Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Solar photovoltaic powered refrigerators/freezers for medical use in remote geographic locations

One of the obstacles preventing widespread immunication against disease is the virtual absence of reliable, low maintenance refrigeration systems for storage of vaccines in remote geographic locations. A system which consists of a solar photovoltaic cell array and an integrated refrigerator/freezer-energy storage unit is discussed herein. The array converts solar radiation into direct current (DC) electricity with no moving parts and no intermediate steps. A detailed description of the refrigeration system, its design and an analysis thereof, performance test procedures, and test results are presented. A system schematic is also provided.

Darkazalli, G.↗

Status of DOE and AID stand-alone photovoltaic system field tests

The NASA Lewis Research Center (LeRC) is managing stand-alone photovoltaic (PV) system projects sponsored by the U.S. Department of Energy (DOE) and the U.S. Agency for International Development (AID). The DOE project includes village PV power demonstration projects in Gabon (four sites) and the Marshall Islands, and PV-powered vaccine refrigerator systems in six countries. The AID project includes a large village power system, a farmhouse system and two water pumping-irrigation systems in Tunisia, a water pumping/grain grinding system in Upper Volta, five medical clinic systems in four countries, PV-powered vaccine refrigerator systems in 18 countries and a PV-powered remote earth station in Indonesia. This paper reviews these PV projects and summarizes significant findings to date.

Bifano, W. J.↗

Design of a flight qualified long-life cryocooler

A second generation Stirling cycle cryogenic refrigerator with a linear drive, magnetic bearings, and clearance seals; designed to produce 5 watts of cooling at 65 Kelvin and to meet Space Shuttle mission requirements is described. The first generation refrigerator met all performance specifications, and operated with no failure for over 12,030 hours. Meeting launch requirements necessitated improvements in the electromagnetic bearings, the radial position sensors, and in the structural design of the moving elements. Organic contamination was eliminated by the use of all metal and ceramic construction. Reductions in system input power are attained by an integral magnetic spring/motor for the displacer and by more efficient linear motors and drive electronics.

Knox, L.↗

Charcoal/Nitrogen Adsorption Cryocooler

Refrigerator with no wear-related moving parts produces 0.5 W of cooling at 118 K. When fully developed, refrigerator needs no electrical power, and life expectancy of more than 10 yr, operates unattended to cool sensitive infrared detectors for long periods. Only moving parts in adsorption cryocooler are check valves. As charcoal is cooled in canister, gas pressure drops, allowing inlet check valve to open and admit more nitrogen. When canister is heated, pressure rises, closing inlet valve and eventually opening outlet valve.

Bard, Steven↗

Time-domain sensitivity enhancement in pulsed Pb-TDL gas monitors

A Pb-salt tunable diode laser (TDL) has found many applications in the field of atmospheric gas analysis. Its continuous tunablility and fine spectral purity in the mid infrared region are outstanding from other lasers. The only shortcoming is that it requires cryogenic operating temperatures, though, it is improved year by year towards the room temperature operation. A repeated pulse operation of Pb salt diode lasers is possible with a thermoelectric cooling device, which allows an instrument a portable geometry disusing a heavy, bulky and power consuming mechanical refrigerator. A derivative spectrometry was exploiting the quick tunability of Pb salt diode lasers, though they are continuous wave (cw) operated with refrigerator or liquid nitrogen so far. A new system for derivative spectrometry with a pulsed diode laser will extend its field of applications because of reduced weights and size of measuring instruments. A preliminary results is shown that demonstrates the feasibility of an attempt to implement the derivative spectrmetry with repeatedly pulse driven diode lasers. Atmospheric methane was measured with 8 ppm/m sensitivity. Further results of parametric optimization for the best signal to noise ratios under any given device characteristics as well as for available real devices is given.

Koga, R.↗

Mars transit vehicle thermal protection system: Issues, options, and trades

A Mars mission is characterized by different mission phases. The thermal control of cryogenic propellant in a propulsive vehicle must withstand the different mission environments. Long term cryogenic storage may be achieved by passive or active systems. Passive cryo boiloff management features will include multilayer insulation, vapor cooled shield, and low conductance structural supports and penetrations. Active boiloff management incorporates the use of a refrigeration system. Key system trade areas include active verses passive system boiloff management (with respect to safety, reliability, and cost) and propellant tank insulation optimizations. Technology requirements include refrigeration technology advancements, insulation performance during long exposure, and cryogenic fluid transfer system for mission vehicle propellant tanking during vehicle buildip in LEO.

Brown, Norman↗

Measured performance of the heat exchanger in the NASA icing research tunnel under severe icing and dry-air conditions

Measurements were made of the pressure drop and thermal perfomance of the unique refrigeration heat exchanger in the NASA Lewis Icing Research Tunnel (IRT) under severe icing and frosting conditions and also with dry air. This data will be useful to those planning to use or extend the capability of the IRT and other icing facilities (e.g., the Altitude Wind Tunnel-AWT). The IRT heat exchanger and refrigeration system is able to cool air passing through the test section down to at least a total temperature of -30 C (well below icing requirements), and usually up to -2 C. The system maintains a uniform temperature across the test section at all airspeeds, which is more difficult and time consuming at low airspeeds, at high temperatures, and on hot, humid days when the cooling towers are less efficient. The very small surfaces of the heat exchanger prevent any icing cloud droplets from passing through it and going through the tests section again. The IRT heat exchanger was originally designed not to be adversely affected by severe icing. During a worst-case icing test the heat exchanger iced up enough so that the temperature uniformaity was no worse than about +/- 1 deg C. The conclusion is that the heat exchanger design performs well.

Olsen, W.↗

Ames Research Center cryogenics program

Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.

Kittel, Peter↗

Air Force cryocooler development for spacecraft

An overview is given of Air Force sponsored cryocooler development for long duration spacecraft missions. Alternate approaches are being pursued to insure eventual success. The types of closed cycle cryocoolers that are now in advanced development include Vuilleumier, turbo-Brayton, and rotary-reciprocating refrigerators. Linear Stirling coolers with magnetic bearings have also been jointly sponsored by NASA and the Air Force. Technology is also being explored for future coolers using magnetic materials at low temperatures and for refrigerators with sorption compresssors. All of these cryocoolers are presently configured primarily for use with infrared sensor systems, but the designs could be adapted for use with cryogenic fluid storage systems or other applications.

Haskin, William L.↗

Long term orbital storage of cryogenic propellants for advanced space transportation missions

A comprehensive study has developed the major features of a large capacity orbital propellant depot for the space-based, cryogenic OTV. The study has treated both the Dual-Keel Space Station and co-orbiting platforms as the accommodations base for the propellant storage facilities, and trades have examined both tethered and hard-docked options. Five tank set concepts were developed for storing the propellants, and along with layout options for the station and platform, were evaluated from the standpoints of servicing, propellant delivery, boiloff, micrometeoroid/debris shielding, development requirements, and cost. These trades led to the recommendation that an all-passive storage concept be considered for the platform and an actively refrigerated concept providing for reliquefaction of all boiloff be considered for the Space Station. The tank sets are modular, each storing up to 45,400 kg of LO2/LH2, and employ many advanced features to provide for microgravity fluid management and to limit boiloff. The features include such technologies as zero-gravity mass gauging, total communication capillary liquid acquisition devices, autogenous pressurization, thermodynamic vent systems, thick multilayer insulation, vapor-cooled shields, solar-selective coatings, advanced micrometeoroid/debris protection systems, and long-lived cryogenic refrigeration systems.

Schuster, John R.↗

Current developments in NASA cryogenic cooler technology

Cooler technologies that are being developed by NASA to meet the varying temperature and cooling power requirements of NASA instruments are described. In addition to providing the desired operating temperature and cooling power by stabilizing temperatures from room temperature down to 0.1 K or less, these coolers will have working lifetimes commensurate with the 10 to 15 year lifetime expected for major future NASA facilities. The types of coolers currently under development are discussed, including radiative coolers, solid cryogen coolers, surface tension confined liquid cryogen coolers, mechanical coolers, liquid helium dewars, He3 adsorption coolers, adiabatic demagnetization refrigerators, and dilution refrigerators.

Castles, Stephen H.↗

An adiabatic demagnetization cooled bolometer system

An adiabatic demagnetization refrigeration (ADR) system suitable for cooling bolometers for use at infrared and submillimeter wavelengths is constructed. Because it does not rely on a gravitational field for operation, this refrigeration method has been proposed to cool bolometers intended for NASA's Space Infrared Telescope Facility. To explore the use of ADR in this manner, a portable instrument that has been used successfully for ground-based astronomical observations was constructed. By employing chromic potassium sulfate as a paramagnetic cooling material, bolometers were cooled to temperatures of 0.1 K with a cryogenic hold time of greater than nine hours.

Lesyna, L.↗

Carbon Sorption Cryogenic Regenerator

Liquid-helium refrigerator includes regenerator filled with carbon sorbent made from Saran polyvinylidene chloride. Material results in lower operating temperatures and longer times between maintenance than comparable refrigerators containing other regenerators. Sorbent material machined to various configurations to fit inside cylindrical regenerator can. Configuration chosen with regard to heat capacity, pressure drop, and rate of sorption.

Jones, Jack A.↗

Integrated Heat Switch/Oxide Sorption Compressor

Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.

Bard, Steven↗

Ceramic Wick For Capillary-Pumped Heat Pipe

Fibrous ceramic wick allows choice of working fluid and high-temperature fabrication and/or operation. Wick material resists degradation at temperatures from -195 to +1,500 degrees C. Liquid refrigerant fills bore of silica/alumina wick. After flowing by capillary action through pores of wick, refrigerant evaporates from finned outer surface of wick and enters heat pipe, flowing toward condenser section.

Seidenberg, Benjamin↗

Wind tunnel pressurization and recovery system

The high density, low toxicity characteristics of refrigerant-12 (dichlorofluoromethane) make it an ideal gas for wind tunnel testing. Present limitations on R-12 emissions, set to slow the rate of ozone deterioration, pose a difficult problem in recovery and handling of large quantities of R-12. This preliminary design is a possible solution to the problem of R-12 handling in wind tunnel testing. The design incorporates cold temperature condensation with secondary purification of the R-12/air mixture by adsorption. Also discussed is the use of Freon-22 as a suitable refrigerant for the 12 foot wind tunnel.

Pejack, Edwin R.↗

Feasibility analysis of reciprocating magnetic heat pumps

A reciprocating gadolinium core in a regeneration fluid column in the warm bore of a superconducting solenoidal magnet is considered for magnetic refrigeration in 3.517 MW (1000 ton) applications. A procedure is presented to minimize the amount of superconducting cable needed in the magnet design. Estimated system capital costs for an ideal magnetic refrigerator of this type become comparable to conventional chillers as the frequency of reciprocation approaches 10 Hertz. A 1-D finite difference analysis of a regenerator cycling at 0.027 Hertz is presented which exhibits some of the features seen in the experiments of G. V. Brown.

Larson, A. V.↗

Mechano-caloric cooling device

The mechano-caloric effect is potentially useful in the He II temperature range. Aside from demonstration work, little quantification effort appears to have been known since other refrigeration possibilities have been available for some time. Successful He II use-related system examples are as follows: in space, the utilization of the latent heat of vaporization has been quite successful in vapor-liquid phase separation (VLPS) in conjunction with thermomechanical force application in plugs. In magnet cooling systems, the possibility of using the mechano-caloric cooling effect in conjunction with thermo-mechanical circulation pump schemes, has been assessed (but not quantified yet to the extent desirable). A third example is quoted in conjunction with superfluid wind tunnel studies and liquid helium tow tank for surface vessels respectively. In all of these (partially future) R and D areas, the question of refrigerator effectiveness using the mechano-caloric effect appears to be relevant, possibly in conjunction with questions of reliability and simplicity. The present work is concerned with quantification of phenomena including simplified thermodynamic cycle calculations.

Frederking, T. H. K.↗