High Temperature Thermoelectric Properties of SrTiO3 Under Controlled pO2.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Multiply charged anions (MCA’s) are common in the condensed phases, but are challenging to study in the gas phase. An experimental technique coupling photoelectron spectroscopy (PES) with electrospray ionization (ESI) has been developed to investigate properties of free MCA’s in the gas phase. In this article, the principles of this technique, and some initial findings about the intrinsic properties of MCA’s are reviewed. Examples chosen include the observation of the repulsive Coulomb barrier that exists universally in MCA’s and its effects on the dynamic stability and photoelectron spectroscopy of MCA’s. Solvation and solvent stabilization of MCA’s has been studied in the gas phase and will also be discussed. A second generation low-temperature ESI-PES apparatus has been developed, which allows ion temperatures to be controlled between 10 to 350 K. New results from the low-temperature ESI-PES instrument will also be reviewed, including doubly charged fullerene anions, inorganic metal complexes, and temperature-induced conformation changes of complex anions.
This feasibility study was motivated by a need for alternative mandrel materials to meet the next generation of inertial confinement fusion (ICF) ablator capsules. In response, a new polymer material based on reversible covalent bonds was proposed, with the objective to design thermosets to withstand elevated temperatures (140-200 degrees Celsius) while also being thermally degradable on-demand via controlled decomposition at temperatures above 200 degrees Celsius. A series of cyclopentadiene (Cp) containing thermosets were designed and synthesized to evaluate curing, reversibility and degradability controlled via retro-Diels Alder reactions using Cp-cycloaddition adducts as crosslinks. Ultimately, the current iteration of materials and strategy pursued in this study was assessed as impractical for meeting the needs and objectives of Lawrence Livermore National Laboratory’s (LLNL) target fabrication program.
This feasibility study was motivated by a need for alternative mandrel materials to meet the next generation of inertial confinement fusion (ICF) ablator capsules. In response, a new polymer material based on reversible covalent bonds was proposed, with the objective to design thermosets to withstand elevated temperatures (140-200 degrees Celsius) while also being thermally degradable on-demand via controlled decomposition at temperatures above 200 degrees Celsius. A series of cyclopentadiene (Cp) containing thermosets were designed and synthesized to evaluate curing, reversibility and degradability via controlled retro-Diels Alder reactions using Cp-cycloaddition adducts as crosslinks. Ultimately, the current iteration of materials and strategy pursued in this study was assessed as impractical for meeting the needs and objectives of Lawrence Livermore National Laboratory’s (LLNL) target fabrication program.
When combined with nanostructured substrates, two-dimensional semiconductors can be engineered with strain to tailor light–matter interactions on the nanoscale. Recently, room-temperature nanoscale exciton localization with controllable wrinkling in 1L-WSe2 was achieved using arrays of gold nanocones. Here, the characterization of quantum dot-like states and single-photon emitters in the 1L-WSe2/nanocone system is reported. The nanocones induce a wide range of strains, and as a result, a diverse ensemble of narrowband, potential single-photon emitters is observed. The distribution of emitter energies reveals that most reside in two spectrally isolated bands, leaving a less populated intermediate band that is spectrally isolated from the ensembles. The spectral isolation is advantageous for high-purity quantum light emitters, and anti-bunched emission from one of these states is confirmed up to 25 K. Although the spatial distribution of strain is expected to influence the orientation of the transition dipoles of the emitters, multimodal emission polarization anisotropy and atomic force microscopy reveal that the macroscopic orientation of the wrinkles is not a good predictor of dipole orientation. Finally, the emission is found to change with thermal cycling from 4 to 290 K and back to 4 K, highlighting the need to control factors such as temperature-induced strain to enhance the robustness of this quantum emitter platform. The initial characterization here shows that controlled nanowrinkles of 1L-WSe2 generate quantum light in addition to uncovering potential challenges that need to be addressed for their adoption into quantum photonic technologies.
Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.
The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency, which faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68°F) than day (73° F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.
A challenge in the synthesis of single–wall carbon nanotubes (SWCNTs) is the lack of control over the formation and evolution of catalyst nanoparticles and the lack of control over their size or chirality. Here, zeolite MFI nanosheets (MFI–Ns) are used to keep cobalt (Co) nanoparticles stable during prolonged annealing conditions. Environmental transmission electron microscopy (ETEM) shows that the MFI–Ns can influence the size and shape of nanoparticles via particle/support registry, which leads to the preferential docking of nanoparticles to four or fewer pores and to the regulation of the SWCNT synthesis products. The resulting SWCNT population exhibits a narrow diameter distribution and SWCNTs of nearly all chiral angles, including sub–nm zigzag (ZZ) and near–ZZ tubes. Theoretical simulations reveal that the growth of these unfavorable tubes from unsupported catalysts leads to the rapid encapsulation of catalyst nanoparticles bearing them; their presence in the growth products suggests that the MFI–Ns prevent nanoparticle encapsulation and prologue ZZ and near–ZZ SWCNT growth. Furthermore, these results thus present a path forward for controlling nanoparticle formation and evolution, for achieving size– and shape–selectivity at high temperature, and for controlling SWCNT synthesis.
High flame temperature oxy-combustion and low flame temperature oxy-combustion are the two primary types of oxy-combustion, which is the combustion of fossil fuel with oxygen instead of air. High flame temperature oxy-combustion results in increased radiant energy, but heat flux at the water walls has been demonstrated to be maintained within design parameters. Less fossil fuel is used, so less CO{sub 2} is produced. Latent and sensible heat can be partially recovered from the compressors. CO{sub 2} capture costs are decreased. Evenly distributed heat avoids creating hot spots. The NETL IPR capture system can capture 100% of the CO{sub 2} when operating at steady state. New boiler designs for high flame temperature oxy-combustion can take advantage of the higher flame temperatures. High flame temperature oxy-combustion with IPR capture can be retrofitted on existing plants. High flame temperature oxy-combustion has significantly improved radiant heat transfer compared to low flame temperature oxy-combustion, but heat flux at the water walls can be controlled. High flame temperature oxy-combustion used with the NETL's Integrated Pollutant Removal System can capture 95%-100% of the CO{sub 2} with heat recovery. These technologies create CO{sub 2} capture cost savings, and are applicable to new design and existing design boilers.
The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.
The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.
The Sr deficient perovskite Sr{sub 0.92}NbO{sub 3} was synthesized from Sr{sub 5}Nb{sub 4}O{sub 15} and Nb and its crystal structure was determined using powder neutron diffraction. At room temperature the structure is orthorhombic in space group Pnma with both in-phase and out-of-phase tilting of the NbO{sub 6} octahedra. High temperature measurements have shown that the oxide undergoes a sequence of phase transitions with increasing temperature: Pnma{yields}P4/mbm{yields}Pm3-bar m. The intermediate tetragonal phase has only in-phase tilts of the NbO{sub 6} octahedra, rather than the out-of-phase tilts present in the more commonly observed I4/mcm structure, due to initial softening at the M point rather than R point. The tetragonal phase exists only over a very narrow temperature range. The importance of M-M and M-O bonding in controlling the transition temperatures in SrMO{sub 3} perovskites is discussed. - Graphical abstract: Variable temperature powder neutron diffraction measurements reveal that Sr{sub 0.92}NbO3 undergoes a sequence of phase transitions Pnma{yields}P4/mbm{yields}Pm3m with unanticipated softening of the M point rather than R point resulting in the formation of the primitive tetragonal intermediate.
Atomic-level identification of carbon intermediates under reaction conditions is essential for carbon-related heterogeneous catalysis. Using the in operando technique of near-ambient-pressure X-ray photoelectron spectroscopy, we have identified in this paper various carbon intermediates during the thermal decomposition of CH 4 on Ni(111), including *CH, *C 1 /Ni 3 C, *C n (n ≥ 2), and clock-reconstructed Ni 2 C at different temperature regions (300–900 K). These “reactive” carbon precursors can either react with probing molecules such as O 2 at room temperature or be etched away by CH 4 . They can also develop into graphene flakes under controlled conditions: a temperature between 800 and 900 K and a suitable CH 4 pressure (10 –3 –10 –1 mbar, depending on temperature). The growth rate of graphene is significantly restrained at higher CH 4 pressures, due to the accelerated etching of its carbon precursors. The identification of in operando carbon intermediates and the control of their evolution have great potential in designing heterogeneous catalysts for the direct conversion of methane. Finally, the observed carbon aggregation/etching equilibrium reveals an underlying mechanism in coking prevention and in the fabrication of large-area single-crystal graphene, where the suppression of seeding density and etching up of small grains are required.
We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.
The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.
A series of perovskite materials (BaMnO{sub 3−δ} and Ba{sub 1−x}Sr{sub x}MnO{sub 3}) were synthesized by a solid-state reaction method. The content of oxygen vacancy can be controlled by verifying the sintering temperature and atmosphere. Two obvious divarications between zero-field-cooling curves and field-cooling curves were observed in a high-temperature region of 250–300 K and at a low temperature of 40 K, respectively. It is found that the different oxygen vacancy contents in BaMnO{sub 3−δ} cause the change of crystalline structure and variation of the divarication temperature at a high-temperature region. The factor that controls the negative magnetic susceptibility was discussed. The superexchange interaction between Mn ions can give rise to the coexistence of the ferromagnetic phase and antiferromagnetic phase in the system. We further performed the study of magnetocaloric effect in Sr-doped BaMnO{sub 3}. However, the values of magnetic entropy change and refrigeration coefficient are much smaller than those of rare-earth manganites due to the weak magnetocrystalline anisotropy in Ba{sub 1−x}Sr{sub x}MnO{sub 3}.