Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waste Forms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Crucible Melter Simulation in Nek5000

Nuclear tank waste at the Hanford site is slated for vitrification in large scale refractory-lined melters to transform it into a stable borosilicate waste form suitable for long-term storage or disposal. Molten glass corrodes the refractory lining over time at a rate correlated to the velocity of molten glass against the refractory-lined wall. To properly design a melter and plan for maintenance, it is necessary to accurately model the glass flow and find the correlation between flow velocity and corrosion rate. This modeling was started in STAR-CCM+ CFD software and is being continued in Nek5000 for its fast-running and quick turnaround code. This poster explains the basic process of reconstructing the geometry, fluid properties, and heating of test melters in Nek5000. The geometry is imported from a mesh file and boundary conditions assigned based on surface IDs. The fluid properties are set in the .par and .usr case files. The heating of the actual crucibles in joule heating with electrodes but simulated in Nek5000 with a volumetric heat source term. This volumetric heat source is fit to the actual heating profile with piecewise polynomials and exponentials. Basic results and verification methods are explained in the poster, as well as further work that must be done to complete modeling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determine Minimum Silver Flake Addition to GCM for Iodine Loaded AgZ

The minimum amount of silver flake required to prevent loss of I{sub 2} during sintering in air for a SNL Glass Composite Material (GCM) Waste Form containing AgI-MOR (ORNL, 8.7 wt%) was determined to be 1.1 wt% Ag. The final GCM composition prior to sintering was 20 wt% AgI-MOR, 1.1 wt% Ag, and 80 wt% Bi-Si oxide glass. The amount of silver flake needed to suppress iodine loss was determined using thermo gravimetric analysis with mass spectroscopic off-gas analysis. These studies found that the ratio of silver to AgI-MOR required is lower in the presence of the glass than without it. Therefore an additional benefit of the GCM is that it serves to inhibit some iodine loss during processing. Alternatively, heating the AgI-MOR in inert atmosphere instead of air allowed for densified GCM formation without I{sub 2} loss, and no necessity for the addition of Ag. The cause of this behavior is found to be related to the oxidation of the metallic Ag to Ag{sup +} when heated to above ~300{degrees}C in air. Heating rate, iodine loading levels and atmosphere are the important variables that determine AgI migration and results suggest that AgI may be completely incorporated into the mordenite structure by the 550{degrees}C sintering temperature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium E h values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9.3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-1 and Table ES-2, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2017 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various conditions. To accomplish this, an IDF PA glass dissolution model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon solution concentrations, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the ion exchange process. The effect of temperature, pH, H4SiO4 activity, and the rate of ion exchange can be parameterized and implemented directly into the PA rate model. The rate model parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. The provided data can be used by glass researchers to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate model parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a Zirconium Recycle Scrubber System

A hot-cell demonstration of the zirconium recycle process is planned as part of the Materials Recovery and Waste Forms Development (MRWFD) campaign. The process treats Zircaloy® cladding recovered from used nuclear fuel with chlorine gas to recover the zirconium as volatile ZrCl4. This releases radioactive tritium trapped in the alloy, converting it to volatile tritium chloride (TCl). To meet regulatory requirements governing radioactive emissions from nuclear fuel treatment operations, the capture and retention of a portion of this TCl may be required prior to discharge of the off-gas stream to the environment. In addition to demonstrating tritium removal from a synthetic zirconium recycle off-gas stream, the recovery and quantification of tritium may refine estimates of the amount of tritium present in the Zircaloy cladding of used nuclear fuel. To support these objectives, a bubbler-type scrubber was fabricated to remove the TCl from the zirconium recycle off-gas stream. The scrubber was fabricated from glass and polymer components that are resistant to chlorine and hydrochloric acid solutions. Because of concerns that the scrubber efficiency is not quantitative, tests were performed using DCl as a stand-in to experimentally measure the scrubbing efficiency of this unit. Scrubbing efficiency was ~108% ± 3% with water as the scrubber solution. Variations were noted when 1 M NaOH scrub solution was used, values ranged from 64% to 130%. The reason for the variations is not known. It is recommended that the equipment be operated with water as the scrubbing solution. Scrubbing efficiency is estimated at 100%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary report for the FY-2015 SACSESS Collaboration

During FY-2015, a collaborative research program was established by the Department of Energy-Nuclear Energy (DOE-NE) Material Recovery and Waste Form Development program and the European Union (EU) Safety of Actinide Separation Processes (SACSESS) program. One component of this collaboration was the evaluation of the radiolytic stability of a Selective ActiNide Extraction (SANEX) separation which utilized a TODGA-based organic solvent and an aqueous phase containing the hydrophilic complexing reagent, SO3-Ph-BTP. To best simulate process conditions, this experiment was irradiated in the radiolysis/hydrolysis test loop located at the Idaho National Laboratory. The effect of irradiation on a SACSESS program iSANEX formulation containing a TODGA-based organic phase and a BTP-based aqueous phase was investigated using irradiations at INL in static and test loop modes. When irradiated in contact with only the acidic aqueous phase, the TODGA organic solution maintained excellent extraction performance of americium, cerium and europium to a maximum absorbed dose of nearly 0.9 MGy. When the aqueous phase was changed to that containing the aqueous soluble BTP, the irradiated aqueous phase showed a dramatic color change, but this does not appear to have adverse effects on solvent extraction performance. Only minor increases in distribution ratios for both the lanthanides and actinide were measured, and the separation factors were essentially unchanged to a maximum absorbed dose of 174 kGy. The determination of the americium, cerium, and europium distribution ratios for the remaining SACSESS test loop samples will be completed in the near future. The analysis of stable metals concentration in the the irradiated aqueous and organic phases will be completed shortly.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Characterization of Underwater Radioactive Sludge

A fundamental requirement underpinning safe clean-up technologies for legacy spent nuclear fuel (SNF) ponds, pools and wet silos is the ability to characterize the radioactive waste form prior to retrieval. The corrosion products resulting from the long term underwater storage of spent nuclear fuel, reactor components and reprocessing debris present a major hazard to facility decontamination and decommissioning in terms of their radioactive content and physical / chemical reactivity. The ability to perform in-situ underwater non-destructive characterization of sludge and debris in a safe and cost-effective manner offers significant benefits over traditional destructive sampling methods. Several techniques are available for underwater measurements including (i) Gross gamma counting, (ii) Low-, Medium- and High- Resolution Gamma Spectroscopy, (iii) Passive neutron counting and (iv) Active Neutron Interrogation. The optimum technique depends on (i) the radioactive inventory (ii) mechanical access restrictions for deployment of the detection equipment, interrogation sources etc. (iii) the integrity of plant records and (iv) the extent to which Acceptable Knowledge which may be used for 'fingerprinting' the radioactive contents to a marker nuclide. Prior deployments of underwater SNF characterization equipment around the world have been reviewed with respect to recent developments in gamma and neutron detection technologies, digital electronics advancements, data transfer techniques, remote operation capabilities and improved field ruggedization. Modeling and experimental work has been performed to determine the capabilities, performance envelope and operational limitations of the future generation of non-destructive underwater sludge characterization techniques. Recommendations are given on the optimal design of systems and procedures to provide an acceptable level of confidence in the characterization of residual sludge content of legacy wet storage facilities such that retrieval and repackaging of SNF sludges may proceed safely and efficiently with support of the regulators and the public. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Evaluation of Accelerated Basin De-Inventory Material Addition to Sludge Batch 11 (Rev. 1)

The Accelerated Basin De-inventory (ABD) program involves discarding spent nuclear fuel that is currently stored in L-Basin to the Defense Waste Processing Facility (DWPF) for vitrification. The first ABD discards will occur during the preparation of Sludge Batch (SB) 11. Savannah River Mission Completion has requested that the Savannah River National Laboratory assess the technical gaps related to the increased gadolinium poisoning requirement and the impacts of performing the Low Temperature Aluminum Dissolution (LTAD) process in Tank 51 with H-Canyon discards present. The following summarizes the evaluation of the impacts of increasing the quantity of gadolinium (and related topics) from what was previously evaluated in the SRNL studies of gadolinium-poisoned ABD material solubility, the overall ABD flowsheet review, and increasing the fissile mass loading in glass: 1) Based on literature surveys, there is no indication that organic interactions with gadolinium will be significant at the high pH (typically >13) conditions of the Concentration, Storage, and Transfer Facilities. Any interactions of gadolinium with organics in DWPF are not expected to adversely impact DWPF or downstream facilities. Thus, there is little-to-no residual risk from organic interactions with gadolinium [Gap closed]; 2) Adding depleted uranium to ABD material, targeting 235 U enrichment of 4.90% within each transfer window, will mitigate potential impacts from an increase in soluble 235 U enrichment during sludge washing and LTAD. The plan to take advantage of previous transfers and allow 235 U enrichment of >5% during the final transfer window carries a risk that Tank 51 supernate will have a 235 U enrichment of >5%, which should be evaluated for acceptance; 3) Increasing the gadolinium mass ratio to 3.0:1 Gd: 235 U(eq SLU ) should lead to the same or higher partitioning of gadolinium into the solid phase within the DWPF Chemical Process Cell, resulting in both liquid and solid phases with expected partitioning of Gd consistent with the prior solubility study [Gap closed for SB11]; 4) There are no expected impacts on DWPF melt temperature and melter operations due to the minimal ~0.2 weight percent (wt%) increase in Gd concentration relative to previous sludge batches [Gap closed for SB11]; 5) As observed previously, Gd is expected to enter the off-gas system via physical entrainment, but at a slightly higher concentration than what was observed for SB9 melter off-gas pluggage deposits (0.07 wt%) [Gap closed for SB11] ; 6) There are no expected impacts on DWPF recycle or the Recycle Collection Tank glycolate destruction process. [Gap closed for SB11]; 7) Gd is projected to be a trace component in the SB11 glass (<0.5 wt%) and can be ignored for process control. Trace components do not significantly impact glass durability, thus the conclusions of the previous Product Consistency Test evaluation at a fissile mass loading of 2,500 g fissile/m3 glass still applies to SB11. The ~0.1 wt% increase in Gd2O3 concentration relative to the previous study will not impact the predictability of SB11 glass with the DWPF Product Composition Control System (PCCS) models for durability or the acceptability of glass according to the Waste Acceptance Product Specifications (WAPS) criterion for product consistency [Gap closed for SB11]; 8) No additional Toxicity Characteristic Leaching Procedure testing is necessary for SB11 and the hazardous waste specification of the SB11 DWPF waste form is unchanged after the addition of the ABD stream [Gap closed for SB11]. The following summarizes the evaluation of the impacts of adding two-thirds of the ABD material to Tank 51 prior to LTAD: 1) The addition of two-thirds of the ABD increases overall aluminum mass from 1.39×10 4 kg to 1.64×10 4 kg (15.5% ABD Al). The form of the insoluble portion of the Al resulting from ABD addition should be the more readily dissolved Al(OH) 3 and amorphous forms. The portion of the ABD aluminum that is processed by LTAD is expected to be completely soluble, thus requiring that less of the boehmite in the sludge be dissolved to reach the same Al target in the SB. [Gap closed for SB11]; The expected LTAD impact on other components, as related primarily to the components in ABD, are discussed. Gd is expected to remain insoluble during LTAD and not impact the solubility of other components. [Gap closed for SB11]; The addition of two-thirds of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 13,100 kg (63% ABD U) and the projected plutonium mass from 86.0 kg to 89.5 kg (3.9% ABD Pu). The addition of all of the ABD increases overall projected SB11 uranium mass from 4,740 kg to 16,100 kg (70% ABD U) and the projected plutonium mass from 86.0 kg to 90.4 kg (5.3% ABD Pu). The 235 U enrichment will be ≤5%. The fissile uranium will be adequately poisoned by Gd and the fissile Pu will be adequately poisoned by Fe from the sludge. [Gap closed for SB11]; There is a low risk that ABD addition will impact the rheology or pumpability of the slurry. There is a low but higher risk of ABD addition prior to LTAD impacting the settling rate; Based on the evaluation of adding two-thirds of the ABD material and all of the ABD material prior to the LTAD process, there is no volume or mass limit that would need to be imposed on ABD additions prior to LTAD. [Gap closed for SB11]. Revision 1 of this report addresses a variation on the ABD additions and LTAD strategy where sodium hydroxide additions for LTAD may be performed intermittently or concurrently with an ABD addition window. The proposed change does not alter the conclusions of this evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Distribution During Evaporation of Hanford Waste Treatment Plant Direct Feed Low Activity Waste Effluent Management Facility Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream from the off-gas system. The baseline plan for disposition of this stream during full WTP operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation, and recycled to the LAW vitrification facility. However, during the Direct Feed LAW (DFLAW) scenario, planned disposition of this stream involves concentrating the condensate in a new evaporator at the Effluent Management Facility (EMF) and returning it to the LAW melter. The LAW melter condensate stream will contain components, e.g. halides and sulfates, that are volatile at melter temperatures, have limited solubility in glass waste forms, and present a material corrosion concern. Further, some minor constituents in the melter condensate, such as volatile organic compounds and iodine, have been found to be at least partially volatile in the EMF. The condensate from the EMF will be sent to the Hanford Effluent Treatment Facility (ETF). The presence of some recalcitrant organics and iodine, as 129I, are expected to be problematic in the ETF. In order to better predict and prepare for the distribution of organics and 129I in the flowsheet, it is key to understand their chemistry and experimentally determine their behavior during evaporation. To do this, modeling and testing were performed to examine the speciation of iodine under relevant conditions, as well as determine partitioning of iodine and the organics in the EMF evaporator. This overall program examines the potential treatment and immobilization of the LAW melter condensate stream to enable alternative disposal. The objective of this task was to (1) perform modeling to determine the speciation and fate of iodine species, (2) prepare a simulant of the LAW Melter Off-gas Condensate expected during DFLAW operations, (3) spike in the key volatile organics and non-radioactive iodine, and (4) demonstrate evaporation in order to predict the final composition of the effluents from the EMF evaporator to aid in planning for their disposition. The results of the modeling of iodine speciation indicate that the iodine is expected to remain in the evaporator pot as iodide and possibly iodate ion if the pH is raised to 11.5-12, which is the planned condition for the EMF. Experimental testing confirmed that the iodide remained in the evaporator concentrate and was below detection limits in all condensate and knock-out pot samples, indicating it was not volatile. The organic nitrile compounds that were added to the simulant were absent from the evaporator feed solution, either lost through evaporation, or more likely, decomposition. The acetone and methylene chloride were below the target values in the feed and condensate samples, and were presumably lost to evaporation or decomposition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Impact of Thin Pours on Saltstone Properties

The proposed Saltstone Disposal Unit 6 (SDU6) is a larger structure than the SDU4 cells and larger than the disposal units (SDU2, SDU3, and SDU5) currently in use or under construction. The additional capacity provided by SDU6 is desired to reduce life cycle costs and support site accelerated closure goals. The larger size of the planned SDU6 could result in saltstone being placed in thinner lifts as the unit is filled. This study was performed to determine whether thinner layers of saltstone negatively impact the performance of the waste form. A larger number of cold joints could potentially result in increased drying, salt deposition, and surface oxidation. A matrix of samples was prepared to simulate thin pours ranging from 0.5 to 6 inches thick. Each sample was cured for at least 28 days prior to further characterization. Leachability results showed that there is no obvious impact of the number of grout layers on the Leachability Index values for Na and NO 3 . The concentrations of Cr, NO 2 , and C 2 O 4 were below detection limits for all of the leachates. No attempt was made to evaluate the oxidation of these samples since no measureable Cr was leached, although this would appear to indicate that Cr in the samples remained reduced for cold joints with surfaces exposed for approximately four days. The results of hydraulic conductivity measurements showed that the number of cold joints in the samples did not have a significant impact on the measured values for the vertical lift orientation (i.e., when the flow path is perpendicular to the cold joints). For the horizontal lift orientation (i.e., when the flow path is parallel to the cold joints), the number of cold joints in the samples also did not appear to have a significant impact on hydraulic conductivity. The measured hydraulic conductivity was faster when the flow path was parallel to the cold joints as compared to when the flow path was perpendicular to the cold joints. Percolation testing showed increased flow when the number of cold joints was increased. Compressive strength testing showed that the maximum load at the onset of cracking was reduced by approximately 26% for those samples that contained cold joints as compared to the monolithic samples. The number of cold joints in the sample had no significant impact on the maximum load prior to cracking. The porosity of the samples was not influenced by cold joints. This result was expected as the porosity is a material property affected by the properties of the components (premix and salt solution) and the water to premix ratio. Overall, the only obvious impact of cold joints in the samples was to significantly increase hydraulic conductivity in the direction parallel to the cold joints. An increasing number of cold joints (thin layers) in the simulated saltstone samples did not exacerbate this effect, nor did it have a negative impact on the Leachability Indices or porosity for surfaces exposed for approximately four days. The presence of a cold joint reduced the compressive strength of the material, although this impact was seen regardless of the number of cold joints in the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cadmium Chemical Form in Mine Waste Materials by X-ray Absorption Spectroscopy

This study examines the molecular form of cadmium (Cd) present in mine wastes by X-ray Absorption Spectroscopy (XAS; Cd>20 mg/kg) using the K-edge of Cd at the Photon Factory Advanced Ring (PF-AR), NW10A beam line at KEK-Tsukuba-Japan. Mine waste materials and zinc concentrate were analyzed for Cd by ICPMS prior to undertaking XAS (range 21-452 mg/kg). Model compounds (CdO, Cd(OH){sub 2}, CdCO{sub 3}, Cdacetate, CdS, Cdstearate, CdDEDTC) and samples were examined in solid form at 20 K. The XANES spectra showed similar E max values for both model compounds and samples. The EXAFS showed that Cd-S in CdS, gives a flatter spectrum in the extended region compared to Cd-O found with CdCO{sub 3}, CdO and Cd Stearate. Linear combination fitting with model Cd compounds did not give clear assignments of composition, indicating that more detailed EXAFS spectra is required as mineral forms containing Cd were present rather than simple Cd compounds such as CdCO{sub 3}. The Cd bond for a single shell model in mine waste sample matrices appears to be either Cd-O or Cd-S, or a combination of both. Comparison of molecular data from the XAS studies with bioaccessibility data giving a prediction of bioavailability for mine waste materials provides useful information about the significance of the cadmium form as a contaminant for health risk assessment purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Glasses for Immobilizing Lanthanide, Alkali, and Alkali-earth Fission Products

A series of glasses were formulated for the immobilization of a potential waste stream from commercial nuclear fuel reprocessing, the combined lanthanide (LN), alkali, and alkaline earth (Cs/Sr) fission products. These glasses were formulated to meet repository disposal requirements while being processable in a cold-crucible melter. The glasses were fabricated and tested for product consistency test response, phase characterization, density, and glass transition temperature. The results suggest that the combined fission product waste forms are likely to meet repository requirements and generate less glass than if individual streams were vitrified.

Crum, Jarrod V↗

Asymmetric Lattice Disorder Induced at Oxide Interfaces

Control of order-disorder phase transitions is a fundamental materials science challenge, underpinning the development of energy storage technologies such as solid oxide fuel cells and batteries, ultra-high temperature ceramics, and durable nuclear waste forms. At present, the development of promising complex oxides for these applications is hindered by a poor understanding of how interfaces affect lattice disordering processes and defect transport. Here we explore the evolution of local disorder in ion-irradiated La 2 Ti 2 O 7 /SrTiO 3 thin film heterostructures using a combination of high-resolution scanning transmission electron microscopy (STEM), position-averaged convergent beam electron diffraction (PACBED), electron energy loss spectroscopy (STEM-EELS), and ab initio theory calculations. We observe highly non-uniform lattice disordering driven by asymmetric oxygen vacancy formation across the interface. Our calculations indicate that this asymmetry results from differences in the polyhedral connectivity and vacancy formation energies of the two interface components, suggesting ways to manipulate lattice disorder in functional oxide heterostructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NanoSIMS Imaging Alternation Layers of a Leached SON68 Glass Via A FIB-made Wedged Crater

Currently, nuclear wastes are commonly immobilized into glasses because of their long-term durability. Exposure to water for long periods of time, however, will eventually corrode the waste form and is the leading potential avenue for radionuclide release into the environment. Because such slow processes cannot be experimentally tested, the prediction of release requires a thorough understanding the mechanisms governing glass corrosion. In addition, due to the exceptional durability of glass, much of the testing must be performed on high-surface-area powders. A technique that can provide accurate compositional profiles with very precise depth resolution for non-flat samples would be a major benefit to the field. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling is an excellent tool that has long been used to examine corrosion layers of glass. The roughness of the buried corrosion layers, however, causes the corresponding SIMS depth profiles to exhibit erroneously wide interfaces. In this study, NanoSIMS was used to image the cross-section of the corrosion layers of a leached SON68 glass sample. A wedged crater was prepared by a focused ion beam (FIB) instrument to obtain a 5× improvement in depth resolution for NanoSIMS measurements. This increase in resolution allowed us to confirm that the breakdown of the silica glass network is further from the pristine glass than a second dissolution front for boron, another glass former. The existence of these two distinct interfaces, separated by only ~20 nm distance in depth, was not apparent by traditional ToF-SIMS depth profiling but has been confirmed also by atom probe tomography. This novel sample geometry will be a major benefit to efficient NanoSIMS sampling of irregular interfaces at the nanometer scale that would otherwise be obscured within ToF-SIMS depth profiles.

Environmental Molecular Sciences Laboratory↗

An exploration of benchtop X–ray emission spectroscopy for precise characterization of the sulfur redox state in cementitious materials

The evolution of sulfur chemistry in cements is best known in the bailiwick of failure mechanisms via sulfate attack but is equally important for its contributions to the reduction capacity of cementitious materials often used for immobilizing nuclear waste streams destined for long-term storage, e.g., cementitious waste forms (CWF). The total reduction capacity of CWFs, encompassing contributions from both S and Fe reductants, and its implications toward radionuclide immobilization is most often studied by destructive wet chemistry methods requiring acid digestion in the presence of Ce(IV) and subsequent titration and colorimetric interpretation. Here, we investigate a similarly analytical but nondestructive alternative, benchtop high resolution wavelength-dispersive x-ray fluorescence spectroscopy, most commonly known as x-ray emission spectroscopy (XES), for probing the bulk sulfur oxidation state distribution. We present here an initial investigation of S XES, including an improved experimental protocol for lab XES of inhomogeneous samples, both as a complement to the Ce(IV) test and for new scientific opportunities that it enables for observing changes in sulfur chemistry. We discuss future improvements and opportunities, including: (1) the practical challenges associated with coordinating XES and Ce(IV) liquid extraction for a more comprehensive perspective on reduction capacity and for a high-precision evaluation of uncertainties in the Ce(IV) test; and (2) new opportunities, due to the nondestructive nature of XES, for controlled evolution studies aimed at elucidating specific chemical responses of CWF’s exposed to invasive gas or liquid species or to accelerated aging by radiative dose or thermal treatment.

36 MATERIALS SCIENCE↗

Effects of Copolymer Structure on Enzyme-Catalyzed Polyester Recycling

Polyesters are an omnipresent material used for a variety of applications (e.g., bottles, packaging, textile, windshield), roughly comprising 8% of plastics produced worldwide. Enzymatic recycling is an emerging solution to deal with the increasingly diverse polyesters that are not suitable for mechanical recycling. However, enzyme activity and efficiency are still the limiting factors impeding enzymatic recycling for different plastic waste forms. The effects of thermal and structural properties (e.g., glass transition temperature, crystallinity, specific surface area), which are determined by chemical composition and preprocessing, directly influence enzyme recycling efficiency. This work investigates two extrusion methods (single screw and twin-screw extrusion) to pretreat a range of copolyesters (RPET, PETG, Ecozen, Tritan and PBT) and modify their properties (i.e., glass transition temperature (T g ), crystallinity (%), and molecular weight (M n )). A PET-specific enzyme, leaf-branch compost cutinase (LCC ICCG ), produced from a fed-batch fermentation of Escherichia coli BL21(DE3), was used for the enzymatic depolymerization of different polyesters. Several copolyesters showed improved depolymerization after pretreatment, as measured by rate and amount of monomers produced. Furthermore, those that did not depolymerize were found to have exceptionally high glass transition temperature or percent crystallinity, highlighting the importance of these physical parameters on conversion efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗