Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Track damage and erosion of insulators by ion-induced electronic processes

Track damage and the associated ejection of atoms and molecules from insulators, which occur as a result of ion-induced electronic excitation, are of interest both in their own right and because of the mechanisms through which the energy in the excited electrons is transformed into atomic motion. In this paper an overview is given of the phenomena that are observed. We show that there is a remarkable similarity between the damage profile along the ion's track in the solid and the yield of ejected atoms at the energy that corresponds to each point on the track. It is also seen that the density of extended defects (or, correspondingly, the ejected particle yield) appears to have a 'universal' form that is weakly dependent on the type of material. In the model presented this is a consequence of the inner-shell ionization of light elements in the solid by the incident ion; the resulting Auger decay produces an intense ionization spike that locally triggers the track formation/erosion process. This model allows the estimation of erosion yields/damage profiles for different ions and materials.

Tombrello, T. A.↗

TH-B-204-01: Real-Time Tracking with Implanted Markers

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

A Unified Approach to Motion Control of Motion Robots

This paper presents a simple on-line approach for motion control of mobile robots made up of a manipulator arm mounted on a mobile base. The proposed approach is equally applicable to nonholonomic mobile robots, such as rover-mounted manipulators and to holonomic mobile robots such as tracked robots or compound manipulators. The computational efficiency of the proposed control scheme makes it particularly suitable for real-time implementation.

motion control↗

The stellar and solar tracking system of the Geneva Observatory gondola

Sun and star trackers have been added to the latest version of the Geneva Observatory gondola. They perform an image motion compensation with an accuracy of plus or minus 1 minute of arc. The structure is held in the vertical position by gravity; the azimuth is controlled by a torque motor in the suspension bearing using solar or geomagnetic references. The image motion compensation is performed by a flat mirror, located in front of the telescope, controlled by pitch and yaw servo-loops. Offset pointing is possible within the solar disc and in a 3 degree by 3 degree stellar field. A T.V. camera facilitates the star identification and acquisition.

Huguenin, D.↗

The Severe Weather Outbreak of 10 November 2002: Lightning and Radar Analysis of Storms in the Deep South

On the afternoon and evening of 10 November 2002, the Midwest and Deep South were struck by a major outbreak of severe storms that produced some 80 tornadoes. In terms of number of tornadoes, this was the largest outbreak in the United States since November 1992. Some 32 of the tornadoes occurred in Tennessee, Mississippi, Alabama and Georgia, including several long-track killers. We use the North Alabama Lightning Mapping Array (LMA) and other data sources to perform a comprehensive analysis of the structure and evolution of the outbreak. Most of the Southern tornadoes occurred in isolated, fast-moving supercell storms that formed in warm, moist air ahead of a major cold front. Storms tended to form in lines parallel to storm cell motion, resulting in many communities being hit multiple times by severe storms that evening. Supercells in Tennessee produced numerous strong tornadoes with short to medium-length track paths, while the supercells further south produced several very long-track tornadoes. Radar data indicate that the Tennessee storms tended to split frequently, apparently limiting their ability to sustain long-lived tornadoes, while storms further south split at most one time. The differences between these storms appear to be related to the presence of stronger jetstream winds in Tennessee relative to those present in Mississippi, Alabama and Georgia. LMA-derived flash rates associated with most of the supercell storm cores were about 1-2 flashes per second. Rapid increases in lightning rates (or "jumps") occurred prior to tornado touchdown in many instances. Lightning "holes" (lightning-free regions associated with the echo-free vault) occurred in two of the Tennessee supercells. The complexity of the relationship between lightning and storm severity is revealed by the behavior of one Alabama supercell, which produced a peak flash rate of nearly 14 flashes per second, well after the end of its long-track tornado, while interacting and ultimately merging with a daughter supercell on its southwest flank. Close examination of this powerful storm indicates that its prodigious flash rate was the result of strong flash activity over an unusually large area, rather than a concentrated core of extremely high flash rate activity.

Buechler, D. E.↗

Flexcam Image Capture Viewing and Spot Tracking

Flexcam software was designed to allow continuous monitoring of the mechanical deformation of the telescope structure at Palomar Observatory. Flexcam allows the user to watch the motion of a star with a low-cost astronomical camera, to measure the motion of the star on the image plane, and to feed this data back into the telescope s control system. This automatic interaction between the camera and a user interface facilitates integration and testing. Flexcam is a CCD image capture and analysis tool for the ST-402 camera from Santa Barbara Instruments Group (SBIG). This program will automatically take a dark exposure and then continuously display corrected images. The image size, bit depth, magnification, exposure time, resolution, and filter are always displayed on the title bar. Flexcam locates the brightest pixel and then computes the centroid position of the pixels falling in a box around that pixel. This tool continuously writes the centroid position to a network file that can be used by other instruments.

Rao, Shanti↗

Cumulative Lung Dose for Several Motion Management Strategies as a Function of Pretreatment Patient Parameters

Purpose: To evaluate patient parameters that may predict for relative differences in cumulative four-dimensional (4D) lung dose among several motion management strategies. Methods and Materials: Deformable image registration and dose accumulation were used to generate 4D treatment plans for 18 patients with 4D computed tomography scans. Three plans were generated to simulate breath hold at normal inspiration, target tracking with the beam aperture, and mid-ventilation aperture (control of the target at the mean daily position and application of an iteratively computed margin to compensate for respiration). The relative reduction in mean lung dose (MLD) between breath hold and mid-ventilation aperture ({delta}MLD{sub BH}) and between target tracking and mid-ventilation aperture ({delta}MLD{sub TT}) was calculated. Associations between these two variables and parameters of the lesion (excursion, size, location, and deformation) and dose distribution (local dose gradient near the target) were also calculated. Results: The largest absolute and percentage differences in MLD were 1.0 Gy and 21.5% between breath hold and mid-ventilation aperture. {delta}MLD{sub BH} was significantly associated (p < 0.05) with tumor excursion. The {delta}MLD{sub TT} was significantly associated with excursion, deformation, and local dose gradient. A linear model was constructed to represent {delta}MLD vs. excursion. For each 5 mm of excursion, target tracking reduced the MLD by 4% compared with the results of a mid-ventilation aperture plan. For breath hold, the reduction was 5% per 5 mm of excursion. Conclusions: The relative difference in MLD among different motion management strategies varied with patient and tumor characteristics for a given dosimetric target coverage. Tumor excursion is useful to aid in stratifying patients according to appropriate motion management strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT

In coronary calcium scoring, motion artifacts affecting calcified plaques are commonly characterized using descriptive terms, which incorporate an element of subjectivity in their interpretations. Quantitative indices may improve the objective characterization of these motion artifacts. In this paper, an automated method for generating 12 quantitative indices, i.e., features that characterize the motion artifacts affecting calcified plaques, is presented. This method consists of using the rapid phase-correlated region-of-interest (ROI) tracking algorithm for reconstructing ROI images of calcified plaques automatically from the projection data obtained during a cardiac scan, and applying methods for extracting features from these images. The 12 features include two dynamic, six morphological, and four intensity-based features. The two dynamic features are three-dimensional (3D) velocity and 3D acceleration. The six morphological features include edge-based volume, threshold-based volume, sphericity, irregularity, average margin gradient, and variance of margin gradient. The four intensity-based features are maximum intensity, mean intensity, minimum intensity, and standard deviation of intensity. The 12 features were extracted from 54 reconstructed sets of simulated four-dimensional images from the dynamic NCAT phantom involving six calcified plaques under nine heart rate/multi-sector gating combinations. In order to determine how well the 12 features correlated with a plaque motion index, which was derived from the trajectory of the plaque, partial correlation coefficients adjusted for heart rate, number of gated sectors, and mean feature values of the six plaques were calculated for all 12 features. Features exhibiting stronger correlations (|r| set-membership sign [0.60,1.00]) with the motion index were 3D velocity, maximum intensity, and standard deviation of intensity. Features demonstrating stronger correlations (|r| set-membership sign [0.60,1.00]) with other features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided Radiotherapy

The ExacTrac X-Ray 6D image-guided radiotherapy (IGRT) system will be described and its performance evaluated. The system is mainly an integration of 2 subsystems: (1) an infrared (IR)-based optical positioning system (ExacTrac) and (2) a radiographic kV x-ray imaging system (X-Ray 6D). The infrared system consists of 2 IR cameras, which are used to monitor reflective body markers placed on the patient's skin to assist in patient initial setup, and an IR reflective reference star, which is attached to the treatment couch and can assist in couch movement with spatial resolution to better than 0.3 mm. The radiographic kV devices consist of 2 oblique x-ray imagers to obtain high-quality radiographs for patient position verification and adjustment. The position verification is made by fusing the radiographs with the simulation CT images using either 3 degree-of-freedom (3D) or 6 degree-of-freedom (6D) fusion algorithms. The position adjustment is performed using the infrared system according to the verification results. The reliability of the fusion algorithm will be described based on phantom and patient studies. The results indicated that the 6D fusion method is better compared to the 3D method if there are rotational deviations between the simulation and setup positions. Recently, the system has been augmented with the capabilities for image-guided positioning of targets in motion due to respiration and for gated treatment of those targets. The infrared markers provide a respiratory signal for tracking and gating of the treatment beam, with the x-ray system providing periodic confirmation of patient position relative to the gating window throughout the duration of the gated delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing vortex tangle properties in steady-state He II counterflow using particle tracking velocimetry

Historically, there has been little faith in particle tracking velocimetry (PTV) as a tool to make quantitative measurements of thermal counterflow in He II, since tracer particle motion is complicated by influences from the normal fluid, superfluid, and quantized vortex lines, or a combination thereof. Recently, we introduced a scheme for differentiating particles trapped on vortices (G1) from particles entrained by the normal fluid (G2). In this paper, we apply this scheme to demonstrate the utility of PTV for quantitative measurements of vortex dynamics in He II counterflow.We estimate Ι, the mean vortex line spacing, using G2 velocity data, and c 2 , a parameter related to the mean curvature radius of vortices and energy dissipation in quantum turbulence, using G1 velocity data. We find that both estimations show good agreement with existing measurements that were obtained using traditional experimental methods. This is of particular consequence since these parameters likely vary in space, and PTV offers the advantage of spatial resolution. Furthermore, we also show a direct link between power-law tails in transverse particle velocity probability density functions (PDFs) and reconnection of vortex lines on which G1 particles are trapped.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-61: Monitoring Tumor Motion in Real-Time with EPID Imaging During Cervical Cancer Treatment

Purpose: Traditional external beam radiotherapy for cervical cancer requires setup by external skin marks. In order to improve treatment accuracy and reduce planning margin for more conformal therapy, it is essential to monitor tumor positions interfractionally and intrafractionally. We demonstrate feasibility of monitoring cervical tumor motion online using EPID imaging from Beam’s Eye View. Methods: Prior to treatment, 1∼2 cylindrical radio opaque markers were implanted into inferior aspect of cervix tumor. During external beam treatments on a Varian 2100C by 4-field 3D plans, treatment beam images were acquired continuously by an EPID. A Matlab program was developed to locate internal markers on MV images. Based on 2D marker positions obtained from different treatment fields, their 3D positions were estimated for every treatment fraction. Results: There were 398 images acquired during different treatment fractions of three cervical cancer patients. Markers were successfully located on every frame of image at an analysis speed of about 1 second per frame. Intrafraction motions were evaluated by comparing marker positions relative to the position on the first frame of image. The maximum intrafraction motion of the markers was 1.6 mm. Interfraction motions were evaluated by comparing 3D marker positions at different treatment fractions. The maximum interfraction motion was up to 10 mm. Careful comparison found that this is due to patient positioning since the bony structures shifted with the markers. Conclusion: This method provides a cost-free and simple solution for online tumor tracking for cervical cancer treatment since it is feasible to acquire and export EPID images with fast analysis in real time. This method does not need any extra equipment or deliver extra dose to patients. The online tumor motion information will be very useful to reduce planning margins and improve treatment accuracy, which is particularly important for SBRT treatment with long delivery time.

60 APPLIED LIFE SCIENCES↗

Deliberate Motion Analytics Fused Radar and Video Test Results Deployed Beyond the Perimeter Fence in a High Noise Environment

Security systems that protect the nation’s critical facilities must be capable of detecting physical intrusions in all weather conditions. Intrusion detection sensors in a perimeter with a high nuisance alarm rate (NAR) significantly undermine detection performance and degrade security system effectiveness. This research demonstrated a fused sensor system that can differentiate foliage and weather-induced nuisance alarms from those caused by intruders, providing reliable detection within a two-fence perimeter or beyond the fence. A key element of this work is the creation and application of a “deliberate motion algorithm” that fuses alarm data from radar and video analytics to create video motion detection fused radar system. The two-layer architecture of the algorithm uses machine learning, multi-hypothesis tracking, and Dynamic Bayes Nets to differentiate intruder alarms from weather induced alarms.

47 OTHER INSTRUMENTATION↗

Twelfth Annual Conference on Manual Control

Main topics discussed cover multi-task decision making, attention allocation and workload measurement, displays and controls, nonvisual displays, tracking and other psychomotor tasks, automobile driving, handling qualities and pilot ratings, remote manipulation, system identification, control models, and motion and visual cues. Sixty-five papers are included with presentations on results of analytical studies to develop and evaluate human operator models for a range of control task, vehicle dynamics and display situations; results of tests of physiological control systems and applications to medical problems; and on results of simulator and flight tests to determine display, control and dynamics effects on operator performance and workload for aircraft, automobile, and remote control systems.

Wempe, T. E.↗

Recent advances in the development and transfer of machine vision technologies for space

Recent work concerned with real-time machine vision is briefly reviewed. This work includes methodologies and techniques for optimal illumination, shape-from-shading of general (non-Lambertian) 3D surfaces, laser vision devices and technology, high level vision, sensor fusion, real-time computing, artificial neural network design and use, and motion estimation. Two new methods that are currently being developed for object recognition in clutter and for 3D attitude tracking based on line correspondence are discussed.

Defigueiredo, Rui J. P.↗

Application of precise altimetry to the study of precise leveling of the sea surface, the Earth's gravity field, and the rotation of the Earth

Our program includes five research items: (1) determination of a precision geoid and gravity anomaly field; (2) precise leveling and detection of tidal changes of the sea surface and study of the role of the tide in the global energy exchange; (3) oceanic effect on the Earth's rotation and polar motion; (4) geological and geophysical interpretation of the altimetry gravity field; and (5) evaluation of the effectiveness of local tracking of TOPEX/POSEIDON by use of a laser tracker.

Segawa, J.↗

Topographic mapping using radar interferometry - Processing techniques

In the summer of 1991 the NASA DC-8 airborne synthetic aperture radar (SAR) system acquired data with the radar configured in a C-band across-track interferometer mode. The data were processed to generate rectified topographic maps. A new processing scheme was developed featuring motion compensation, absolute phase retrieval, and three-dimensional 1ocation. The new processor has been tested using data which were acquired with extreme aircraft motion so that performance could be evaluated under adverse conditions. The topographic maps generated by the radar were compared to Digital Elevation Models (DEM's) derived using conventional optical stereo techniques. In one region we measured rms elevation deviations which were less than the specified DEM accuracy, and in the region covered by the more accurate DEM we found errors varying from 2.2 m rms in relatively flat terrain up to 5.0 m in mountainous areas. The rms difference between radar and DEM elevations over the 6.5 km by 22 km area covered by the more accurate DEM was 3.6 m.

Madsen, Soren N.↗

Axisymmetric Flow Properties for Magnetic Elements of Differing Strength

Aspects of the structure and dynamics of the flows in the Sun's surface shear layer remain uncertain and yet are critically important for understanding the observed magnetic behavior. In our previous studies of the axisymmetric transport of magnetic elements we found systematic changes in both the differential rotation and the meridional flow over the course of Solar Cycle 23. Here we examine how those flows depend upon the strength (and presumably anchoring depth) of the magnetic elements. Line of sight magnetograms obtained by the HMI instrument aboard SDO over the course of Carrington Rotation 2097 were mapped to heliographic coordinates and averaged over 12 minutes to remove the 5-min oscillations. Data masks were constructed based on the field strength of each mapped pixel to isolate magnetic elements of differing field strength. We used Local Correlation Tracking of the unmasked data (separated in time by 1- to 8-hours) to determine the longitudinal and latitudinal motions of the magnetic elements. We then calculated average flow velocities as functions of latitude and longitude from the central meridian for approx 600 image pairs over the 27-day rotation. Variations with longitude indicate and characterize systematic errors in the flow measurements associated with changes in the signal from disk center to limb. Removing these systematic errors reveals changes in the axisymmetric flow properties that reflect changes in flow properties with depth in the surface shear layer.

Rightmire-Upton, Lisa↗

Temporal Interpolation of Geostationary Satellite Imagery with Task Specific Optical Flow

Applications of satellite data in areas such as weather tracking and modeling, ecosystem monitoring, wildfire detection, and land-cover change are heavily dependent on the trade-offs to spatial, spectral and temporal resolutions of observations. In weather tracking, high-frequency temporal observations are critical and used to improve forecasts, study severe events, and extract atmospheric motion, among others. However, while the current generation of geostationary satellites have hemispheric coverage at 10-15 minute intervals, higher temporal frequency observations are ideal for studying mesoscale severe weather events. In this work, we apply a task specific optical flow approach to temporal up-sampling using deep convolutional neural networks. We apply this technique to 16-bands of GOES-R/Advanced Baseline Imager mesoscale dataset to temporally enhance full disk hemispheric snapshots of different spatial resolutions from 15 minutes to 1 minute. Experiments show the effectiveness of task specific optical flow and multi-scale blocks for interpolating high-frequency severe weather events relative to bilinear and global optical flow baselines. Lastly, we demonstrate strong performance in capturing variability during convective precipitation events.

Optical flow, temporal interpolation, geostationar↗