Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Ford Thermoelectric HVAC Project (Final Report)

Current light-duty vehicles provide passenger thermal comfort primarily through the use of a centralized HVAC (Heating, Ventilation, and Air Conditioning) unit that distributes conditioned air to vent locations throughout the vehicle. A substantial portion of the air energy content is spent conditioning various elements of the vehicle's interior structures. This is not an overwhelming issue in today’s vehicles, but as pressure builds to improve powertrain efficiency, the energy available to provide occupant comfort will decrease. Thermoelectric devices were identified by the US Department of Energy as one method to potentially reduce HVAC-related energy consumption in vehicles. The objective of the Ford Thermoelectric HVAC Project was to identify a technical and business approach to accelerate research and development of light-duty automotive thermoelectric HVAC technology. A zonal HVAC system was developed to provide thermal comfort to each occupant, with the objective of reducing the overall power consumed by the HVAC system compared with a baseline system. The system was designed to provide a basis for a down-sized central HVAC unit, while providing equivalent comfort and equivalent heating/cooling time-to-comfort at startup, and reduce the energy consumed to provide these functions. Project success was evaluated using occupant comfort and energy consumption metrics, based on a novel thermal comfort-modeling approach, and empirical testing. The ability to produce and market the thermoelectric devices developed in this program was assessed by a business analysis that outlined key steps required for thermoelectric HVAC devices to come to market. Key hardware and controls attribute requirements were identified to determine how they contribute to the commercialization potential of the technology. Final testing and analysis showed that use of thermal comfort and zonal design criteria reduced the energy consumption of the climate control system in both heating and cooling tests, and were significantly better in low vehicle occupancy cases where zonal strategies could be employed. Thermoelectric devices were utilized in the vehicle design to support achieving the technical performance goals of the project. It was found that these devices need additional development in order to address commercial issues, due to their cost and performance limitations.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Hydrogen Gas Generation and Permeation in the 9979 Type AF Shipping Package

The 9979 Type AF Shipping Packaging is a cost-effective radioactive material package designed by Savannah River National Laboratory (SRNL) that consists of two primary components: a foamed outer drum for structural protection and an inner containment drum. The packaging was designed to transport Highly Enriched Uranium (HEU), Low Enriched Uranium (LEU), and other isotopes not exceeding a Type A quantity. These contents have the potential to generate flammable hydrogen gas during transport due to the degradation of hydrogenous materials (e.g. water vapor, plastics, etc) by high-energy alpha radiation. Since 10 CFR 71.43(h) prohibits the incorporation of packaging features explicitly designed for continuous venting, alternative justification was required to demonstrate that the requirements of 10 CFR 71.43(d) for negligible reactions between packaging components and contents were satisfied. An analysis was performed to demonstrate that the potential for hydrogen gas generation over a one-year period was limited by the effects of permeation through the packaging materials. The rate of hydrogen collection was evaluated for both the inner containment drum and the outer structural drum under 10 CFR 71.71 Normal Conditions of Transport (NCT). The analysis concludes that the Lower Flammability Limit (LFL) for hydrogen gas will not be reached in a one-year shipping period assuming a minimum void volume is maintained within the drum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 Corrosion Evaluation Plan

Nuclear material packages, with few exceptions, outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging. The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology Inc. (NFT Inc.) as a general purpose vented manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex. The SAVY-4000 containers have a 316L stainless steel containment barrier, which was selected based on its corrosion resistant properties. These containers were approved for use in 2014 with a five-year design life; LANL requested and DOE has approved lifetime extension from 5 to 15 years. The 10-year lifetime extension was proposed as a conservative recommendation based on the corrosion observations for the metal components in surveillance and results from laboratory studies. Extensive accelerated aging studies have been done on the SAVY-4000 O-ring with very little evidence of significant degradation when subjected to aggressive elevated temperature and radiation conditions. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 40 years at 80°C. Additional work is ongoing in a phased approach to further extend the design life of the Manual compliant SAVY-4000 storage container; the limiting component for further life extension is still the 316L containment barrier.

36 MATERIALS SCIENCE↗

Gen3CSP sCO2 Loop Scope of Supply (V0.0.3)

The Generation 3 Concentrating Solar Power (Gen3CSP) supercritical carbon dioxide (sCO 2 ) coolant loop, typically referred to here as the `sCO 2 loop,' is designed to continuously remove heat from a primary heat exchanger (PHX) subsystem through a flow of sCO 2 as a substitute for a sCO 2 Brayton power cycle as shown in Figure 1-1. This system is designed to function as a pumped coolant loop operating at a high baseline pressure with a high degree of flexibility, stability, and autonomy to simplify operation of a Gen3CSP Topic 1 team Phase 3 pilot plant. The complete system includes a dedicated inventory management module to fill the main flow loop with CO2 and recovery CO2 during heating and venting operations to minimize the delivery of CO2 to the site.

20 FOSSIL-FUELED POWER PLANTS↗

Survey of existing and emerging power conversion technologies relevant to a self-powered furnace

Furnaces for residential space heating consume about 2.5% of all annual primary energy consumed in the US. Conventional furnaces utilize electricity from the electric grid to power blowers and other components. A self-powered furnace would utilize fuel energy to generate its own power, while rejecting the waste heat from the power cycle to provide additional useful building heating. Assuming the total energy use remains the same as for a conventional furnace, there are advantages in primary energy efficiency and operating cost. With no electrical connection to the grid, the self-powered furnace also improves resiliency to electric grid outages and reduces demand on the grid, which can be important during periods of peak heating. In addition, when unit size and venting type are maintained, a drop-in replacement with no incremental installation cost and increased potential for market adoption is achieved. In this work, the power generation requirements for such a drop-in-ready, self-powered furnace are analyzed, and available power generation technologies are surveyed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

Reinforced Ammo Can Validation Test Report for Lawrence Livermore National Laboratory

A research effort was conducted to investigate the effects of an unintentional internal detonation of energetic materials on a small transportation container called the “Reinforced Ammo Can” (RAC), which is currently approved for the transport of energetic materials up to 2 grams net explosive weight (NEW) onsite at Lawrence Livermore National Laboratory (LLNL). The project used experimental testing of the containers based on simulated results conducted by a Missouri S & T explosives engineering graduate student while on an internship working in explosives safety at LLNL. The proposed experimental testing consisted of 20 central detonation tests in separate Reinforced Ammo Can containers to verify their high explosive (HE) containment capability. RAC containers are required for transporting secondary explosives on site at LLNL Site 200 in quantities between 300 mg and 2 grams of Trinitrotoluene (TNT) equivalent NEW. Currently, the LLNL Environmental Safety and Health (ES&H) Manual states that the RAC containers are permissible for on-site transportation of secondary explosives up to 2 grams NEW by approved HE handlers with the approval of an Explosives Safety Expert (ESE). Simulated results indicated that tensile failure of the closure mechanism on the container is the most likely failure mode, and showed potential occurrence at the 2 gram NEW threshold. Experimental validation tests were conducted indicating failure/rupture of the containers lid with venting of the detonation products at the 2 gram NEW test threshold with an explosive mass safety factor of 1.3. Failure consisted of impact opening the container latch mechanism resulting in potential ejection of the lid depending on the orientation of the charge within the confinement. This analysis solely is an evaluation of the response of the containment if a detonation were to occur, it does NOT consider the probability of such an event.

42 ENGINEERING↗

Milestone 2.8: Preliminary Radiolytic Gas Generation Measurements from Helium-Backfilled Samples

The Department of Energy (DOE) is currently managing nearly 13 metric tons of aluminum-clad spent nuclear fuel (ASNF) with the intention of extended (> 50 years) dry storage in helium-backfilled canisters. Due to in-reactor and cooling pond conditions, oxyhydroxide corrosion layers have formed on the surface of the ASNF elements. These corrosion layers are susceptible to radiolysis and the formation of molecular hydrogen gas (H 2 ) due to the fuel’s inherent radiation field. Consequently, a rigorous evaluation of the effect of helium gas on radiolytic H 2 production is necessary to support the Technical Considerations and Challenges for Extended (> 50 yrs) Dry Storage of ASNF program, especially as previous Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution work demonstrated a significant effect of gas composition on the radiolytic yield (G-value) of H 2 . Here we report preliminary G-values for the radiolytic formation of H 2 from the gamma irradiation of pre-corroded aluminum alloy 1100 coupons flame sealed in helium environments. Irradiations yielded G(H 2 ) values of (5.1 ± 0.5) x 10 –4 and (9.4 ± 0.9) x 10 –4 µmol J –1 for pristine coupons, and (10.1 ± 0.4) x 10 –4 and (15.1 ± 1.2) x 10 –4 µmol J –1 for pre-corroded coupons for 0% and 50% relative humidity, respectively. These helium environment G(H 2 ) values are between 28% and 58% higher than previously reported values for argon environments. This enhancement is attributed to the significant difference in first ionization energy between helium (24.59 eV) and argon (15.76) facilitating additional processes, e.g., Penning ionization. These new preliminary helium environment G(H 2 ) values will be employed by Task 3 - Sealed and Vented System Episodic Breathing and Gas Generation Prediction to model the effect of radiolytic H 2 accumulation in helium environments to evaluate the practicality of the extended storage standard canister design.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Supplemental Information Regarding the Application for Remediation of the Flanged Tritium Waste Containers at Los Alamos National Laboratory

This letter is in response to the October 18, 2021 letter from David Gray, Acting Regional Administrator, to Mr. Theodore Wyka, Manager of the National Nuclear Security Administration’s Los Alamos Field Office (NA-LA). That letter requested additional information regarding the Application for remediation of the Flanged Tritium Waste Containers (FTWCs) at Los Alamos National Laboratory (LANL) Technical Area 54, Area G. The Emissions Management Plan for the FTWC Venting Project is attached.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of Engine Expansion for Transparent Nozzle Combustion Research

A solenoid valve system and the ability to remotely control devices were added to the transparent nozzle experimental setup. The remote control of the devices allow a user to completely control the experiment via a computer interface. The user can collect data (low speed data acquisition of pressure and temperature and high speed data acquisition of voltage), set injection pressure of the system, and control timing of triggering solenoids, data collection, cameras and injection. The solenoid valve system was shown to work properly and allow for the simulation of engine expansion by cutting off the intake flow of pressure and opening the exhaust flow to a vent. The solenoid valve setup was also shown to help with the problems of splash back and air bubbles forming inside the sack and nozzle tip.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Gaussian Process Emulators for Volcanic Ash Dispersion Model Tephra2

It is necessary to predict volcanic ash deposition since falling ash is harmful to human activities. Because simulators built for this purpose are computationally expensive, it is popular to use statistical emulators for geophysical hazard analyses, where a large number of simulations are required. Gaussian stochastic process emulators are able to approximate expensive simulations in an accurate and efficient way. Using a relatively small number of simulation runs, a well-trained emulator can accurately predict simulation outputs at massive new input points in a few seconds. Under different explosive eruption conditions, we constructed Gaussian stochastic process emulators for Tephra2, a simulation tool for estimating the accumulation of volcanic ash over a region. Historical wind records are used as input wind data, without assuming a Gaussian wind speed profile or common wind direction among elevations. While there are several inputs for Tephra2, we use no more than three physically motivated variables as emulator inputs to reduce the computational cost of emulations. The emulator outputs predict the mass of tephra per unit area at 50281 grid points around a predetermined vent location.

58 GEOSCIENCES↗