Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Hypersonic Second-Mode Instability Response to Shaped Roughness

An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 20-Inch Mach 6 Wind Tunnel to examine the influence of arrays of regularly spaced roughness elements on instability growth and transition. The primary element shape was a pair of elliptical planform ramps that were inclined at equal and opposite angles with respect to the local streamwise direction. The element shapes were designed to induce transient growth disturbances that would lead to sustained azimuthal modulation of the boundary layer flow while limiting the nearfield disturbances to avoid an immediate, i.e., effective tripping of the boundary layer. The bulk of the run matrix consisted of testing different element height sat free stream unit Reynolds numbers ranging from 9.8 to 13.1 million per meter. Other element shapes previously designed for tripping hypersonic boundary layers were also implemented. The model was instrumented with surface mounted Kulite ® and PCB ® pressure transducers and thermocouples. Spectra from the PCBs ® indicated clear suppression of the second-mode instability; however, neither the PCB ® spectra nor the heat transfer data presented strong evidence for delayed turbulent flow. Complementary stability computations likewise demonstrated second-mode reduction, particularly just downstream of the roughness, but also revealed a rise in first mode (streak-instability) amplitudes from the baseline that was likely responsible for the earlier transition observed for taller roughness cases.

Hypersonics↗

Hypersonic Second-Mode Instability Response to Shaped Roughness

An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 20-Inch Mach 6 Wind Tunnel to examine the influence of arrays of regularly spaced roughness elements on instability growth and transition. The primary element shape was a pair of elliptical planform ramps that were inclined at equal and opposite angles with respect to the local streamwise direction. The element shapes were designed to induce transient growth disturbances that would lead to sustained azimuthal modulation of the boundary layer flow while limiting the nearfield disturbances to avoid an immediate, i.e., effective tripping of the boundary layer. The bulk of the run matrix consisted of testing different element height sat free stream unit Reynolds numbers ranging from 9.8 to 13.1 million per meter. Other element shapes previously designed for tripping hypersonic boundary layers were also implemented. The model was instrumented with surface mounted Kulite ® and PCB ® pressure transducers and thermocouples. Spectra from the PCBs ® indicated clear suppression of the second-mode instability; however, neither the PCB ® spectra nor the heat transfer data presented strong evidence for delayed turbulent flow. Complementary stability computations likewise demonstrated second-mode reduction, particularly just downstream of the roughness, but also revealed a rise in first mode (streak-instability) amplitudes from the baseline that was likely responsible for the earlier transition observed for taller roughness cases.

Hypersonics↗

Permeation of protons, potassium ions, and small polar molecules through phospholipid bilayers as a function of membrane thickness

Two mechanisms have been proposed to account for solute permeation of lipid bilayers. Partitioning into the hydrophobic phase of the bilayer, followed by diffusion, is accepted by many for the permeation of water and other small neutral solutes, but transient pores have also been proposed to account for both water and ionic solute permeation. These two mechanisms make distinctively different predictions about the permeability coefficient as a function of bilayer thickness. Whereas the solubility-diffusion mechanism predicts only a modest variation related to bilayer thickness, the pore model predicts an exponential relationship. To test these models, we measured the permeability of phospholipid bilayers to protons, potassium ions, water, urea, and glycerol. Bilayers were prepared as liposomes, and thickness was varied systematically by using unsaturated lipids with chain lengths ranging from 14 to 24 carbon atoms. The permeability coefficient of water and neutral polar solutes displayed a modest dependence on bilayer thickness, with an approximately linear fivefold decrease as the carbon number varied from 14 to 24 atoms. In contrast, the permeability to protons and potassium ions decreased sharply by two orders of magnitude between 14 and 18 carbon atoms, and leveled off, when the chain length was further extended to 24 carbon atoms. The results for water and the neutral permeating solutes are best explained by the solubility-diffusion mechanism. The results for protons and potassium ions in shorter-chain lipids are consistent with the transient pore model, but better fit the theoretical line predicted by the solubility-diffusion model at longer chain lengths.

NASA Program Exobiology↗

Final analysis and design of a thermal protection system for 8-foot HTST combustor

The cylindrical shell combustor with T-bar supports in the 8-foot HTST at the NASA-Langley Research Center encountered vibratory fatigue cracking over a period of 50-250 tunnel tests within a limited range of the required operating envelope. A preliminary design study provided several suitable thermal protection system designs for the combustor, one of which was a two-pass regenerative type air-cooled omega-shaped segment liner. A final design layout of the omega segment liner was prepared and analyzed for steady-state and transient conditions. The design of a support system for the fuel spray bar assembly was also included. Detail drawings suitable for fabrication purposes were also prepared. Liner design problems defined during the preliminary study included (1) the ingress of gas into the attachment bulb section of the omega segment, (2) the large thermal gradient along the leg of the omega bulb attachment section and, (3) the local peak metal temperature at the radius between the liner ID and the leg of the bulb attachment. These were resolved during the final design task. Analyses of the final design of the omega segment liner indicated that all design goals were met and the design provided the capability of operating over the required test envelope with a life expectancy substantially above the goal of 1500 cycles.

Moskowitz, S.↗

Physiological mass measurements on Skylab 1/2 and 1/3

Mass measurements of crewmen and objects were made for the first time in space during Skylab. A description of the new devices designed for such measurements and of the technique of their use is detailed. Results from ground-based chamber simulation tests and from those during Skylab II and III show similar patterns of simple metabolic deficits, of a rapid loss during the first few days of flight followed by a reciprocal gain for the first few postflight days, and other transient changes. It is concluded that two major causes of weight loss are present: (1) a fluid redistribution and loss, and (2) metabolic losses. Added to these are short-term changes from transient stress. Smaller, simpler, and cheaper devices have since been designed which should allow mass measurements on virtually any object in almost any spacecraft.

Thornton, W.↗

The design of hydraulic pressure regulators that are stable without the use of sensing line restrictors or frictional dampers

A direct-acting hydraulic pressure regulator design which incorporates stability margin, response and droop margin is developed. The pressure regulator system does not involve a nonlinear sensing line restrictor (which may degrade transient response) or linear damping (which is sensitive to clearance and viscosity). The direct-acting hydraulic pressure regulator makes use of the technique of lead network stabilization (i.e., the tuned stabilizer concept). An analytically derived circuit pressure regulator is tested to study the stability limit under a parallel capacitive plus resistive load and the stabilizing effect of the tuned stabilizer.

Gold, H.↗

A low-power arcjet cyclic lifetest

A cyclic lifetest of a low power dc arcjet thruster using a hydrogen/nitrogen propellant mixture simulating hydrazine is currently in progress. Over 300 hr of operation have been accumulated to date in 2 hr duty cycles at a power level of about 1.15 kW, approximating that available on commercial communications satellites. A burn-in period was carried out before consistent operation was attained. After this period, the arcjet operated in a very stable fashion from cycle to cycle. At the beginning of each cycle, there was a brief starting transient followed by a rapid rise to a steady-state voltage. The steady-state voltage increased by about 5 V over the first 95 cycles. After this, it increased by only 1 V through the remainder of the test. Thrust measurements taken before the life test and again after the completion of the 144th cycle showed that both thrust, specific impulse, and arc voltage had increased over this period of operation. No life limiting mechanisms were observed during the course of the testing.

Curran, Francis M.↗

Accuracy of a class of concurrent algorithms for transient finite element analysis

The accuracy of a new class of concurrent procedures for transient finite element analysis is examined. A phase error analysis is carried out which shows that wave retardation leading to unacceptable loss of accuracy may occur if a Courant condition based on the dimensions of the subdomains is violated. Numerical tests suggest that this Courant condition is conservative for typical structural applications and may lead to a marked increase in accuracy as the number of subdomains is increased. Theoretical speed-up ratios are derived which suggest that the algorithms under consideration can be expected to exhibit a performance superior to that of globally implicit methods when implemented on parallel machines.

Ortiz, Michael↗

Heat flux measurement in SSME turbine blade tester

Surface heat flux values were measured in the turbine blade thermal cycling tester located at NASA-Marshall. This is the first time heat flux has been measured in a space shuttle main engine turbopump environment. Plots of transient and quasi-steady state heat flux data over a range of about 0 to 15 MW/sq m are presented. Data were obtained with a miniature heat flux gage device developed at NASA-Lewis. The results from these tests are being incorporated into turbine design models. Also, these gages are being considered for airfoil surface heat flux measurement on turbine vanes mounted in SSME turbopump test bed engine nozzles at Marshall. Heat flux effects that might be observed on degraded vanes are discussed.

Liebert, Curt H.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Heat flux measurement in SSME turbine blade tester

Surface heat flux values were measured in the turbine blade thermal cycling tester located at NASA-Marshall. This is the first time heat flux has been measured in a space shuttle main engine turbopump environment. Plots of transient and quasi-steady state heat flux data over a range of about 0 to 15 MW/sq m are presented. Data were obtained with a miniature heat flux gage device developed at NASA-Lewis. The results from these tests are being incorporated into turbine design models. Also, these gages are being considered for airfoil surface heat flux measurement on turbine vanes mounted in SSME turbopump test bed engine nozzles at Marshall. Heat flux effects that might be observed on degraded vanes are discussed.

Liebert, Curt H.↗

Load converter interactions with the secondary system in the Space Station Freedom power management and distribution DC test bed

The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF Program design and development phases, a system Power Management and Distribution (PMAD) DC test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

Lebron, Ramon C.↗

Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

Lebron, Ramon C.↗

Method for determining the frequency-response characteristics of an element or system from the system transient output response to a known input function

A method is presented for the determination of the frequency-response characteristics of an element or system by utilizing the transient output response to a known but arbitrary input to the system. Since the application of special inputs, such as step functions or sinusoids, is often imperfect or impractical, a method for utilizing arbitrary inputs is desirable. Simple flight-test data may be reduced by this method to give the frequency response of an aircraft. Examples are given as determinations of aircraft frequency responses; however, the method can be applied to any type of dynamic system, such as automatic-control components, vibration-absorption equipment, and many types of instruments. The method requires that the arbitrary input function tend to a finite value after a finite time and that the system or element output be measured as a representative quantity having a static sensitivity. (author)

Curfman, Howard J↗

High-temperature catalyst for catalytic combustion and decomposition

A robust, high temperature mixed metal oxide catalyst for propellant composition, including high concentration hydrogen peroxide, and catalytic combustion, including methane air mixtures. The uses include target, space, and on-orbit propulsion systems and low-emission terrestrial power and gas generation. The catalyst system requires no special preheat apparatus or special sequencing to meet start-up requirements, enabling a fast overall response time. Start-up transients of less than 1 second have been demonstrated with catalyst bed and propellant temperatures as low as 50 degrees Fahrenheit. The catalyst system has consistently demonstrated high decomposition effeciency, extremely low decomposition roughness, and long operating life on multiple test particles.

Mays, Jeffrey A.↗

Hovering and Low-Speed Performance and Control Characteristics of the Kaman Helicopter Rotor System as Determined on the Langley Helicopter Tower. TED No. NACA DE 205

An investigation has been conducted with the Langley helicopter tower to obtain basic performance and control characteristics of the Raman rotor system. Blade-pitch control is obtained in this configuration by utilizing an auxiliary flap to twist the blades. Rotor thrust and power required were measured for the hovering condition and over a range of wind velocities from 0 to 30 miles per hour. The control characteristics and the transient response of the rotor to various control movements were also measured. The hovering-performance data are presented as a survey of the wake velocities and the variation of torque coefficient with thrust coefficient. The power required for the test rotor to hover at a thrust of 1350 pounds and a rotor speed of 240 rpm is approximately 6.5 percent greater than that estimated for a conventional rotor of the same diameter and solidity. It is believed that most of this difference is caused by th e flap servomechanism. The reduction in total power required for sustentation of the single-rotor configuration tested at various wind velocities and at the normal operating rotor thrust was found to be similar to the theoretical and experimental results for ro tors with conventionally actuated pitch. The control effectiveness was determined as a function of rotor speed. Sufficient control was available to give a thrust range of 0 to 1500 pounds and a rotor tilt of plus or minus 7 degrees. The time lag between flap motion and blade-pitch response is approximately 0.02 to 0.03 second. The response of the rotor following the blade-pitch response is similar to that of a rotor with conventionally actuated pitch changes. The over-all characteristics of the rotor investigated indicate that satisfactory performance and control characteristics were obtained.

Carpenter, Paul J.↗

Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

Ku, Jentung↗

Mechanical Testing of PMCs under Simulated Rapid Heat-Up Propulsion Environments: In-Plane Compressive Behavior - II

Carbon fiber thermoset polymer matrix composites (PMC) with high temperature polyimide based in-situ polymerized monomer reactant (PMR) resin has been used for some time in applications which can see temperatures up to 550 F. Currently, graphite fiber PMR based composites are used in several aircraft engine components including the outer bypass duct for the GE F-404, exit flaps for the P&W F-100-229, and the core cowl for the GE/Snecma CF6-80A3. Newer formulations, including PMR-II-50 are being investigated as potential weight reduction replacements of various metallic components in next generation high performance propulsion rocket engines that can see temperatures which exceed 550 F. Extensive FEM thermal modeling indicates that these components are exposed to rapid heat-up rates (up to -200 F/sec) and to a maximum temperature of around 600 F. Even though the predicted maximum part temperatures were within the capability of PW-II-50, the rapid heat-up causes significant through-thickness thermal gradients in the composite part and even more unstable states when combined with moisture. Designing composite parts for such extreme service environments will require accurate measurement of intrinsic and transient mechanical properties and the hygrothermal performance of these materials under more realistic use conditions. The mechanical properties of polymers degrade when exposed to elevated temperatures even in the absence of gaseous oxygen. Accurate mechanical characterization of the material is necessary in order to reduce system weight while providing sufficient factors of safety. Historically, the testing of PMCs at elevated temperatures has been plagued by the antagonism between two factors. First, moisture has been shown to profoundly affect the mechanical response of these materials at temperatures above their glass transition temperature while concurrently lowering the material's Tg. Moisture phenomena is due to one or a combination of three effects, i.e., plastization of polymeric material by water, the internal pressure generated by the volatilization of water at elevated temperatures, and hydrolytic chemical decomposition. However, moisture is lost from the material at increasing rates as temperature increases. Second, because PMCs are good thermal insulators, when they are externally heated at even mild rates large thermal gradients can develop within the material. At temperatures where a material property changes rapidly with temperature the presence of a large thermal gradient is unacceptable for intrinsic property characterization purposes. Therefore, long hold times are required to establish isothermal conditions. However, in the service environments high-heating-rates, high temperatures, high-loading rates are simultaneous present along with residual moisture. In order to capture the effects of moisture on the material, holding at- temperature until isothermal conditions are reached is unacceptable particularly in materials with small physical dimensions. Thus, the effects due to moisture on the composite's mechanical characteristics, ie., their so-called analog response, may be instructive. One approach employed in this program was rapid heat-up (approx. 200 F/sec.) and loading of both dry and wet in-plane compressive specimens to examine the effects of moisture on this resin dominated mechanical property of the material.

Stokes, Eric H.↗