Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Environments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Design and Testing of the Endcap Concentrator ASICs for the CMS High-Granularity Calorimeter Upgrade

A major upgrade of the High-Granularity Calorimeter (HGCAL) in the CMS detector is planned for Long-Shutdown 3 (LS3), currently expected to start in 2026. This upgrade will contain over 6 million channels and the electronics will be required to be low power and to withstand a radiation environment with a High-Energy Hadron flux of 3x10**6 particles per square centimeter per second. The solution to this significant challenge is the two Endcap Concentrator (ECON) ASICs, ECON-T and ECON-D, working in tandem with the HGCROC front-end ASIC. The two ECON ASICs provide critical on-detector data reduction for both the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs are fabricated in 65nm CMOS. They are rad-tolerant to 600 Mrad with low power consumption (<2.5 mW/channel). This presentation will be a comprehensive description of each ECON design, including the infrastructure that they share as well as the elements that make each unique. The presentation will also include functionality and radiation tests for both ASICs, and the first high statistics characterization results from the full production of 75k ECON-D and ECON-T ASICs.

Hoff, James R. [Fermilab] (ORCID:0000000163514592)↗

Simulation of neutron radiation damage in silicon semiconductor devices.

A code, Charon, is described which simulates the effects that neutron damage has on silicon semiconductor devices. The code uses a stabilized, finite-element discretization of the semiconductor drift-diffusion equations. The mathematical model used to simulate semiconductor devices in both normal and radiation environments will be described. Modeling of defect complexes is accomplished by adding an additional drift-diffusion equation for each of the defect species. Additionally, details are given describing how Charon can efficiently solve very large problems using modern parallel computers. Comparison between Charon and experiment will be given, as well as comparison with results from commercially-available TCAD codes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Tolerant Electronics and Digital Processing for the Phase-I Trigger Readout Upgrade of the ATLAS Liquid Argon Calorimeters

The high luminosities of L > 10{sup 34} cm{sup -2}s{sup -1} at the Large Hadron Collider (LHC) at CERN produce an intense radiation environment that the detectors and their electronics must withstand. The ATLAS detector is a multi-purpose apparatus constructed to explore the new particle physics regime opened by the LHC. Of the many decay particles observed by the ATLAS detector, the energy of the created electrons and photons is measured by a sampling calorimeter technique that uses Liquid Argon (LAr) as its active medium. The front end (FE) electronic readout of the ATLAS LAr calorimeter located on the detector itself consists of a combined analog and digital processing system. In order to exploit the higher luminosity while keeping the same trigger bandwidth of 100 kHz, higher transverse granularity, higher resolution and longitudinal shower shape information will be provided from the LAr calorimeter to the Level-l trigger processors. New trigger readout electronics have been designed for this purpose, which will withstand the radiation dose levels expected for an integrated luminosity of 3000 fb{sup -1} during the high luminosity LHC (HL-LHC), which is well above the original LHC design qualifications. (authors)

43 PARTICLE ACCELERATORS↗

Overview of CMOS Sensors for Future Tracking Detectors

Depleted Complementary Metal-Oxide-Semiconductor (CMOS) sensors are emerging as one of the main candidate technologies for future tracking detectors in high luminosity colliders. Their capability of integrating the sensing diode into the CMOS wafer hosting the front-end electronics allows for reduced noise and higher signal sensitivity, due to the direct collection of the sensor signal by the readout electronics. They are suitable for high radiation environments due to the possibility of applying high depletion voltage and the availability of relatively high resistivity substrates. The use of a CMOS commercial fabrication process leads to their cost reduction and allows faster construction of large area detectors. In this contribution, a general perspective of the state of the art of CMOS detectors for High Energy Physics experiments is given. The main developments carried out with regard to these devices in the framework of the CERN RD50 collaboration are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of IR radiation simulator for spacecraft thermal testing

The aim was to simulate, in a ground test, the solar radiation environment to which the Ofeq satellite would be exposed in orbit. The solar simulator usually used is very expensive, as are its operation and maintenance, therefore an infrared (IR) simulator was used; its development involved the creation of uniform IR fluxes onto the irregular geometry of a spacecraft. The tests were carried out on a thermal model of the satellite and the model was verified in a solar simulator test at a European space center. Heat flux mapping software was developed to plan the positioning of the heating elements which generated the IR fluxes and a system was built for heat flux and temperature monitoring and control. A special heat flux sensor was developed to measure the energy absorbed by the satellite surfaces; its calibration had to be independent of wavelength, so that the measurements obtained at IR wavelengths would be equivalent to the actual solar radiation effects. The results of the verification experiment are presented; their conformity with predicted values indicates that the technique developed is a suitable tool for satellite design verification.

Shimrony, Yoram↗

Space Radiation and Central Nervous System Impacts: NASA Standards and Evidence

It is well understood that large radiation localized doses to the brain cause clinically significant impacts to the central nervous system in human populations. However, the effects in adults exposed to lower doses remain unclear due to lack of data in relevant human cohorts. The impact of exposure to high-energy particles is even less understood. NASA’s Human Research Program relies heavily on model systems to characterize the impacts of the space radiation environment on the human brain and how potential changes may effect mission success and long term health and well-being. Animal, cellular, and molecular experiments implicate multiple – and possibly related – mechanisms that mediate impacts to the central nervous system in model systems including, but not limited to inflammation, immune responses, oxidative stress, metabolism, myelination, molecule transport, electrophysiology, and a variety of “omic” changes. While animal studies demonstrate potential changes across a number of cognitive and behavioral domains the direct applicability to the astronaut population remains unclear. Furthermore data access experiments and model systems can be inconsistent and dependent on multiple experimental variables indicating a clear need for robust validation. To minimize potential impacts to astronauts NASA limits dose to the CNS based on a combination of terrestrial epidemiology informed by experimental evidence in model systems. To date no recommendations have been provided by the National Committee on Radiation Protection and Measurements. This presentation will provide an overview of NASA’s current dose limits for CNS exposure to space radiation as well as highlights of the current state of evidence and ongoing research.

S Robin Elgart↗

New approaches to Bayesian uncertainty quantification for Nuclear Science (Final Technical Report)

Inverse problems play a central role in experimentation and theory/data comparisons for many areas of modern Nuclear Physics (NP) and High-Energy Physics (HEP). Bayes’s Theorem is a powerful tool for solving Inverse Problems, providing conceptually transparent and unbiased constraints on theoretical parameters and their uncertainties (“Bayesian Inference”) and enabling the quantification of agreement or tension between models and data. However, analyses based on Bayesian Inference are often challenging for NP and HEP applications, either because of the large number of parameters in the problem, the high computational cost, or both. We propose a multi-institutional collaboration to develop and deploy novel Bayesian analysis tools that advance the scientific scope of a broad range of current and future NP experiments. This project brings together NP domain scientists working on several high-profile NP projects for which new, high-performance Bayesian Uncertainty Quantification (“Bayesian UQ”) methods are essential to carry out the science, and data scientists who are developing state-of-the-art methods applicable to these problems. The NP projects in this proposal comprise measurements of the mass and fundamental nature of the neutrino; study of the Quark-Gluon Plasma that filled the early universe; and mapping of natural and anthropogenic radiation environments. While these NP projects have very different scientific goals, with datasets and analysis approaches that differ significantly, they share common requirements for improving computationally intensive Bayesian analyses using advanced Machine Learning algorithms and will benefit strongly from a coherent effort to develop general solutions. This proposal brings together these projects and forefront ML-based data science algorithms to develop such general solutions. The methods developed in this project will also be more widely applicable, thereby advancing science in the larger Nuclear Physics portfolio.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A database-informed approach to new plant shielding design

Document available in abstract form only, full text of document follows: To facilitate the definition and description of radiation dose rates in the numerous rooms and areas of a new nuclear power plant, a database approach was developed. This approach offers a number of benefits over more manual methods. A key benefit is that the selection of an appropriate shielding method to use in each area of the plant is greatly facilitated by virtue of the team's improved ability to grasp the significance of each of the individual sources that are candidates for making a significant contribution to the dose rate in each area. By understanding the level of relevant contribution - if any - of each of these candidate sources, an analyst is able to select a method that will define the contribution without becoming enmired in a model representing inappropriately high degrees of accuracy and modeling time. This database method, by allowing for an evolving understanding of dose rates and sources in the neighboring rooms for each portion of the plant, leads to substantial reductions in the effort of characterizing a plant's radiation environment. As an additional benefit, the database serves as a tool for documenting the shielding calculations themselves, automatically generating formatted sections including drawing and source term references, shielding calculation types, key dimensions, and results; these sections can form the starting point of a full calculation package. The approach offers a final project management benefit: estimating, tracking, and predicting the effort associated with the many calculations involved in such a project are greatly systematized, leading to more reliable manpower estimates. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of a 1.3 GHZ Normal-Conducting 5-Cell Standing-Wave Cavity

A 5-cell, normal-conducting, 1.3 GHz, standing-wave (SW) cavity was built as a prototype capture accelerator for the ILC positron source. Although the ILC uses predominantly superconducting cavities, the capture cavity location in both a high radiation environment and a solenoidal magnetic field requires it to be normal conducting. With the relatively high duty ILC beam pulses (1 msec at 5 Hz) and the high gradient required for efficient positron capture (15 MV/m), achieving adequate cavity cooling to prevent significant detuning is challenging. This paper presents the operational performance of this cavity including the processing history, characteristics of the breakdown events and the acceleration gradient witnessed by a single bunch at different injection times for different rf pulse lengths.

43 PARTICLE ACCELERATORS↗

Robotic Cleaning of the Total Dissolved Solids Tanks at the Palo Verde Nuclear Generating Station - 18337

Westinghouse is executing a contract from Arizona Public Services to provide a system capable of removing highly radioactive sediment from eight Total Dissolved Solids (TDS) Tanks located at the Palo Verde Nuclear Generating Station. The scope of work covers the design, procurement, fabrication, and eventual operation of the system at the Palo Verde Site. It also includes the factory acceptance testing of the system, prior to operation at the site. Previous attempts to clean the tanks involved working inside and around the tanks for extended periods of time in a high radiation field. Spray hoses were used to wash down the sediment, and hand tools were used to scrape out the remaining sludge at the bottom. This methodology also required the lower manway to be removed. As a result, the worker radiation exposure limit was exceeded on the first of the nine tanks. As a solution to the high radiation environment of the TDS tanks, Westinghouse will provide and operate a pneumatically powered robotic crawler. This crawler traverses the bottom of the tank with a 4,000 psi high-pressure spray head affixed to the front of the crawler to blast sediment from the walls and floor of the TDS tanks. This paper will present the conceptual design of the TDS Tank cleaning system, noting the key benefits of specific components in the overall technology basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MSL-RAD Cruise Operations Concept

The Mars Science Laboratory (MSL) payload includes the Radiation Assessment Detector (RAD) instrument, intended to fully characterize the radiation environment for the MSL mission. The RAD instrument operations concept is intended to reduce impact to spacecraft resources and effort for the MSL operations team. By design, RAD autonomously performs regular science observations without the need for frequent commanding from the Rover Compute Element (RCE). RAD operates with pre-defined "sleep" and "observe" periods, with an adjustable duty cycle for meeting power and data volume constraints during the mission. At the start of a new science observation, RAD performs a pre-observation activity to assess count rates for selected RAD detector elements. Based on this assessment, RAD can enter "solar event" mode, in which instrument parameters (including observation duration) are selected to more effectively characterize the environment. At the end of each observation period, RAD stores a time-tagged, fixed length science data packet in its non-volatile mass memory storage. The operating cadence is defined by adjustable parameters, also stored in non-volatile memory within the instrument. Periodically, the RCE executes an on-board sequence to transfer RAD science data packets from the instrument mass storage to the MSL downlink buffer. Infrequently, the RAD instrument operating configuration is modified by updating internal parameter tables and configuration entries.

Mars Science Laboratory (MSL)↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Experimental Facility Concept Revolutionizing Materials in Extremes

The planned Matter-Radiation Interactions in Extremes (MaRIE) facility at Los Alamos National Lab (LANL) is designed to fill a void in the materials research community. This void is the ability to study materials under extreme conditions (such as in high radiation environments). Ultimately, we want to be able to predict and control materials under extreme conditions. An example of where this capability is needed is in the performance of materials in advanced energy systems. The understanding of materials needs to move from the nano scale all the way to bulk systems. This talk discusses present capabilities for understanding materials at the Los Alamos Neutron Science Center (LANSCE) at LANL and the future capabilities MaRIE brings, including from the Multi-Probe Diagnostic Hall, the Fission, Fusion Materials Facility, and the Making, Measuring, Modeling and Materials Facility.

36 MATERIALS SCIENCE↗

Reactivity of the Hydrated Electron

Hydrated electrons are created in virtually every radiation environment and in many photochemical or electrochemical environments where liquid water is present, so their reaction products and reaction rate constants are naturally important in applications. Thanks to the strong optical absorbance of (e - ) aq , these rate constants are easy to measure, and a large database has been accumulated. It is not generally appreciated that no working theory of hydrated electron reaction rates presently exists. We discuss key experimental observations of hydrated electron reactions in the context of recent progress in theoretical and simulation developments toward understanding them, made possible by ever increasing computational power.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space Radiation Risk Assessment for Future Lunar Missions

For lunar exploration mission design, radiation risk assessments require the understanding of future space radiation environments in support of resource management decisions, operational planning, and a go/no-go decision. The future GCR flux was estimated as a function of interplanetary deceleration potential, which was coupled with the estimated neutron monitor rate from the Climax monitor using a statistical model. A probability distribution function for solar particle event (SPE) occurrence was formed from proton fluence measurements of SPEs occurred during the past 5 solar cycles (19-23). Large proton SPEs identified from impulsive nitrate enhancements in polar ice for which the fluences are greater than 2 10(exp 9) protons/sq cm for energies greater than 30 MeV, were also combined to extend the probability calculation for high level of proton fluences. The probability with which any given proton fluence level of a SPE will be exceeded during a space mission of defined duration was then calculated. Analytic energy spectra of SPEs at different ranks of the integral fluences were constructed over broad energy ranges extending out to GeV, and representative exposure levels were analyzed at those fluences. For the development of an integrated strategy for radiation protection on lunar exploration missions, effective doses at various points inside a spacecraft were calculated with detailed geometry models representing proposed transfer vehicle and habitat concepts. Preliminary radiation risk assessments from SPE and GCR were compared for various configuration concepts of radiation shelter in exploratory-class spacecrafts.

Kim, Myung-Hee Y.↗

Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility

Simultaneous measurements of the self-emission spectrum, the backlighting source spectrum, and the transmission spectrum in one shot, which reduce the experimental uncertainties from shot-to-shot fluctuation, are essential for precise opacity experiments. In order to achieve precise absorption spectrum of Al plasmas, a special half sample sandwich target was designed and short backlighter was used to provide time- and space-resolving diagnostics on the Shenguang II high power laser facility. In the measurement, a cylindrical cavity with CH foam baffles was used to provide a clean x-ray radiation environment for sample heating. The x-ray source spectrum, the transmission spectrum, and the self-emission spectrum of the soft x-ray heated Al sample were recorded in one shot with a penta-erythritol tetrakis (hydroxymethy) methane C(CH{sub 2}OH){sub 4} (PET) crystal spectrometer by using the point-projection method. Experimental results have been compared with the calculation results of a detailed level accounting opacity code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗