Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

SU-G-JeP2-07: Fusion Optimization of Multi-Contrast MRI Scans for MR-Based Treatment Planning

Purpose: To develop an image fusion method using multiple contrast MRI scans for MR-based treatment planning. Methods: T1 weighted (T1-w), T2 weighted (T2-w) and diffusion weighted images (DWI) were acquired from liver cancer patient with breath-holding. Image fade correction and deformable image registration were performed using VelocityAI (Varian Medical Systems, CA). Registered images were normalized to mean voxel intensity for each image dataset. Contrast to noise ratio (CNR) between tumor and liver was quantified. Tumor area was defined as the GTV contoured by physicians. Normal liver area with equivalent dimension was used as background. Noise was defined by the standard deviation of voxel intensities in the same liver area. Linear weightings were applied to T1-w, T2-w and DWI images to generate composite image and CNR was calculated for each composite image. Optimization process were performed to achieve different clinical goals. Results: With a goal of maximizing tumor contrast, the composite image achieved a 7–12 fold increase in tumor CNR (142.8 vs. −2.3, 11.4 and 20.6 for T1-w, T2-w and DWI only, respectively), while anatomical details were largely invisible. With a weighting combination of 100%, −10% and −10%, respectively, tumor contrast was enhanced from −2.3 to −5.4, while the anatomical details were clear. With a weighting combination of 25%, 20% and 55%, balanced tumor contrast and anatomy was achieved. Conclusion: We have investigated the feasibility of performing image fusion optimization on multiple contrast MRI images. This mechanism could help utilize multiple contrast MRI scans to potentially facilitate future MR-based treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-08: Image Reconstruction for Scanning Imaging System Based On Shape-Modulated Point Spreading Function

Purpose: Deconvolution is a widely used tool in the field of image reconstruction algorithm when the linear imaging system has been blurred by the imperfect system transfer function. However, due to the nature of Gaussian-liked distribution for point spread function (PSF), the components with coherent high frequency in the image are hard to restored in most of the previous scanning imaging system, even the relatively accurate PSF is acquired. We propose a novel method for deconvolution of images which are obtained by using shape-modulated PSF. Methods: We use two different types of PSF - Gaussian shape and donut shape - to convolute the original image in order to simulate the process of scanning imaging. By employing deconvolution of the two images with corresponding given priors, the image quality of the deblurred images are compared. Then we find the critical size of the donut shape compared with the Gaussian shape which has similar deconvolution results. Through calculation of tightened focusing process using radially polarized beam, such size of donut is achievable under same conditions. Results: The effects of different relative size of donut and Gaussian shapes are investigated. When the full width at half maximum (FWHM) ratio of donut and Gaussian shape is set about 1.83, similar resolution results are obtained through our deconvolution method. Decreasing the size of donut will favor the deconvolution method. A mask with both amplitude and phase modulation is used to create a donut-shaped PSF compared with the non-modulated Gaussian PSF. Donut with size smaller than our critical value is obtained. Conclusion: The utility of donutshaped PSF are proved useful and achievable in the imaging and deconvolution processing, which is expected to have potential practical applications in high resolution imaging for biological samples.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-09: Impact of Interfractional Motion On Hypofractionated Pencil Beam Scanning Proton Therapy for Prostate Cancer

Purpose: To investigate the impact of anatomy/setup variations on standard vs. hypofractionated anterolateral pencil beam scanning (PBS) proton therapy for prostate cancer. Methods: Six prostate cancer patients treated with double-scattering proton therapy, who underwent weekly verification CT scans were selected. Implanted fiducials were used for localization, and endorectal balloons for immobilization. New PBS plans using combination of lateral and anterior-oblique (AO) (±35 deg) beams were created. AO beams were added to spare the femoral heads during hypofractionation. Lateral beams delivered 50.4 Gy(RBE) to prostate plus 5-15mm of seminal vesicles and AO beams 28.8 Gy(RBE) to prostate, in 44 fractions. PTV was laterally expanded by 2.5% to account for range uncertainty. No range margins were applied for AO beams, assuming delivery with in-vivo range verification. Field-specific apertures with 1.2cm margin were used. Spot size was ∼9.5mm sigma for 172MeV @isocenter in air. Plans were optimized as single-field-uniform-dose with ∼5% maximum non-uniformity. The planned dose was recomputed on each weekly CT after aligning the fiducials with the simulation CT, scaled and accumulated via deformable image registration. Hypofractionated treatments with 12 and 5 fractions were considered. Equivalent doses were calculated for prostate (α/β= 1.5Gy), bladder and rectum (α/β= 3Gy). Results: The biological equivalent prostate dose was 86.2 and 92.9 Gyeq for the hypofractionation scenarios at 4.32 and 7.35 Gy/fx, respectively. The equivalent prostate D98 was degraded by on average 2.7 Gyeq for standard, and 3.1 and 4.0 Gyeq for the hypofractionated plans after accumulation. Differences between accumulated and planned Dmean/D2/EUD were generally reduced when reducing the number of fractions for bladder and rectum. The average Dmean/D2/EUD differences over all patients and organs-at-risk were 0.74/4.0/9.23, 0.49/3.64/5.51, 0.37/3.21/3.49 Gyeq for 44, 12 and 5 fractions. Conclusion: Hypofractionation makes proton therapy of prostate more susceptible to interfractional motion-induced target dose degradation compared to the standard fractionation.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-12: Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance

Purpose: With the growing adoption of proton beam therapy there is an increasing need for effective and user-friendly tools for performing quality assurance (QA) measurements. The speed and versatility of spot-scanning proton beam (PB) therapy systems present unique challenges for traditional QA tools. To address these challenges a proof-of-concept system was developed to visualize, in real-time, the delivery of individual spots from a spot-scanning PB in order to perform QA measurements. Methods: The PB is directed toward a custom phantom with planar faces coated with a radioluminescent phosphor (Gd2O2s:Tb). As the proton beam passes through the phantom visible light is emitted from the coating and collected by a nearby CMOS camera. The images are processed to determine the locations at which the beam impinges on each face of the phantom. By so doing, the location of each beam can be determined relative to the phantom. The cameras are also used to capture images of the laser alignment system. The phantom contains x-ray fiducials so that it can be easily located with kV imagers. Using this data several quality assurance parameters can be evaluated. Results: The proof-of-concept system was able to visualize discrete PB spots with energies ranging from 70 MeV to 220 MeV. Images were obtained with integration times ranging from 20 to 0.019 milliseconds. If not limited by data transmission, this would correspond to a frame rate of 52,000 fps. Such frame rates enabled visualization of individual spots in real time. Spot locations were found to be highly correlated (R{sup 2}=0.99) with the nozzle-mounted spot position monitor indicating excellent spot positioning accuracy Conclusion: The system was shown to be capable of imaging individual spots for all clinical beam energies. Future development will focus on extending the image processing software to provide automated results for a variety of QA tests.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-02: Beam Angle Optimization Incorporating Anatomical Heterogeneities for Pencil Beam Scanning Charged-Particle Therapy

Purpose: In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. Sensitivity of a PBS plan to lateral tissue heterogeneity can be reduced by selecting suitable beam angles. The purpose of this study is to establish a fast and accurate method of beam angle selection for PBS. Methods: The lateral tissue heterogeneity surrounding the path of respective pencil beams at a given angle was quantified with the heterogeneity number using effective density data of patients. To shorten the computation time, one dimensional dose calculation and optimization were conducted along the central axis of pencil beams originating from the scanning magnets. Calculation was performed for all fields with possible gantry and couch angles. The angles leading the minimum mean heterogeneity number was selected as the optimal beam angle. Three head and neck (H&N) cancer patients were used to evaluate our method. Dose distributions and their robustness to range and set up errors were evaluated for all tested angles, and their relation to their heterogeneity numbers were investigated. Results: Variety of heterogeneity number was clearly shown due to air cavities and bony structures in the patients. The mean value of heterogeneity number in all possible fields varied between 1.2 and 10.6 mm. By selecting a field with a lower mean value of heterogeneity number, target dose coverage and robustness of the fields were improved. Conclusion: We developed a computational method to determine a beam angle that leads good target coverage and robustness to setup errors. The developed stand-alone computation program is simple, fast, accurate and applicable for beam angle selection in PBS therapy.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-12: Spatial Mapping of Scanned Proton Biologic Effect Using the High-Throughput Technique, Continued

Purpose: To investigate the biologic effects of scanned protons by evenly sampling dose-averaged LET (LETd) values. Methods: Our previous high-throughput clonogenic study demonstrated a distinct relationship between RBE and LETd. However, our initial experimental design resulted in over-sampling the low LETd values in the plateau region of the Bragg curve while under-sampling in the region proximal to the Bragg peak as well as the high LETd values in the distal edge of the Bragg curve. To further examine the relationship between RBE and LETd, we refined the experimental design to more evenly sample proton LETd values from 1 to 20 keV/µm by optimizing the thicknesses of the irradiation jig steps. We used the clonogenic survival as the biological endpoint for the H460 lung cancer cell line cultured in 96-well plates (12 columns by 8 rows). In the irradiation, the 8 wells in each column received a uniform dose-LETd pair. The dose-LETd pairs of the 12 different columns were sampled along the Bragg curve of 81.4 MeV scanned protons. Five peak dose levels from 1.5 Gy to 7.5 Gy were delivered with an increment of 1.5 Gy in the preliminary test. Two 96-well plates were irradiated simultaneously to decrease the statistical uncertainties. Results: In the proximal region, for LETd = 5 keV/µm and 8 keV/µm, we did not observe any distinct differential biologic effects between the survival curves. At the Bragg peak (LETd = 9.5 keV/µm) and in the distal edge, irradiation with increasing LET values resulted in decreasing cell survival. Conclusion: The survival curves from the new experimental design support our previous findings that below 10 keV/µm, the LET effect in cell kill is obscured, but above 10 keV/µm, the biologic effects increase with LETd. Funding Support: U19 CA021239-35 and R21 CA187484-01.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 07: A mould room in a box – 3D scanning and printing technology in the radiotherapy clinic

Purpose: We describe the process by which our centre is currently implementing 3D printing and scanning technology for treatment accessory fabrication. This technology can increase efficiency and accuracy of accessory design, production and placement during daily use. Methods: A low-cost 3D printer and 3D optical scanner have been purchased and are being commissioned for clinical use. Commissioning includes assessing: the accuracy of the 3D scanner through comparison with high resolution CT images; the dosimetric characteristics of polylactic acid (PLA) for electron beams; the clinical utility of the technology, and; methods for quality assurance. Results: The agreement between meshes generated using the 3D scanner and CT data was within 2 millimeters for an anthropomorphic head phantom. In terms of electron beam attenuation, 1 centimetre of printed PLA was found equivalent to 1.17 cm of water. In proof-of-concept tests, several types of treatment accessories have been prototyped to date that will benefit from this technology. These include electron and photon bolus for areas with complex surface contours including the ear for electron treatments, the extremities for photon treatments and lead shielding for orthovoltage treatments. Imaging with CT and x-ray showed minimal defects, which will have no significant clinical impact. Geometric fidelity and fit to volunteers and patients was found to be excellent. Conclusions: 3D Printing and scanning can increase efficiency in the clinic for treatments requiring custom accessories. Customized boluses and shielding had excellent fit and reduced uncertainty in positioning.

60 APPLIED LIFE SCIENCES↗

X-ray diffraction analysis and scanning micro-Raman spectroscopy of structural irregularities and strains deep inside the multilayered InGaN/GaN heterostructure

High-resolution X-ray diffraction analysis and scanning confocal Raman spectroscopy are used to study the spatial distribution of strains in the In{sub x}Ga{sub 1-x}N/GaN layers and structural quality of these layers in a multilayered light-emitting diode structure produced by metal-organic chemical vapor deposition onto (0001)-oriented sapphire substrates. It is shown that elastic strains almost completely relax at the heterointerface between the thick GaN buffer layer and In{sub x}Ga{sub 1-x}N/GaN buffer superlattice. It is established that the GaN layers in the superlattice are in a stretched state, whereas the alloy layers are in a compressed state. In magnitude, the stretching strains in the GaN layers are lower than the compressive strains in the InGaN layers. It is shown that, as compared to the buffer layers, the layers of the superlattice contain a smaller number of dislocations and the distribution of dislocations is more randomly disordered. In micro-Raman studies on scanning through the thickness of the multilayered structure, direct evidence is obtained for the asymmetric gradient distributions of strains and crystal imperfections of the epitaxial nitride layers along the direction of growth. It is shown that the emission intensity of the In{sub x}Ga{sub 1-x}N quantum well is considerably (more than 30 times) higher than the emission intensity of the GaN barrier layers, suggesting the high efficiency of trapping of charge carriers by the quantum well.

36 MATERIALS SCIENCE↗

Near-Optimal and Practical Algorithms for Graph Scan Statistics with Connectivity Constraints

One fundamental task in network analysis is detecting “hotspots” or “anomalies” in the network; that is, detecting subgraphs where there is significantly more activity than one would expect given historical data or some baseline process. Scan statistics is one popular approach used for anomalous subgraph detection. This methodology involves maximizing a score function over all connected subgraphs, which is a challenging computational problem. A number of heuristics have been proposed for these problems, but they do not provide any quality guarantees. Here, we propose a framework for designing algorithms for optimizing a large class of scan statistics for networks, subject to connectivity constraints. Our algorithms run in time that scales linearly on the size of the graph and depends on a parameter we call the “effective solution size,” while providing rigorous approximation guarantees. In contrast, most prior methods have super-linear running times in terms of graph size. Extensive empirical evidence demonstrates the effectiveness and efficiency of our proposed algorithms in comparison with state-of-the-art methods. Our approach improves on the performance relative to all prior methods, giving up to over 25% increase in the score. Further, our algorithms scale to networks with up to a million nodes, which is 1–2 orders of magnitude larger than all prior applications.

97 MATHEMATICS AND COMPUTING↗

Microstructural Study of Hydration of C 3 S in the Presence of Calcium Nitrate Using Scanning Transmission X-Ray Microscopy (STXM)

Calcium nitrate (CN) is used widely as an effectively inorganic setting accelerator and antifreeze admixture in concrete structures. In this paper, the multiscale investigation of CN on the hydration of C 3 S was studied by scanning transmission X-ray microscopy (STXM) combined with near-edge X-ray absorption fine structure (NEXAFS), 29 Si MAS NMR, calorimetry, scanning electron microscope, and N 2 absorption. It was concluded that the calcium silicate hydrate (C-S-H) surrounds the unhydrated C 3 S at 1-day hydrated C 3 S in the presence of calcium nitrate, while portlandite is partly in transformation and is formed partly. Based on Ca L 3 , 2 -edge NEXAFS spectra for 1-day hydrated C 3 S particle, calcium nitrate does not change the structure of the asymmetrically 7-fold coordination of calcium in the C-S-H. Calcium nitrate can accelerate the hydration of C 3 S to some extent and polymerization of the silicate chains within C-S-H considerably at early age, resulting in the increasing specific surface area.

Li, Qinfei↗

PRESSURE-FILM OPEN SOURCE SCANNING AND MAPPING

SF-22-099 Pressure-film Open Source Scanning and Mapping (POSSM) is software that analyses images of pressure-film (scans or photographs). POSSM collects data from that analysis in order to produce a number of visual aides, including pressure maps, histograms, and 3d surface plots. POSSM is designed to be able to analyze an entire folder full of images, exporting numeric data as .csv files and visual graphics as .png files.

Grider, Patrick↗

A Variational Method for Analyzing Vortex Flows in Radar-Scanned Tornadic Mesocyclones. Part III: Sensitivities to Vortex Center Location Errors

Abstract When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an important issue concerning the sensitivities of analyzed vortex flow (VF) fields by the VF-Var (formulated in Part I of this paper series and tested in Part II) to vortex center location errors, denoted by Δ x c . Numerical experiments are performed to address this issue with the following findings: The increase of |Δ x c | from zero to a half of vortex core radius causes large analysis error increases in the vortex core but the increased analysis errors decrease rapidly away from the vortex core especially for dual-Doppler analyses. The increased horizontal-velocity errors in the vortex core are mainly in the Δ x c -normal component, because this component varies much more rapidly than the other component along the Δ x c direction in the vortex core. The vertical variations of Δ x c distort the vertical correlation structure of Δ x c -dislocated VF-dependent background error covariance, which can increase the analysis errors in the vortex core. The dual-Doppler analyses have adequate accuracies outside the vortex core even when |Δ x c | increases to a half of vortex core radius, while single-Doppler analyses can also have adequate accuracies outside the vortex core mainly for the single-Doppler-observed velocity component. The sensitivities to Δ x c are largely unaffected by the vortex slanting. The above findings are important and useful for assessing the accuracies of analyzed VFs for real radar-observed tornadic mesocyclones. Significance Statement When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an issue concerning the sensitivity of analyzed vortex flow (VF) by the VF-Var (formulated in Part I of this paper series and tested with simulated radar observations in Part II) to vortex center location error. This issue and its required investigations are very important for the VF-Var to be applied to real radar-observed tornadic mesocyclones, especially in an operational setting with the WSR-88Ds. Numerical experiments are performed to address this issue. The findings from these experiments are important and useful for assessing the accuracies of VF-Var analyzed VF fields for real radar-observed tornadic mesocyclones.

Xu, Qin↗

Temperature Inversions below 1 km from a V-Band Scanning Radiometer at the North Slope of Alaska

A single-channel (56.7 GHz) scanning radiometer was deployed in August 2022 at the Atmospheric Radiation Measurement (ARM) North Slope of Alaska site near Utqiaġvik. The radiometer is designed to provide temperature profiles between 0 and 1 km every 5 min. Averaging kernels show that this single-channel radiometer, taking observations at 10 discrete elevation angles, yields approximately the same information as a seven-channel V-band radiometer scanning three elevation angles. The instrument is able to reproduce the occurrence of temperature inversions between the surface and 1 km and their strength showing a correlation of 0.85, bias of −0.6 K, and slope of 1.04 with respect to radiosondes. Uncertainty in the inversion base height varies from 50 m near the surface to ∼300 m above 0.4 km when compared with radiosondes. Conversely, the inversion top height is overestimated and has higher uncertainty due to the degrading effects of the averaging kernels on the vertical resolution of the retrievals. Thanks to the high temporal resolution of the retrievals, the diurnal cycle of boundary layer temperature was evaluated showing that the radiometer can capture some aspects of the boundary layer thermal structure. The present analysis provides an overview of the capabilities of this simple observing configuration for selected applications.

Atmospheric profilers↗

Method to measure orientation of discontinuous fiber embedded in the polymer matrix from computerized tomography scan data

Usage of discontinuous glass fibers in injection and compression molded resin components is rapidly increasing to improve their mechanical properties. Since added fiber contributes to more strength along the fiber direction compared to transverse direction, the mechanical properties of such components strongly depend on the fiber orientation. Thus it is important to estimate the fiber orientation distribution in such materials. Here, we are presenting recently developed method to estimate fiber orientation from 3D image of fibers generated using micro CT scan. Typically the 3D images from CT scan are very large and it becomes difficult to separate each fiber and extract end point information. In this paper a novel method to address this challenge is presented. The micro-CT images were broken into finite volume, reducing data size, and then each fiber was reduced to its own center line, further reducing the data size, using Mimics Innovation Suite (Materialise NV). These 3D centerlines were then used to quantify the 2nd order orientation tensor. Our results from the proposed method are compared with the measurements using well established industry standard approach called method of ellipses for validation. The key challenges in estimating the fiber orientation are identified and future improvements are proposed.

36 MATERIALS SCIENCE↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

Long-range time-of-flight scanning sensor based on high-speed time-correlated single-photon counting

We describe a scanning time-of-flight system which uses the time-correlated single-photon counting technique to produce three-dimensional depth images of distant, noncooperative surfaces when these targets are illuminated by a kHz to MHz repetition rate pulsed laser source. The data for the scene are acquired using a scanning optical system and an individual single-photon detector. Depth images have been successfully acquired with centimeter xyz resolution, in daylight conditions, for low-signature targets in field trials at distances of up to 325 m using an output illumination with an average optical power of less than 50 {mu}W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples

We investigated a high-precision optical method for measuring the thickness of biological samples regardless of their transparency. The method is based on the precise measurement of optical path length difference of the end surfaces of objects, using a dual-arm axial-scanning low-coherence interferometer. This removes any consideration of the shape, thickness, or transparency of testing objects when performing the measurement. Scanning the reference simplifies the measurement setup, resulting in unambiguous measurement. Using a 1310 nm wavelength superluminescent diode, with a 65 nm bandwidth, the measurement accuracy was as high as 11.6 {mu}m. We tested the method by measuring the thickness of both transparent samples and nontransparent soft biological tissues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning holographic optical tweezers

The aim of this Letter is to introduce a new optical tweezers approach, called scanning holographic optical tweezers (SHOT), which drastically increases the working area (WA) of the holographic-optical tweezers (HOT) approach, while maintaining tightly focused laser traps. A 12-fold increase in the WA is demonstrated. The SHOT approach achieves its utility by combining the large WA of the scanning optical tweezers (SOT) approach with the flexibility of the HOT approach for simultaneously moving differently structured optical traps in and out of the focal plane. This Letter also demonstrates a new heuristic control algorithm for combining the functionality of the SOT and HOT approaches to efficiently allocate the available laser power among a large number of traps. The proposed approach shows promise for substantially increasing the number of particles that can be handled simultaneously, which would enable optical tweezers additive fabrication technologies to rapidly assemble microgranular materials and structures in reasonable build times.

42 ENGINEERING↗