Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Present status of SPring-8 macromolecular crystallography beamlines

Seven beamlines are operated for macromolecular crystallography (MX) at SPring-8. The three undulator beamlines are developed for cutting edge target and four bending-magnet beamlines are developed for high throughput MX. The undulator beamline, BL41XU that provides the most brilliant beam, is dedicated to obtain high quality data even from small-size and weakly-diffracting crystals. The minimum beam size at sample position is achieved to 10 {mu}m diameter using a pin-hole collimator. Its photon flux at wavelength {lambda} = 1.0 A is 2.8x10{sup 11} photons/sec. This small beam coupled with irradiation point scanning method is quite useful to take diffraction dataset from small crystals by suppressing the radiation damage. These advanced technologies made a number of difficult protein structure analysis possible, (i.e. Sodium-potassium ATPase). The bending-magnet beamlines BL26B1/B2 and BL38B1 provide automatic data collection exploiting the high mobility of the beam. The beamline operation software 'BSS', sample auto-changer 'SPACE' and web-based data management software 'D-Cha' have made the automatic data collection possible. The 'Mail-in data collection system' that accepts distant users samples via courier service have made users possible to collect diffraction data without visiting SPring-8. The structural genomics research is promoted by these beamlines.

43 PARTICLE ACCELERATORS↗

Overview of the SPring-8 Diagnostics Beamlines

We present an overview of the two SPring-8 diagnostics beamlines, the beamline I (dipole magnet source) and II (insertion device source). At the beamline I, synchrotron radiation (SR) in both the X-ray and the visible bands is exploited for characterizations of the electron beam. At the beamline II, by observing the spectral, spatial, and temporal characteristics of X-ray SR of the insertion device (ID), new techniques for accelerator diagnostics are investigated. Irradiation experiments with the ID to develop accelerator components such as photon absorbers, and production of intensive 10 MeV {gamma}-rays by backward Compton scattering of external far infrared (FIR) laser photons are being prepared at the beamline II.

43 PARTICLE ACCELERATORS↗

Present Status of the NIMS Contract Beamline BL15XU at SPring-8

The revolver undulator beamline BL15XU at SPring-8, which is the contract beamline of National Institute for Materials Science (NIMS), was established for materials science using soft-and-hard X-ray photoelectron spectroscopy (XPS) and high-resolution powder X-ray diffraction (XRD). We have performed beamline reconstruction for further developments of the experiments in the research field of materials science. The flat double-crystal monochromator (DCM) with liquid nitrogen cooling, X-ray total reflection double-mirror system with (+,-) geometry, and high-energy-resolution channel-cut monochromator have been installed into the beamline. The refined beamline provides monochromatic X-rays from 2 to 36 keV. The improvement of the photon flux density at the XRD and XPS experimental stations was confirmed. The photon flux was estimated to be several 10{sup 12} photons/sec with {Delta}E/E of {approx}10{sup -4}.

43 PARTICLE ACCELERATORS↗

Characterizations and Applications of the Insertion Device of the SPring-8 Diagnostics Beamline II

An insertion device (ID05) of the SPring-8 diagnostics beamline II (BL05SS) was characterized from the aspects of both the magnetic field performance and the spectral performance as a high K wiggler, which was confirmed to have the field performance with the rms phase error less than 2 degree. Meanwhile, the spectral performance of ID05 as an undulator with small K was also investigated by the energy spectrum measurements. The rms phase error less than 2degree leads us to apply the wiggler radiation on the higher harmonics to the beam diagnostics. We successfully demonstrated an application to the energy-spread diagnostics of electron beam using the 19th harmonics.

43 PARTICLE ACCELERATORS↗

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

The Advanced Automation for Powder Diffraction toward Industrial Application

A highly automated system for powder diffraction with synchrotron radiation was installed on the large Debye-Scherrer camera at the BL19B2 Engineering Science Research I beamline of SPring-8. Combined with a sample transfer and an automated centering system, we have succeeded in increasing the ratio of exposure time in the user beam time to 85%. The proposed system can be applied to a wide range of industrial uses.

43 PARTICLE ACCELERATORS↗

Dosimetry And Its Enhancement Using Gold Nanoparticles In Synchrotron Based Microbeam And Stereotactic Radiosurgery

Research into the areas of synchrotron generated microbeam radiotherapy (MRT) and stereotactic radiosurgery is increasing. Such MRT techniques are showing potential of tackling some of the more difficult radiotherapy cases such as certain type of brain tumours. Two challenging aspects of these techniques are addressed in this investigation; the difficulty of dose determination and the delivery of the treatments at lower dose levels. In this research polymer gels were used as phantoms and dosimeters and cells were used to confirm outcomes. Normoxic polyacrylamide gels (nPAG) were tested as potential dosimeters for microbeam dosimetry. Following irradiation using microbeam and minibeam radiation from the BL28BU beam-line at Spring-8, Japan, the nPAG were scanned using a Raman spectroscopy technique. Dose enhancement caused by the inclusion of the gold nanoparticles (AuNPs) in the target was investigated using both cells and polymer gels. The use of AuNP could potentially reduce the dose required for the delivery of MRT. In this study it was shown that using endothelial cells with AuNPs, the minimal dose for clear cell killing along the beam line was reduced to 10 Gy. Both studies cell and gel studies indicates significant dose enhancement caused by the gold atoms in the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction of Spherical Aberration in Grazing-Incidence X-ray Optics by Combination of Spherical-Concave Mirrors

In grazing-incidence total-reflection mirror optics for x-rays, spherical aberrations and coma are the most serious aberrations for microfocusing and microimaging. High-resolution imaging is believed to be possible only when an aspherical mirror system is used. However, the spherical aberrations of a spherical-concave mirror in a grazing-incidence condition can be eliminated by sequential reflection of spherical mirrors of similar shapes. A sub-micrometer one-dimensional focusing is easily achieved by the spherical-aberration-corrected tandem-spherical mirror optics. By configuring four spherical mirrors in an analogy of the crossed mirror optics (Kirkpatrick-Baez optics), it is possible to achieve sub-micrometer focused beam size in the hard x-ray region. Preliminary experiments on x-ray microfocusing have been carried out at beamline 20XU of SPring-8, and a 0.5 {mu}mx0.4 {mu}m beam size was achieved at 8 keV.

07 ISOTOPE AND RADIATION SOURCES↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Long-Working-Distance Kirkpatrick-Baez Mirrors for Hard X-ray Beamlines at SPring-8

We designed and installed two types of long-working-distance Kirkpatrick-Baez (KB) mirrors and mirror manipulators, which were customized into each experiment for hard x-ray undulator beamlines at SPring-8. For the BL32XU RIKEN Targeted Proteins beamline, 400-mm-long KB focusing mirrors for a beam size of 1 {mu}m with a 730-mm-long working distance were designed for carrying out the structural analysis of protein microcrystals. We realized a focusing beam size of 0.9x0.9 {mu}m{sup 2}(FWHM) and a focusing intensity of 6x10{sup 10} (photons/s) at an x-ray energy of 12.4 keV. For the BL19LXU RIKEN SR Physics beamline, we developed KB mirrors for 100-nm focusing with a 100-mm-working distance for the purpose of nano-focus x-ray diffraction. A focusing beam size of 100x100 nm{sup 2}(FWHM) and a high focusing intensity of 3.7x10{sup 10} (photons/s) at an x-ray energy of 12.4 keV were realized.

43 PARTICLE ACCELERATORS↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

Present Status of the Nanotomography System at BL47XU at SPring-8 and Its Efficiency Improvement Using Double-Condenser Optics

Although imaging x-ray nanotomography developed at beamline BL47XU of SPring-8 has reached a spatial resolution less than 200 nm, poor intensity and low signal-to-noise ratio are more serious problems in the system using zone plate optics. Improvement of the diffraction efficiency of Koehler illumination optics is attempted by doubling two condenser zone plates, which have a constant grating pitch of 200 nm. Although a long longitudinal distance between two condensers is possible ({approx}100 mm), efficiency varies periodically as the distance is changed due to the Talbot effect. A maximum efficiency close to 0.3 is obtained with a periodic distance of approximately 500 {mu}m.

43 PARTICLE ACCELERATORS↗