET version of the carbon flux data for the site US-Hsm Hill Slough Marsh produced by applying the standard ONEFlux (1F) software. Site Description - The site is currently a diked marsh - upland ecotone located at the northern Suisun Marsh. It will undergo tidal restoration in Fall 2021. Restoration work is done by Ducks Unlimited Inc. and will cover an area of 649 acres. After levee breaches, the site tower will be in a high marsh system. Water level at high tide is estimated to be 0.5-1 m above the soil. Ducks Unlimited, Inc. and the Berkeley Biometeorology lab are working together to evaluate the effects of the proposed tidal marsh restoration project.

Kyle_Delwiche, Kyle_Delwiche [University of Califo↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances in Process Intensification through Multifunctional Reactor Engineering

This project was designed to advance the art of process intensification leading to a new generation of multifunctional chemical reactors utilizing pulse flow. Experimental testing was performed in order to fully characterize the hydrodynamic operating regimes associated with pulse flow for implementation in commercial applications. Sandia National Laboratories (SNL) operated a pilot-scale multifunctional reactor experiment for operation with and investigation of pulse flow operation. Validation-quality data sets of the fluid dynamics, heat and mass transfer, and chemical kinetics were acquired and shared with Chemical Research and Licensing (CR&L). Experiments in a two-phase air-water system examined the effects of bead diameter in the packing, and viscosity. Pressure signals were used to detect pulsing. Three-phase experiments used immiscible organic and aqueous liquids, and air or nitrogen as the gas phase. Hydrodynamic studies of flow regimes and holdup were performed for different types of packing, and mass transfer measurements were performed for a woven packing. These studies substantiated the improvements in mass transfer anticipated for pulse flow in multifunctional reactors for the acid-catalyzed C4 paraffin/olefin alkylation process. CR&L developed packings for this alkylation process, utilizing their alkylation process pilot facilities in Pasadena, TX. These packings were evaluated in the pilot-scale multifunctional reactor experiments established by Sandia to develop a more fundamental understanding of their role in process intensification. Lummus utilized the alkylation technology developed by CR&L to design and optimize the full commercial process utilizing multifunctional reactors containing the packings developed by CR&L and evaluated by Sandia. This hydrodynamic information has been developed for multifunctional chemical reactors utilizing pulse flow, for the acid-catalyzed C4 paraffin/olefin alkylation process, and is now accessible for use in other technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in Process Intensification through Multifunctional Reactor Engineering

This project was designed to advance the art of process intensification leading to a new generation of multifunctional chemical reactors utilizing pulse flow. Experimental testing was performed in order to fully characterize the hydrodynamic operating regimes associated with pulse flow for implementation in commercial applications. Sandia National Laboratories (SNL) operated a pilot-scale multifunctional reactor experiment for operation with and investigation of pulse flow operation. Validation-quality data sets of the fluid dynamics, heat and mass transfer, and chemical kinetics were acquired and shared with Chemical Research and Licensing (CR&L). Experiments in a two-phase air-water system examined the effects of bead diameter in the packing, and viscosity. Pressure signals were used to detect pulsing. Three-phase experiments used immiscible organic and aqueous liquids, and air or nitrogen as the gas phase. Hydrodynamic studies of flow regimes and holdup were performed for different types of packing, and mass transfer measurements were performed for a woven packing. These studies substantiated the improvements in mass transfer anticipated for pulse flow in multifunctional reactors for the acid-catalyzed C4 paraffin/olefin alkylation process. CR&L developed packings for this alkylation process, utilizing their alkylation process pilot facilities in Pasadena, TX. These packings were evaluated in the pilot-scale multifunctional reactor experiments established by Sandia to develop a more fundamental understanding of their role in process intensification. Lummus utilized the alkylation technology developed by CR&L to design and optimize the full commercial process utilizing multifunctional reactors containing the packings developed by CR&L and evaluated by Sandia. This hydrodynamic information has been developed for multifunctional chemical reactors utilizing pulse flow, for the acid-catalyzed C4 paraffin/olefin alkylation process, and is now accessible for use in other technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development Status of PROTEUS-MOC

The PROTEUS-MOC solver is intended to resolve the outstanding computational challenges that the PROTEUS-SN is limited by and bridge the gap between PROTEUS-SN and existing homogenized structured grid solvers. The primary push behind all of this work is to carry out coupled thermal-mechanical, fluid dynamics, and neutronics physics problems. The PROTEUS-MOC development has taken advantage of the combined experience with PROTEUS-SN and DeCART with the goal of producing a tool which combines the best features of both tools. Taking the DeCART tool as the model, it merges a subgroup cross section interpolation technique with a 2D method of characteristics approach and a 1D SN formulation. DeCART has been specifically demonstrated to be accurate on PWR and VHTR problems, but it has displayed several issues with regard to accuracy on thin axial mesh sizes which are attributable to the 2D1D scheme it is built upon. There are also notable problems with performance and scalability all of which we hope to resolve in PROTEUS-MOC. PROTEUS-MOC is at its core, based upon the success achieved with MOCFE which demonstrated excellent parallelization with respect to angle and good parallelization with respect to space. More recent efforts have indicated parallelization with respect to energy is also feasible. The work completed yielded a novel methodology where the axial basis functions are treated separately from the radial ones, but the geometry is extruded. This eliminates the need to carry out and store 3D ray tracing data and simultaneously allows the coarse axial node sizes typical with DeCART. To rapidly build a prototype, a standard power iteration algorithm was constructed using an unpreconditioned GMRES solution algorithm for solving the flux vector in each fission source iteration. The new PROTEUS-MOC solver was deployed on two test problems: Takeda and a heterogeneous cylindrical heavy water system. The Takeda benchmark problem is a standard homogeneous test problem which was previously found to be too difficult for the 3D MOCFE code to solve. Using the PROTEUS-MOC we were able to show space-angle convergence although full convergence requires further improvements in performance. The second benchmark problem was constructed more for future work than this year, but the results generated are promising indicating that it will be very useful in highlighting the weaknesses and strengths of the PROTEUS-MOC tool. While we are far from a production tool, the results included in this report give us confidence that we are on the right path to constructing an interceding code between the plethora of structured grid homogenized assembly solvers and the supercomputer consuming PROTEUS-SN code. With time, the creation of a suitable preconditioner along with typical optimization should reduce the performance shortcomings that are observable today.

Marin-Lafleche, A.↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation Framework and Analyses for Thermal Energy Storage Integrated with Packaged Air Conditioning

Few third-party guidance documents or tools are available for evaluating thermal energy storage (TES) integrated with packaged air conditioning (AC), as this type of TES is relatively new compared to TES integrated with chillers or hot water systems. To address this gap, researchers at the National Renewable Energy Laboratory conducted a project to improve the ability of potential technology adopters to evaluate TES technologies. Major project outcomes included: development of an evaluation framework to describe key metrics, methodologies, and issues to consider when assessing the performance of TES systems integrated with packaged AC; application of multiple concepts from the evaluation framework to analyze performance data from four demonstration sites; and production of a new simulation capability that enables modeling of TES integrated with packaged AC in EnergyPlus. This report includes the evaluation framework and analysis results from the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nevada National Security Site Integrated Groundwater Sampling Plan, Revision 0

The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collection and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.

54 ENVIRONMENTAL SCIENCES↗

Annual Report of Monitoring at Morrill, Kansas, in 2012

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the public water supply wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha (Figure 1.1). The population of Morrill as of the 2010 Census was approximately 230 (down from 277 in 2000). All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. This document reports the findings concerning the groundwater in Morrill.

54 ENVIRONMENTAL SCIENCES↗

Annual Report of Monitoring at Morrill, Kansas, in 2013

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the public water supply wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha (Figure 1.1). The population of Morrill as of the 2010 Census was approximately 230 (down from 277 in 2000). All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. Because the identified carbon tetrachloride contamination in groundwater could potentially be linked, in part, to historical use of carbon tetrachloride-based fumigants at its former facility, in 2003 the CCC/USDA assumed responsibility for investigation of the carbon tetrachloride contamination. The CCC/USDA involvement began with development and implementation of a work plan for a Phase I expedited site characterization. That investigation and subsequent investigations were performed by the Environmental Science Division of Argonne National Laboratory. The initial investigation by the CCC/USDA in 2003 determined that soils at the former facility were not impacted by grain fumigation activities. Neither carbon tetrachloride nor chloroform (the primary degradation product of carbon tetrachloride) was detected in nearsurface soils or in subsurface soils collected to bedrock. Because no identifiable human health risk was associated with either carbon tetrachloride or chloroform in shallow soils, the conclusion was that no further threat of contamination to groundwater was present. In September 2005, the CCC/USDA initiated periodic sampling of groundwater, in accord with a program approved by the KDHE (2005), to monitor carbon tetrachloride concentrations in the groundwater. The report presents the data generated during the 2013 monitoring period.

54 ENVIRONMENTAL SCIENCES↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HPC - Facilities Penta

Strategy, Planning, Acquiring- very large scale computing require very large physical infrastructures, pipes, pumps, power, etc. Planning and acquiring $25M+ infrastructure projects and bringing in more power to the county takes a lot of long lead time / planning. Integration- New physical infrastructure must be integrated into our buildings, with the LANL site power and water systems, with existing infrastructure, and with the machines. Very large physical infrastructure projects are necessary. Management and Utilization – Ongoing operations, monitoring, maintenance, and trouble shooting of the physical infrastructure is required.

Computer Hardware↗

A Critical Review of the Impacts of Leaking CO 2 Gas and Brine on Groundwater Quality

Geological carbon sequestration (GCS) is a global carbon emission reduction strategy involving the capture of CO 2 emitted from fossil fuel burning power plants, as well as the subsequent injection of the captured CO 2 gas into deep saline aquifers or depleted oil and gas reservoirs. A critical question that arises from the proposed GCS is the potential impacts of CO 2 injection on the quality of drinking-water systems overlying CO 2 sequestration storage sites. Although storage reservoirs are evaluated and selected based on their ability to safely and securely store emplaced fluids, leakage of CO 2 from storage reservoirs is a primary risk factor and potential barrier to the widespread acceptance of geologic CO 2 sequestration (OR Harvey et al. 2013; Y-S Jun et al. 2013; DOE 2007). Therefore, a systematic understanding of how CO 2 leakage would affect the geochemistry of potable aquifers, and subsequently control or affect elemental and contaminant release via sequential and/or simultaneous abiotic and biotic processes and reactions is vital.

54 ENVIRONMENTAL SCIENCES↗

Chapter 14: Chiller Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This protocol defines a chiller measure as a project that directly impacts equipment within the boundary of a chiller plant. A chiller plant encompasses a chiller - or multiple chillers - and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water system components.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Project Closeout Report for the MFC Firewater Replacement Project

The Material and Fuels Complex (MFC) Firewater Replacement Project was an indirectly funded Institutional General Plant Project (IGPP) capital acquisition initiated in July 2013 and completed in June 2016. Its purpose was to improve the capacity, redundancy and reliability of the MFC fire water and potable water systems, making them compliant with DOE O 420.1C and applicable state and federal regulations.

99 GENERAL AND MISCELLANEOUS↗

Annual Report of Monitoring at Morrill, Kansas, in 2017 (TR-18-04)

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the public wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha (Figure 1.1). The population of Morrill as of the 2010 Census was approximately 230 (down from 277 in 2000). All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991.

54 ENVIRONMENTAL SCIENCES↗

Summary of RF Technology Program Activities, October 2013 - September 2017

The goals of the National RF Research and Development Program (NRRDP) are to advance the basic understanding of high-power radio frequency (RF) in a plasma environment, and to maintain the high-power transmitters and cooling water systems required to support the ITER Ion Cylcotron Range of Frequencies (ICRF) transmission line high power component testing and operation of the Proto-Material Plasma Exposure eXperiment (MPEX) device. The work includes the study of the RF sheath, and development of RF-related diagnostics. These include active and passive spectroscopic diagnostics that can provide local and line integrated measurements of RF and Direct Current (DC) electric fields in the edge plasma of fusion devices, as well as measurements of other parameters. One of these, the Doppler Free Saturation Spectroscopy (DFSS) diagnostic, utilizes a laser beam split into two intersecting, counter-propagating pump and probe beams, whose intersection defines the measurement region. DFSS has demonstrated measurements of atomic spectra with 500 times greater resolution than passive Optical Emission Spectroscopy (OES). This allows Stark effect based electric field measurements to be made with two orders of magnitude high sensitivity than with OES. Measurements have been made using an ORNL electron-cyclotron resonant (ECR) plasma source producing densities up to 10 19 m -3 , in the vicinity of an RF-biased planar electrode.

47 OTHER INSTRUMENTATION↗

Fundamental Science of Doping and Defects in Ga 2 O 3 for Next Generation Power Semiconductors

The aim and scope of this project was the development of a capability to prepare high-quality, epitaxial beta gallium oxide films by oxide reactive molecular-beam epitaxy. The purpose was to demonstrate that beta gallium oxide could be grown by such a method using Sandia’s existing oxide molecular-beam epitaxy instrument. The key activity in this project was the installation of a gallium oxide capability on the Sandia instrument. This required the acquisition of several custom items for the instrument, including: a gallium effusion cell, appropriate cell power supplies and temperature controllers, a shutter to block beam flux, installation of an existing ozone generator with a directed gas nozzle and controlled leak valve, and re-routing the chilled water system to accommodate the cell. In addition, beta gallium oxide single crystals were acquired and their surfaces characterized by reflection high energy electron diffraction.