Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERSONAL COMPUTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Predicting Individual Affect of Health Interventions to Reduce HPV Prevalence

Recently, human papilloma virus has been implicated to cause several throat and oral cancers and hpv is established to cause most cervical cancers. A human papilloma virus vaccine has been proven successful to reduce infection incidence in FDA clinical trials and it is currently available in the United States. Current intervention policy targets adolescent females for vaccination; however, the expansion of suggested guidelines may extend to other age groups and males as well. This research takes a first step towards automatically predicting personal beliefs, regarding health intervention, on the spread of disease. Using linguistic or statistical approaches, sentiment analysis determines a texts affective content. Self-reported HPV vaccination beliefs published in web and social media are analyzed for affect polarity and leveraged as knowledge inputs to epidemic models. With this in mind, we have developed a discrete-time model to facilitate predicting impact on the reduction of HPV prevalence due to arbitrary age and gender targeted vaccination schemes.

59 BASIC BIOLOGICAL SCIENCES↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

Software Requirements for a Consequence Management Sample Data Simulator for Training and Drills

This document describes the requirements for a software tool that will enable FRMAC to simulate large sets of sample result data that is based realistically on simulated radionuclide deposition grids from NARAC. The user of this tool would be scientists involved in exercise and drill planning or part of the simulation cell of an exercise controller team. A key requirement is that this tool must be able to be run with a reasonable amount of training and job aids by any person within the Assessment, Laboratory Analysis, or Monitoring and Sampling divisions of the FRMAC to support any level of exercise from the small IPX to the national level full scale exercise. This tool should be relatively lean and stand-alone so that the user can run it in the field with limited IT resources. This document will describe the desired architecture, design characteristics, order of operations, and algorithms that can be given to a software development team to assist them in project scoping, costing, and eventually, development.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy Sciences Network (ESnet): Nuclear Physics Network Requirements Review Report

In May 2019, ESnet and the Office of Nuclear Physics (NP) of the DOE Office of Science organized an ESnet requirements review of NP-supported activities. Preparation for this event included identification of key stakeholders to the process: program and facility management, research groups, technology providers, and a number of external observers. These individuals were asked to prepare formal case study documents about their relationship to the NP program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward. A series of pre-planning meetings better prepared case study authors for this task and facilitated a smooth transition to the in-person review.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Concomitant Imaging Dose and Cancer Risk in Image Guided Thoracic Radiation Therapy

Purpose: Kilovoltage cone beam computed tomography (CT) (kVCBCT) imaging guidance improves the accuracy of radiation therapy but imposes an extra radiation dose to cancer patients. This study aimed to investigate concomitant imaging dose and associated cancer risk in image guided thoracic radiation therapy. Methods and Materials: The planning CT images and structure sets of 72 patients were converted to CT phantoms whose chest circumferences (C{sub chest}) were calculated retrospectively. A low-dose thorax protocol on a Varian kVCBCT scanner was simulated by a validated Monte Carlo code. Computed doses to organs and cardiac substructures (for 5 selected patients of various dimensions) were regressed as empirical functions of C{sub chest}, and associated cancer risk was calculated using the published models. The exposures to nonthoracic organs in children were also investigated. Results: The structural mean doses decreased monotonically with increasing C{sub chest}. For all 72 patients, the median doses to the heart, spinal cord, breasts, lungs, and involved chest were 1.68, 1.33, 1.64, 1.62, and 1.58 cGy/scan, respectively. Nonthoracic organs in children received 0.6 to 2.8 cGy/scan if they were directly irradiated. The mean doses to the descending aorta (1.43 ± 0.68 cGy), left atrium (1.55 ± 0.75 cGy), left ventricle (1.68 ± 0.81 cGy), and right ventricle (1.85 ± 0.84 cGy) were significantly different (P<.05) from the heart mean dose (1.73 ± 0.82 cGy). The blade shielding alleviated the exposure to nonthoracic organs in children by an order of magnitude. Conclusions: As functions of patient size, a series of models for personalized estimation of kVCBCT doses to thoracic organs and cardiac substructures have been proposed. Pediatric patients received much higher doses than did the adults, and some nonthoracic organs could be irradiated unexpectedly by the default scanning protocol. Increased cancer risks and disease adverse events in the thorax were strongly related to higher imaging doses and smaller chest dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Cyber Friendly Fire

Cyber friendly fire (FF) is a new concept that has been brought to the attention of Department of Defense (DoD) stakeholders through two workshops that were planned and conducted by the Air Force Research Laboratory (AFRL) and research conducted for AFRL by the Pacific Northwest National Laboratory. With this previous work in mind, we offer a definition of cyber FF as intentional offensive or defensive cyber/electronic actions intended to protect cyber systems against enemy forces or to attack enemy cyber systems, which unintentionally harms the mission effectiveness of friendly or neutral forces. Just as with combat friendly fire, a fundamental need in avoiding cyber FF is to maintain situation awareness (SA). We suggest that cyber SA concerns knowledge of a system's topology (connectedness and relationships of the nodes in a system), and critical knowledge elements such as the characteristics and vulnerabilities of the components that comprise the system (and that populate the nodes), the nature of the activities or work performed, and the available defensive (and offensive) countermeasures that may be applied to thwart network attacks. A training implication is to raise awareness and understanding of these critical knowledge units; an approach to decision aids and/or visualizations is to focus on supporting these critical knowledge units. To study cyber FF, we developed an unclassified security test range comprising a combination of virtual and physical devices that present a closed network for testing, simulation, and evaluation. This network offers services found on a production network without the associated costs of a real production network. Containing enough detail to appear realistic, this virtual and physical environment can be customized to represent different configurations. For our purposes, the test range was configured to appear as an Internet-connected Managed Service Provider (MSP) offering specialized web applications to the general public. The network is essentially divided into a production component that hosts the web and network services, and a user component that hosts thirty employee workstations and other end devices. The organization's network is separated from the Internet by a Cisco ASA network security device that both firewalls and detects intrusions. Business sensitive information is stored in various servers. This includes data comprising thousands of internal documents, such as finance and technical designs, email messages for the organization's employees including the CEO, CFO, and CIO, the organization's source code, and Personally Identifiable client data. Release of any of this information to unauthorized parties would have a significant, detrimental impact on the organization's reputation, which would harm earnings. The valuable information stored in these servers pose obvious points of interest for an adversary. We constructed several scenarios around this environment to support studies in cyber SA and cyber FF that may be run in the test range. We describe mitigation strategies to combat cyber FF including both training concepts and suggestions for decision aids and visualization approaches. Finally, we discuss possible future research directions.

99 GENERAL AND MISCELLANEOUS↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Creating a Software Framework for Simulating Satellite Geolocation

It is hard to imagine life these days without having some sort of electronic indication of one's current location. Whether the purpose is for business, personal, or emergency use, utilizing smart cell phones, in-vehicle navigation systems, or location beacons, dependence on the Global Positioning System (GPS) is pervasive. Yet the availability of the GPS should not be taken for granted. Both environmental (e.g., terrain, weather) and intentional interference (i.e., jamming) can reduce or deny satellite access. In order to investigate these and other issues, as well as to explore possible alternative satellite constellations, an application called the Satellite Simulation Toolkit (SatSim) was created. This paper presents a high-level overview of SatSim and an example of how it may be used to study geolocation.

97 MATHEMATICS AND COMPUTING↗

Increased walking variability in elderly persons with congestive heart failure

OBJECTIVES: To determine the effects of congestive heart failure on a person's ability to walk at a steady pace while ambulating at a self-determined rate. SETTING: Beth Israel Hospital, Boston, a primary and tertiary teaching hospital, and a social activity center for elderly adults living in the community. PARTICIPANTS: Eleven elderly subjects (aged 70-93 years) with well compensated congestive heart failure (NY Heart Association class I or II), seven elderly subjects (aged 70-79 years) without congestive heart failure, and 10 healthy young adult subjects (aged 20-30 years). MEASUREMENTS: Subjects walked for 8 minutes on level ground at their own selected walking rate. Footswitches were used to measure the time between steps. Step rate (steps/minute) and step rate variability were calculated for the entire walking period, for 30 seconds during the first minute of the walk, for 30 seconds during the last minute of the walk, and for the 30-second period when each subject's step rate variability was minimal. Group means and 5% and 95% confidence intervals were computed. MAIN RESULTS: All measures of walking variability were significantly increased in the elderly subjects with congestive heart failure, intermediate in the elderly controls, and lowest in the young subjects. There was no overlap between the three groups using the minimal 30-second variability (elderly CHF vs elderly controls: P < 0.001, elderly controls vs young: P < 0.001), and no overlap between elderly subjects with and without congestive heart failure when using the overall variability. For all four measures, there was no overlap in any of the confidence intervals, and all group means were significantly different (P < 0.05).

NASA Discipline Cardiopulmonary↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques

Skin dose is one of the key issues for clinical dosimetry in radiation therapy. Currently planning computer systems are unable to accurately predict dose in the buildup region, leaving ambiguity as to the dose levels actually received by the patient's skin during radiotherapy. This is one of the prime reasons why in vivo measurements are necessary to estimate the dose in the buildup region. A newly developed metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector designed specifically for dose measurements in rapidly changing dose gradients was introduced for accurate in vivo skin dosimetry. The feasibility of this detector for skin dose measurements was verified in comparison with plane parallel ionization chamber and radiochromic films. The accuracy of a commercial treatment planning system (TPS) in skin dose calculations for intensity-modulated radiation therapy treatment of nasopharyngeal carcinoma was evaluated using MOSFET detectors in an anthropomorphic phantom as well as on the patients. Results show that this newly developed MOSFET detector can provide a minimal but highly reproducible intrinsic buildup of 7 mg cm{sup -2} corresponding to the requirements of personal surface dose equivalent Hp (0.07). The reproducibility of the MOSFET response, in high sensitivity mode, is found to be better than 2% at the phantom surface for the doses normally delivered to the patients. The MOSFET detector agrees well with the Attix chamber and the EBT Gafchromic registered film in terms of surface and buildup region dose measurements, even for oblique incident beams. While the dose difference between MOSFET measurements and TPS calculations is within measurement uncertainty for the depths equal to or greater than 0.5 cm, an overestimation of up to 8.5% was found for the surface dose calculations in the anthropomorphic phantom study. In vivo skin dose measurements reveal that the dose difference between the MOSFET results and the TPS calculations was on average -7.2%, ranging from -4.3% to -9.2%. The newly designed MOSFET detector encapsulated into a thin water protective film has a minimal reproducible intrinsic buildup recommended for skin dosimetry. This feature makes it very suitable for routine IMRT QA and accurate in vivo skin dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Radiation Transport Codes, HZETRN, HETC and FLUKA, Using the 1956 Webber SPE Spectrum

Protection of astronauts and instrumentation from galactic cosmic rays (GCR) and solar particle events (SPE) in the harsh environment of space is of prime importance in the design of personal shielding, spacec raft, and mission planning. Early entry of radiation constraints into the design process enables optimal shielding strategies, but demands efficient and accurate tools that can be used by design engineers in every phase of an evolving space project. The radiation transport code , HZETRN, is an efficient tool for analyzing the shielding effectiveness of materials exposed to space radiation. In this paper, HZETRN is compared to the Monte Carlo codes HETC-HEDS and FLUKA, for a shield/target configuration comprised of a 20 g/sq cm Aluminum slab in front of a 30 g/cm^2 slab of water exposed to the February 1956 SPE, as mode led by the Webber spectrum. Neutron and proton fluence spectra, as well as dose and dose equivalent values, are compared at various depths in the water target. This study shows that there are many regions where HZETRN agrees with both HETC-HEDS and FLUKA for this shield/target configuration and the SPE environment. However, there are also regions where there are appreciable differences between the three computer c odes.

Heinbockel, John H.↗

SU-D-207B-02: Early Grade Classification in Meningioma Patients Combining Radiomics and Semantics Data

Purpose: The clinical management of meningioma is guided by its grade and biologic behavior. Currently, diagnosis of tumor grade follows surgical resection and histopathologic review. Reliable techniques for pre-operative determination of tumor behavior are needed. We investigated the association between imaging features extracted from preoperative gadolinium-enhanced T1-weighted MRI and meningioma grade. Methods: We retrospectively examined the pre-operative MRI for 139 patients with de novo WHO grade I (63%) and grade II (37%) meningiomas. We investigated the predictive power of ten semantic radiologic features as determined by a neuroradiologist, fifteen radiomic features, and tumor location. Conventional (volume and diameter) imaging features were added for comparison. AUC was computed for continuous and χ{sup 2} for discrete variables. Classification was done using random forest. Performance was evaluated using cross validation (1000 iterations, 75% training and 25% validation). All p-values were adjusted for multiple testing. Results: Significant association was observed between meningioma grade and tumor location (p<0.001) and two semantic features including intra-tumoral heterogeneity (p<0.001) and overt hemorrhage (p=0.01). Conventional (AUC 0.61–0.67) and eleven radiomic (AUC 0.60–0.70) features were significant from random (p<0.05, Noether test). Median AUC values for classification of tumor grade were 0.57, 0.71, 0.72 and 0.77 respectively for conventional, radiomic, location, and semantic features after using random forest. By combining all imaging data (semantic, radiomic, and location), the median AUC was 0.81, which offers superior predicting power to that of conventional imaging descriptors for meningioma as well as radiomic features alone (p<0.05, permutation test). Conclusion: We demonstrate a strong association between radiologic features and meningioma grade. Pre-operative prediction of tumor behavior based on imaging features offers promise for guiding personalized medicine and improving patient management.

60 APPLIED LIFE SCIENCES↗

Assessments of Physiology and Cognition in Hybrid-Reality Environments (APACHE)

NASA is planning to return to the Moon in the mid-2020s as a stepping stone to Mars missions in the 2030s. Spacewalks, or extravehicular activities (EVAs), performed on the Moon and Mars will differ in a variety of ways from those that have been performed in decades past. NASA has identified multiple risks to human health and performance associated with a crewed mission to Mars, especially those associated with exploration EVAs which are expected to be a primary mission activity. Crew may be expected to conduct up to 24 hours of EVA per person per week, where the likelihood of injury and/or mental mistakes are increased compared to ground-based training or current microgravity EVAs and the consequences of which can be catastrophic. Current test environments for exploration EVA research and technology development are large, costly facilities that are limited in their availability or capabilities. Spacesuit testing in a reduced gravity environment such as NASA’s Neutral Buoyancy Laboratory, while a good representation of the crew’s physical workload during exploration EVAs, typically has small datasets and is difficult to integrate physiological sensors or other types of crew performance measures. Meanwhile, scientific field-based testing such as NASA’s Desert Research and Technology Studies offers an operationally relevant environment for exploration EVAs, particularly for cognitive workload, but is also limited by small datasets, lack of a pressurized spacesuit, and obtrusive measures. The limitations of current analogs for exploration EVAs identify a need for a new test environment that can approximate both the physical and cognitive demands associated with exploration EVAs to enable rapid, controlled, and repeatable evaluations of human health and performance risks of exploration missions. In response, the Human Physiology, Performance, Protection, and Operations Laboratory (H-3PO) at NASA Johnson Space Center has developed a hybrid reality exploration EVA analog named the Assessments of Physiology And Cognition in Hybrid-reality Environments (APACHE) to address these limitations using a combination of virtual, physical, and hybrid reality techniques. The APACHE facility resides at NASA Johnson Space Center and serves as a large “sandbox” for EVA research and simulation. At its center is a roughly 15x20ft space surrounded by a 14” tall sandbox partially filled with lunar regolith simulant to emulate the physical feeling of walking on a planetary surface and to allow for simulated geology operations. Nearby, a curved passive treadmill (Skillmill Connect, Technogym, Fairfield, NJ) and an omnidirectional treadmill (Infinadeck, Infinadeck, Rocklin, CA) are included to enable exploration of these large virtual environments while also imposing the physical demands, representative timelines, and cognitive burdens required to navigate and traverse these distances during exploration EVA. A 6DOF motion platform is used to simulate rover operations and supports various human performance evaluations and associated risks. Lastly, APACHE can support two extravehicular (EV) crewmembers working in tandem. A computer workstation is located nearby and also supports an intravehicular (IV) crewmember as part of a full mission simulation. The IV crewmember has direct video and audio communication with the EV crew in VR to provide operational and procedural support. The software used in APACHE was created by the JSC Engineering Directorate, in partnership with Buendea, powered by a custom Unreal Engine 5 (UE5.3, Epic Games) project. APACHE currently utilizes the HTC Vive Pro Eye in a wireless configuration for VR simulations. There are two virtual environments that subjects can explore within APACHE, a Lunar and Martian surface. The virtual Lunar surface was created from LIDAR data of the Lunar South Pole to create roughly 16 sq km of explorable terrain. The virtual Martian surface contains roughly 400 sq km of explorable terrain derived from Mars Reconnaissance Orbiter LIDAR data of the Jezero Crater. The immersion and related cognitive burdens of conducting a planetary EVA is simulated through a series of EVA-relevant tasks performed in the VR environment, using these high-fidelity visual representations. Additionally, APACHE includes biosensor driven informatics, such as real-time heart rate monitoring and/or derived values from model simulations, for active monitoring by the EV crew and added cognitive demand. A “Wizard of Oz” control panel enables test operators to activate contingency events such as simulated spacesuit malfunctions, loss of communications, and/or limited visibility. Embedded performance measures such as accuracy, completeness, and execution time have been developed for various exploration tasks to objectively quantify crew performance during an EVA and compare impacts to performance when different environmental stressors, both physical and cognitive, are added to or removed from the simulation. Additionally, validated cognitive and operational performance measures such as the Digit Symbol Substitution Task have been recreated and embedded in VR for direct and relatively unobtrusive measurement of motor perception. The APACHE environment currently supports multiple research studies at NASA. Examples include the CHAPEA project, a series of simulated year-long missions on Mars by a 4-person crew; and the CO2 Contingency Walk Back Study, an investigation of elevated CO2 exposure on crew performance during a contingency EVA scenario. APACHE also provides a test environment to support the development of the Crew State and Risk Model, which is a collection of individualized, mathematical models of crew physical and cognitive state; and the Personalized EVA Informatics and Decision Support system, an operational tool for flight controllers, and eventually a self-reliant Martian crew, to make biomedically-informed decisions in real-time to optimize the EVA planning and execution with respect to crew health and performance. Some technical challenges associated with developing the APACHE environment, as well as current limitations, include VR limitless natural walking with a hybrid spacesuit simulator, optimizing performance for wireless PC VR streaming while maintaining a high degree of visual fidelity, and the integration of various physiological (metabolic masks) and psychometric (eye tracking) sensors with the VR headset.

Human Performance↗