Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MarCo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

γIn-beam angular distribution and linear polarization measurements with GRETINA using a simple energy-ordering approach

Angular distribution and linear polarization measurements are powerful tools for inferring the spins and parities of nuclear levels. In this work, the performance of the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter was characterized in a fusion-evaporation reaction experiment using a simple energy-ordering approach for the interaction points assigned in the signal decomposition process. A variety of multipolarities and characters for γ-ray transitions in the reaction products 25 Mg, 25 Na, and 22 Ne, formed from fusion-evaporation of an 18 O beam on a 9 Be target, were examined. The experimental angular distributions and linear polarization asymmetries were consistent with predictions using the theoretical formalism accounting for the Lorentz boost.

Angular distribution↗

A prototype hybrid mode cavity for heterodyne axion detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

Li, Zenghai [SLAC]↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

International fuel performance study of fresh fuel experiments for PCMI effects during RIA experiments

This paper presents the results of High-burnup Experiments for Reactivity-initiated Accident (HERA) Modeling & Simulation (M&S) exercise. The HERA project under the Nuclear Energy Agency (NEA) Second Framework for Irradiation Experiments (FIDES-II) program is focused on studying Light Water Reactor (LWR) fuel behavior during Reactivity-Initiated Accident (RIA) conditions. The Part I M&S cases are based on a series of tests in the Transient Reactor Test (TREAT) facility in the United States and the Nuclear Safety Research Reactor (NSRR) in Japan. The purpose of this work is to evaluate the test design to accomplish its goals in establishing clearer understanding of the effects of power pulse width during RIA conditions. Further, the blind predictions using various computational tools have been performed and compared amongst to interpret the behaviors of high burnup fuels during RIA. While many international participants evaluate the thermal–mechanical behavior of fuel rod under different conditions, a considerable scatter of outputs comes out for the cases due to the disparity between codes in predicting mechanical behaviors. In general, however, the results of thermal–mechanical analysis elaborate that nominal design conditions the shorter pulse width tests in NSRR should cause cladding failures while the TREAT tests appear to have more split prediction of failure or not. Furthermore, the sensitivity analysis varying key testing parameters reveals the considerable effect of power pulse width and total energy deposition on prediction of fuel rod failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resonances in QCD

We report on the EMMI Rapid Reaction Task Force meeting 'Resonances in QCD', which took place at GSI October 12-14, 2015 (Fig.~1). A group of 26 people met to discuss the physics of resonances in QCD. The aim of the meeting was defined by the following three key questions; what is needed to understand the physics of resonances in QCD?; where does QCD lead us to expect resonances with exotic quantum numbers?; and what experimental efforts are required to arrive at a coherent picture? For light mesons and baryons only those with up, down and strange quark content were considered. For heavy-light and heavy-heavy meson systems, those with charm quarks were the focus.This document summarizes the discussions by the participants, which in turn led to the coherent conclusions we present here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineering challenges for detectors at the ILC

Over the last years two proposals for experiments at the ILC have been developed, ILD and SID. Extensive R&D has been carried out around the world to develop the needed technologies. Furthermore a first round of engineering studies was made as part of the ILC TDR to understand the integration of these different sub-systems into coherent and integrated detector concepts. Among the key challenges for the sub detectors are the extreme low mass/low power requirements or the extreme channel densities needed in particle flow based detectors. Throughout these studies special care was taken to ensure that the engineering models and the simulation models, used in studies of the physics capabilities of the detectors, stay synchronized. In the near future, the models will need to be evolved to take the special requirements of the potential ILC site in Japan into account. Furthermore, the state of the integration of the detectors, and the future directions, will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aromaticity and degree of aromatic condensation of char

The aromatic carbon structure is a defining property of chars and is often expressed with the help of two concepts: (i) aromaticity and (ii) degree of aromatic condensation. The varying extent of these two features is assumed to largely determine the relatively high persistence of charred material in the environment and is thus of interest for, e.g., biochar characterization or carbon cycle studies. Consequently, a variety of methods has been used to assess the aromatic structure of chars, which has led to interesting insights but has complicated the comparison of data acquired with different methods. We therefore used a suite of seven methods (elemental analysis, MIR spectroscopy, NEXAFS spectroscopy, 13 C NMR spectroscopy, BPCA analysis, lipid analysis and helium pycnometry) and compared 13 measurements from them using a diverse sample set of 38 laboratory chars. Here, our results demonstrate that most of the measurements could be categorized either into those which assess aromaticity or those which assess the degree of aromatic condensation. A variety of measurements, including relatively inexpensive and simple ones, reproducibly captured the two aromatic features in question, and data from different methods could therefore be compared. Moreover, general patterns between the two aromatic features and the pyrolysis conditions were revealed, supporting reconstruction of the highest heat treatment temperature (HTT) of char.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pore-scale multiphase flow modeling and imaging of CO 2 exsolution in Sandstone

This study utilizes synchrotron X-ray micro-tomography and pore scale modeling to investigate the process of gas exsolution and how it affects non-wetting phase relative permeability. Exsolved gas distributions are measured on Domengine and Boise sandstone samples using synchrotron X-ray micro-tomography. Observed gas phase distributions are compared to a new model that simulates the growth and distribution of exsolved gas phase at the pore-scale. Water relative permeability curves are calculated using a Stokes flow simulator with modeled and observed gas distributions, under various conditions, such as rock geometry, and pressure depletion rates. By comparing the actual bubble distributions with modeled distributions, we conclude that exsolved gas is more likely to form and accumulate at locations with higher water velocities. This suggests that convective delivery of CO2 to the gas bubble is a primary mechanism for bubble growth, as compared to diffusive transport through the aqueous phase. For carbonated brine flowing up a fault at half a meter per day, with 5% exsolved gas, the water relative permeability is estimated to be 0.6~0.8 for various sandstones. The reduction of water mobility reduces upward brine migration when even a small amount of exsolution occurs.

58 GEOSCIENCES↗

In-situ 4D visualization and analysis of temperature-driven creep in an oil shale propped fracture

Here, the proppant embedment due to creep in shales is a known issue affecting the useable lifetime of wells in unconventional oil and gas recovery. One of the factors influencing creep is the presence of organics, whose properties can be very sensitive to temperature. In this work we investigated for the first time the role of temperature-induced creep increase in proppant embedment in an organics-rich Green River oil shale sample via in-situ synchrotron X-ray micro-computed tomography. We observed that temperatures as low as 75 °C already induce fast creep, with a fracture aperture closing rate of 13 μm/h and a loss of fracture conductivity rate of 8.7%/h, due only to proppant embedment, in the measured interval at the first heating stage. Local displacement data analysis provided evidence for markedly plastic deformation around the proppant-shale contacts, in contrast with the brittle proppant embedment observed on more cemented and less organics-rich shales at room temperature. The results highlight how the problem of temperature-dependent mechanical behavior might be more important than previously thought, in shales with a high content in organics, and that in-situ micro-imaging techniques can play a key role in understanding the underlying mechanisms, contributing to solve creep-related problems associated with hydraulic fracturing in complex scenarios.

02 PETROLEUM↗

Deep Cryogenic Low Power 24 Bits Analog to Digital Converter with Active Reverse Cryostat

LBNL is developing an innovative data acquisition module for superconductive magnets where the front-end electronics and digitizer resides inside the cryostat. This electronic package allows conventional electronic technologies such as enhanced metal–oxide–semiconductor to work inside cryostats at temperatures as low as 4.2 K. This is achieved by careful management of heat inside the module that keeps the electronic envelop at approximately 85 K. This approach avoids all the difficulties that arise from changes in carrier mobility that occur in semiconductors at deep cryogenic temperatures. There are several advantages in utilizing this system. A significant reduction in electrical noise from signals captured inside the cryostat occurs due to the low temperature that the electronics is immersed in, reducing the thermal noise. The shorter distance that signals are transmitted before digitalization reduces pickup and cross-talk between channels. This improved performance in signal-to-noise rate by itself is a significant advantage. Another important advantage is the simplification of the feedthrough interface on the cryostat head. Data coming out of the cryostat is digital and serial, dramatically reducing the number of lines going through the cryostat feedthrough interface. It is important to notice that all lines coming out of the cryostat are digital and low voltage, reducing the possibility of electric breakdown inside the cryostat. This paper will explain in details the architecture and inner workings of this data acquisition system. It will also provide the performance of the analog to digital converter when the system is immersed in liquid helium, and in liquid nitrogen. Parameters such as power dissipation, integral non-linearity, effective number of bits, signal-to-noise and distortion, will be presented for both temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗