Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Welding space vacuum technology

The objective was to assist the EH 42 Division in putting together a vacuum system that could attain the desired pressure and be large enough to accommodate the gas-metal arc (GMA) welding fixture apparatus. A major accomplishment was the design and fabrication of the controller/annunciator for the 4' by 8' system. It contains many safety features such as thermocouple set point relays that will only allow inlet and exit gas and vacuum valves to be operated at pre-selected system pressures, and a fail safe mode for power interruptions and operator mistakes. It is felt that significant progress was made in this research effort to weld in a vacuum environment. With continued efforts to increase the pump speeds for vacuum chambers and further studies on weld fixtures and gas inlet pressures, the NASA program will be successful.

Johnson, R. Barry↗

Effect of lubricant jet location on spiral bevel gear operating temperatures

An experimental study was conducted to determine the effect of lubricant jet location on spiral bevel gear bulk temperatures. Transient surface temperatures were also measured. Tests were conducted on aircraft quality spiral bevel gears in a closed loop test facility. Thermocoupled pinions and an infrared microscope were used to collect the pertinent data. A single fan jet lubricated the test gears. Lubricant flow rate (lubricant jet pressure) and applied torque were also varied. The results showed that jet placement had a significant effect on the gear bulk temperatures.

Handschuh, Robert F.↗

Mg-perovskite/silicate melt partition coefficients in the CMS system at 2430 C and 226 Kbars

The partitioning of elements among lower mantle phases and silicate melts is of interest in unraveling the early thermal history of the Earth. Because of the technical difficulty in carrying out such measurements, only one direct set of measurements has been reported, and these results as well as interpretations based on them have generated controversy. The first set of direct measurements on a synthetic system in the CaO-MgO-SiO2 (CMS) is reported. An experiment was conducted at Stony Brook, using the USSA-2000 split sphere anvil apparatus. An experiment in the CMS system doped with oxides of Al, Ti, Sc, and Sm and run at a nominal temperature of 2380 C and pressure of 226 kbars is reported. Nominal temperatures were measured with a W 3 percent Re/W 25 percent Re thermocouple. The hot spot temperature, where the liquidus is located, is estimated to be at 2430 C. A 10 mm MgO octahedron was used in concert with 4 mm truncation edge lengths on the WC cubes. The sample was contained in a Re capsule which was inserted into a LaCrO3 furnace. Pressure was calibrated at 2000 C. Run duration was approximately 3 minutes. The charge was mounted in epoxy and analyzed using a CAMECA SX-50 electron microprobe. Standard operating conditions were employed, although counting time for the less abundant elements was increased to improved counting statistics. The melt is unquenchable, and forms a dendritic intergrowth of quench crystals and residual melt. It was analyzed using a 30 micron raster. The structural identity of the Mg-perovskite phase was confirmed using x ray microdiffractometry. The results of the investigation are presented.

Mcfarlane, Elisabeth A.↗

Dynamic response of induced pressures, suckdown, and temperatures for two tandem jet STOVL configurations

NASA Ames Research Center has been conducting a program to improve the methods for predicting the jet-induced lift loss (suckdown) and hot gas ingestion on jet Short Takeoff and Vertical Landing (STOVL) aircraft during hover near the ground. As part of that program, small-scale hover tests were conducted to expand the current data base and to improve upon the current empirical methods for predicting jet-induced lift loss and hot gas ingestion (HGI) effects. This report is one of three data reports covering data obtained from hover tests conducted at Lockheed Aeronautical Systems, Rye Canyon Facility. It will include dynamic (time dependent) test data for both lift loss and HGI parameters (height, nozzle temperature, nozzle pressure ratio, and inlet location). The flat plate models tested were tandem jet configurations with three planform variations and variable position side-by-side sucking inlets mounted above the planform. Temperature time lags from 8-15 seconds were observed before the model temperatures stabilize. This was larger than the expected 1.5-second lag calculated from literature. Several possible explanations for the flow temperatures to stabilize may include some, or all, of the following: thermocouple lag, radiation to the model surface, and heat loss to the ground board. Further investigations are required to understand the reasons for this temperature lag.

Wardwell, Douglas A.↗

Relationship between wind, waves and radar backscatter

The aim of the research was to investigate the relationship between wind, waves, and radar backscatter from water surface. To this end, three field experiments with periods of 2 to 4 weeks were carried out during summer months in 1988, 1989 and 1990. For these periods, the University of Washington group provided (1) environmental parameters such as wind speed, wind stress, and atmospheric stratification through measurements of surface fluxes (of momentum, sensible heat and latent heat) and of air and water temperatures; and (2) wave height spectra including both the dominant waves and the short gravity-capillary waves. Surface flux measurements were performed by using our well tested instruments: a K-Gill twin propeller-vane anemometer and a fast response thermocouple psychrometer. Wave heights were measured by a resistance wire wave gauge. The University of Kansas group was responsible for the operation of the microwave radars.

Katsaros, Kristina B.↗

Summary of aerothermal test results from the first flight of the Pegasus air-launched space booster

Temperature measurements were obtained on the Pegasus booster from launch through Mach 8.0. The majority of sensors were thin-foil temperature gages installed near the surface within the vehicle's ablating thermal protection system. These gages were distributed on the wing surfaces and on the wing-body fairing or fillet. Temperature time histories from these installations are presented. In addition, thermocouples were installed on the surface of nonablating plugs located on the fairing. These sensors were more responsive to changes in flight conditions than the foil gages and allowed a derivation of convective heat flux. A heating rate magnification of 2 was found in the vicinity of the wing shock interaction.

Noffz, Gregory K.↗

Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment - STS-35 and STS-40 preliminary results

Preliminary results from the STS-35 and STS-40 flight of the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment aboard the Shuttle Orbiter Columbia are presented. Infrared images are shown in false-color indicating the level and distribution of surface temperature over the vehicle's leeside fuselage during entry. Features evident in the imagery are related to their causative aerodynamic flow phenomena. Quantitative comparisons of the infrared image data with in situ temperature measurements obtained with thermocouples located at the aerodynamic surface of the thermal protection materials are presented.

Throckmorton, David A.↗

Operation and design considerations for unsteady data acquisition with PC-based systems in high Reynolds number hypersonic flowfields

Operation and design considerations for personal-computer-based data acquisition are analyzed, and a system is created that is portable, inexpensive, and capable of high-frequency response. This system performed well when given an extensive analysis of the characteristics of the radio-frequency noise in the test environment. The system architecture is well-suited for support of high-frequency data acquisition from both pressure transducers and high-frequency-response thermocouple gauges. As configured, the system provides a data resolution of approximately 0.09 psia and 0.56 F. Considering the constraints placed upon this design, this data resolution is acceptable. The $5000 budget did require use of an existing PC and rental of signal-conditioning equipment.

Flanagan, M. J., Jr.↗

Quantitative fluorescence measurements of the OH radical in high pressure methane flames

A method for quantifying laser-induced fluorescence signals from the OH radical in high-pressure flames is presented. The fluorescence signal per unit OH mole fraction is modeled as a function of temperature, pressure, and overall flame stoichiometry. Known values of the collisional quenching cross sections as a function of temperature are used to model the electronic quench rate. The reverse A - X (1.0) Q15 transition is used with broadband collection to measure single-point fluorescence produced by a pulsed Nd:YAG-pumped, frequency-doubled dye laser. Laser absorption and thermocouples are used to measure absolute OH concentration and temperature, respectively, which are used to confirm the validity of the model. Measurements are made in CH4/O2/N2 flames up to 10 atm.

Battles, B. E.↗

Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K

The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.

Lagen, Nicholas T.↗

Heat-Transfer Measurements Obtained on the X-15 Airplane Including Correlations With Wind-Tunnel Results

Heat-transfer measurements were obtained on the X-15 airplane from two flights under quasi-steady conditions at a free-stream Mach number of 5.1 and an angle of attack of 2.0° and a free-stream Mach number of 4.98 and an angle of attack of 16.3°. These measurements were made at corresponding free-stream Reynolds numbers of 2.45 × 10 6 and 1.31 × 10 6 per foot (8.04 × 10 6 and 4.30 × 10 6 per meter). Experimental heat-transfer coefficients derived from temperatures obtained from 200 recording thermocouples on the skin of the airplane are tabulated. Correlations with wind-tunnel results show that the wind-tunnel data are in fair-to-good agreement with the flight data obtained on the wing, ventral tail, and vertical tail at low angles of attack but are generally in poor agreement with the high-angle-of-attack data and the low-angle-of-attack fuselage data.

Robert D Quinn↗

Single-Tip Probe Senses Pressure Or Temperature

Single-tip probe designed for use in supersonic wind tunnel switched to sense pressure or temperature measurements nearly simultaneous at that point. Includes small valve like valves used in bicycle and automotive tires, called "Schraeder valve". Tire valve opened or closed by push rod and solenoid. In open position, flow past thermocouple enables measurements of temperature. In closed position, flow blocked and pressure in probe backs up to pressure transducer.

Trimarchi, Paul↗

Gauge Measures Hot Erosion Of Insulation

Compact ladder networks containing thermocouples and resistors serve as gauges to measure erosion of insulating materials by hot, flowing gases. Designed for use in blast tubes during tests of rocket motors. Concept readily specialized to other applications in which insulation subject to erosion.

Gould, Reginald J.↗

High-Output Heat-Flux Gauges

Heat-flux gauges of proposed type put out relatively large signal voltages. Thermocouples in N top-surface/bottom-surface pairs connected in series put out N times voltage of conventional (N=1) pair on insulating layer of same thickness at same heat flux. Useful in such applications as engine instrumentation and radiation-measuring equipment.

Will, Herbert A.↗

Heat flux microsensor measurements and calibrations

A new thin-film heat flux gage has been fabricated specifically for severe high temperature operation using platinum and platinum-10 percent rhodium for the thermocouple elements. Radiation calibrations of this gage were performed at the AEDC facility over the available heat flux range (approx. 1.0 - 1,000 W/cu cm). The gage output was linear with heat flux with a slight increase in sensitivity with increasing surface temperature. Survivability of gages was demonstrated in quench tests from 500 C into liquid nitrogen. Successful operation of gages to surface temperatures of 750 C has been achieved. No additional cooling of the gages is required because the gages are always at the same temperature as the substrate material. A video of oxyacetylene flame tests with real-time heat flux and temperature output is available.

Terrell, James P.↗

High-temperature strain measurement techniques: Current developments and challenges

Since 1987, a very substantial amount of R&D has been conducted in an attempt to develop reliable strain sensors for the measurements of structural strains during ground testing and hypersonic flight, at temperatures up to at least 2000 deg F. Much of the effort has been focused on requirements of the NASP Program. This presentation is limited to the current sensor development work and characterization studies carried out within that program. It is basically an assessment as to where we are now and what remains to be done in the way of technical accomplishments to meet the technical challenges posed by the requirements and constraints established for the NASP Program. The approach for meeting those requirements and constraints has been multi-disciplinary in nature. It was recognized early on that no one sensor could meet all these requirements and constraints, largely because of the large temperature range (cryogenic to at least 2000 deg F) and many other factors, including the most challenging requirement that the sensor system be capable of obtaining valid 'first cycle data'. Present candidate alloys for resistance-type strain gages include Fe-Cr-Al and Pd-Cr. Although they have superior properties regarding withstanding very high temperatures, they exhibit large apparent strains that must either be accounted for or cancelled out by various techniques, including the use of a dual-element, half-bridge dummy gage, or electrical compensation networks. A significant effort is being devoted to developing, refining, and evaluating the effectiveness of those techniques over a broad range in temperature and time. In the quest to obtain first-cycle data, ways must be found to eliminate the need to prestabilize or precondition the strain gage, before it is attached to the test article. It should be noted that present NASP constraints do not permit prestabilization of the sensor, in situ. Gages are currently being 'heat treated' during manufacture in both the wire- and foil-type resistance strain gages, and evaluation is in progress. In addition, the 'gage-on-shim' concept is being revisited. That concept will permit heat treatment of the gage during manufacture, before attachment on the test article. Also, it may permit the individual calibration of each gage regarding gage factor and apparent strain. Candidate alloys for the NASP include titanium metal-matrix and carbon-carbon composites. Although those materials have very attractive properties at elevated temperatures in terms of strength and weight, they pose significant attachment problems. Methods for making reliable strain gage and thermocouple attachments to them are currently under development. Experience to date indicates that Rokide attachment of the sensor directly to the protective coating is easier than to the base material itself. However, interpreting strain data from gages attached in this way may prove difficult because of possible cracks in the coating that form 'islands' and the mobility of those 'islands'. It is concluded, therefore, that major technical challenges lie ahead as we proceed to meet the stringent strain sensor requirements and constraints of the NASP Program.

Lemcoe, M. M.↗

A new approach for data acquisition at the JPL space simulators

In 1990, a personal computer based data acquisition system was put into service for the Space Simulators and Environmental Test Laboratory at the Jet Propulsion Laboratory (JPL) in Pasadena, California. The new system replaced an outdated minicomputer system which had been in use since 1980. This new data acquisition system was designed and built by JPL for the specific task of acquiring thermal test data in support of space simulation and thermal vacuum testing at JPL. The data acquisition system was designed using powerful personal computers and local-area-network (LAN) technology. Reliability, expandability, and maintainability were some of the most important criteria in the design of the data system and in the selection of hardware and software components. The data acquisition system is used to record both test chamber operational data and thermal data from the unit under test. Tests are conducted in numerous small thermal vacuum chambers and in the large solar simulator and range in size from individual components using only 2 or 3 thermocouples to entire planetary spacecraft requiring in excess of 1200 channels of test data. The system supports several of these tests running concurrently. The previous data system is described along with reasons for its replacement, the types of data acquired, the new data system, and the benefits obtained from the new system including information on tests performed to date.

Fisher, Terry C.↗

Experiments on a round turbulent buoyant plume

This paper reports a comprehensive set of hot-wire measurements of a round buoyant plume which was generated by forcing a jet of hot air vertically up into quiescent environment. The boundary conditions of the experiment were measured, and are documented in the present paper in an attempt to sort out the contradictory mean flow results from the earlier studies. The ambient temperature was monitored to insure that the facility was not stratified and that the experiment was conducted in a neutral environment. The axisymmetry of the flow was checked by using a planar array of sixteen thermocouples and the mean temperature measurements from these are used to supplement the hot-wire measurements. The source flow conditions were measured so as to ascertain the rate at which the buoyancy was added to the flow. The measurements conserve buoyancy within 10 percent. The results are used to carry out the balances of the mean energy and momentum differential equations. In the mean energy equation it is found that the vertical advection of the energy is primarily balanced by the radial turbulent transport. In the mean momentum equation the vertical advection of momentum and the buoyancy force balance the radial turbulent transport. The buoyancy force is the second largest term in this balance and is responsible for the wider (and higher) velocity profiles in plumes as compared to jets. Budgets of the temperature variance and turbulence kinetic energy are also carried out in which thermal and mechanical dissipation rates are obtained as the closing terms. Similarities and differences between the two balances are discussed. It is found that even though the direct affect of buoyancy on turbulence, as evidenced by the buoyancy production term, is substantial, most of the turbulence is produced by shear. This is in contrast to the mean velocity field where the affect of buoyancy force is quite strong. Therefore, it is concluded that in a buoyant plume the primary affect of buoyancy on turbulence is indirect, and enters through the mean velocity field (giving larger shear production).

Shabbir, Aamir↗