Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Local Volt/VAR Control Under External Disturbances with High PV Penetration

Volt/var control (VVC) of smart PV inverter is becoming one of the most popular solutions to address the voltage challenges associated with high PV penetration. This work focuses on the local droop VVC recommended by the grid integration standards IEEE1547, rule21 and addresses their major challenges i.e. appropriate parameters selection under changing conditions, and the control being vulnerable to instability (or voltage oscillations) and significant steady state error (SSE). This is achieved by proposing a two-layer local real-time adaptive VVC that has two major features i.e. a) it is able to ensure both low SSE and control stability simultaneously without compromising either; and b) it dynamically adapts its parameters to ensure good performance in a wide range of external disturbances such as sudden cloud cover, cloud intermittency, and substation voltage changes. A theoretical analysis and convergence proof of the proposed control is also discussed. The proposed control is implementation friendly as it fits well within the integration standard framework and depends only on the local bus information. Furthermore, the performance is compared with the existing droop VVC methods in several scenarios on a large unbalanced 3-phase feeder with detailed secondary side modeling.

14 SOLAR ENERGY↗

Case Study: Nuclear-Renewable-Water Integration in Arizona

This document reports the application of the N-R HES software framework to a case study for Arizona Public Service (APS); the manager and part owner of the Palo Verde (PV) nuclear power plant. The case study is a work in progress of which this report presents a detailed description of the current model input data, assumptions and the corresponding results produced by the developed software framework. The goal of the report is, that with this information APS (together with INL) should be able to identify where more detailed data and more accurate model assumptions are necessary to reproduce all driving physical and economic phenomena in order to capture enough complexity of the reality to allow APS to use the results for their strategic decisions. The N-R HES software framework started being developed at INL two years ago [ref]. The framework has reached some level of maturity so that it can be applied to more than simple demonstration cases, e.g. real industry problems. Nevertheless, more capabilities are constantly added to accommodate the special needs of these challenging real life problems. The N-R HES framework is built on top of the RAVEN code [ref] and uses it as driver and workflow manager for all calculations. The framework has specifically been developed for the economic assessment of N-R HES systems. There are four main cornerstones of the N-R HES simulation framework: 1) generation of stochastic time series, 2) a probabilistic analysis and optimization set of algorithms available in RAVEN, 3) a set of models for representation of the physical behavior of N-R HES, and 4) a RAVEN plug-in that maps physical performance into economic performance called CashFlow. Within this framework, a broad spectrum of questions related to N-R HES can be addressed. One of the challenges currently of high interest is that the increasing penetration of variable renewables is altering the profile of the net demand (demand after removing all non curtailable renewable energy sources), with which the other generators on the grid have to cope. The N-R HES software framework is capable to analyze the potential feasibility of mitigating the resultant volatility in the net electricity demand. One possible solution to that problem currently intensively studied by the energy industry is adding stabilizing loads to the grid. These loads can be external industrial processes that are able to ramp production up and down quickly or adding variable internal loads that will lift the base load of the power plant. The latter is a possible solution currently studied by APS. APS if currently anticipating several challenges that will likely arise in the near future. One of them is, as mentioned, coping with the rapid growth of variable renewable energy (VRE) sources put on the grid. Although APS can sell its electricity for a fixed retail price to cover the local demand first, it also sells electricity in excess of the local demand at the Palo Verde energy hub. Due to the growing VRE penetration, the Palo Verde hub electricity spot price is negative more and more frequently. To mitigate this price volatility, APS is seeking to add more base load, so that the quantity of excess energy to be sold for prices potentially less than the internal retail price or even negative prices at the hub is reduced. A second challenge APS is facing is that their cooling water acquisition contract with the Sub Regional Operating Group (SROG) will expire soon and a renewal can only be done for a significantly higher price of the water. Therefore, APS is also seeking for alternative sources for their cooling water. An opportunity currently under investigation is to pump a limited quantity of brackish water from the regional ground water. Although much cheaper than the water from the new SROG contract, the salinity of the brackish water is so high that a blend of brackish and SROG water would need additional treatment to improve its quality for use in the cooling towers. An on-site reverse osmosis (RO) desalination plant is envisaged to reduce the salinity to an acceptable level. This report investigates the economic impact of such an RO plant. As one can see, the RO plant would help with both problems APS is facing: First, it would rise the APS base load helping to mitigate VRE induced hub price volatility. From this perspective, the RO plant can be seen as a stabilizing load on the grid as would be any other industrial process. Second, the RO’s goods, e.g. the clean water produced can be used by APS itself for a (hopefully) lower cost than 100% SROG water would be. The report will first describe the APS water procurement strategy in detail and lay out the possible alternative scenarios studied in this document. This is covered in Chapter 2. Next, in Chapter 3, the APS case model developed within the N-R HES software framework is described. This chapter includes also a description of the needed framework developments to accommodate the APS study.

97 MATHEMATICS AND COMPUTING↗

Sputter-Deposited Oxides for Interface Passivation of CdTe Photovoltaics

Commercial CdTe PV modules have polycrystalline thin films deposited on glass, and devices made in this format have exceeded 22% efficiency. Devices made by the authors with a magnesium zinc oxide window layer and tellurium back contact have achieved efficiency over 18%, but these cells still suffer from an open-circuit voltage far below ideal values. Oxide passivation layers made by sputter deposition have the potential to increase voltage by reducing interface recombination. CdTe devices with these passivation layers were studied with photoluminescence (PL) emission spectroscopy and time-resolved photoluminescence (TRPL) to detect an increase in minority carrier lifetime. Because these oxide materials exhibit barriers to carrier collection, micropatterning was used to expose small point contacts while still allowing interface passivation. TRPL decay lifetimes have been greatly enhanced for thin polycrystalline absorber films with interface passivation. Device performance was measured and current collection was mapped spatially by light-beam-induced current.

14 SOLAR ENERGY↗

Human Health Science Building Geothermal Heat Pump Systems

The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

15 GEOTHERMAL ENERGY↗

The Salem Smart Power Center: An Assessment of Battery Performance and Economic Potential

This paper presents an assessment of the economic potential of a 5 MW/1.25 MWh Energy Storage System (ESS) installed at the Salem Smart Power Center (SSPC), a smart grid technology demonstration facility owned and operated by Portland General Electric (PGE) in Salem, Oregon. The ESS and the grid conditions in which it operates were modeled using Pacific Northwest National Laboratory’s Battery Storage Evaluation Tool (BSET) to explore tradeoffs between services, and to develop optimal control strategies. This assessment monetized the value derived from nine services the SSPC could provide to PGE and the customers it serves. The ESS and the grid conditions in which it operates were modeled using PNNL’s in-house optimization tool BSET to explore tradeoffs between services, and to develop optimal control strategies. The analysis resulted in a number of lessons that provide crucial insights into the practical application of ESS, including; The SSPC, which was originally conceived as a research and test facility and built with the prevailing maturity technology level, was built at a cost ($20.4 million) that exceeds current day prices ($5.4 million) for a similarly designed and built 5 MW/1.25 MWh system; In terms of economic operation, the SSPC is currently underutilized, deployed only for primary frequency response. PNNL modeling indicates that optimal operation of the ESS could generate an additional value of $2.3 million over 20 years. It should also be noted that primary frequency response is the highest benefit application but requires a response from the SSPC only 17 hours each year. While optimally engaged, the ESS would provide arbitrage and ancillary services 78 percent of the time, but those services generate only 27 percent of the total value; Participation in Western EIM represents an interesting opportunity for PGE with a potential to generate $2.1 million value in PV terms over 20 years in the 5-min real-time market; With an energy to power ratio of only 0.25, the SSPC is not well suited to engage in most energy-intensive applications such as arbitrage or ancillary services. By upsizing the storage capacity to 5 MWh and 10MWh, the additional value allows the benefits ($13.3 million and 20.3 million, respectively) to exceed the system’s revenue requirements ($11.5 and $16.4 million, respectively). For the SSPC, ROI ratios exceeded 1.0 when the energy to power ratio fell between 0.5 and 3.5, and peaked at an energy to power ratio of 2.0. This report represents the output of the first of a two-phase effort. Phase II will involve the development of enhanced control strategies to assist PGE in realizing the benefits of energy storage in real-time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Advisor Model (SAM) General Description (Version 2017.9.5)

This document describes the capabilities of the System Advisor Model (SAM) developed and distributed by the U.S. Department of Energy's National Renewable Energy Laboratory. The document is for potential users and others wanting to learn about the model's capabilities. SAM is a techno-economic computer model that calculates performance and financial metrics of renewable energy projects. Project developers, policy makers, equipment manufacturers, and researchers use graphs and tables of SAM results in the process of evaluating financial, technology, and incentive options for renewable energy projects. SAM simulates the performance of photovoltaic, concentrating solar power, solar water heating, wind, geothermal, biomass, and conventional power systems. The financial models are for projects that either buy and sell electricity at retail rates (residential and commercial) or sell electricity at a price determined in a power purchase agreement (PPA). SAM's simulation tools facilitate parametric and sensitivity analyses, Monte Carlo simulation and weather variability (P50/P90) studies. SAM can also read input variables from Microsoft Excel worksheets. For software developers, the SAM software development kit (SDK) makes it possible to use SAM simulation modules in their applications written in C/C plus plus, C sharp, Java, Python, MATLAB, and other languages. NREL provides both SAM and the SDK as free downloads at https://sam.nrel.gov. SAM is an open source project, so its source code is available to the public. Researchers can study the code to understand the model algorithms, and software programmers can contribute their own models and enhancements to the project. Technical support and more information about the software are available on the website.

47 OTHER INSTRUMENTATION↗

Land-Based Wind Market Report: 2021 Edition

The U.S. Department of Energy's 2021 edition of its land-based wind market report provides an overview of key trends in the U.S. wind power market, with a focus on 2020. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Highlights of this year’s update include: -Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a record pace in 2020, with 25 billion dollars invested in 16.8 GW of capacity. Wind energy output rose to account for more than 8% of the entire nation’s electricity supply, and is more than 20% in 10 states. At least 209 GW of wind are seeking transmission interconnection; 61 GW of this capacity are offshore wind and 13 GW are hybrid plants that pair wind with storage or PV. -Wind project performance has increased over time: The average capacity factor among recently built projects was over 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. -Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2010, no turbines employed blades that were 115 meters in diameter or larger, but in 2020, 91% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. -Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices are averaging 775–850 dollars/kW. The average installed cost of wind projects in 2020 was 1,460 dollars/kW, down more than 40% since the peak in 2010, though stable for the last three years. The lowest costs were found in Texas and the (non-ISO) West. -Wind energy prices remain low, around 20 dollars/MWh in the interior of the country: After topping out at 70 dollars/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped. In the interior ‘wind belt’ of the country, recent pricing is around 20 dollars/MWh. In the West and East, prices tend to average 30 dollars/MWh or more. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. -Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind declined in 2020, following natural gas prices lower and averaging under 15 dolalrs/MWh in ERCOT, MISO, NYISO and SPP; higher values were seen in CAISO, ISO-NE and PJM. -The average levelized cost of wind energy is down to 33 dollars/MWh: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography, but the national average stood at 33 dollars/MWh in 2020—down substantially historically, though consistent with the previous two years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. -The health and climate benefits of wind in 2020 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of 76 dollars/MWh-wind nationwide in 2020. -The domestic supply chain for wind equipment is diverse: For wind projects recently installed in the U.S., domestically manufactured content is highest for nacelle assembly (>85%), towers (60-75%), and blades and hubs (30-50%), but is much lower for most components internal to the nacelle.

17 WIND ENERGY↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Efficiency, Low-Cost III-V Solar Cells by Dynamic Hydride Vapor Phase Epitaxy Coupled with Rapid, Polishing-Free Wafer Reuse through Orientation-Optimized (110) Spalling

We demonstrated (110) GaAs solar cells grown by D-HVPE with equivalent performance and material quality relative to (100) devices. Also, we developed a procedure for repeatable wafer-scale spalling of (110) GaAs. Spalled surfaces were free of the facets founds in (100) GaAs spalling, the large arrest lines found in (100) Ge spalling, and surface features greater than 3 µm in peak-to-valley height, which can otherwise degrade the efficiency of regrown III-V devices. A sub-µm step-terrace morphology was discovered on the post-spall wafer surface, resulting from the restricted cleavage system of GaAs, but we developed understanding of the factors that determine the resulting morphology, enabling ample opportunity for optimization of morphologies suitable for device growth and spall depth waste minimization on (110) GaAs. Lastly, we demonstrated a device grown on a previously spalled surface with only 8% relative efficiency difference to a cell grown on a new unspalled wafer. Significant optimization of the substrate regrowth conditions are required to enable higher efficiency, but these results highlight the promise of (110)-oriented devices coupled with substrate reuse by spalling as a pathway for low-cost III-V photovoltaics.

14 SOLAR ENERGY↗

Solar 2 Green Energy, Arts & Education Center. Final Scientific/Technical Report

The Solar 2 Green Energy, Arts and Education Center is an 8,000 sq.ft. demonstration project that will be constructed to Platinum LEED certification and will be the first carbon-neutral, net-zero energy use public building in New York City, giving it local and national appeal. Employing green building features and holistic engineering practices throughout its international award-winning design, Solar 2 will be powered by a 90kW photovoltaic (PV) array in conjunction with a geothermal heating and cooling system and a high efficient design that seeks to reduce the overall energy load of the building. Solar 2 will replace our current 500 sq.ft. prototype facility - known as Solar 1 - as the educational and cultural centerpiece of a five-block public greenway on the East River in Stuyvesant Cove Park, located along two acres of public riverfront on a newly reclaimed, former brownfield in lower Manhattan. Designed as a public-use complex for year-round environmental education exhibits and onsite activities for all ages and backgrounds, Solar 2 will demonstrate energy-efficiency technologies and sustainable environmental practices available now to all urban residents, eco-tourists, teachers, and students alike. Showcasing one of Solar 2's most striking design elements is the PV roof array with a cafe and river vistas for miles of New York City's skylines. Capping the building as a solar-powered landmark, and visible from the FDR Drive, the PV array is also designed to provide visitors below a view of the solar roof when standing outside, as well as directly underneath it. Recognized by an international jury of architects, civil engineers and urban designers by the Swiss-based Holcim Foundation, the Solar 2 design was awarded the prestigious Holcim North American 2008 Gold Award for Sustainable Construction for innovative, future-oriented and tangible sustainable construction projects, selected from more than 1900 entries. Funding from the Department of Energy was provided to assist with the ongoing design work of Solar 2, including architecture, engineering and the development of construction specifications. The work performed during the project period brought this process as far along as it could go pending the raising of funds to begin construction of the building. Once those funds are secured, we will finalize any additional details needed before beginning the bidding process and then moving into construction. DOE's funding was extremely valuable in helping Solar One determine the feasibility of a net-zero construction on the site and allowed for the design to project to meet the high standards necessary for LEED Platinum status.

14 SOLAR ENERGY↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Collaboration to Enable Higher Penetrations of Solar Power Generation Using the Natural Gas Pipeline System for Energy Storage (CRADA CRD-14-00567)

This unique project explored one possible solution for photovoltaic (PV) generation to become a reliable and dispatchable energy resource similar to conventional baseload fossil fuel electricity generation. Solar power generation is a renewable resource that varies naturally from day-to-day as well as seasonally. To use solar power as a baseload generation asset requires a flexible storage system that can recover power on both a daily and seasonal basis. Converting solar power to natural gas (i.e., first to hydrogen and then to methane) and having access to utility-scale storage in the natural gas network has the potential to make solar power generation a baseload asset. This will: 1) Increase the net energy yield from solar resources by increasing the effective capacity factor and maximize the energy produced during the assets’ lifetimes. 2) Improve the economics of energy storage for solar project developers, thereby accelerating the deployment of new solar generation. 3) Reduce the impact of increasing solar penetration on congestion of the electrical transmission system by shifting power delivery in time using the gas pipeline network for long-duration storage. 4) Reduce the impact of increasing solar generation on electrical distribution system control. 5) Offer alternative revenue sources for solar power generation beyond electricity including: hydrogen (H 2 ) production for stationary fuel cells and fuel cell electric vehicles, conversion of carbon dioxide (CO 2 ) to methane (CH 4 ) as a direct drop-in replacement for fossil natural gas use, and transmission as high volumetrically-dense CH 4 for use in transportation, heating, power generation, chemical production or conversion back to H2 at the point of use. Additional work was added to this CRADA in modification 4 having a primary objective to characterize the performance of the electrolyzer, Southern California Gas (SoCalGas) bioreactor and balance of plant to demonstrate production of renewable natural gas (RNG) from renewable H 2 and CO 2 using single-cell, self-replicating organisms. The additional scope of work allowed researchers to ramp up gas flowrates and pressure of the system over the designed range to grow the cells and begin to show the load-following capabilities of this anaerobic gas fermentation process. These activities enabled the research team to predict system performance at much greater scales; namely 10’s of mega-watts (MWs) of electrolyzer nameplate capacity.

14 SOLAR ENERGY↗

Regional Analysis of Building Distributed Energy Costs and CO2 Abatement: A U.S. - China Comparison

The following paper conducts a regional analysis of the U.S. and Chinese buildings? potential for adopting Distributed Energy Resources (DER). The expected economics of DER in 2020-2025 is modeled for a commercial and a multi-family residential building in different climate zones. The optimal building energy economic performance is calculated using the Distributed Energy Resources Customer Adoption Model (DER CAM) which minimizes building energy costs for a typical reference year of operation. Several DER such as combined heat and power (CHP) units, photovoltaics, and battery storage are considered. The results indicate DER have economic and environmental competitiveness potential, especially for commercial buildings in hot and cold climates of both countries. In the U.S., the average expected energy cost savings in commercial buildings from DER CAM?s suggested investments is 17percent, while in Chinese buildings is 12percent. The electricity tariffs structure and prices along with the cost of natural gas, represent important factors in determining adoption of DER, more so than climate. High energy pricing spark spreads lead to increased economic attractiveness of DER. The average emissions reduction in commercial buildings is 19percent in the U.S. as a result of significant investments in PV, whereas in China, it is 20percent and driven by investments in CHP. Keywords: Building Modeling and Simulation, Distributed Energy Resources (DER), Energy Efficiency, Combined Heat and Power (CHP), CO2 emissions 1. Introduction The transition from a centralized and fossil-based energy paradigm towards the decentralization of energy supply and distribution has been a major subject of research over the past two decades. Various concerns have brought the traditional model into question; namely its environmental footprint, its structural inflexibility and inefficiency, and more recently, its inability to maintain acceptable reliability of supply. Under such a troubled setting, distributed energy resources (DER) comprising of small, modular, electrical renewable or fossil-based electricity generation units placed at or near the point of energy consumption, has gained much attention as a viable alternative or addition to the current energy system. In 2010, China consumed about 30percent of its primary energy in the buildings sector, leading the country to pay great attention to DER development and its applications in buildings. During the 11th Five Year Plan (FYP), China has implemented 371 renewable energy building demonstration projects, and 210 photovoltaics (PV) building integration projects. At the end of the 12th FYP, China is targeting renewable energy to provide 10percent of total building energy, and to save 30 metric tons of CO2 equivalents (mtce) of energy with building integrated renewables. China is also planning to implement one thousand natural gas-based distributed cogeneration demonstration projects with energy utilization rates over 70percent in the 12th FYP. All these policy targets require significant DER systems development for building applications. China?s fast urbanization makes building energy efficiency a crucial economic issue; however, only limited studies have been done that examine how to design and select suitable building energy technologies in its different regions. In the U.S., buildings consumed 40percent of the total primary energy in 2010 [1] and it is estimated that about 14 billion m2 of floor space of the existing building stock will be remodeled over the next 30 years. Most building?s renovation work has been on building envelope, lighting and HVAC systems. Although interest has emerged, less attention is being paid to DER for buildings. This context has created opportunities for research, development and progressive deployment of DER, due to its potential to combine the production of power and heat (CHP) near the point of consumption and delivering multiple benefits to customers, such as cost

25 ENERGY STORAGE↗

Dynamic Braking System of a Tidal Generator

Renewable energy generation has experienced significant cost reductions during the past decades, and it has become more accepted by the global population. In the beginning, wind generation dominated the development and deployment of renewable energy; however, during recent decades, photovoltaic (PV) generation has grown at a very significant pace due to the tremendous decrease in the cost of PV modules. The focus on renewable energy generation has now expanded to include new types with promising future applications, such as river and tidal generation. The input water flow to these types of resources is more predictable than wind or solar generation. The data used in this paper is representative of a typical river or tidal generator. The analysis is based on a generator with a power rating of 40 kW. The tidal generator under consideration is driven by two sets of helical turbines connected to each side of the generator located in between the turbines. The generator is operated in variable speed, and it is controlled to maximize the energy harvested as well as the operation of the turbine generator. The electrical system consists of a three-phase permanent magnet generator connected to a three-phase passive rectifier. The output of the rectifier is connected to a DC-DC converter to match the rectifier output to the DC bus voltage of the DC-AC inverter. The three-phase inverter is connected to the grid, and it is controlled to provide a good interface with the grid. One important aspect of river and tidal generation is the braking mechanism. In a tidal generator, the braking mechanism is important to avoid a runaway condition in case the connection to the grid is lost when there is a fault in the lines. A runaway condition may lead to an overspeed condition and cause extreme stresses on the turbine blade structure and eventual disintegration of the mechanical structure. In this paper, the concept of the dynamic braking system is developed and investigated for normal and abnormal operations. The main objective is to optimize the performance under emergency braking while designing the system to be as simple as possible to avoid overdesigning the power electronics or exceeding the target budget.

13 HYDRO ENERGY↗

Extracting and Generating PV Soiling Profiles for Analysis, Forecasting, and Cleaning Optimization

The identification and prediction of the daily soiling profiles of a photovoltaic site is essential to plan the optimal cleaning schedule. In this article, we analyze and propose various methods to extract and generate photovoltaic soiling profiles, in order to improve the analysis and the forecast of the losses. New soiling rate extraction methods are proposed to reflect the seasonal variability of the soiling rates and, for this reason, are found to identify the most convenient cleaning day with the highest accuracy for the investigated sites. Also, we present an approach that could be used to predict future soiling losses through the implementation of stochastic weather generation algorithms whose ability to identify in advance the best cleaning schedule is also successfully tested. The methods presented in this article can optimize the operation and maintenance schedule and could make it possible, in the future, to predict soiling losses through analysis based only on environmental parameters, such as rainfall and particulate matter, without the need of long-term soiling data.

14 SOLAR ENERGY↗

Land-Based Wind Market Report: 2022 Edition

The U.S. Department of Energy's 2022 edition of its Land-Based Wind Market Report provides an overview of key trends in the U.S. wind power market, with a focus on 2021. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Despite ongoing supply chain challenges, wind energy in 2021 continued to see strong growth, technology improvements, and low prices in the U.S. Key highlights include: Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a strong pace in 2021, with the 13.4 GW of new additions representing a $\$20$ billion investment and 32% of all newly added U.S. generation capacity. Wind energy output rose to account for more than 9% of the entire nation’s electricity supply. At least 247 GW of wind are seeking transmission interconnection; 77 GW of this capacity are offshore wind and 19 GW are hybrid plants that pair wind with storage or solar PV. Wind project performance has increased over the decades: The average capacity factor among recently built projects was nearly 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2011, no turbines employed blades that were 115 meters in diameter or larger, but in 2021, 89% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices averaged $\$800$–$\$950$/kW in 2021, a 5% to 10% increase from the year prior but substantially lower than in 2010. The average installed cost of wind projects in 2021 was $\$1,500$/kW, down more than 40% since the peak in 2010, though relatively stable in recent years. The lowest costs were found in Texas and the (non-ISO) West. Wind energy prices are on the rise, but generally remain low, around $\$20$/MWh in the interior of the country with higher prices in the West and East. After topping out above $\$75$/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped—though supply-chain pressures have resulted in increased prices in recent years. In the interior ‘wind belt’ of the country, recent pricing is around $\$20$/MWh. In the West and East, prices tend to average above $\$30$/MWh. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind increased in 2021, averaging $\$16$/MWh in MISO, $\$19$/MWh in SPP, $\$23$/MWh in NYISO, $\$31$/MWh in ERCOT, $\$33$/MWh in PJM, $\$44$/MWh in ISO-NE, and $\$48$/MWh in CAISO. The average levelized cost of wind energy was $\$32$/MWh for plants built in 2021: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography. The national average stood at $\$32$/MWh in 2021—down substantially historically, though relatively stable in recent years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. The health and climate benefits of wind in 2021 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of over $\$90$/MWh-wind for plants built in 2021.

17 WIND ENERGY↗

Seminar 13 - Advanced Methods for Grid Integration of High-Performance Residential Communities

High-performance residential communities such as net-zero energy (NZE) and NZE-ready communities are emerging across the United States as many cities and states have committed to achieve ambitious energy efficiency and renewable energy goals between now and 2050. The achievement of these goals will transform the nation's communities into the holistic paradigms consisting of pervasive solar photovoltaics (PVs) and other renewable distributed energy resources, energy storage and flexible loads. However, integrating residential communities with high PV penetration may bring many challenges to the grid. For example, during many hours of the year, electric power is flowing out of PV-enabled homes and back into the grid. When this happens simultaneously in many nearby homes, distribution feeder voltage can be raised significantly. Intermittent solar power can also cause voltage flickers, leading to potential damages on both distribution feeder and home appliances. Existing solutions, such as PV curtailment, battery storage, and direct load control, are not able to address all the challenges in a cost-effective way. Better understanding is needed on how to deploy rooftop PV, how to predict building loads, and how to coordinate the homes in a community to enhance grid reliability. This seminar consists of four integral presentations that cover different aspects of a solution to these challenges. First, we will present an automated method to identify the best surfaces to deploy PV and size PV according to the PV penetration goals in a community. Second, we will present a streamlined way to create gray-box building models that are suitable for large-scale building-grid co-simulation. Next, we will present a data-driven method to estimate the end-use energy consumption to better coordinate the behind-the-meter resources to reduce utility cost, provide grid services, and improve renewable energy integration. Lastly, we will present a hierarchical control system that integrates the building models and the estimated non-dispatchable loads into the decision-making process to enhance the reliability and resilience of the residential community. Simulation results from an NZE-ready community in Fort Collins, Colorado will be presented in all four presentations and the guidelines on better grid integration of residential communities will be provided.

14 SOLAR ENERGY↗