Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHIPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Structural dynamics modeling of spent nuclear fuel during hypothetical package drop events

The response of spent nuclear fuel (SNF) to hypothetical package drop events is of particular interest in the scope of spent fuel storage and transportation because of the mechanical shock encountered in such scenarios. Previous testing and modeling by the U.S. Department of Energy has demonstrated that the shock and vibration environment of normal shipping and handling conditions (excluding package drop events) is relatively benign and does not challenge the integrity of spent nuclear fuel. Cask drop events are worth considering because SNF packages are required to withstand free drops onto unyielding surfaces as part of their licensing basis. The acceleration experienced during drop events can be orders of magnitude higher, and thus more advanced models are needed to encompass potential nonlinear behavior of the fuel, such as spacer grid buckling and rod-to-rod impact. This work describes a number of finite element models developed to calculate the response of spent nuclear fuel to various hypothetical drop events that have been validated by package and fuel assembly drop tests conducted in the last decade. Sensitivity of the model response to factors such as package drop orientation, secondary impacts, and irradiated material properties as well as their potential impacts to fuel cladding integrity, was also investigated. Cask drops are not expected as a regular occurrence during SNF transportation, but this work helps raise the understanding of SNF mechanical loads to the point of consistency with the package design requirements.

Kadooka, Kevin↗

Review of High-Speed Fiber Optic Grating Sensors Systems

Fiber grating sensors can be used to support a wide variety of high speed measurement applications. This includes measurements of vibrations on bridges, traffic monitoring on freeways, ultrasonic detection to support non-destructive tests on metal plates and providing details of detonation events. This paper provides a brief overview of some of the techniques that have been used to support high speed measurements using fiber grating sensors over frequency ranges from 10s of kHz, to MHZ and finally toward frequencies approaching the GHz regime. Very early in the development of fiber grating sensor systems it was realized that a high speed fiber grating sensor system could be realized by placing an optical filter that might be a fiber grating in front of a detector so that spectral changes in the reflection from a fiber grating were amplitude modulated. In principal the only limitation on this type of system involved the speed of the output detector which with the development of high speed communication links moved from the regime of 10s of MHz toward 10s of GHz. The earliest deployed systems involved civil structures including measurements of the strain fields on composite utility poles and missile bodies during break tests, bridges and freeways. This was followed by a series of developments that included high speed fiber grating sensors to support nondestructive testing via ultrasonic wave detection, high speed machining and monitoring ship hulls. Each of these applications involved monitoring mechanical motion of structures and thus interest was in speeds up to a few 10s of MHz. Most recently there has been interest in using fiber grating to monitor the very high speed events such as detonations and this has led to utilization of fiber gratings that are consumed during an event that may require detection speeds of hundreds of MHz and in the future multiple GHz.

42 ENGINEERING↗

Testing the Dark Energy Camera on a Telescope Simulator

The Dark Energy Camera is a new prime-focus instrument to be delivered to the Blanco 4-meter telescope at the CerroTololo Inter-American Observatory (CTIO) in 2011. Construction is in-progress at this time at Fermilab. In order toverify that the camera meets technical specifications for the Dark Energy Survey and to reduce the time required tocommission the instrument while it is on the telescope, we are constructing a "Telescope Simulator" and performing fullsystem testing prior to shipping to CTIO. This presentation will describe the Telescope Simulator and how we use it toverify some of the technical specifications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prompt Neutron Multiplicity Measurements with Portable Detectors

Mobile detection of kilogram quantities of special nuclear materials (SNM) during maritime transportation is a challenging problem for the U.S. Department of Homeland Security. Counting neutrons emitted by the SNM and partitioning them from background neutrons of multiple origins is the most effective passive means of detecting the SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment is complex due to the presence of spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. This work studied the possibilities of building a prototype neutron detector using boron- 10 (10B) as the converter in a novel form factor called “straws” that would address the above problem by examining multiplicity distributions of neutrons originating from a fissioning source. Currently, commercially manufactured fission meters (FM) are available that separate cosmic neutrons from non-cosmic neutrons and quantitatively determine the strength of a fissioning source; however, these FMs use 3He, which is becoming increasingly difficult to procure; also the size and weight of a commercial FM is not conducive to manual neutron detection operations in a maritime environment. The current project may provide a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to the FM. The prototype detector provides a large-area, efficient, lightweight, more granular neutron responsive detection surface (to facilitate imaging) to ease the application of the new FMs. A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating of 10B as neutron converter (only 1 micron thick) inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2-mil thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90% Ar and 10% CO2). The tubes operate in proportional counter mode and attract mobile charged particles (alpha-particles) created in the nuclear interaction 10B(n, a)7Li. Several MCNPX calculations covering the substantial design parameter space of neutron multiplicity detectors have been performed and are presented. Our detector’s thermal neutron detection efficiency is compared to two Ortec commercial products, the Fission Meter and Detective-EX. Pulse height spectra originating from the charged particles created in the nuclear reaction 10B(n, a) 7Li* + 2.310 MeV (94%) – excited state (1) and 10B(n, a) 7Li + 2.792 MeV (6%) – ground state (2) are examined, and the response to incident gamma rays are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-543: Is It Feasible to Tighten the Criteria for IROC's Anthropomorphic Phantoms?

Purpose: To analyze results of IROC Houston QA center's (RPC) H and N and prostate IMRT phantoms to determine the effect that tightening criteria would have on the phantom pass rate. Methods: IROC Houston's anthropomorphic H and N and prostate phantoms are used to credential institution's to participate in NCI clinical trials that allow the use of IMRT. The phantoms are shipped to institutions where they are filled with water and undergo imaging, treatment planning, and irradiation as a patient would. Each phantom houses targets and organs at risk. They also hold film and TLD. Dosimeter results are compared to the institution's treatment plan using the criteria of 7% for PTV TLD doses and ≥85% pixels must pass 7%/4 mm global gamma analyses. Pass rates for the H and N and prostate phantoms were recalculated using the following tighter criteria options: 1) 5% TLD and 85% pixels 7%/4 gamma2) 5% TLD and 90% pixels 7%/4 gamma3) 5% TLD and 85% pixels 5%/4 gammaGamma analysis was repeated for the 30 most recent irradiations of each phantom to estimate results for criteria 3. Results: Pass rates using current criteria for the H and N and prostate phantoms are 84% and 85% respectively. Pass rates since gamma criteria were introduced in 2012 are 90% and 87%. Criteria 1 applied to all irradiations drops pass rates to 78% and 82%. Applying it to only irradiations with gamma results give 77% and 84%. Applying criteria 2 to only phantoms with gamma results drops pass rates to 80% and 74% and they fall to 83% and 67% respectively using criteria 3. Conclusion: Applying tighter criteria to phantom results has potential to increase quality in clinical trials. The results of the 30 most recent irradiations indicate that there may be room to tighten H and N phantom criteria in the future. Work supported by PHS grant CA10953 and CA081647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

SU-E-T-590: An Activation Study of Materials and Devices Present in a Proton Treatment Room

Purpose: The use of protons for radiation therapy is growing rapidly. One consequence of protons interacting with different media is activation. These nuclear reactions induced by the protons, scattered neutrons, and gamma rays, activate different materials encountered, particularly by the therapists. The purpose of this study was to examine the derived nuclides from the activation, and also the decay rate. Methods: The study was conducted in our proton therapy facility. Protons are derived from a synchrocyclotron and pass through field shipping systems, apertures, and range compensators to define the beam within the patient.Included materials of concerns measured; the patient support couch, sheet rock in the wall, solid plastics used for quality assurance and dosimetry, and the passive scattering system itself, which includes brass apertures, and Lucite or blue wax compensators. All devices were studied post irradiation using gamma spectroscopy to determine the nuclides, and a sodium iodine scintillation detector to measure decay, particularly when the dose rate fell to background levels. Results: We have also determined from the measurements we will maintain brass apertures for three months before sending them for scrap. Some of the radionuclides arrived from these measurements included Na-22 for the blue wax compensator, C1-34m for the sheetrock, and Sc-44 and Co-60 for the brass apertures. We found compensators made out of Lucite or wax decayed to background in 2 hours. The patient support couch decayed to background in approximately 40 minutes, and sheet rock decayed in 80 minutes. In terms of the aperture layers, the most proximal aperture slab had much higher activity than the distal slab. Also the proximal sides of the slabs were much more activate than the distal. Conclusion: We have given proper instruction to therapists performing quality assurance in terms of the handled plastics, and to handle apertures rapidly as possible.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-259: Development of a Primary Standard for LDR Brachytherapy

Purpose: The National Research Council initiated a program in 2012 to develop a primary standard to calibrate I-125 and Pd-103 sources used for LDR brachytherapy and disseminate this through calibration services to Canadian users. This will simplify procedures as Canadian cancer centres currently have to ship instruments to the US. Methods: The standard is based on a commercial version of the wide-angle free air chamber (WAFAC) pioneered by NIST. Significant enhancements were implemented to improve signal-to-noise and measurement reproducibility and eliminate electric field effects. Validation of this ionization chamber was then carried out in a low-energy X -ray beam (∼ 31 keV) where the dose rate had been previously established using the existing NRC primary standard free-air chamber. As a final component of this initial testing, measurements were made with a set of I-125 seeds (with air kerma strength traceable to NIST). Results: Excellent agreement of the two NRC free-air chambers was obtained within the combined standard uncertainty of 0.5 %. However, it was found that the WAFAC response is very sensitive to the beam geometry (distance from the source, diameter of the beam-defining aperture, etc) and Monte Carlo calculations, carried out to evaluate these geometry corrections, have confirmed the experimental results. The results for the seed measurements indicated a precision of better than 1 % is achievable for a reasonable acquisition time and the air kerma strength agreed with the manufacturer (NIST-traceable) value within 2 %. Conclusion: The prototype primary standard for LDR brachytherapy has met accuracy target of 3 % for the determination of air kerma strength. Work is ongoing to refine operation of the device and develop the calibration protocol for clinical users, with an anticipated launch of a calibration service in late 2015.

60 APPLIED LIFE SCIENCES↗

SU-F-T-304: Complex Multi-PTV Treatment Evaluation Using a Remotely Processed 3D Gel Dosimeter

Purpose: A new 3D gel dosimeter (ClearView™, Modus Medical Systems) was investigated for use as a QA tool for stereotactic radiosurgery (SRS) plans exhibiting high dose gradients and spatially separated treatment targets. The unique feature of this gel dosimeter is the remote processing service provided by Modus Medical Systems. Methods: The gel dosimeters were filled in either 10 cm diameter or 15 cm diameter clear plastic jars. The jars were then shipped in ice-cooled containers to our department for irradiation. Clinical SRS plans for treatment of multiple metastases and plans with simulated concave structures were applied to a CT scan of the gel dosimeter. The gel was irradiated in treatment position using modulated arcs and then returned in the cooled container for processing. The 3D gel dose was compared to the DICOM-RT dose from the treatment plan to assess dosimetric and geometric agreement. Results: There was no discernible difference between the planned and measured dose for dose gradients as high as 10%/mm, which was the highest gradient we evaluated. Geometric agreement for distant metastases separated by 6 cm was within 1.5 mm. Among three identically irradiated gels using a plan intended for nine metastases, the 3%/3mm gamma passing rate was 84.5% with a range of 14.7%, measured over the entire volume of the dosimeter. Regions of larger gamma values correlated with geometric offsets between the planned and measured data. Conclusion: The gel dosimeter exhibits the dosimetric and geometric characteristics necessary for 3D evaluation of treatment plan deliverability. The range of observed gamma passing rates suggests a high sensitivity to geometric registration. With proper management of geometric registration between planned and measured data, this service should enable a radiation oncology department to use 3D dosimetry in end-to-end testing or patient plan delivery QA without the expense of an in-house processing system.

60 APPLIED LIFE SCIENCES↗

Supramolecular Archimedean Cages Assembled with 72 Hydrogen Bonds

Self-assembly of multiple components into well-defined and predictable structures remains one of the foremost challenges in chemistry. Here, we report on the rational design of a supramolecular cage assembled from 20 ions of three distinct species through 72 hydrogen bonds. The cage is constructed from two kinds of hexagonal molecular tiles, a tris(guanidinium)nitrate cluster and a hexa(4-sulfonatophenyl)benzene, joined at their edges through complementary and metrically matched N-H {hor_ellipsis} O-S hydrogen bonds to form a truncated octahedron, one of the Archimedean polyhedra. The truncated octahedron, with an interior volume of 2200 cubic angstroms, serves as the composite building unit of a body-centered cubic zeolite-like framework, which exhibits an ability to encapsulate a wide range of differently charged species, including organic molecules, transition metal complexes, and 'ship-in-a-bottle' nanoclusters not observed otherwise.

08 HYDROGEN↗

Genomic surveillance reveals multiple introductions of SARS-CoV-2 into Northern California

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread globally, with >365,000 cases in California as of 17 July 2020. We investigated the genomic epidemiology of SARS-CoV-2 in Northern California from late January to mid-March 2020, using samples from 36 patients spanning nine counties and the Grand Princess cruise ship. Phylogenetic analyses revealed the cryptic introduction of at least seven different SARS-CoV-2 lineages into California, including epidemic WA1 strains associated with Washington state, with lack of a predominant lineage and limited transmission among communities. Lineages associated with outbreak clusters in two counties were defined by a single base substitution in the viral genome. These findings support contact tracing, social distancing, and travel restrictions to contain the spread of SARS-CoV-2 in California and other states.

59 BASIC BIOLOGICAL SCIENCES↗

The radiation characteristics of the transport packages with vitrified high-level waste

The calculation method of neutron yield in the (α, n) reaction for a homogeneous material of arbitrary composition is represented. It is shown that the use of the ORIGEN 2 code excluding the real elemental composition of vitrified high-level waste leads to significant underestimation of the neutron yield in the (α, n) reaction. For vitrified high-level waste and spent nuclear fuel from VVER, the neutron fluxes are analyzed. The thickness of the protective materials for a transfer cask and a shipping cask with vitrified highlevel waste are estimated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis of superheavy elements at the Dubna gas-filled recoil separator

A survey of experiments at the Dubna gas-filled recoil separator (Laboratory of Nuclear Reactions, JINR, Dubna) aimed at the detection and study of the “island of stability” of superheavy nuclei produced in complete fusion reactions of {sup 48}Ca ions and {sup 238}U–{sup 249}Cf target nuclei is given. The problems of synthesis of superheavy nuclei, methods for their identification, and investigation of their decay properties, including the results of recent experiments at other separators (SHIP, BGS, TASCA) and chemical setups, are discussed. The studied properties of the new nuclei, the isotopes of elements 112–118, as well as the properties of their decay products, indicate substantial growth of stability of the heaviest nuclei with increasing number of neutrons in the nucleus as the magic number of neutrons N = 184 is approached.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthesis of new superheavy elements using the Dubna Gas-Filled Separator: The complex of technologies

All the new isotopes of superheavy elements in the reactions with {sup 48}Ca ions and actinide targets, synthesized at the Flerov Laboratory of Nuclear Reactions (FLNR), have been obtained at the Dubna Gas-Filled Recoil Separator (DGFRS). Success was achieved with the use of several techniques, algorithms and approaches with record performance in their area. The most sophisticated of them are rare event detection technology, methods of measuring the effective equilibrium charges of heavy ions and nuclei in hydrogen at low pressure, modified approaches to evaluation of probabilistic characteristics of detected multichain events, beam-free test methods of detection equipment, and some other ones. The author analyzes the approaches that have led ultimately to a real breakthrough and an advance in experiments on the synthesis of superheavy elements. The development of detection systems also attracts the authors’ attention. Contributions from some facilities—such as SHIP, TASCA, and GARIS (RIKEN)—to synthesis experiments are partially noted. Under consideration are methods of automation of similar experiments, including the development of control and shielding systems for operation with highly active actinide targets. Some techniques for detecting α decay of heavy nuclei that came before the current experiments with electromagnetic separators are reviewed briefly. The methods, algorithms and hardware presented cover a more than twenty-year period of commissioning and application in long-term experiments at FLNR DGFRS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis of new transuranium isotopes in multinucleon transfer reactions using a velocity filter

Recently, we reported the observation of several new isotopes with proton numbers Z ≥ 92 in low-energy collisions of 48 Ca + 248 Cm . The peculiarity is that the nuclei were produced in multinucleon transfer reactions, a method which is presently discussed as a possible new way to enter so far unknown regions in the upper part of the Chart of Nuclides. For separation of the transfer products we used a velocity filter, the Separator for Heavy Ion Reaction Products SHIP at GSI. The resulting strong background suppression allowed us to detect nuclei with cross-sections down to the sub-nanobarn scale. Beside the new isotopes we identified about 100 further target-like transfer products and determined their cross-sections. In conclusion, the results together with previous measurements strongly indicate that multinucleon transfer reactions are a viable pathway to the production of new transuranium isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light $$Z^\prime $$ and Dirac fermion dark matter in the $$B-L$$ model

Abstract We consider a $$U(1)_{B-L}$$ U ( 1 ) B - L model with a $$Z^\prime $$ Z ′ portal Dirac fermion dark matter (DM) $$\chi $$ χ of low mass which couples very weakly to the $$B - L$$ B - L gauge boson $$Z^\prime $$ Z ′ . An arbitrary $$B-L$$ B - L charge $$Q\ne \pm 1, \pm 3$$ Q ≠ ± 1 , ± 3 of the DM $$\chi $$ χ ensures its stability. Motivated by the sensitivity reach of forthcoming “Lifetime Frontier” experiments, we focus on the $$Z^\prime $$ Z ′ mass, $$m_{Z^\prime }$$ m Z ′ , in the sub-GeV to few GeV range. To evaluate the DM relic abundance, we examine both the freeze-out and freeze-in DM scenarios. For the freeze-out scenario, we show that the observed DM abundance is reproduced near the $$Z^\prime $$ Z ′ resonance, $$m_\chi \simeq m_{Z^\prime }/2$$ m χ ≃ m Z ′ / 2 , where $$m_\chi $$ m χ is the DM mass. For the freeze-in scenario, we focus on $$m_\chi \ll m_{Z^\prime }$$ m χ ≪ m Z ′ . We show that for a fixed value of $$m_{Z^\prime }$$ m Z ′ , $$g_{BL}$$ g BL values roughly scale as 1/ Q to reproduce the observed DM abundance. For various Q values in the range between $$10^{-6}$$ 10 - 6 and $$10^2$$ 10 2 , we show that the gauge coupling values $$g_{BL}$$ g BL needed to reproduce the observed DM abundance lie in the search reach of future planned and/or proposed experiments such as FASER, Belle-II, LDMX, and SHiP. In the freeze-in case, the Q values to realize observable $$g_{BL}$$ g BL values are found to be much smaller than that in the freeze-out case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for the standard model Higgs boson at the CDF experiment

The understanding of the dynamics behind the breaking of the electroweak symmetry is one of the most important goals in the field of high energy physics. In the Standard Model (SM) Higgs mechanism plays a key role in the symmetry breaking, one manifestation of which is spin-0 Higgs boson. Thus the search for the Higgs boson is one of the flag-ship analyses at the Tevatron. Over the past few years the CDF experiment has made significant improvements in its sensitivity on the search for the SM Higgs boson. In this paper we summarize CDF's most recent results on the searches for the SM Higgs boson production at the Tevatron using data samples of integrated luminosities up to 3 fb{sup -1}. We also present the Tevatron's latest combined results on the SM Higgs boson search, and discuss the possibility that it could be found at the Tevatron in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neuromorphic data microscope

In 2016, Lewis Rhodes Labs, (LRL), shipped the first commercially viable Neuromorphic Processing Unit, (NPU), branded as a Neuromorphic Data Microscope (NDM). This product leverages architectural mechanisms derived from the sensory cortex of the human brain to efficiently implement pattern matching. LRL and Sandia National Labs have optimized this product for streaming analytics, and demonstrated a 1,000x power per operation reduction in an FPGA format. When reduced to an ASIC, the efficiency will improve to 1,000,000x. Additionally, the neuromorphic nature of the device gives it powerful computational attributes that are counterintuitive to those schooled in traditional von Neumann architectures. The Neuromorphic Data Microscope is the first of a broad class of brain-inspired, time domain processors that will profoundly alter the functionality and economics of data processing.

47 OTHER INSTRUMENTATION↗