Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Co on Fe{sub 3}O{sub 4}(001): Towards precise control of surface properties

A novel approach to incorporate cobalt atoms into a magnetite single crystal is demonstrated by a combination of x-ray spectro-microscopy, low-energy electron diffraction, and density-functional theory calculations. Co is deposited at room temperature on the reconstructed magnetite (001) surface filling first the subsurface octahedral vacancies and then occupying adatom sites on the surface. Progressive annealing treatments at temperatures up to 733 K diffuse the Co atoms into deeper crystal positions, mainly into octahedral ones with a marked inversion level. The oxidation state, coordination, and magnetic moments of the cobalt atoms are followed from their adsorption to their final incorporation into the bulk, mostly as octahedral Co{sup 2+}. This precise control of the near-surface Co atoms location opens up the way to accurately tune the surface physical and magnetic properties of mixed spinel oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise measurement of single carbon nanocoils using focused ion beam technique

We have developed a precise resistivity measurement system for quasi-one-dimensional nanomaterials using a focused ion beam. The system enables the resistivity of carbon nanocoils (CNCs) to be measured and its dependence on coil geometry to be elucidated. At room temperature, the resistivity of CNCs tended to increase with coil diameter, while that of artificially graphitized CNCs remained constant. These contrasting behaviors indicate coil-diameter-induced enhancement in structural disorder internal to CNCs. Low-temperature resistivity measurements performed on the CNCs revealed that electron transport through the helical axis is governed by the variable range hopping mechanism. The characteristic temperature in variable range hopping theory was found to systematically increase with coil diameter, which supports our theory that the population of sp{sup 2}-domains in CNCs decreases considerably with coil diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High precision tilt stage as a key element to a universal test mirror for characterization and calibration of slope measuring instruments

The ultimate performance of surface slope metrology instrumentation, such as long trace profilers and auto-collimator based deflectometers, is limited by systematic errors that are increased when the entire angular range is used for metrology of significantly curved optics. At the ALS X-Ray Optics Laboratory, in collaboration with the HZB/BESSY-II and PTB (Germany) metrology teams, we are working on a calibration method for deflectometers, based on a concept of a universal test mirror (UTM) [V. V. Yashchuk et al., Proc. SPIE 6704, 67040A (2007)]. Potentially, the UTM method provides high performance calibration and accounts for peculiarities of the optics under test (e.g., slope distribution) and the experimental arrangement (e.g., the distance between the sensor and the optic under test). At the same time, the UTM calibration method is inherently universal, applicable to a variety of optics and experimental arrangements. In this work, we present the results of tests with a key component of the UTM system, a custom high precision tilt stage, which has been recently developed in collaboration with Physik Instrumente, GmbH. The tests have demonstrated high performance of the stage and its capability (after additional calibration) to provide angular calibration of surface slope measuring profilers over the entire instrumental dynamic range with absolute accuracy better than 30 nrad. The details of the stage design and tests are presented. We also discuss the foundation of the UTM method and calibration algorithm, as well as the possible design of a full scale UTM system.

47 OTHER INSTRUMENTATION↗

Impact of LF and HF noises of HeNe lasers on the operation of precise interferometers

In the paper there are analyzed factors limiting resolution of precise laser interferometers working either in low frequency LF or in high frequency HF range. It is shown that the influence of the laser tube noises, although substantial, is not the most important. The influence of the electronic circuitry and signal processing is also evaluated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SOLARIS 3-axis high load, low profile, high precision motorized positioner

A 3-axis optical table, shown in Figure 1, was designed, fabricated, and assembled for the SOLARIS synchrotron facility at the Jagiellonian University in Krakow, Poland. To accommodate the facility, the table was designed to be very low profile, as seen in Figure 2, and bear a high load. The platform has degrees of freedom in the vertical (Z) direction as well as horizontal transversal (X and Y) directions. The table is intended to sustain loads as large as 1500 kg which will be sufficient to support a variety of equipment to measure and facilitate synchrotron radiation. After assembly, the table was tested and calibrated to find its position error in the vertical direction. ADC has extensive experience designing and building custom complex high precision motion systems [1,2].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact, fiber-coupled, six degree-of-freedom measurement system for precision linear stage metrology

A compact, fiber-coupled, six degree-of-freedom measurement system which enables fast, accurate calibration, and error mapping of precision linear stages is presented. The novel design has the advantages of simplicity, compactness, and relatively low cost. This proposed sensor can simultaneously measure displacement, two straightness errors, and changes in pitch, yaw, and roll using a single optical beam traveling between the measurement system and a small target. The optical configuration of the system and the working principle for all degrees-of-freedom are presented along with the influence and compensation of crosstalk motions in roll and straightness measurements. Several comparison experiments are conducted to investigate the feasibility and performance of the proposed system in each degree-of-freedom independently. Comparison experiments to a commercial interferometer demonstrate error standard deviations of 0.33 μm in straightness, 0.14 μrad in pitch, 0.44 μradin yaw, and 45.8 μrad in roll.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: A precise instrument to determine the Planck constant, and the future kilogram

A precise instrument, called a watt balance, compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. We describe in this paper the fourth-generation watt balance at the National Institute of Standards and Technology (NIST), and report our initial determination of the Planck constant obtained from data taken in late 2015 and the beginning of 2016. A comprehensive analysis of the data and the associated uncertainties led to the SI value of the Planck constant, h = 6.626 069 83(22) × 10{sup −34} J s. The relative standard uncertainty associated with this result is 34 × 10{sup −9}.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Precise mass detector based on carbon nanooscillator

Precise mass detectors based on an amorphous carbon nanowires, which localized on the top of a tungsten tip were fabricated and investigated. The nanowires were grown in the scanning electron microscope (SEM) chamber using focused electron beam technique. The movement trajectories and amplitude-frequency characteristics of the carbon nanowire oscillators were visualized at low and ambient pressure using SEM and confocal laser scanning microscope (CLSM), respectevely. The SiO{sub 2} and TiO{sub 2} nanospheres were clamped on the top of the carbon nanowires. The manipulations of nanospheres were provided by means of dielectrophoretic force in SEM. The sensitivity of the mass detector based on the carbon nanowire oscillator was estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precise control of polymer coated nanopores by nanoparticle additives: Insights from computational modeling

Polymer-nanoparticle composites are a promising new class of materials for creation of controllable nano-patterned surfaces and nanopores. We use coarse-grained molecular dynamics simulations augmented with analytical theory to study the structural transitions of surface grafted polymer layers (brushes) induced by infiltration of nanoparticles that are attracted to the polymers in the layer. We systematically compare two different polymer brush geometries: one where the polymer chains are grafted to a planar surface and the other where the chains are grafted to the inside of a cylindrical nanochannel. We perform a comprehensive study of the effects of the material parameters such as the polymer chain length, chain grafting density, nanoparticle size, strength of attraction between nanoparticles and polymer monomers, and, in the case of the cylindrically grafted brush, the radius of the cylinder. We find a very general behavioral motif for all geometries and parameter values: the height of the polymer brush is non-monotonic in the nanoparticle concentration in solution. As the nanoparticle concentration increases, the brush height first decreases and after passing through a minimum value begins to increase, resulting in the swelling of the nanoparticle infused brush. These morphological features may be useful for devising tunable “smart” nano-devices whose effective dimensions can be reversibly and precisely adjusted by changing the nanoparticle concentration in solution. The results of approximate Self-Consistent Field Theory (SCFT) calculations, applicable in the regime of strong brush stretching, are compared to the simulation results. The SCFT calculations are found to be qualitatively, even semi-quantitatively, accurate when applied within their intended regime of validity, and provide a useful and efficient tool for modeling such materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision atomic beam density characterization by diode laser absorption spectroscopy

We provide experimental and theoretical details of a simple technique to determine absolute line-of-sight integrated atomic beam densities based on resonant laser absorption. In our experiments, a thermal lithium beam is chopped on and off while the frequency of a laser crossing the beam at right angles is scanned slowly across the resonance transition. A lock-in amplifier detects the laser absorption signal at the chop frequency from which the atomic density is determined. The accuracy of our experimental method is confirmed using the related technique of wavelength modulation spectroscopy. For beams which absorb of order 1% of the incident laser light, our measurements allow the beam density to be determined to an accuracy better than 5% and with a precision of 3% on a time scale of order 1 s. Fractional absorptions of order 10{sup −5} are detectable on a one-minute time scale when we employ a double laser beam technique which limits laser intensity noise. For a lithium beam with a thickness of 9 mm, we have measured atomic densities as low as 5 × 10{sup 4} atoms cm{sup −3}. The simplicity of our technique and the details we provide should allow our method to be easily implemented in most atomic or molecular beam apparatuses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of voltage-controlled magnetic anisotropy through precise control of Mg insertion thickness at CoFeB|MgO interface

We studied the impact of different insertion layers (Ta, Pt, and Mg) at the CoFeB|MgO interface on voltage-controlled magnetic anisotropy (VCMA) effect and other magnetic properties. Inserting a very thin Mg layer of 0.1–0.3 nm yielded a VCMA coefficient of 100 fJ/V-m, more than 3 times higher than the average values of around 30 fJ/V-m reported in Ta|CoFeB|MgO-based structures. Ta and Pt insertion layers also showed a small improvement, yielding VCMA coefficients around 40 fJ/V-m. Electrical, magnetic, and X-ray diffraction results reveal that a Mg insertion layer of around 1.2 nm gives rise to the highest perpendicular magnetic anisotropy, saturation magnetization, as well as the best CoFe and MgO crystallinity. Other Mg insertion thicknesses give rise to either under- or over-oxidation of the CoFe|MgO interface; a strong over-oxidation of the CoFe layer leads to the maximum VCMA effect. These results show that precise control over the Mg insertion thickness and CoFe oxidation level at the CoFeB|MgO interface is crucial for the development of electric-field-controlled perpendicular magnetic tunnel junctions with low write voltage.

36 MATERIALS SCIENCE↗

All-optical lithography process for contacting nanometer precision donor devices

In this article, we describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

36 MATERIALS SCIENCE↗

Nuclear magnetic resonance probe head design for precision strain control

Here, we present the design and construction of an NMR probe to investigate single crystals under strain at cryogenic temperatures. The probe head incorporates a piezoelectric-based apparatus from Razorbill Instruments that enables both compressive and tensile strain tuning up to strain values on the order of 0.3% with a precision of 0.001%. 75 As NMR in BaFe 2 As 2 reveals large changes to the electric field gradient and indicates that the strain is homogeneous to within 16% over the volume of the NMR coil.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable location channels to improve efficiency and precision for direct ∇ T e measurements and high spatial resolution T e -profile measurements using electron cyclotron emission

Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.

47 OTHER INSTRUMENTATION↗

Precision Flexure Stages Design for a Compact Multilayer Laue Lens Test Bed for Hard X-ray Nanofocusing

Both the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) and the Beijing Synchrotron Radiation Facility (BSRF) at Institute of High Energy Physics (IHEP) have a keen interest in the development of a compact Multilayer Laue Lens (MLL) test bed for hard x-ray nanofocusing. Recently, collaboration between ANL and IHEP, as a part of the Argonne Strategic Partnership Project (SPP) 85J05, has produced designs of precision flexure stages for a compact MLL test bed for hard x-ray nanofocusing using commercial flexural pivots and Argonne developed laminar nanopositioning flexures. Two sets of the new flexure stages will be built with the new designs, one for R&D activities at the BSRF for the new planned 6 GeV high energy photon source (HEPS) and one for upgrade of the existing MLL test bed at the APS x-ray optics test beamline. Mechanical design and preliminary test for the MLL test bed flexure stages for Argonne SPP project 85J05 are presented in this paper.

nanopositioning flexure stage↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗