Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods

Purpose: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). Methods: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. Results: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V{sub 95%} increased from 90% to 96% and V{sub 107%} decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. Conclusions: MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-605: Performance Evaluation of MLC Leaf-Sequencing Algorithms in Head-And-Neck IMRT

Purpose: To investigate the efficiency of three multileaf collimator (MLC) leaf-sequencing algorithms proposed by Galvin et al, Chen et al and Siochi et al using external beam treatment plans for head-and-neck intensity modulated radiation therapy (IMRT). Methods: IMRT plans for head-and-neck were created using the CORVUS treatment planning system. The plans were optimized and the fluence maps for all photon beams determined. Three different MLC leaf-sequencing algorithms based on Galvin et al, Chen et al and Siochi et al were used to calculate the final photon segmental fields and their monitor units in delivery. For comparison purpose, the maximum intensity of fluence map was kept constant in different plans. The number of beam segments and total number of monitor units were calculated for the three algorithms. Results: From results of number of beam segments and total number of monitor units, we found that algorithm of Galvin et al had the largest number of monitor unit which was about 70% larger than the other two algorithms. Moreover, both algorithms of Galvin et al and Siochi et al have relatively lower number of beam segment compared to Chen et al. Although values of number of beam segment and total number of monitor unit calculated by different algorithms varied with the head-and-neck plans, it can be seen that algorithms of Galvin et al and Siochi et al performed well with a lower number of beam segment, though algorithm of Galvin et al had a larger total number of monitor units than Siochi et al. Conclusion: Although performance of the leaf-sequencing algorithm varied with different IMRT plans having different fluence maps, an evaluation is possible based on the calculated number of beam segment and monitor unit. In this study, algorithm by Siochi et al was found to be more efficient in the head-and-neck IMRT. The Project Sponsored by the Fundamental Research Funds for the Central Universities (J2014HGXJ0094) and the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interobserver variability in identification of breast tumors in MRI and its implications for prognostic biomarkers and radiogenomics

Purpose: To assess the interobserver variability of readers when outlining breast tumors in MRI, study the reasons behind the variability, and quantify the effect of the variability on algorithmic imaging features extracted from breast MRI. Methods: Four readers annotated breast tumors from the MRI examinations of 50 patients from one institution using a bounding box to indicate a tumor. All of the annotated tumors were biopsy proven cancers. The similarity of bounding boxes was analyzed using Dice coefficients. An automatic tumor segmentation algorithm was used to segment tumors from the readers’ annotations. The segmented tumors were then compared between readers using Dice coefficients as the similarity metric. Cases showing high interobserver variability (average Dice coefficient <0.8) after segmentation were analyzed by a panel of radiologists to identify the reasons causing the low level of agreement. Furthermore, an imaging feature, quantifying tumor and breast tissue enhancement dynamics, was extracted from each segmented tumor for a patient. Pearson’s correlation coefficients were computed between the features for each pair of readers to assess the effect of the annotation on the feature values. Finally, the authors quantified the extent of variation in feature values caused by each of the individual reasons for low agreement. Results: The average agreement between readers in terms of the overlap (Dice coefficient) of the bounding box was 0.60. Automatic segmentation of tumor improved the average Dice coefficient for 92% of the cases to the average value of 0.77. The mean agreement between readers expressed by the correlation coefficient for the imaging feature was 0.96. Conclusions: There is a moderate variability between readers when identifying the rectangular outline of breast tumors on MRI. This variability is alleviated by the automatic segmentation of the tumors. Furthermore, the moderate interobserver variability in terms of the bounding box does not translate into a considerable variability in terms of assessment of enhancement dynamics. The authors propose some additional ways to further reduce the interobserver variability.

60 APPLIED LIFE SCIENCES↗

MO-DE-207B-10: Impact of Morphologic Characteristics On Radiomics Features From Contast-Enhanced CT for Primary Lung Tumors

Purpose: Determine the impact of morphologic characteristics (e.g. necrosis, vascular enhancement, and cavitation) on radiomic features from contrast enhanced CT (CE-CT) in primary lung tumors. Methods: We developed an auto-segmentation algorithm to separate lung tumors on contrast-enhanced CT into cavitation (air), necrosis, tissue, and enhancing vessels using a combination of thresholding and region-growing. An auto-segmentation algorithm was also designed to identify necrosis on FDG-PET scans. Wilcoxon rank-sum tests were used to determine if significant differences existed in radiomics features (histogram-uniformity and Laplacian-of-Gaussian average) from 249 patients, found to prognostic in previous work, based on the presence/absence of morphologic features. Feature values were also compared between the original tumor contours and contours excluding a specific morphologic feature. Comparison of necrosis segmentation on CE-CT versus FDG-PET was performed in 78 patients to assess for agreement using the concordance correlation coefficient (CCC). Results: Tumors with cavitation and enhancing vasculature had lower uniformity values (p = 0.001 and p = 0.03, respectively). Tumors with enhancing vasculature and necrosis had higher Laplacian-of-Gaussian average values (measure of “edges” within the tumor) (p < 0.001). Removing these tissue types from regions-of-interest did not drastically alter either radiomic feature value (all scenarios had R{sup 2} > 0.8). This suggests there may be interactions between morphologic characteristics and the radiomic feature value of tumor tissue. Comparison of necrosis volume and percent necrosis volume of tumor were found to have CCC values of 0.85 and 0.76, respectively between CE-CT and FDG-PET segmentation methods. Conclusions: Tumors with enhancing vasculature, necrosis, and cavitation have higher radiomic feature values that are associated with poor prognosis than tumors without these features. Removing these tissue types from quantitative assessment did not drastically impact radiomic feature values. High reproducibility of CE-CT segmented necrosis compared to FDG-PET segmented necrosis provides a reasonable validation of segmentation accuracy on CE-CT.

60 APPLIED LIFE SCIENCES↗

Performance Improvements to the Prototype Design of the AGU

The existing design for the Magnet Structure of the prototype multi-segment AGU (Adaptive- Gap Undulator) has undergone analysis (see TN #298). To optimize performance, after review of said analysis, certain design modifications are proposed herein. A primary constraint of this proposed design is to use the existing fabricated parts from initial assembly SR-ID-SAGU-4300 with three pairs of feed-throughs spaced along the platen length of a single segment, but with foresight for the eventual multi-segment prototype. Measurements of the center segment are to be conducted on the frame and gap-drive system of the NSLS X9 MGU with its single driven axis. The eventual multi-segment prototype will also use the sister devices (X13, X27) for simultaneous measurement of both central and outboard segments at various segment gaps. Criteria effecting IVU performance like Gap Tolerance, Taper Error, and the critical Planarity of pole plane as in Figure 1 are used to evaluate the design. The error in planarity to be minimized is the deviation of vertical displacement (Y direction) with Platen length (beam Z direction).

36 MATERIALS SCIENCE↗

Tank 22 Settled Sludge Core Sample Characterization and Testing

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) Engineering (SRR-E) to provide sample characterization and analyses of Tank 22 settled sludge core sample and the supernatant liquids (supernate) in support of Tank 22 re-baseline data, inhalation dose potential/hydrogen generation and suspension/removal of settled sludge from the bottom of Tank 22. The approximately 9.5 inches of intact Tank 22 core sample from SRR-E, after extrusion in the SRNL Shielded Cells, showed three visually different stratification layers or regions of solids in the extruded core material. Part of the initial physical characterization of these three segments of the Tank 22 core sample included density, weight percent total solids, particle size distribution, X-ray diffractions and scanning electron microscope of each segment material. Given the dissimilarity of the three Tank 22 segment materials after the physical characterization results and the fact that there was no clear line of demarcation to indicate where each segment began and ended across the entire length of the core sample, SRNL in conjunction with the SRR-E customer decided to blend all three segments of the material to form a composite Tank 22 core sample for further analysis and characterization without taking into consideration the proportional weight or mass contribution of each segment. This compositing approach assumes that the errors introduced in any characterization of the Tank 22 core sample will be comparable to the errors when the three segments are separated and combined proportionally by weight to form the composite Tank 22 sample. This compositing approach maximized the quantity of composited Tank 22 material needed for radionuclide and other physical characterizations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanowire structures and electrical devices

The present invention provides structures and devices comprising conductive segments and conductance constricting segments of a nanowire, such as metallic, superconducting or semiconducting nanowire. The present invention provides structures and devices comprising conductive nanowire segments and conductance constricting nanowire segments having accurately selected phases including crystalline and amorphous states, compositions, morphologies and physical dimensions, including selected cross sectional dimensions, shapes and lengths along the length of a nanowire. Further, the present invention provides methods of processing nanowires capable of patterning a nanowire to form a plurality of conductance constricting segments having selected positions along the length of a nanowire, including conductance constricting segments having reduced cross sectional dimensions and conductance constricting segments comprising one or more insulating materials such as metal oxides.

Bezryadin, Alexey↗

Electrical machine

In one embodiment, an apparatus includes a rotor shaft, at least one pole segment, at least one pole tip segment and at least one permanent magnet pair. The at least one pole segment is mechanically coupled to the rotor shaft. Each permanent magnet pair is disposed between the at least one pole segment and respective pole tip segment. The apparatus further includes at least one mechanical member that mechically restrains the at least one pole tip segment to at least one of the rotor shaft or the at least one pole segment.

42 ENGINEERING↗

Identification of uncommon objects in containers

A system for identifying in an image an object that is commonly found in a collection of images and for identifying a portion of an image that represents an object based on a consensus analysis of segmentations of the image. The system collects images of containers that contain objects for generating a collection of common objects within the containers. To process the images, the system generates a segmentation of each image. The image analysis system may also generate multiple segmentations for each image by introducing variations in the selection of voxels to be merged into a segment. The system then generates clusters of the segments based on similarity among the segments. Each cluster represents a common object found in the containers. Once the clustering is complete, the system may be used to identify common objects in images of new containers based on similarity between segments of images and the clusters.

97 MATHEMATICS AND COMPUTING↗

Identification of uncommon objects in containers

A system for identifying in an image an object that is commonly found in a collection of images and for identifying a portion of an image that represents an object based on a consensus analysis of segmentations of the image. The system collects images of containers that contain objects for generating a collection of common objects within the containers. To process the images, the system generates a segmentation of each image. The image analysis system may also generate multiple segmentations for each image by introducing variations in the selection of voxels to be merged into a segment. The system then generates clusters of the segments based on similarity among the segments. Each cluster represents a common object found in the containers. Once the clustering is complete, the system may be used to identify common objects in images of new containers based on similarity between segments of images and the clusters.

97 MATHEMATICS AND COMPUTING↗

Vertically oriented seal system for gas turbine vanes

A seal system for a gas turbine vane includes a first seal layer and an optional second seal layer. Each first seal layer includes multiple seal segments, each of which includes a first leg, a second leg, and an intermediate portion between the first leg and the second leg. Each adjacent pair of seal segments of the first seal is separated by a gap. The seal segments define a substantially complete perimeter of a seal slot in which the first seal is installed. The second seal, which is also segmented, may or may not define the substantially complete perimeter of the seal slot. If present, the second seal segments are circumferentially offset from the first seal segments to block the gaps between the first seal segments. A turbine vane including the present seal system is also disclosed.

42 ENGINEERING↗

Apparatus and method for assembling a pumping tube into an air maintenance tire sidewall groove

Apparatus and method of assembling an elongate air pumping tube into an elongate tire sidewall groove includes engaging the tire sidewall outward surface with an impact wheel at an impact location proximally adjacent and above the elongate groove as the tire is rotated. The groove is thereby spread segment-by-segment for segment-by-segment synchronous insertion of the tube into the groove. The groove is closed segment-by-segment as each spread segment is returned to its original narrower dimension utilizing elastomeric material composition properties of the tire sidewall.

42 ENGINEERING↗

Recuperator assembly and procedures

A construction of recuperator core segments is provided which insures proper assembly of the components of the recuperator core segment, and of a plurality of recuperator core segments. Each recuperator core segment must be constructed so as to prevent nesting of fin folds of the adjacent heat exchanger foils of the recuperator core segment. A plurality of recuperator core segments must be assembled together so as to prevent nesting of adjacent fin folds of adjacent recuperator core segments.

42 ENGINEERING↗

Element for use in an inductive coupler for downhole components

An element for use in an inductive coupler for downhole components comprises an annular housing having a generally circular recess. The element further comprises a plurality of generally linear, magnetically conductive segments. Each segment includes a bottom portion, an inner wall portion, and an outer wall portion. The portions together define a generally linear trough from a first end to a second end of each segment. The segments are arranged adjacent to each other within the housing recess to form a generally circular trough. The ends of at least half of the segments are shaped such that the first end of one of the segments is complementary in form to the second end of an adjacent segment. In one embodiment, all of the ends are angled. Preferably, the first ends are angled with the same angle and the second ends are angled with the complementary angle.

47 OTHER INSTRUMENTATION↗

Toward Reconciling Magnitude Discrepancies Estimated from Paleoearthquake Data

We recognize a discrepancy in magnitudes estimated for several Basin and Range, U.S.A. faults. For example, magnitudes predicted for the Wasatch (Utah), Lost River (Idaho), and Lemhi (Idaho) faults from fault segment lengths (L{sub seg}) where lengths are defined between geometrical, structural, and/or behavioral discontinuities assumed to persistently arrest rupture, are consistently less than magnitudes calculated from displacements (D) along these same segments. For self-similarity, empirical relationships (e.g. Wells and Coppersmith, 1994) should predict consistent magnitudes (M) using diverse fault dimension values for a given fault (i.e. M {approx} L{sub seg}, should equal M {approx} D). Typically, the empirical relationships are derived from historical earthquake data and parameter values used as input into these relationships are determined from field investigations of paleoearthquakes. A commonly used assumption - grounded in the characteristic-earthquake model of Schwartz and Coppersmith (1984) - is equating L{sub seg} with surface rupture length (SRL). Many large historical events yielded secondary and/or sympathetic faulting (e.g. 1983 Borah Peak, Idaho earthquake) which are included in the measurement of SRL and used to derive empirical relationships. Therefore, calculating magnitude from the M {approx} SRL relationship using L{sub seg} as SRL leads to an underestimation of magnitude and the M {approx} L{sub seg} and M {approx} D discrepancy. Here, we propose an alternative approach to earthquake magnitude estimation involving a relationship between moment magnitude (Mw) and length, where length is L{sub seg} instead of SRL. We analyze seven historical, surface-rupturing, strike-slip and normal faulting earthquakes for which segmentation of the causative fault and displacement data are available and whose rupture included at least one entire fault segment, but not two or more. The preliminary Mw {approx} L{sub seg} results are strikingly consistent with Mw {approx} D calculations using paleoearthquake data for the Wasatch, Lost River, and Lemhi faults, demonstrating self-similarity and implying that the Mw {approx} L{sub seg} relationship should supplant M {approx} SRL relationships currently employed in seismic hazard analyses. The relationship will permit reliable use of L{sub seg} data from field investigations and proper use and weighting of multiple-segment-rupture scenarios in seismic hazard analyses, and eliminate the need to reconcile the Mw {approx} SRL and Mw {approx} D differences in a multiple-parameter relationship for segmented faults.

58 GEOSCIENCES↗

Ribonuclease A suggests how proteins self-chaperone against amyloid fiber formation

Genomic analyses have identified segments with high fiber-forming propensity in many proteins not known to form amyloid. Proteins are often protected from entering the amyloid state by molecular chaperones that permit them to fold in isolation from identical molecules; but, how do proteins self-chaperone their folding in the absence of chaperones? Here, we explore this question with the stable protein ribonuclease A (RNase A). We previously identified fiber-forming segments of amyloid-related proteins and demonstrated that insertion of these segments into the C-terminal hinge loop of nonfiber-forming RNase A can convert RNase A into the amyloid state through three-dimensional domain-swapping, where the inserted fiber-forming segments interact to create a steric zipper spine. In this study, we convert RNase A into amyloid-like fibers by increasing the loop length and hence conformational freedom of an endogenous fiber-forming segment, SSTSAASS, in the N-terminal hinge loop. This is accomplished by sandwiching SSTSAASS between inserted Gly residues. With these inserts, SSTSAASS is now able to form the steric zipper spine, allowing RNase A to form amyloid-like fibers. We show that these fibers contain RNase A molecules retaining their enzymatic activity and therefore native-like structure. Thus, RNase A appears to prevent fiber formation by limiting the conformational freedom of this fiber-forming segment from entering a steric zipper. Our observations suggest that proteins have evolved to self-chaperone by using similar protective mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

The utility of {sup 82}Rb PET for myocardial viability assessment: Comparison with perfusion-metabolism {sup 82}Rb-{sup 18}F-FDG PET

Background: {sup 82}Rb kinetics may distinguish scar from viable but dysfunctional (hibernating) myocardium. We sought to define the relationship between {sup 82}Rb kinetics and myocardial viability compared with conventional {sup 82}Rb and {sup 18}F-fluorodeoxyglucose (FDG) perfusion-metabolism PET imaging. Methods: Consecutive patients (N = 120) referred for evaluation of myocardial viability prior to revascularization and normal volunteers (N = 37) were reviewed. Dynamic {sup 82}Rb 3D PET data were acquired at rest. {sup 18}F-FDG 3D PET data were acquired after metabolic preparation using a standardized hyperinsulinemic-euglycemic clamp. {sup 82}Rb kinetic parameters K{sub 1}, k{sub 2}, and partition coefficient (KP) were estimated by compartmental modeling Results: Segmental {sup 82}Rb k{sub 2} and KP differed significantly between scarred and hibernating segments identified by Rb-FDG perfusion-metabolism (k{sub 2}, 0.42 ± 0.25 vs. 0.22 ± 0.09 min{sup −1}; P < .0001; KP, 1.33 ± 0.62 vs. 2.25 ± 0.98 ml/g; P < .0001). As compared to Rb-FDG analysis, segmental Rb KP had a c-index, sensitivity and specificity of 0.809, 76% and 84%, respectively, for distinguishing hibernating and scarred segments. Segmental k{sub 2} performed similarly, but with lower specificity (75%, P < .001) Conclusions: In this pilot study, {sup 82}Rb kinetic parameters k{sub 2} and KP, which are readily estimated using a compartmental model commonly used for myocardial blood flow, reliably differentiated hibernating myocardium and scar. Further study is necessary to evaluate their clinical utility for predicting benefit after revascularization. [French] French Abstract: Contexte: La cinétique du {sup 82}Rb pourrait être utilisée pour distinguer la fibrose myocardique des zones viables mais dysfonctionnelles (en hibernation). Dans cette étude, nous avons cherché à définir la relation entre la cinétique du {sup 82}Rb et la viabilité myocardique en comparant les images de perfusion et métabolisme myocardique utilisant le {sup 82}Rb et le {sup 18}F-fluorodésoxyglucose (FDG) Méthodes: les données obtenues chez 120 patients consécutifs (N = 120) référés pour évaluation de la viabilité du myocarde avant revascularisation et 37 volontaires considérés normaux (N = 37) ont été étudieés. Les données TEP 3D dynamiques {sup 82}Rb ont été acquises au repos. Les données TEP 3D au {sup 18}F-FDG ont été acquises après préparation métabolique utilisant une pince hyperinsulémique-euglycémique normalisée. Les paramètres k1, k2 et le coefficient de partage (KP) de la cinétique du {sup 82}R bont été évalues par modélisation compartimentale. Résultats: les paramètres k2 et KP de distribution du {sup 82}Rb se sont révélés significativement différent entre les zones tissulaires cicatricielles fibreuses et celles en hibernation identifiées par étude métabolique au FDG (k2, 0,42 ± 0,25 vs. 0,22 ± 0,09 min{sup −1}; P < 0,0001; KP, 1,33 ± 0,62 vs. 2,25 ± 0,98 ml/g; P < 0,0001). Par rapport aux données FDG, le paramètre KP du rubidium a révélé un indice de concordance de 0,809 et une sensibilité et spécificité de 76% et 84%, pour la distinction des segments en hibernation et cicatrisés. Les résultats du paramètre k2 se sont révélés similaires, mais avec une spécificité plus faible calculée à 75% (P < 0,001). Conclusions: Dans cette étude pilote, les paramètres cinétiques k2 et KP de perfusion myocardique au {sup 82}Rb, qui sont facilement estimés à l’aide d’un modèle compartimental couramment utilisé pour flux sanguin myocardique, ont permis de différencier de manière fiable le myocarde cicatricielle des zones myocardiques hibernantes. Une étude plus approfondie est souhaitable pour valider leur utilité clinique en revacularisation. [Spanish] Spanish Abstract: Antecedentes: La cinética con {sup 82}Rb puede distinguir las cicatrices miocárdicas del tejido viable pero disfuncional (hibernante). Buscamos definir la relación entre la cinética del {sup 82}Rb y la viabilidad miocárdica comparada con las imágenes convencionales de PET con {sup 82}Rb y {sup 18}F-flurodeoxyglucosa (FDG). Métodos: se evaluaron a Pacientes Consecutivos (N = 120) referidos para evaluación de viabilidad miocárdica previos a revascularización y voluntarios normales (N = 37). Los datos de PET 3D dinámico con {sup 82}Rb fueron adquiridos en reposo. Los datos de {sup 18}F-FDG 3D PET fueron adquiridos posterior a la preparación metabólica usando un clamp hiperinsulínico-euglucémico. Los patrones cinéticos K1, k2 y el coeficiente de partición (KP) fueron estimados por el modelo compartimental. Resultados: el k2 y KP del {sup 82}Rb permitueron distinguier el tejido cicatricial de los segmentos hibernados identificados por la vía perfusión metabolismo de Rb-FDG (k{sub 2}, 0.42 ± 0.25 vs. 0.22 ± 0.09 min-1; P < .0001; KP, 1.33 ± 0.62 vs. 2.25 ± 0.98 ml/g; P < .0001). En comparación con el análisis de Rb-FDG, el KP segmentario del Rb tuvo un índice-c, sensbilidad y especificidad de 0.809 76 y 84%, respectivamente, para distinguir segmentos hibernantes y cicatriciales. k2 Segmentario tuvo un desempeño similar pero con una menor especificidad (75%, P < .001). Conclusiones: En este estudio piloto, los parámetros cinéticos k2 y KP del {sup 82}Rb, los cuales son estimados usando un modelo compartimental usado comúnmente para flujo sanguíneo miocárdico, diferenciaron el miocardio hibernante del cicatricial. Se necesita estudiar más a fondo para evaluar la utilidad clínica para la predicción del beneficio posterior a la revascularización [Chinese] Chinese Abstract: 背景: 铷-82({sup 82}Rb)药代动力学可能区分梗死与功能受损但存活的心肌(冬眠心肌)。我们将探讨{sup 82}Rb药代动力学与存活心肌的关系,并与常规的{sup 82}Rb和{sup 18}F-氟脱氧葡萄糖(FDG)灌注-代谢PET显像进行比较。 方法: 连续纳入120名血运重建前评估存活心肌的患者和37名正常志愿者。获得静息{sup 82}Rb 3D-PET动态采集数据;采用标准化的高胰岛素 - 正葡萄糖钳夹试验得到{sup 18}F-FDG 3D PET代谢显像数据; 通过房室模型计算{sup 82}Rb动力学参数k{sub 1},k{sub 2}和分配系数(KP)。 结果: 以Rb-FDG灌注代谢显像鉴定疤痕心肌组和冬眠心肌组,两组的{sup 82}Rb节段性 k{sub 2}值和KP值有明显差异(k{sub 2}, 0.42 ± 0.25 vs 0.22 ± 0.09 min{sup −1}; P < .0001; KP, 1.33 ± 0.62 vs 2.25 ± 0.98 ml/g; P < .0001)。以Rb-FDG灌注代谢显像为诊断标准,{sup 82}Rb节段性 KP对疤痕和冬眠心肌鉴别效能的c指数,敏感性和特异性分别是0.809, 76%和84%。节段性k{sub 2}的鉴别效能与KP相似,但特异性较低(75%,P < .001)。 结论: 在本试验性研究中,通过常规用于{sup 82}Rb心肌血流量测定的房室模型计算出的{sup 82}Rb动力学参数k{sub 2}和KP,可以有效的区分冬眠心肌和瘢痕心肌。 但需要进一步的研究来评估其对预测血运重建是否获益的临床价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Segmentectomy: A Novel Approach to Increase Safety and Efficacy of Radioembolization

Purpose: To describe a technique of segmental radioembolization for the treatment of patients with unresectable hepatocellular carcinoma (HCC). Radiation segmentectomy was defined as radioembolization of two or fewer hepatic segments. We sought to (1) calculate dose when activity is delivered segmentally assuming uniform and nonuniform distribution and, (2) determine safety and efficacy of this novel technique. Methods and Materials: A total of 84 patients with HCC who were treated with {sup 90}Y radioembolization using a segmental approach were included in this analysis. The dose delivered to the segment was calculated assuming uniform and nonuniform microsphere distribution within the treatment volume. To calculate dose assuming nonuniform distribution, a tumor hypervascularity ratio was assigned. Posttreatment response (using size and necrosis guidelines), toxicity, time to progression, and survival were determined. Results: The median treatment volume was 110 cm{sup 3}. The median radiation-naive liver volume was 1403 cm{sup 3}. The median dose delivered to the segment(s) assuming uniform distribution was 521 Gy. Taking into account tumor hypervascularity (nonuniform distribution), the median dose delivered to the tumor and normal infused hepatic volume was 1214 Gy and 210 Gy, respectively. Response by size and necrosis guidelines was seen in 59% and 81% of patients. Grade 3/4 biochemical toxicities were observed in 8 patients (9%). Median time to progression was 13.6 months (95% confidence interval, 9.3-18.7 months); median survival was 26.9 months (95% confidence interval, 20.5-30.2 months). Conclusions: Radiation segmentectomy is a safe and efficacious method of selectively delivering high dose to the tumor with minimal exposure of normal parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗