Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Using SpaceClaimTD Direct for Modeling Components with Complex Geometries for the Thermal Desktop-Based Advanced Stirling Radioisotope Generator Model

SpaceClaim/TD Direct has been used extensively in the development of the Advanced Stirling Radioisotope Generator (ASRG) thermal model. This paper outlines the workflow for that aspect of the task and includes proposed best practices and lessons learned. The ASRG thermal model was developed to predict component temperatures and power output and to provide insight into the prime contractor's thermal modeling efforts. The insulation blocks, heat collectors, and cold side adapter flanges (CSAFs) were modeled with this approach. The model was constructed using mostly TD finite difference (FD) surfaces/solids. However, some complex geometry could not be reproduced with TD primitives while maintaining the desired degree of geometric fidelity. Using SpaceClaim permitted the import of original CAD files and enabled the defeaturing/repair of those geometries. TD Direct (a SpaceClaim add-on from CRTech) adds features that allowed the "mark-up" of that geometry. These so-called "mark-ups" control how finite element (FE) meshes are to be generated through the "tagging" of features (e.g. edges, solids, surfaces). These tags represent parameters that include: submodels, material properties, material orienters, optical properties, and radiation analysis groups. TD aliases were used for most tags to allow analysis to be performed with a variety of parameter values. "Domain-tags" were also attached to individual and groups of surfaces and solids to allow them to be used later within TD to populate objects like, for example, heaters and contactors. These tools allow the user to make changes to the geometry in SpaceClaim and then easily synchronize the mesh in TD without having to redefine the objects each time as one would if using TDMesher. The use of SpaceClaim/TD Direct helps simplify the process for importing existing geometries and in the creation of high fidelity FE meshes to represent complex parts. It also saves time and effort in the subsequent analysis.

Power Systems↗

Large-area sheet task advanced dendritic web growth development

Thermal models were developed that accurately predict the thermally generated stresses in the web crystal which, if too high, cause the crystal to degenerate. The application of the modeling results to the design of low-stress experimental growth configurations will allow the growth of wider web crystals at higher growth velocities. A new experimental web growth machine was constructed. This facility includes all the features necessary for carrying out growth experiments under steady thermal conditions. Programmed growth initiation was developed to give reproducible crystal starts. Width control permits the growth of long ribbons at constant width. Melt level is controlled to 0.1 mm or better. Thus, the capability exists to grow long web crystals of constant width and thickness with little operator intervention, and web growth experiments can now be performed with growth variables controlled to a degree not previously possible.

Duncan, C. S.↗

Space Station Active Thermal Control System modeling

The Space Station Active Thermal Control System (ATCS) has been modeled using modified SINDA/SINFLO programs to solve two-phase Thermo-fluid problems. The modifications include changes in several subroutines to incorporate implicit solution which allows larger time step as compared to that for explicit solutions. Larger time step saves computer time but involves larger computational error. Several runs were made using various time steps for the ATCS model. It has been found that for a reasonable approach, three times larger time step as compared to that used in explicit method is a good value which will reduce the computer time by approximately 50 percent and still maintain the accuracy of the output data to within 90 percent of the explicit values.

Hye, Abdul↗

SR-1 Freedom Thermal Architecture Challenges

The SR-1 Freedom mission aims to demonstrate nuclear electric propulsion (NEP) and deliver the Skyfall helicopter payload to Mars. Repurposing the existing Gateway Power and Propulsion Element (PPE) spacecraft and combining it with a 20 kWe-class nuclear power module (NPM) presents a variety of thermal architecture challenges. These include unprecedented waste heat rejection requirements, integration with a spacecraft bus originally designed for a different mission profile, and novel packaging constraints. This presentation will describe the simplified concept of operations as it relates to on-orbit thermal environments, early-phase architecture trades and supporting analyses, and planned forward work. We will also discuss our strategy for integrated thermal modeling of the complete spacecraft and examples of interface challenges necessitated by this ambitious effort.

Thermal↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

VAB Temperature and Humidity Study

In 2012, 17 data loggers were placed in the VAB to measure temperature and humidity at 10-minute intervals over a one-year period. In 2013, the data loggers were replaced with an upgraded model and slight adjustments to their locations were made to reduce direct solar heating effects. The data acquired by the data loggers was compared to temperature data provided by three wind towers located around the building. It was found that the VAB acts as a large thermal filter, delaying and reducing the thermal oscillations occurring outside of the building. This filtering is typically more pronounced at higher locations in the building, probably because these locations have less thermal connection with the outside. We surmise that the lower elevations respond more to outside temperature variations because of air flow through the doors. Temperatures inside the VAB rarely exceed outdoor temperatures, only doing so when measurements are made directly on a surface with connection to the outside (such as a door or wall) or when solar radiation falls directly on the sensor. A thermal model is presented to yield approximate filter response times for various locations in the building. Appendix A contains historical thermal and humidity data from 1994 to 2009.

Temperature↗

Thermal and Deposition Modeling of the Canister Deposition Field Demonstration

This report provides initial thermal and deposition modeling results of the spent nuclear fuel (SNF) storage system planned for use in the Canister Deposition Field Demonstration (CDFD). The goal of the CDFD testing is to collect deposition measurements on the surface of the dry shielded canister (DSC) to aid in chloride-induced stress corrosion crack (CISCC) research. Ideally this testing will occur in a marine coastal environment but at the time of this report no official site has been selected. The CDFD will use the NUHOMS ® Advanced Horizontal Storage Module – High Seismic (AHSM-HS) with a 32PTH2 canister. The SNF assemblies will be replaced with electrical heaters. Canisters are currently being outfitted with these heaters and tested at Sandia National Laboratory (SNL). Thermal modeling was conducted to ensure the electrical heaters were representative of the temperature distribution found within a storage system with SNF. Deposition models were built to evaluate contaminant deposition on SNF canisters. The CDFD testing will help to validate these models, which will then be used to plan and inform on-site test programs and predictive models for the timing and occurrence of canister CISCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of Rei-mullite Physical Properties

Micromechanical and thermal modeling studies prove that ceramic fiber mullite materials is the only system capable of shuttle thermal protection to 1644 K. Hafnia pigmentated mullite surface coatings meet both orbital and reentry thermal radiative requirements for reuse without refurbishment. Thermal and mechanical models show growths potentials associated with the mullite system for a factor of 2 improvement in mechanical properties, and a factor of 2 to 3 reduction in thermal conductivity.

Tanzilli, R. A.↗

Power Electronics Thermal Management

Thermal modeling was conducted to evaluate and develop thermal management strategies for high-temperature wide-bandgap (WBG)-based power electronics systems. WBG device temperatures of 175 degrees C to 250 degrees C were modeled under various under-hood temperature environments. Modeling result were used to identify the most effective capacitor cooling strategies under high device temperature conditions.

30 DIRECT ENERGY CONVERSION↗

GALAXY CLUSTERS IN THE SWIFT/BAT ERA. II. 10 MORE CLUSTERS DETECTED ABOVE 15 keV

We report on the discovery of 10 additional galaxy clusters detected in the ongoing Swift/Burst Alert Telescope (BAT) all-sky survey. Among the newly BAT-discovered clusters there are Bullet, A85, Norma, and PKS 0745-19. Norma is the only cluster, among those presented here, which is resolved by BAT. For all the clusters, we perform a detailed spectral analysis using XMM-Newton and Swift/BAT data to investigate the presence of a hard (non-thermal) X-ray excess. We find that in most cases the clusters' emission in the 0.3-200 keV band can be explained by a multi-temperature thermal model confirming our previous results. For two clusters (Bullet and A3667), we find evidence for the presence of a hard X-ray excess. In the case of the Bullet cluster, our analysis confirms the presence of a non-thermal, power-law-like, component with a 20-100 keV flux of 3.4 x 10{sup -12} erg cm{sup -2} s{sup -1} as detected in previous studies. For A3667, the excess emission can be successfully modeled as a hot component (kT {approx} 13 keV). We thus conclude that the hard X-ray emission from galaxy clusters (except the Bullet) has most likely a thermal origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity analysis of thermal contact conductance modeling to inform MiniFuel irradiation capsule designs

The MiniFuel irradiation platform has been developed by Oak Ridge National Laboratory as a flexible, high-throughput separate effects testing capability within the High Flux Isotope Reactor (HFIR). Finite element thermal models are relied upon to design MiniFuel experiments to achieve a specific time-averaged irradiation temperature for experimental objectives. A previous study identified that uncertainty in the component heat generation rates and thermal contact conductance (TCC) model are the most significant contributors to predicted fuel temperature variance. To address both sources of uncertainty, this work performs sensitivity analysis on the TCC model to identify high-impact, high-uncertainty parameters that contribute to fuel temperature variance. The TCC model is analyzed in increasing detail, first using a standalone Python code, then again after coupling Python to the BISON fuel performance code. Furthermore, the parameters with the largest contributions to fuel temperature variance which can be reduced through design changes are identified as the initial subcapsule gas pressure, contact pressure between the fuel and dish, and the effective surface roughness of the interface. A set of design recommendations for future capsule designs has been established and applied to reduce the previously quantified average fuel temperature uncertainty ranges of ± 40 °C in the HFIR vertical experiment facilities (VXF) and ± 80 °C in the removable beryllium (RB) reflector to approximately ± 32 °C and ± 53 °C, respectively. This equates to a 21 % and 33 % reduction in the uncertainty range of the average fuel temperature for VXF and RB, respectively.

BISON↗

Large-area sheet task: Advanced dendritic-web-growth development

Thermally generated stresses in the growing web crystal were reduced. These stresses, which if too high cause the ribbon to degenerate, were reduced by a factor of three, resulting in the demonstrated growth of high-quality web crystals to widths of 5.4 cm. This progress was brought about chiefly by the application of thermal models to the development of low-stress growth configurations. A new temperature model was developed which can analyze the thermal effects of much more complex lid and top shield configurations than was possible with the old lumped shield model. Growth experiments which supplied input data such as actual shield temperature and melt levels were used to verify the modeling results. Desirable modifications in the melt level-sensing circuitry were made in the new experimental web growth furnace, and this furnace has been used to carry out growth experiments under steady-state conditions. New growth configurations were tested in long growth runs at Westinghouse AESD which produced wider, lower stress and higher quality web crystals than designs previously used.

Duncan, C. S.↗

Toward efficient elastocaloric systems: Predicting material thermal properties with high fidelity

A critical need to accurately model thermal behaviors of materials that exhibit strong elastocaloric effects, including predicting the effects themselves at varying stresses and temperatures, has been addressed using a simple and versatile physics-based approach. The key factor leading to the high precision is approximating the underlying elastic phase transition as a smooth modification of lattice entropy between coexisting phases. Once the phase transformation entropy is modeled to match experimentally measured strain as a function of temperature and applied stress, estimating the heat capacity, entropy, and isothermal entropy and adiabatic temperature changes in temperature-stress coordinates becomes straightforward. This approach provides insight into how thermal properties of elastocaloric materials vary through the transition based on strain measurements that are simple to perform and interpret. In addition to aiding in the rapid evaluation of new and existing elastocaloric materials, this advance is expected to prove invaluable for accurate heat transfer modeling aimed at designing efficient regenerative elastocaloric cooling devices.

36 MATERIALS SCIENCE↗

Rates of fluvio-thermal erosion on Mars

In order to get some ideas about the order of magnitude of fluvio-thermal recession rate, a mathematical thermal model for Martian outflow channels is proposed. This model corresponds to a system undergoing a permanent thermal regime where the surface temperature is constant and equal to the phase change temperature (due to the immediate removal of melted materials). This is an ablation model. For its application, estimations of the heat transfer coefficient h and thermal flux q are necessary. Determination of these coefficients needs the calculation of dimensionless numbers (Reynolds, Prandtl, and Nusselt), and the consideration of turbulent regime of the flow.

Aguirre-Puente, J.↗

Analytical Study of the relationship Between an Absorber Cavity and Solar Fresnel Concentrator

This paper presents an analytical study of the relationship between an engine absorber cavity and a solar concentrator in a solar thermal propulsion system. The engine is a thermal storage engine, and the concentrator consists of a primary thin-film fresnel concentrator and a secondary Compound Parabolic Concentrator. Two thermal models of the engine are developed, a blackbody cavity model and a 2D numerical model. Results of the two models are compared, with attention to the limitations of the blackbody model 'Me fresnel concentrator model is based on a Circle of Least Confusion approach. The results of the thermal and optical models are combined to create a combined model with absorber temperature predictions. This combined model approach is used to predict an optimum engine aperture size.

Pearson, J. Boise↗

Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Thermal↗

Fallon FORGE: Distinct Element Reservoir Modeling

Archive containing input/output data for distinct element reservoir modeling for Fallon FORGE. Models created using 3DEC, InSite, and in-house Python algorithms (ITASCA). List of archived files follows; please see 'Modeling Metadata.pdf' (included as a resource below) for additional file descriptions. Data sources include regional geochemical model, well positions and geometry, principal stress field, capability for hydraulic fractures, capability for hydro-shearing, reservoir geomechanical model-stimulation into multiple zones, modeled thermal behavior during circulation, and microseismicity.

15 GEOTHERMAL ENERGY↗