Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STANDARDIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

R K and future b → s ℓ ℓ physics beyond the standard model opportunities

Flavor changing neutral current |ΔB|=|ΔS|=1 processes are sensitive to possible new physics at the electroweak scale and beyond, providing detailed information about flavor, chirality and Lorentz structure. Recently the LHCb collaboration announced a 2.6σ deviation in the measurement of $R_K={\cal{B}}(\bar B \to \bar K \mu \mu)/{\cal{B}}(\bar B \to \bar K ee)$ from the standard model's prediction of lepton universality. We identify dimension six operators which could explain this deviation and study constraints from other measurements. Vector and axial-vector four-fermion operators with flavor structure $\bar s b \bar \ell \ell$ can provide a good description of the data. Tensor operators cannot describe the data. Pseudo-scalar and scalar operators only fit the data with some fine-tuning; they can be further probed with the $\bar B \to \bar K ee$ angular distribution. The data appears to point towards $C_9^{\rm NP \mu} = -C_{10}^{\rm NP \mu }<0$, an $SU(2)_{L}$ invariant direction in parameter space supported by R K , the $\bar B \to \bar K^* \mu \mu$ forward-backward asymmetry and the $\bar B_s \to \mu \mu$ branching ratio, which is currently allowed to be smaller than the standard model prediction. We present two leptoquark models which can explain the FCNC data and give predictions for the LHC and rare decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs boson mass in the standard model at two-loop order and beyond

We calculate the mass of the Higgs boson in the standard model in terms of the underlying Lagrangian parameters at complete 2-loop order with leading 3-loop corrections. A computer program implementing the results is provided. The program also computes and minimizes the standard model effective potential in Landau gauge at 2-loop order with leading 3-loop corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining the top-Higgs sector of the standard model effective field theory

Working in the framework of the Standard Model effective field theory, we study chirality-flipping couplings of the top quark to Higgs and gauge bosons. In this paper, we discuss in detail the renormalization-group evolution to lower energies and investigate direct and indirect contributions to high- and low-energy $CP$-conserving and $CP$-violating observables. Our analysis includes constraints from collider observables, precision electroweak tests, flavor physics, and electric dipole moments. We find that indirect probes are competitive or dominant for both $CP$-even and $CP$-odd observables, even after accounting for uncertainties associated with hadronic and nuclear matrix elements, illustrating the importance of including operator mixing in constraining the Standard Model effective field theory. We also study scenarios where multiple anomalous top couplings are generated at the high scale, showing that while the bounds on individual couplings relax, strong correlations among couplings survive. In conclusion, we find that enforcing minimal flavor violation does not significantly affect the bounds on the top couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complete asymptotically safe embedding of the standard model

We introduce and discuss the “Tetrad Model”, a large color/flavor embedding of the Standard model which has an interacting ultraviolet fixed point. It is demonstrated that its extended-Pati-Salam symmetry is broken radiatively via the Coleman-Weinberg mechanism, while the remaining electroweak symmetry is broken when mass-squared terms run negative. In the IR the theory yields just the Standard Model, augmented by the fact that the Higgs fields carry the same generation indices as the matter fields. It is also shown that the Higgs mass-squareds develop a hierarchical structure in the IR, from a UV theory that is asymptotically flavor symmetric, opening up an interesting direction for explaining the emergence of the observed flavor structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Converting Clinical Pathways to BPM+ Standards: A Case Study in Stable Ischemic Heart Disease

Clinical pathways (CPs) are structured healthcare plans designed to implement evidence-based clinical guidelines, medical algorithms, and protocols. In recent years, a community called BPM+ Health has worked to establish a shareable and computer-consumable representation of CP, leveraging standard notations. These notations, collectively referred to as BPM+, include the Business Process Management and Notation (BPMN), Case Management Model and Notation (CMMN), and Decision Model and Notation (DMN), which aim to support clinical management and standardized communication between different stakeholders. However, the adaptation of these notations for the existing guidelines has largely been left unexplored. This paper introduces procedural steps and criteria considerations to apply components of BPM+ notations to reconstruct a guideline for Stable Ischemic Heart Disease. This paper describes how each of the three different notations is mapped to a medical guideline and discusses the advantages and limitations of representing CPs with BPM+ as compared with paper-based medical guidelines.

Chae, Junghoon↗

Evolution of the IEEE P7009 Standard: Towards Fail-Safe Design of Autonomous Systems

Autonomous systems are complex, diverse, and likely be used in environments that change unpredictably. We must develop mechanisms to cope with failures, potentially caused by both the natural stresses of the operating environment and the system's inadequate environmental models. Failures also arise from system component wear. In 2016, the IEEE launched the Global Initiative on Ethics of Autonomous and Intelligent Systems in response to the proliferation of increasingly-autonomous systems. A cornerstone of this initiative is the IEEE P7000 series of projects, which set the standards for the future of ethical intelligent and autonomous technologies. This paper describes the ongoing development of the IEEE P7009 standard on “Fail-Safe Design of Autonomous and Semi-Autonomous Systems”. We provide a collective perspective on the ongoing development of IEEE P7009, and outline the objectives, current approaches, issues under discussion, and two exemplar use cases from different sectors: one high-regulation, the other low-regulation.

Farrell, Marie↗

Changes Required in the PMU standards

The Phasor Measurement Unit (PMU) is a representational measuring instrument that gives time-stamped measurements of the power system on the assumption that the measurand can be represented as sinusoidal. However, two standards defining the measured quantities unnecessarily corrupt the results and limit the capabilities of the PMU, and are beginning to tax communications systems. This paper examines the two mistakes in the PMU standards, and proposes a solution.

PMU measurement, phase, phasor, measurement theory↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed, but is more superiorly located at T12-L1 for SAT and at L3-L4 for VAT. Furthermore, the optimal anatomic locations for SAT and VAT estimation are not the same, contrary to common assumption. The proposed standardized space mapping achieves high consistency of anatomic localization by accurately managing nonlinearities in the relationships among landmarks. Multiple slices achieve greater improvement in correlation for VAT than for SAT. The optimal locations in the case of multiple slices are not contiguous.

60 APPLIED LIFE SCIENCES↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-276: Dose Calculation Accuracy with a Standard Beam Model for Extended SSD Treatments

Purpose: While most photon treatments are delivered near 100cm SSD or less, a subset of patients may benefit from treatment at SSDs greater than 100cm. A proposed rotating chair for upright treatments would enable isocentric treatments at extended SSDs. The purpose of this study was to assess the accuracy of the Pinnacle{sup 3} treatment planning system dose calculation for standard beam geometries delivered at extended SSDs with a beam model commissioned at 100cm SSD. Methods: Dose to a water phantom at 100, 110, and 120cm SSD was calculated with the Pinnacle {sup 3} CC convolve algorithm for 6x beams for 5×5, 10×10, 20×20, and 30×30cm{sup 2} field sizes (defined at the water surface for each SSD). PDDs and profiles (depths of 1.5, 12.5, and 22cm) were compared to measurements in water with an ionization chamber. Point-by-point agreement was analyzed, as well as agreement in field size defined by the 50% isodose. Results: The deviations of the calculated PDDs from measurement, analyzed from depth of maximum dose to 23cm, were all within 1.3% for all beam geometries. In particular, the calculated PDDs at 10cm depth were all within 0.7% of measurement. For profiles, the deviations within the central 80% of the field were within 2.2% for all geometries. The field sizes all agreed within 2mm. Conclusion: The agreement of the PDDs and profiles calculated by Pinnacle3 for extended SSD geometries were within the acceptability criteria defined by Van Dyk (±2% for PDDs and ±3% for profiles). The accuracy of the calculation of more complex beam geometries at extended SSDs will be investigated to further assess the feasibility of using a standard beam model commissioned at 100cm SSD in Pinnacle3 for extended SSD treatments.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

Standards for Sequencing Viral Genomes in the Era of High-Throughput Sequencing

Thanks to high-throughput sequencing technologies, genome sequencing has become a common component in nearly all aspects of viral research; thus, we are experiencing an explosion in both the number of available genome sequences and the number of institutions producing such data. However, there are currently no common standards used to convey the quality, and therefore utility, of these various genome sequences. Here, we propose five “standard” categories that encompass all stages of viral genome finishing, and we define them using simple criteria that are agnostic to the technology used for sequencing. We also provide genome finishing recommendations for various downstream applications, keeping in mind the cost-benefit trade-offs associated with different levels of finishing. Our goal is to define a common vocabulary that will allow comparison of genome quality across different research groups, sequencing platforms, and assembly techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of optical constants of a biaxially anisotropic film by standard multiangle monochromatic ellipsometry

Possibilities of standard multiangle monochromatic ellipsometry in the determination of parameters of a uniform biaxially anisotropic layer are studied for the case of an arbitrary orientation of the two principal axes in the plane of incidence of the light beam and perpendicularity of the third axis to the plane of incidence. Using numerical simulation, it has been found that the measurement accuracy that is necessary in the determination of all the three principal components of the dielectric permittivity tensor ε and tilt angle of the axes using only angular dependences of ellipsometric parameters must be no worse than 0.0001°, which is far beyond the accuracy limits provided by present-day ellipsometers. If the tilt angle is known, standard multiangle monochromatic ellipsometry provides the determination of thickness and all three principal components of the dielectric permittivity tensor. This method allows one to determine the layer thickness and tensor component for the axis perpendicular to the plane of incidence, as well as the average value of components for the axes lying in the plane of incidence without involving the data about the tilt angle of the axes. This is demonstrated by an example of experimental data for biaxially anisotropic SiO{sub x} films obtained by oblique deposition of silicon monoxide SiO evaporated in vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of neutrons produced by muons in a standard rock

Characteristics of cosmogenic neutrons, such as the yield, production rate, and flux, were determined for a standard rock. The dependences of these quantities on the standard-rock depth and on the average muon energy were obtained. These properties and dependences make it possible to estimate easy the muon-induced neutron background in underground laboratories for various chemical compositions of rock.

58 GEOSCIENCES↗

Search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks using a matrix element method

A search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks is presented. Events with hadronic jets and one or two oppositely charged leptons are selected from a data sample corresponding to an integrated luminosity of 19.5fb -1 collected by the CMS experiment at the LHC in pp collisions at a centre-of-mass energy of 8TeV. In order to separate the signal from the larger tt¯ + jets background, this analysis uses a matrix element method that assigns a probability density value to each reconstructed event under signal or background hypotheses. The ratio between the two values is used in a maximum likelihood fit to extract the signal yield. The results are presented in terms of the measured signal strength modifier, μ, relative to the standard model prediction for a Higgs boson mass of 125GeV. The observed (expected) exclusion limit at a 95 % confidence level is μ < 4.2 (3.3), corresponding to a best fit value μ^ = 1.2 +1.6 -1.5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗