Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Preliminary analysis of loss-of-coolant accident in Fukushima nuclear accident

Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal operation, is needed to remove decay heat from the reactor core until the reactor reach cold-shutdown condition. If LOCA happen at this condition, it will cause the increase of reactor fuel and other core temperatures and can lead to reactor core meltdown and exposure of radioactive material to the environment such as in the Fukushima Dai Ichi nuclear accident case. In this study numerical simulation has been performed to calculate pressure composition, water level and temperature distribution on reactor during this accident. There are two coolant regulating system that operational on reactor unit 1 at this accident, Isolation Condensers (IC) system and Safety Relief Valves (SRV) system. Average mass flow of steam to the IC system in this event is 10 kg/s and could keep reactor core from uncovered about 3,2 hours and fully uncovered in 4,7 hours later. There are two coolant regulating system at operational on reactor unit 2, Reactor Core Isolation Condenser (RCIC) System and Safety Relief Valves (SRV). Average mass flow of coolant that correspond this event is 20 kg/s and could keep reactor core from uncovered about 73 hours and fully uncovered in 75 hours later. There are three coolant regulating system at operational on reactor unit 3, Reactor Core Isolation Condenser (RCIC) system, High Pressure Coolant Injection (HPCI) system and Safety Relief Valves (SRV). Average mass flow of water that correspond this event is 15 kg/s and could keep reactor core from uncovered about 37 hours and fully uncovered in 40 hours later.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection of uncompensated magnetization at the interface of an epitaxial antiferromagnetic insulator

We have probed directly the temperature and magnetic field dependence of pinned uncompensated magnetization at the interface of antiferromagnetic FeF 2 with Cu, using FeF 2 -Cu-Co spin valves. Electrons polarized by the Co layer are scattered by the pinned uncompensated moments at the FeF 2 -Cu interface giving rise to giant magnetoresistance. We determined the direction and magnitude of the pinned uncompensated magnetization at different magnetic fields and temperatures using the angular dependencies of resistance. The strong FeF 2 anisotropy pins the uncompensated magnetization along the easy axis independent of the cooling field orientation. Most interestingly, magnetic fields as high as 90 kOe cannot break the pinning at the FeF 2 -Cu interface. This proves that the pinned interfacial magnetization is strongly coupled to the antiferromagnetic order inside the bulk FeF 2 layer. Studies as a function of FeF2 crystalline orientation show that uncompensated spins are only detected in a spin valve with (110) crystal orientation, but not in valves containing FeF 2 (100) and FeF 2 (001). This observation is in agreement with symmetry-related considerations which predict the equilibrium boundary magnetization for the FeF 2 (110) layer.

36 MATERIALS SCIENCE↗

Dynamics of the inlet system of a four-stroke engine

Tests were run on a single-cylinder and a multicylinder four-stroke engine in order to determine the effect of the dynamics of the inlet system upon indicated mean effective pressure. Tests on the single-cylinder engine were made at various speeds, inlet valve timings, and inlet pipe lengths. These tests indicated that the indicated mean effective pressure could be raised considerably at any one speed by the use of a suitably long inlet pipe. Tests at other speeds with this length of pipe showed higher indicated mean effective pressure than with a very short pipe, although not so high as could be obtained with the pipe length adjusted for each speed. A general relation was discovered between optimum time of inlet valve closing and pipe length; namely, that longer pipes require later inlet valve closing in order to be fully effective. Tests were also made on three cylinders connected to a single pipe. With this arrangement, increased volumetric efficiency at low speed was obtainable by using a long pipe, but only with a sacrifice of volumetric efficiency at high speed. Volumetric efficiency at high speed was progressively lower as the pipe length was increased.

ENGINES-CHRYSLER↗

Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy

Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

Non-NASA Center↗

Computer Controlled High Vacuum Gas Purification and Analysis Line

Light stable isotope work requires the handling of gasses such a way that does not alter isotopic composition. To do this, there are a large number of analytical and experimental procedures which involve the use of a vacuum line, numerous “egg timers” and a human hand on a valve. Unfortunately, the human hand is inconsistent and inadvertent small, and commonly large, differences in timing can have a measurable effect on outcomes. We have constructed a computer controlled high-vacuum line to be used as an expandable platform for future experimental and analytical procedures. The vacuum line consists of an electropolished 316 stainless steel system of cryogenic u-traps partitioned by pneumatic valves. The code to operate the line has been developed using the LabView platform and will allow for automated timing, consistent valve opening speed and unattended operation of long analytical procedures. The aim of this project is to address a need in the light stable isotope laboratory for a general-purpose vacuum line for handling and manipulation of gasses. When combined with existing instrumentation it allows for a significant expansion of current analytical capabilities. The system allows for better handling of standards, gas conversion techniques and gas sample collection for interlaboratory comparisons. The basic structure of the line, automation hardware and software were chosen and designed to provide a base for future expansion of the system to incorporate new automated analytical techniques as laboratory instrumentation and analytical needs expand.

High vacuum↗

Supervisory control of a pilot-scale cooling loop

We combine a previously developed strategy for Fault Detection and Identification (FDI) with a supervisory controller in closed loop. The combined method is applied to a model of a pilot-scale cooling loop of a nuclear plant, which includes Kalman filters and a model-based predictive controller as part of normal operation. The system has two valves available for flow control meaning that some redundancy is available. The FDI method is based on likelihood ratios for different fault scenarios which in turn are derived from the application of the Kalman filter. A previously introduced extension of the FDI method is used here to enable detection and identification of non-linear faults like stuck valve problems and proper accounting of the time of fault introduction. The supervisory control system is designed so to take different kinds of actions depending on the status of the fault diagnosis task and on the type of identified fault once diagnosis is complete. Some faults, like sensor bias and drift, are parametric in nature and can be adjusted without need for reconfiguration of the regulatory control system. Other faults, like a stuck valve problem, require reconfiguration of the regulatory control system. The whole strategy is demonstrated for several scenarios.

47 OTHER INSTRUMENTATION↗

Electric actuator modification on a turbine driven feed pump at Calvert Cliffs nuclear power plant - 296

Feedwater systems are a leading contributor to unit SCRAMs as indicated by the 2015 INPO data, where 9 of the 51 SCRAMs recorded were a result of feedwater issues. Digital feedwater control systems and enhanced feed pump control modifications can greatly improve performance and control of the plant feedwater systems and help drive down the potential for reactivity management events and unit SCRAMs. Westinghouse has a strong background in the implementation of digital feedwater control systems, and in planning for a recently completed feedwater control system upgrade at Calvert Cliffs, the Westinghouse team worked with Calvert Cliffs to design a solution to a number of common operational issues. Primarily, improving feedwater control over the entire operating range, eliminating single points of vulnerability (SPV) in the feedwater/feed pump systems and eliminating operational issues with the feed pump steam admission valve hydraulic control oil system. A robust first-of-a-kind design and implementation program was undertaken to split the existing hydraulic valve gear actuator with separate electric actuators. Westinghouse worked with Calvert Cliffs and Emerson Process Management (EPM) to install and commission General Electric (GE) feed pump turbines with separate electric actuators for the high-pressure (HP) and low-pressure (LP) steam admission valves. This successful mechanical and control modification was a first for both the nuclear and non-nuclear power generation industries. Westinghouse is working with a number of other utilities to implement similar modifications for PWR and BWR feed pump applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oxidation, Creep And Fatigue Properties of Bare and Coated 31V alloy

Increasing the efficiency of natural gas reciprocating engines will require materials with better mechanical and corrosion resistance at high temperatures. One solution to increase the lifetime of exhaust valves is to apply an aluminide coating to prevent corrosion assisted fatigue cracking, but the impact of the coating on the valve material mechanical properties needs to be assessed. Creep and high cycle fatigue (HCF) testing were conducted at 816°C on bare and slurry or pack-coated 31V alloy. After annealing according to the 31V standard heat treatment, the coated and bare creep specimens exhibited very similar creep rupture lives. The HCF behavior of the pack-coated alloy was close to the behavior of the bar alloy, but fatigue lifetimes of slurry-coated 31V specimens had higher variability. Aluminide coatings have the potential to improve the valve performance at high temperature, but the coating deposition process needs to be tailored for the substrate standard heat treatment.

31V↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental investigation of a reverse osmosis desalination system directly powered by wave energy

Powering desalination processes with renewable energy is a promising solution to address the global issue of water shortage with minimum carbon footprint and environmental impact. Here, we experimentally investigate a sustainable reverse osmosis (RO) desalination system directly powered by wave energy. In this system, seawater is pressurized and pumped to a RO desalination module via a piston pump directly driven by an oscillating surge wave energy converter (OSWEC). An accumulator is adopted on the feed inlet to mitigate the pressure fluctuations under time-varying ocean conditions. Meanwhile, a needle valve on the brine outlet is used to adjust the system pressure and water recovery. A 1:10 scaled model was designed, fabricated, and tested in a wave tank based on the Froude scaling law. Further, the optimal specific water productivity (SWP) obtained in the tank tests with 3.5 g/L feed salinity was 2.23m 3 /kWh, indicating a full-scale specific water productivity of 0.22m 3 /kWh for 35g/L seawater salinity. The influence of needle valve tuning on the specific water productivity was experimentally investigated and analyzed. Under a specific operational condition, tuning this valve improved specific water productivity by about 17% and reduced the system pressure by 24%, thereby avoiding extreme pressure and improving the system’s capability. This pilot study demonstrates that ocean wave energy is a promising source to sustainably power reverse osmosis desalination and provide freshwater water for coastal regions.

16 TIDAL AND WAVE POWER↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High efficiency, low frequency linear compressor proposed for Gifford-McMahon and pulse tube cryocoolers

In order to reduce the amount of greenhouse gas emissions, which are most likely the cause of substantial global warming, a reduction of overall energy consumption is crucial. Low frequency Gifford-McMahon and pulse tube cryocoolers are usually powered by a scroll compressor together with a rotary valve. It has been theoretically shown that the efficiency losses within the rotary valve can be close to 50%{sup 1}. In order to eliminate these losses we propose to use a low frequency linear compressor, which directly generates the pressure wave without using a rotary valve. First results of this development will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of gas injection location and magnetic perturbations on ICRF antenna performance in ASDEX Upgrade

In ASDEX Upgrade H-modes with H{sub 98}≈0.95, similar effect of the ICRF antenna loading improvement by local gas injection was observed as previously in L-modes. The antenna loading resistance R{sub a} between and during ELMs can increase by more than 25% after a switch-over from a deuterium rate of 7.5⋅10{sup 21} D/s injected from a toroidally remote location to the same amount of deuterium injected close to an antenna. However, in contrast to L-mode, this effect is small in H-mode when the valve downstream w.r.t. parallel plasma flows is used. In L-mode, a non-linearity of R{sub a} at P{sub ICRP}<30 kW is observed when using the gas valve integrated in antenna. Application of magnetic perturbations (MPs) in H-mode discharges leads to an increase of R{sub a}>30% with no effect of spectrum and phase of MPs on R{sub a} found so far. In the case ELMs are fully mitigated, the antenna loading is higher and steadier. In the case ELMs are not fully mitigated, the value of R{sub a} between ELMs is increased. Looking at the W source modification for the improved loading, the local gas injection is accompanied by decreased values of tungsten (W) influx Γ{sub W} from the limiters and its effective sputtering yield Y{sub w}, with the exception of the locations directly at the antenna gas valve. Application of MPs leads to increase of Γ{sub W} and Y{sub w} for some of the MP phases. With nitrogen seeding in the divertor, ICRF is routinely used to avoid impurity accumulation and that despite enhanced Γ{sub W} and Y{sub W} at the antenna limiters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependency of anti-ferro-magnetic coupling strength on Ru spacer thickness of [Co/Pd]{sub n}-synthetic-anti-ferro-magnetic layer in perpendicular magnetic-tunnel-junctions fabricated on 12-inch TiN electrode wafer

We investigated the Ru spacer-thickness effect on the anti-ferro-magnetic coupling strength (J{sub ex}) of a [Co/Pd]{sub n}-synthetic-anti-ferro-magnetic layer fabricated with Co{sub 2}Fe{sub 6}B{sub 2}/MgO based perpendicular-magnetic-tunneling-junction spin-valves on 12-in. TiN electrode wafers. J{sub ex} peaked at a certain Ru spacer-thickness: specifically, a J{sub ex} of 0.78 erg/cm{sup 2} at 0.6 nm, satisfying the J{sub ex} criteria for realizing the mass production of terra-bit-level perpendicular-spin-transfer-torque magnetic-random-access-memory. Otherwise, J{sub ex} rapidly degraded when the Ru spacer-thickness was less than or higher than 0.6 nm. As a result, the allowable Ru thickness variation should be controlled less than 0.12 nm to satisfy the J{sub ex} criteria. However, the Ru spacer-thickness did not influence the tunneling-magneto-resistance (TMR) and resistance-area (RA) of the perpendicular-magnetic-tunneling-junction (p-MTJ) spin-valves since the Ru spacer in the synthetic-anti-ferro-magnetic layer mainly affects the anti-ferro-magnetic coupling efficiency rather than the crystalline linearity of the Co{sub 2}Fe{sub 6}B{sub 2} free layer/MgO tunneling barrier/Co{sub 2}Fe{sub 6}B{sub 2} pinned layer, although Co{sub 2}Fe{sub 6}B{sub 2}/MgO based p-MTJ spin-valves ex-situ annealed at 275 °C achieved a TMR of ∼70% at a RA of ∼20 Ω μm{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large enhancement of bulk spin polarization by suppressing Co{sub Mn} anti-sites in Co{sub 2}Mn(Ge{sub 0.75}Ga{sub 0.25}) Heusler alloy thin film

We have investigated the structure and magneto-transport properties of Co{sub 2}Mn(Ge{sub 0.75}Ga{sub 0.25}) (CMGG) Heusler alloy thin films with near-stoichiometric and Mn-rich compositions in order to understand the effect of Co-Mn anti-sites on bulk spin polarization. Anomalous x-ray diffraction measurements using synchrotron radiated x-rays confirmed that Co{sub Mn} anti-sites easily form in the near-stoichiometric CMGG compound at annealing temperature higher than 400 °C, while it can be suppressed in Mn-rich CMGG films. Accordingly, large enhancement in negative anisotropic magnetoresistance of CMGG films and giant magnetoresistance (GMR) in current-perpendicular-to-plane (CPP) pseudo spin valves were observed in the Mn-rich composition. A large resistance-area product change (ΔRA) of 12.8 mΩ μm{sup 2} was demonstrated in the CPP-GMR pseudo spin valves using the Mn-rich CMGG layers after annealing at 600 °C. It is almost twice of the maximum output observed in the CPP-GMR pseudo spin valves using the near-stoichiometric CMGG. These indicate that the spin polarization of CMGG is enhanced in the Mn-rich composition through suppressing the formation of Co{sub Mn}-antisites in CMGG films, being consistent with first-principle calculation results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗