Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

Radio astronomy

The following subject areas are covered: (1) scientific opportunities (millimeter and sub-millimeter wavelength astronomy; meter to hectometer astronomy; the Sun, stars, pulsars, interstellar masers, and extrasolar planets; the planets, asteroids, and comets; radio galaxies, quasars, and cosmology; and challenges for radio astronomy in the 1990's); (2) recommendations for new facilities (the millimeter arrays, medium scale instruments, and small-scale projects); (3) continuing activities and maintenance, upgrading of telescopes and instrumentation; (4) long range programs and technology development; and (5) social, political, and organizational considerations.

Kellermann, Kenneth I.↗

Spacecraft Doppler tracking with a VLBI antenna

Preliminary results are reported from Doppler-shift measurements to the Voyager-2 spacecraft at a distance of 26 AU, obtained using the 32-m VLBI antenna at Medicina (Italy) during July and August 1988. The apparatus comprises the el-az antenna, an S-X-band receiver, a hydrogen maser to generate the reference signal, a Mark III VLBI terminal, and a digital tone extractor capable of isolating a tone of known frequency from a noisy signal and giving its phase and amplitude. A signal transmitted in S-band from the NASA Deep Space Network (DSN) station in Australia and retransmitted coherently in X-band by Voyager, was received 7 h 6 min later at Medicina and at the DSN station in Madrid. Sample data are presented graphically and shown to be of generally high quality; further in-depth analysis is under way.

Comoretto, G.↗

Possible second harmonic gyroemission at Uranus

During the inbound trajectory toward Uranus, the Planetary Radio Astronomy Instrument on board the Voyager 2 spacecraft observed narrow-band smooth (n-smooth) emission at frequencies centered near 60 kHz. By assuming models of the plasma density for the dayside magnetosphere of Uranus and by using cold plasma theory together with stringent observational constraints, ray-tracing calculations were performed to determine the source location and mode of the n-smooth emission. Ray-tracing calculations suggest that the n-smooth emission with sources near the magnetic equator may be fundamental X mode for certain conditions or second harmonic gyroemission. If the emission is second harmonic gyroemission, the fundamental emission at 30 kHz is expected but apparently not observed. These findings are discussed in the context of the most recent developments in the theory of the cyclotron maser instability.

Menietti, J. D.↗

First interferometric observations of solar microwave millisecond spike bursts

Observations, with one-dimensional spatial resolution, of solar microwave millisecond spikes at 2.8 GHz are reported. The observations were made with the Owens Valley frequency-agile interferometer with 20 ms time resolution. It is found that the spikes occur at a position different from that of the underlying gyrosynchrotron radio burst source. All of the spikes during the rising part of the burst come from the same one-dimensional location to within + or - 1 arcsec, despite the fact that rapid evolution in the sense and degree of circular polarization was observed. The one-dimensional position of the spikes is consistent with a location over a large sunspot, suggesting that the emission occurs in a region of strong, converging magnetic field. The observations support the suggestion that the spikes are due to the electron-cyclotron maser mechanism.

Gary, Dale E.↗

Some phenomena in space plasmas attributed to wave-particle interactions

Three different wave-particle interaction processes are investigated: (1) the pickup of newborn ions by the solar wind, (2) the cyclotron maser mechanism, and (3) a special wave-particle interaction process which generalizes the conventional concept of the wave-particle interaction process. It is demonstrated on the basis of these three cases that wave-particle interactions can play an indispendable role in certain physical phenomena associated with space plasmas, whose nature is such as to preclude conventional hydrodynamic characterization. Wave-particle interactions can also generate such anomalous transport processes as spatial diffusion, anomalous heating, absorptions of radiation, etc., which also have significant consequence in space plasmas.

Wu, Ching-Sheng↗

Millimeter- and submillimeter-wave spectrum of highly excited states of water

To facilitate studies of water in the interstellar medium and late-type stars, the frequencies of 30 new millimeter- and submillimeter-wave transitions of H2O-16 have been measured, which lie between 100 GHz and 600 GHz. This represents almost a doubling of the number of water lines that have been observed in the laboratory in this spectral region at high resolution. All of the newly observed lines are highly excited, lying between 2400 and 4200/cm above the ground level. Some of these have large excitation energies because of their high rotational states and others because they lie in excited vibrational states. These lines are potentially of substantial astrophysical significance because they are related to the study of interstellar masers and because their high excitation eliminates the atmospheric self-absorption associated with the more well-known water lines.

Pearson, J. C.↗

Flare stars at radio wavelengths

The radio emission from dMe flare stars is discussed using Very Large Array and Arecibo observations as examples. Active flare stars emit weak, unpolarized, quiescent radio radiation that may be always present. Although thermal bremsstrahlung and/or thermal gyroresonance radiation account for the slowly-varying, quiescent radio radiation of solar active regions, these processes cannot account for the long-wavelength quiescent radiation observed from nearby dMe flare stars. It has been attributed to nonthermal gyrosynchrotron radiation, but some as yet unexplained mechanism must be continually producing the energetic electrons. Long duration, narrow-band radiation is also emitted from some nearby dMe stars at 20 cm wavelength. Such radiation may be attributed to coherent plasma radiation or to coherent electron-cyclotron masers. Impulsive stellar flares exhibit rapid variations that require radio sources that are smaller than the star in size, and high brightness temperatures greater than 10(exp 15) K that are also explained by coherent radiation processes. Quasi-periodic temporal fluctuations suggest pulsations during some radio flares. Evidence for frequency structure and positive or negative frequency drifts during radio flares from dMe stars is also presented.

Lang, Kenneth R.↗

Cooled Low-Noise HEMT Microwave Amplifiers

Prototype cooled low-noise microwave amplifiers based on high-electron-mobility transistors (HEMT's) considered as replacements for cooled ruby masers used as low-noise receiver-front-end amplifiers in communications, radio science, radar systems, radio astronomy, and telemetry. HEMT amplifier operates at 12 K, requires less cooling power and operates at lower cost with simpler, more-reliable cooling system.

Bautista, J. Javier↗

Radar interferometric studies of comets

Our objectives are to use radio interferometry to study composition, velocity distribution, maser excitation, and plasma interactions of cometary gas. Two new cometary chemistry programs were started with radio interferometers: (1) the VLA used to search for HC3N emission from Comet Brorsen-Metcalf at 3.3 cm wavelength; and (2) the BIMA millimeter array used to observe Comet Austin in HCN.

Snyder, Lewis E.↗

Interstellar Scattering Towards the Galactic Center as Probed by OH/IR Stars

Angular broadening measurements are reported of 20 OH/IR stars near the galactic center. This class of sources is known to have bright, intrinsically compact (less than or equal to 20 mas) maser components within their circumstellar shells. VLBA antennas and the VLA were used to perform a MKII spectral line VLBI experiment. The rapid drop in correlated flux with increasing baseline, especially for sources closest to the galactic center, is attributed to interstellar scattering. Angular diameters were measured for 13 of our sources. Lower limits were obtained for the remaining seven. With the data, together with additional data taken from the literature, the distribution was determined of interstellar scattering toward the galactic center. A region was found of pronounced scattering nearly centered on SgrA*. Two interpretations are considered for the enhanced scattering. One hypothesis is that the scattering is due to a clump of enhanced turbulence, such as those that lie along lines of sight to other known objects, that has no physical relationship to the galactic center. The other model considers the location of the enhanced scattering to arise in the galactic center itself. The physical implications of the models yield information on the nature of interstellar scattering.

Vanlangevelde, Huib Jan↗

Continuum radiation in planetary magnetospheres

With the completion of the Voyager tour of the outer planets, radio and plasma wave instruments have executed the first survey of the wave spectra of Earth, Jupiter, Saturn, Uranus, and Neptune. One of the most notable conclusions of this survey is that there is a great deal of qualitative similarity in both the plasma wave and radio wave spectra from one magnetosphere to the next. In particular, in spite of detailed differences, most of the radio emissions at each of the planets have been tentatively classified into two primary categories. First, the most intense emissions are generally associated with the cyclotron maser instability. Second, a class of weaker emissions can be found at each of the magnetospheres which appears to be the result of conversion from intense electrostatic emissions at the upper hybrid resonance frequency into (primarily) ordinary mode radio emission. It is this second category, often referred to as nonthermal continuum radiation, which we will discuss in this review. We review the characteristics of the continuum spectrum at each of the planets, discuss the source region and direct observations of the generation of the emissions where available, and briefly describe the theories for the generation of the emissions. Over the past few years evidence has increased that the linear mode conversion of electrostatic waves into the ordinary mode can account for at least some of the continuum radiation observed. There is no definitive evidence which precludes the possibility that a nonlinear mechanism may also be important.

Kurth, W. S.↗

Optimizing the G/T ratio of the DSS-13 34-meter beam-waveguide antenna

Calculations using Physical Optics computer software were done to optimize the gain-to-noise-temperature (G/T) ratio of Deep Space Station (DSS)-13, the Deep Space Network's (DSN's) 34-m beam-waveguide antenna, at X-band for operation with the ultra-low-noise amplifier maser system. A better G/T value was obtained by using a 24.2-dB far-field-gain smooth-wall dual-mode horn than by using the standard X-band 22.5-dB-gain corrugated horn.

Esquivel, M. S.↗

A compact 2.5-Kelvin closed-cycle refrigerator

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch filled-cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a nontilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 milliwatts of cooling at 2.5 K to 3 watts at 4.3 K. The performance of the unit is not significantly affected by operation in any physical orientation.

Britcliffe, Mike↗

Relativistic, perpendicular shocks in electron-positron plasmas

One-dimensional particle-in-cell plasma simulations are used to examine the mechanical structure and thermalization properties of collisionless relativistic shock waves in electron-positron plasmas. Shocks propagating perpendicularly to the magnetic field direction are considered. It is shown that these shock waves exist, and that they are completely parameterized by the ratio of the upstream Poynting flux to the upstream kinetic energy flux. The way in which the Rankine-Hugoniot shock jump conditions are modified by the presence of wave fluctuations is shown, and they are used to provide a macroscopic description of these collisionless shock flows. The results of a 2D simulation that demonstrates the generality of these results beyond the assumption of the 1D case are discussed. It is suggested that the thermalization mechanism is the formation of a synchrotron maser by the coherently reflected particles in the shock front. Because the downstream medium is thermalized, it is argued that perpendicular shocks in pure electron-positron plasmas are not candidates as nonthermal particle accelerators.

Gallant, Yves A.↗

The nature of dust around the post-asymptotic giant branch objects HD 161796 and HD 179821

Ground-based 7.4-24-micron spectra of two post-AGB objects, HD 161796 and HD 179821, are reported, and they are compared to those of other preplanetary nebulae. HD 161796 and HD 17982 show emission features at 10-12 microns and at 10 microns, and they exhibit a very rapid increase in flux between 13 and 15.5 microns. In view of the O-rich photosphere of HD 161796 and the presence of OH maser emission around all three objects, these features are ascribed to various oxides. The observed spectral features are quite different from the canonical silicate features observed in most O-rich giants. It is argued that HD 161796 and the bipolar nebulae Roberts 22 and NGC 6302 have all undergone the third dredge-up, with most of the dredged-up carbon having been converted to nitrogen by envelope-burning. It is concluded that carbon-rich grain material, produced during the interval between the end of the third dredge-up and the moment when envelope burning finally reduced the C/O ratio below unity again, could be responsible for the UIR bands now being excited in Roberts 22 and NGC 6302.

Justtanont, K.↗

Helium compressors for closed-cycle, 4.5-Kelvin refrigerators

An improved helium compressor for traveling-wave maser and closed-cycle refrigerator systems was developed and is currently being supplied to the DSN. This new 5-hp compressor package is designed to replace the current 3-hp DSN compressors. The new compressor package was designed to retrofit into the existing 3-hp compressor frame and reuse many of the same components, therefore saving the cost of documenting and fabricating these components when implementing a new 5-hp compressor.

Hanson, T. R.↗

Minimizing noise-temperature measurement errors

An analysis of noise-temperature measurement errors of low-noise amplifiers was performed. Results of this analysis can be used to optimize measurement schemes for minimum errors. For the cases evaluated, the effective noise temperature (Te) of a Ka-band maser can be measured most accurately by switching between an ambient and a 2-K cooled load without an isolation attenuator. A measurement accuracy of 0.3 K was obtained for this example.

Stelzried, C. T.↗