Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

High-Q suspended optical resonators in 3C silicon carbide obtained by thermal annealing

We fabricate suspended single-mode optical waveguides and ring resonators in 3C silicon carbide (SiC) that operate at telecommunication wavelength, and leverage post-fabrication thermal annealing to minimize optical propagation losses. Annealed optical resonators yield quality factors of over 41,000, which corresponds to a propagation loss of 7 dB/cm, and is a significant improvement over the 24 dB/cm in the case of the non-annealed chip. This improvement is attributed to the enhancement of SiC crystallinity and a significant reduction of waveguide surface roughness, from 2.4 nm to below 1.7 nm. The latter is attributed to surface layer oxide growth during the annealing step. We confirm that the thermo-optic coefficient, an important parameter governing high-power and temperature-dependent performance of SiC, does not vary with annealing and is comparable to that of bulk SiC. Our annealing-based approach, which is especially suitable for suspended structures, offers a straightforward way to realize high-performance 3C-SiC integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mitigating photorefractive effect in thin-film lithium niobate microring resonators

Thin-film lithium niobate is an attractive integrated photonics platform due to its low optical loss and favorable optical nonlinear and electro-optic properties. However, in applications such as second harmonic generation, frequency comb generation, and microwave-to-optics conversion, the device performance is strongly impeded by the photorefractive effect inherent in thin-film lithium niobate. In this paper, we show that the dielectric cladding on a lithium niobate microring resonator has a significant influence on the photorefractive effect. By removing the dielectric cladding layer, the photorefractive effect in lithium niobate ring resonators can be effectively mitigated. Our work presents a reliable approach to control the photorefractive effect on thin-film lithium niobate and will further advance the performance of integrated classical and quantum photonic devices based on thin-film lithium niobate.

42 ENGINEERING↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

O 2 based resonantly ionized photoemission thermometry analysis of supersonic flows

Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.

42 ENGINEERING↗

Non-resonant Bragg scattering four-wave mixing at near-visible wavelengths in low-confinement silicon nitride waveguides

Quantum state coherent frequency conversion processes—such as Bragg-scattering four-wave mixing (BSFWM)—hold promise as a flexible technique for networking heterogeneous and distant quantum systems. In this Letter, we demonstrate BSFWM within an extended (1.2-m) low-confinement silicon nitride waveguide and show that this system has the potential for near-unity frequency conversion in visible and near-visible wavelength ranges. Using sensitive classical heterodyne laser spectroscopy at low optical powers, we characterize the Kerr coefficient (∼1.55 W −1 m −1 ) and linear propagation loss (∼0.0175 dB/cm) of this non-resonant waveguide system, revealing a record-high nonlinear figure of merit (NFM = γ / α ≈ 3.85 W −1 ) for BSFWM of near-visible light in non-resonant silicon nitride waveguides. We predict how, at high yet achievable on-chip optical powers, this NFM would yield a comparatively large frequency conversion efficiency, opening the door to near-unity flexible frequency conversion without cavity enhancement and resulting bandwidth constraints.

Jaber, Nicholas (ORCID:000900070106809X)↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Distinguishing under- and over-coupled resonances without prior knowledge

We show that it is unreliable to determine the coupling condition of optical resonances by analyzing the extinction ratio change with wavelengths. We propose and demonstrate the unambiguous discrimination between under- and over-coupled resonances using binary phase modulation in power transmission measurement.

Cui, Chaohan (ORCID:0000000345178980)↗

Low-lying baryon resonances from lattice QCD

Recent results studying the masses and widths of low-lying baryon resonances in lattice QCD are presented. The S-wave Nπ scattering lengths for both total isospins I = 1/2 and I = 3/2 are inferred from the finite-volume spectrum below the inelastic threshold together with the I = 3/2 P-wave containing the Δ(1232) resonance. A lattice QCD computation employing a combined basis of three-quark and meson-baryon interpolating operators with definite momentum to determine the coupled channel $Σπ-N\bar{K}$ scattering amplitude in the Λ(1405) region is also presented. Our results support the picture of a two-pole structure suggested by theoretical approaches based on SU(3) chiral symmetry and unitarity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonant Frequency Derived from the Rayleigh-Wave Dispersion Image: The High-Impedance Boundary Problem

In this work, we present a simple and automated approach to estimate primary site-response resonance, layer thickness, and shear-wave velocity directly from a dispersion image for a layer over half-space problem. We demonstrate this for high-impedance boundary conditions that lie in the upper tens of meters. Our approach eliminates the need for time-consuming dispersion curve picking and 1D shear-wave velocity inversion for large data volumes that can capture velocity structure in profile. We highlight important relationships between dispersion characteristics and resonance parameters through synthetic modeling and field data acquired over Atlantic Coastal Plain sediments. In this environment, shallow soil conditions are critical to accurately estimate earthquake site response. We suggest that this image processing approach can be applied to a range of high-impedance conditions, at a range of scales, or can provide model constraints for more complex velocity structures.

58 GEOSCIENCES↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗

T-BMT Spin Resonance Tracker Code for He3 with Six Snakes

Polarization lifetime for He3 using two and six snakes are studied using the T-BMT Spin Resonance Tracker code. This code integrates a reduced spinor form of the T-BMT equation including only several spin resonances and the kinematics of synchrotron motion. It was previously benchmarked against RHIC polarization lifetime under the two snake system *. * Phys. Rev.Accel. Beams 22 (2019) 9, 091001

Ranjbar, V. H.↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

Thomas Jefferson National Accelerator Facility (Jeffer- son Lab) currently studies the feasibility of upgrading its energy to 22 GeV. It considers addition of six more linac passes. The highest energy passes will share two new arcs designed using the Fixed-Field Alternating Gradient (FFA) technology. The FFA arcs are built using permanent combined-function magnets. They will be connected to the linacs through transition sections that will match the optics of all six passes to the linacs. With the high number of con- straints and the limited space available, we are investigating a parametric resonance technique to match the optics quasi- independently at each energy. A resonance is excited at each individual energy to selectively control its optics. The reso- nant dipole and quadrupole kick harmonics are imposed for all energies simultaneously using Panofsky corrector mag- nets placed throughout the FFA arcs. This paper presents the current progress on that transition section design

Deitrick, K.↗

Geometry Optimization for a Quadrupole Resonator at Jefferson Lab

The quadrupole resonator (QPR) is a sample characterization tool to measure the RF properties of superconducting materials using the calorime-try method at different temperatures, magnetic fields, and frequencies. Such resonators are cur-rently operating at CERN and HZB but suffer from Lorentz force detuning and modes overlap-ping, resulting in higher uncertainties in surface resistance measurement. Using the two CERN's QPR model iterations, the geometry was opti-mized via electromagnetic and mechanical simu-lations to eliminate these issues. The new QPR version was modelled for an increasing range of magnetic fields. The magnetic field is concentrat-ed at the center of the sample to reduce the un-certainty in surface resistance measurements sig-nificantly. This paper discusses the QPR geome-try optimization for the new version of QPR, which is now progressing toward fabrication.

Bira, S.↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗