Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

Moyer, David↗

Recirculating Etalon Spectrometer

Systems, methods, and devices may provide an optical scheme that achieves simultaneous wavelength channels and maintains the resolution and luminosity of an etalon. Various embodiments may provide a method to optically recirculate the light reflected from the etalon back through the same etalon at new angles. Various embodiments create an etalon spectrometer based on angular dispersion without moving parts and without losing the light that is not initially transmitted. Various embodiments may provide a spectrally-resolved receiver and/or transmitter. Various embodiments may provide a system including a retro-reflector, a detector or transmitter array, and an etalon disposed between the retro-reflector and the detector or transmitter array, wherein the retro-reflector is configured to redirect light reflected by the etalon back to the etalon at a different angle of incidence than an original angle of incidence on the etalon of the light reflected by the etalon.

Stephen, Mark A.↗

NIAC Swarm Flyby Gravimetry Phase II Report

This NASA Innovative Advanced Concept (NIAC) grant has enabled the research and development of a method for conducting small body gravimetry from a spacecraft, using relative measurements to a set of deployed test-masses. The test-masses are tracked from a host spacecraft, which dispenses them near to the small body's surface. Thanks to this close proximity, the probes' orbits can be highly perturbed, which yields useful gravimetric measurements. The most readily achievable approach for tracking the probes is to use an optical instrument on- board the spacecraft. The probes then need only be reflective to sunlight. This implementation, called optical gravimetry (OpGrav), has the fewest requirements for the host spacecraft and probes.The results of this study indicate that OpGrav is feasible and offers meaningful improvement over existing methods. Parametric studies suggest roughly an order of magnitude improvement in accuracy or asteroid accessibility (how small an asteroid one can measure) over Earth-based Doppler-only mass estimation. This exponentially expands the number of potential near-Earth objects that one could study, which has implications for planetary defense.As a sample mission, we evaluated OpGrav as an added instrument on a main- belt asteroid tour mission. In this case, simulations show that OpGrav would increase the number of asteroid mass estimates from 3 of 9 to 7 of 9. That is, OpGrav has sufficient sensitivity to offer utility in missions for which it is not explicitly designed for.We designed and fabricated a prototype hardware implementation for this concept called the Small-body In-situ Multi-probe Mass Estimation Experiment (SIMMEE). This hardware provides a basis for many inputs into the simulations and grounds the models with physical values. The primary design driver for the hardware is a long life, on the order of five years prior to operation, and a need for high pointing accuracy to enable flybys of the smallest objects.The next steps include further hardware testing and extension of the concept to rendezvous cases. We believe that this concept offers planetary scientists a new and relevant means of better understanding small-bodies.

Atchison, Justin A.↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

The optomechanical design for the Off-plane Grating Rocket Experiment (OGRE)

The Off-plane Grating Rocket Experiment (OGRE) is a sounding rocket payload designed to obtain a high-resolution soft X-ray spectrum of Capella. OGRE’s optical system uses new technologies including state-of-the-art X-ray optics, custom arrays of reflection gratings, and an array of EM-CCDs. Many of these technologies will be tested for the first time in flight with OGRE. To achieve the high performance that these new technologies are capable of, the payload components must be properly aligned to meet high tolerances. This paper will outline OGRE’s opto-mechanical design for achieving alignment within these tolerances. Specifically, the design of the X-ray grating arrays will be discussed.

Bridget C. O’Meara↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in large transonic and supersonic wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and lightly seeded air to determine the viability and accuracy of the technique. The other reality of a wind tunnel setup is the background scattering or the glare at laser frequency, which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. Since the background glare occurs at the known frequency of the incident light and the Mie scattering peak corresponds to the Doppler shift from the bulk velocity, both were easily identified, and provided a measure of flow velocity. Preliminary results show that the Rayleigh spectrum can also be resolved, which provides a measure of temperature. It is observed that a slight drift of the laser frequency during data collection affected fitting of the model function leading to larger error. A feedback loop-based stabilization system is on development to take advantage of slight tunability of the laser via a piezo-control. Preliminary results are presented in the abstract. More extensive data from a systematic survey will be presented in the final paper.

Rayleigh scattering↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in high-speed wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and air with different particle concentration to determine the accuracy of the technique. The other reality of a wind tunnel setup is the spurious reflection and scattering of the incident laser beam by solid surfaces (flare light), which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light from a point on the laser path is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. It was observed that the present modeling approach can extract velocity and temperature with reasonable accuracy when the intensity of the Mie scattered light is less than or comparable to that of the Rayleigh scattered light; beyond that error in velocity measurement remains reasonable ±12m/s but the temperature measurement becomes progressively more inaccurate. Increasingly the flare light is found to cause a bias error in velocity. Similar trend is observed in the presence of both the flare light and the Mie scattered light. The setup has provided a set of data for the future improvement of the modeling procedure, and demonstrated that even in the case of large amount of dust particles and large flare light the present technique can provide measurement of velocity with reasonable accuracy.

Rayleigh scattering↗

Assessing the Adhesion of Nanofibrous PVDF-HFP as Passive Thermal Control Coatings for the Extraterrestrial Storage of Cryogenic Propellants

Cryogenic propellant passive thermal management techniques in space are essential complements to active thermal management methods, helping reduce absolute dependence on the latter. Particularly, materials with superior optical properties (high solar reflectance and infrared emittance) would be beneficial for passive thermal control to reject most of the incident solar radiation and enhance thermal emission from the storage tank, leading to self-cooling. We developed a nanofibrous, porous passive thermal control material by electrospinning polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) co-polymer onto an aluminum foil substrate. The material exhibits a very high solar reflectance (>99%) and infrared emittance (~86%) when characterized in the ultraviolet-visible-near infrared and mid-infrared wavelengths. This study focuses on the adhesion of the nanofibrous PVDF-HFP to the substrate. We incorporated in-lab fabricated and commercial adhesives, under normal room conditions, between the nanofibers and the aluminum foil substrate to improve their adhesion. Some samples were also exposed to space-like conditions – vacuum and thermal cycling, to investigate their effects on the strengths of adhesives. Subsequently, adhesion peel tests were conducted on all the samples to assess the peel strengths of the bonds. Peel test strengths after space environment conditioning of the adhesives were generally higher than those observed in the pristine, unaged samples. The results are discussed in this study.

Chieloka Ibekwe↗

Mapping the Ionization State of Laser-Irradiated Ar Gas Jets With Multi-Wavelength Monochromatic X-Ray Imaging

Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultra-high intensity (10{sup 19} W/cm{sup 2}, 200 fs) Ti:Sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {micro}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {micro}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry, which images in one dimension, indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {micro}m along the laser axis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Hybrid Reflective/Refractive/Diffractive Achromatic Fiber-Coupled Radiation Resistant Imaging System for Use in the Spallation Neutron Source (SNS)

A fiber-coupled imaging system for monitoring the proton beam profile on the target of the Spallation Neutron Source was developed using reflective, refractive and diffractive optics to focus an image onto a fiber optic imaging bundle. The imaging system monitors the light output from a chromium-doped aluminum oxide (Al{sub 2}0{sub 3}:Cr) scintillator on the nose of the target. Metal optics are used to relay the image to the lenses that focus the image onto the fiber. The material choices for the lenses and fiber were limited to high-purity fused silica, due to the anticipated radiation dose of 10{sup 8} R. In the first generation system (which had no diffractive elements), radiation damage to the scintillator on the nose of the target significantly broadened the normally monochromatic (694 nm) spectrum. This created the need for an achromatic design in the second generation system. This was achieved through the addition of a diffractive optic for chromatic correction. An overview of the target imaging system and its performance, with particular emphasis on the design and testing of a hybrid refractive/diffractive high-purity fused silica imaging triplet, is presented.

36 MATERIALS SCIENCE↗

An experimental apparatus for diffraction-limites soft x-ray nanofocusing

Realizing the experimental potential of high-brightness, next generation synchrotron and free-electron laser light sources requires the development of reflecting x-ray optics capable of wavefront preservation and high-resolution nano-focusing. At the Advanced Light Source (ALS) beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for diffraction-limited Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of wavefront-sensing tests with increasing accuracy and sensitivity, including scanning-slit Hartmann tests, grating-based lateral shearing interferometry, and quantitative knife-edge testing. We describe the original experimental techniques and alignment methodology that have enabled us to optimally set a bendable KB mirror to achieve a focused, FWHM spot size of 150 nm, with 1 nm (1.24 keV) photons at 3.7 mrad numerical aperture. The predictions of wavefront measurement are confirmed by the knife-edge testing.The side-profiled elliptically bent mirror used in these one-dimensional focusing experiments was originally designed for a much different glancing angle and conjugate distances. This work demonstrates that high-accuracy, at-wavelength wavefront-slope feedback can be used to optimize the pitch, roll, and mirror-bending forces in situ, using procedures that are deterministic and repeatable.

42 ENGINEERING↗

Imaging based refractometers

Refractometers for simultaneously measuring refractive index of a sample over a range or wavelengths of light include dispersive and focusing optical systems. An optical beam including the rang of wavelengths is spectrally spread along a first axis and focused along a second axis so as to be incident to an interface between the sample and a prism at a range of angles of incidence including a critical angle for at least one wavelength. In some cases, the prism can have a triangle, parallelogram, trapezoid, or other shape. In some cases, the optical beam can be reflected off of multiple interfaces between the prism and the sample. An imaging detector is situated to receive the spectrally spread and focused light from the interface and form an image corresponding to angle of incidence as a function of wavelength. One or more critical angles are indentified and corresponding refractive indices are determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stillwater Hybrid Geo-Solar Power Plant Optimization Analyses

Solar field and power plant models have been developed to predict the performance of the Stillwater geothermal / solar-thermal hybrid power plant. The models have been validated using operational data from the Stillwater plant. The validated models will be used to optimize performance of the Stillwater hybrid plant and explore next-generation hybrid plant design concepts. A preliminary effort to improve performance of the Stillwater hybrid plant using optical characterization of the solar field has been completed. The Stillwater solar field optical characterization involved measurement of mirror reflectance, mirror slope error, and receiver position error. Subsequent analyses of the optical characterization results indicate that the solar field is currently operating at approximately 90% of the manufacturer’s performance specifications. Control system and hardware modifications expected to improve solar array performance by XX% have been identified.

14 SOLAR ENERGY↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

System and method for in-process inspection within advanced manufacturing processes

A system and method can include a laser Doppler vibrometer (LDV) in optical communication with a part during manufacturing and a transducer in ultrasonic communication with the part during manufacturing. The system can also include a controller connected to both the LDV and the transducer. The controller may be configured to cause the transducer to vibrate the part during manufacturing at a predetermined frequency and the LDV may be configured to measure one or more mechanical response types of the part during manufacturing based on one or more optical characteristics of a reflected beam. The controller may further be configured to determine whether a defect is present in the part during manufacturing in response to the one or more mechanical response types of the part.

42 ENGINEERING↗