Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

BEYONDPLANCK XIV. Polarized foreground emission between 30 and 70 GHz

We constrain polarized foreground emission between 30 and 70 GHz with the Planck Low Frequency Instrument (LFI) and WMAP data within the global Bayesian BeyondPlanck framework. We combine for the first time full-resolution Planck LFI time-ordered data with low-resolution WMAP sky maps at 33, 40 and 61 GHz. Spectral parameters are fit with a likelihood defined at the native resolution of each frequency channel. This analysis represents the first implementation of true multi-resolution component separation applied to CMB observations for both amplitude and spectral energy distribution (SED) parameters. For synchrotron emission, we approximate the SED as a power-law in frequency and find that the low signal-to-noise ratio of the current data strongly limits the number of free parameters that may be robustly constrained. We partition the sky into four large disjoint regions (High Latitude; Galactic Spur; Galactic Plane; and Galactic Center), each associated with its own power-law index. We find that the High Latitude region is prior-dominated, while the Galactic Center region is contaminated by residual instrumental systematics. The two remaining regions appear to be signal-dominated, and for these we derive spectral indices of $β$ S Spur = -3.17 ± 0.06 and $β$ S Plane = -3.03 ± 0.07, in good agreement with previous results. For thermal dust emission we assume a modified blackbody model and we fit a single power-law index across the full sky. We find $β$ d = 1.64 ± 0.03, which is slightly steeper than reported from Planck HFI data, but still statistically consistent at the 2σ confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Glue in hadrons at medium resolution and the QCD instanton vacuum

We discuss a general framework for the evaluation of the gluonic form factors in light hadrons at low momentum transfer, in the QCD instanton vacuum. At medium resolution of the order of the inverse mean instanton size, the glue is mostly localized in single or pairs of pseudoparticles and globally constrained by the fluctuations of their topological charges. These pseudoparticles trap light quarks, giving rise to emerging multiflavor ’t Hooft interactions. We explicitly evaluate the gluonic scalar, pseudoscalar, energy-momentum tensor (EMT), and the leading C -odd and C -even three-gluon hadronic form factors, at next to leading order in the instanton density, including molecular clusters of like and unlike instantons. We use the results for the EMT to address the contribution of the gluons in Ji’s mass and spin sum rules, at low resolution. When evolved, our results for the mass and spin composition of the nucleon are shown to be in good agreement with the recently reported lattice results at higher resolution. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Low-energy magneto-optics of Tb 2 Ti 2 O 7 in a [111] magnetic field

The pyrochlore magnet Tb 2 Ti 2 O 7 shows a lack of magnetic order to low temperatures and is considered to be a quantum spin liquid candidate. Here we perform time-domain THz spectroscopy on high-quality Tb 2 Ti 2 O 7 crystals and study the low-energy excitations as a function of [111] magnetic field with high energy resolution. The low-energy crystal-field excitations change their energies anomalously under magnetic field. Despite several sharp field-dependent changes, we show that the material's spectrum can be described not by phase transitions but by field-dependent hybridization between the low-energy crystal-field levels. We highlight the strong coupling between spin and lattice degrees of freedom in Tb 2 Ti 2 O 7 as evidenced by the magnetic-field tunable crystal-field environment. Calculations based on single ion physics with field-induced symmetry reduction of the crystal-field environment can reproduce our data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Daily, 30 m Resolution NDSI Data for the East River Watershed, CO for 2000-2020

This dataset contains daily Normalized Difference Snow Index (NDSI) values at 30 m spatial resolution for the East River watershed in Colorado, USA. The temporal range of these data includes water years 2001-2020. These data were created using the Spatial and Temporal Adaptive Reflectance Fusion Model (STARFM). This model fuses low spatial and high temporal resolution data from MODIS (500 m, daily) with high spatial and low temporal resolution data from Landsat (30 m, 16 days) to create a 30m synthetic daily snow product. This product allows for the analysis of historical snow covered area trends in the East River Watershed at fine spatiotemporal resolutions where it was not available previously. This research was performed as a part of the Department of Energy’s Subsurface Biogeochemical Research Program with the primary intent of better understanding the timing and spatial patterns of water delivery to the Critical Zone in mountain watersheds. Each .zip file contains one "water year" of data (October 1 - September 30; i.e., water year 2010 starts October 1, 2010 and ends September 30, 2011). Each zip file contains the following: STARFM daily Normalized Difference Snow Index (NDSI) fusion data files in GeoTiff format with one layer for each day between Landsat data acquisition dates (i.e., for dates of Landsat acquisition, the Landsat image is included for that date). The study area is located in an area of Landsat path overlap, so Landsat dates acquisitions are every 7-9 days. Landsat NDSI files containing the high spatial (30m), low temporal (7-9 days due to Landsat path overlap) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Dates for which no Landsat data were obtained are included as NoData layers. MODIS NDSI files containing the high temporal (daily), low spatial (500m) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Please note the MODIS data were resampled to 30m pixels for input into the STARFM model. The data have a scale factor of 10,000 and a no data value of -32767. The projection of all datasets is WGS 84 (EPSG: 4326), which has a latitude/longitude based degree resolution of 0.0002694946 X 0.0002694946, and approximates to the 30 m spatial resolution mentioned above. The Layer Index files in .csv format. They contain information for each layer in the above GeoTiff files regarding the corresponding date for each layer, the fraction of pixels in the image that contain valid data (missing data is due to either cloud cover or poor data quality; these values are not percent snow cover). Dates of Landsat overpass are indicated in these files. If no Landsat data were able to be obtained due to cloud cover or lack of Landsat Tier 1 data available on Google Earth Engine, this is also noted.

EARTH SCIENCE > CRYOSPHERE > SNOW/ICE↗

Experiment definition and integration study for the accommodation of giant, passive detector of Exotic Particles In the Cosmic Rays (EPIC) payload on shuttle/spacelab missions

The feasibility of the design, construction, launch and retrieval of a hinged 15 ft by 110 ft the platform containing an array of interleaved CR-39 and Lexan track-recording detectors to be placed into circular orbit by space shuttle is assessed. The total weight of the detector assembly plus supporting structure and accessories is 32,000 pounds. The modular construction permits as little as one fourth of the payload to be exposed at one time. The CR-39 detector has sensitivity adequate to detect and study cosmic rays ranging from minimum ionizing iron-group nuclei to the heaviest elements. The detectors will survive a one year exposure to trapped protons without losing their high resolution. Advantages include low cost, huge collecting power (approximately 150 sq m) as well as the high resolution previously attainable only with electronic detectors.

Price, P. B.↗

A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources

In recent years much effort has been devoted to the development of large area gas scintillation proportional counters (GSPCs) suitable for use in X-ray astronomy. The paper deals with a low-energy GSPC for use in detecting sub-keV X-rays from cosmic sources. This instrument has a measured energy resolution of 85 eV (FWHM) at 149 eV over a sensitive area of 5 sq cm. The development of imaging capability for this instrument is discussed. Tests are performed on the feasibility of using an arrangement of several phototubes placed adjacent to one another to determine event locations in a large flat counter. A simple prototype has been constructed and successfully operated.

Hamilton, T. T.↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Development of a procedure to model high-resolution wind profiles from smoothed or low-frequency data

The derivation of simulated Jimsphere wind profiles from low-frequency rawinsonde data and a generated set of white noise data are presented. A computer program is developed to model high-resolution wind profiles based on the statistical properties of data from the Kennedy Space Center, Florida. Comparison of the measured Jimsphere data, rawinsonde data, and the simulated profiles shows excellent agreement.

Camp, D. W.↗

The Lunar Observer Radio Astronomy Experiment (LORAE)

The paper proposes to place a simple low-frequency dipole antenna on board the Lunar Observer (LO) satellite. LO will orbit the moon in the mid-1990's, mapping the surface at high resolution and gathering new geophysical data. In its modest concept, LORAE will collect crucial data on the radio interference environment while on the near-side (to aid in planning future arrays) and will monitor bursts of emission from the sun and the Jovian planets. LORAE will also be capable of lunar occultation studies of greater than 100 of the brightest sources, gathering arcminute resolution data on sizes and measuring source fluxes. A low resolution all-sky map below 10 MHz, when combined with data from the Gamma-Ray Observatory, will uniquely determine the density of Galactic cosmic ray electrons and the strength of the Galaxy's magnetic field. LORAE also will be able to measure the density of the moon's ionosphere.

Burns, Jack O.↗

Studies of Avalanche Photodiodes (APDS) as Readout Devices for Scintillating Fibers for High Energy Gamma-Ray Astronomy Telescopes

New gamma ray and charged particle telescope designs based on scintillating fiber arrays could provide low cost, high resolution, lightweight, very large area and multi radiation length instrumentation for planned NASA space exploration. The scintillating fibers low visible light output requires readout sensors with single photon detection sensitivity and low noise. The sensitivity of silicon Avalanche Photodiodes (APDS) matches well the spectral output of the scintillating fibers. Moreover, APDs have demonstrated single photon capability. The global aim of our work is to make available to NASA a novel optical detector concept to be used as scintillating fiber readouts and meeting the requirements of the new generations of space-borne gamma ray telescopes. We proposed to evaluate the feasibility of using RMD's small area APDs ((mu)APD) as scintillating fiber readouts and to study possible alternative (mu)APD array configurations for space borne readout scintillating fiber systems, requiring several hundred thousand to one million channels. The evaluation has been conducted in accordance with the task description and technical specifications detailed in the NASA solicitation "Studies of Avalanche Photodiodes (APD as readout devices for scintillating fibers for High Energy Gamma-Ray Astronomy Telescopes" (#8-W-7-ES-13672NAIS) posted on October 23, 1997. The feasibility study we propose builds on recent developments of silicon APD arrays and light concentrators advances at RMD, Inc. and on more than 5 years of expertise in scintillating fiber detectors. In a previous program we carried out the initial research to develop a high resolution, small pixel, solid-state, silicon APD array which exhibited very high sensitivity in the UV-VIS spectrum. This (mu)APD array is operated in Geiger mode and results in high gain (greater than 10(exp 8)), extremely low noise, single photon detection capability, low quiescent power (less than 10 (mu)W/pixel for 30 micrometers sensitive area diameter) and output in the 1-5 volt range. If successful, this feasibility study will make possible the development of a scintillating fiber detector with unsurpassed sensitivity, extremely low power usage, a crucial factor of merit for space based sensors and telescopes.

Vasile, Stefan↗

DRAGraces: A Pipeline for the GRACES High-resolution Spectrograph at Gemini

This paper describes the software Data Reduction and Analysis for GRACES (DRAGraces), which is a pipeline reducing spectra from Gemini Remote Access to the CFHT ESPaDOnS Spectrograph (GRACES) at the Gemini North Telescope. The code is written in the IDL language. It is designed to find all the GRACES frames in a given directory, automatically determine the list of bias, flat, arc, and science frames, and perform the whole reduction and extraction within a few minutes. We compare the output from DRAGraces with that of the Open source Pipeline for ESPaDOnS Reduction and Analysis (OPERA), a pipeline developed at the Canada–France–Hawaii Telescope (CFHT) that also can extract GRACES spectra. Both pipelines were developed completely independently, yet they give very similar extracted spectra. They both have their advantages and disadvantages. For instance, DRAGraces is more straightforward and easy to use and is less likely to be derailed by a parameter that needs to be tweaked, while OPERA offers a more careful extraction that can be significantly superior when the highest resolution is required and when the signal-to-noise ratio is low. One should compare both before deciding which one to use for their science. Yet, both pipelines deliver a fairly comparable resolution power (R ~ 52.8k and 36.6k for DRAGraces and R ~ 58k and 40k for OPERA in high- and low-resolution spectral modes, respectively), wavelength solution, and signal-to-noise ratio per resolution element.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic electron flux comparisons at low and high altitudes with fast time resolution and broad spatial coverage

Analyses are presented for the first high-time resolution multisatellite study of the spatial and temporal characteristics of a relativistic electron enhancement event with a rapid onset. Measurements of MeV electrons were made from two low-altitude polar orbiting satellites and three spacecraft at synchronous altitude. The electron fluxes observed by the low-altitude satellites include precipitating electrons in both the bounce and drift loss cones as well as electrons that are stably trapped, whereas the observations at geosynchronous altitude are dominated by the trapped population. The fluxes of greater than 1 MeV electrons at low-satellite altitude over a wide range of L shells tracked very well the fluxes greater than 0.93 MeV at synchronous altitude.

Imhof, W. L.↗

Space Acceleration Measurement System for Free Flyers

Experimenters from the fluids, combustion, materials, and life science disciplines all use the microgravity environment of space to enhance their understanding of fundamental physical phenomena caused by disturbances from events such as spacecraft maneuvers, equipment operations, atmospheric drag, and (for manned flights) crew movement. Space conditions reduce gravity but do not eliminate it. To quantify the level of these disturbances, NASA developed the Space Acceleration Measurement System (SAMS) series to collect data characterizing the acceleration environment on the space shuttles. This information is provided to investigators so that they can evaluate how the microgravity environment affects their experiments. Knowledge of the microgravity environment also helps investigators to plan future experiments. The original SAMS system flew 20 missions on the shuttle as well as on the Russian space station Mir. Presently, Lewis is developing SAMS-II for the International Space Station; it will be a distributed system using digital output sensor heads. The latest operational version of SAMS, SAMS-FF, was originally designed for free flyer spacecraft and unmanned areas. SAMS-FF is a flexible, modular system, housed in a lightweight package, and it uses advances in technology to improve performance. The hardware package consists of a control and data acquisition module, three different types of sensors, data storage devices, and ground support equipment interfaces. Three different types of sensors are incorporated to measure both high- and low-frequency accelerations and the roll rate velocity. Small, low-power triaxial sensor heads (TSH's) offer high resolution and selectable bandwidth, and a special low-frequency accelerometer is available for high-resolution, low-frequency applications. A state-of-the-art, triaxial fiberoptic gyroscope that measures extremely low roll rates is housed in a compact package. The versatility of the SAMS-FF system is shown in the three different types of missions SAMS-FF has supported.

Kacpura, Thomas J.↗

Investigation of N in Ammonium-bearing Silicates with Electron Probe Microanalysis (EPMA)

Nitrogen is a primary constituent of Earth’s atmosphere and an essential component of many biological processes. Recent developments in understanding N incorporation into silicate minerals suggest that the solid earth and lithosphere could provide a substantial reservoir for the planetary N budget. Furthermore, determining the concentration and distribution of low abundances of N in silicates presents a significant challenge in microanalysis. We tested capabilities for high spatial resolution quantification of low levels of N using EPMA with the goal of developing standards to be used in coupled N and noble gas analyses of silicate minerals. We investigated the concentration and distribution of N in a suite of ammonium-bearing silicate minerals that reflect the dominant N-bearing phases of the lithosphere: tobelite, buddingtonite, ammonioleucite, tsaregorodtsevite, and hyalophane. These minerals form during NH4-rich alteration of K-bearing silicate minerals, and the bonding environment of N in each mineral is likely to differ based on crystal structure. Using an optimized analytical routine for N quantification enables sensitivity approaching 0.02 weight% N and high-resolution quantitative mapping of sub-micron variations in N contents.

58 GEOSCIENCES↗

Storage and Diffusion of Carbon and Nitrogen in Crustal Materials

Nitrogen is a primary constituent of Earth’s atmosphere and an essential component of many biological processes. Recent developments in understanding N incorporation into silicate minerals suggest that the solid earth and lithosphere could provide a substantial reservoir for the planetary N budget. Furthermore, determining the concentration and distribution of low abundances of N in silicates presents a significant challenge in microanalysis. We tested capabilities for high spatial resolution quantification of low levels of N using EPMA with the goal of developing standards to be used in coupled N and noble gas analyses of silicate minerals. We investigated the concentration and distribution of N in a suite of ammonium-bearing silicate minerals that reflect the dominant N-bearing phases of the lithosphere: tobelite, buddingtonite, ammonioleucite, tsaregorodtsevite, and hyalophane. These minerals form during NH 4 -rich alteration of K-bearing silicate minerals, and the bonding environment of N in each mineral is likely to differ based on crystal structure. Using an optimized analytical routine for N quantification enables sensitivity approaching 0.02 weight% N and high-resolution quantitative mapping of sub-micron variations in N contents.

58 GEOSCIENCES↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

Landform identification in lunar radar images

Lunar radar images have been investigated in order to understand how various radar parameters affect landform identification. The high-resolution (1-2 km cell size) 3.8-cm images of Zisk et al. (1974) were used along with the low and high resolution 70-cm mosaics of Thompson (1974 and 1987). The results indicate that radar cell size is the single most important radar parameter and that lunar features are likely to be correctly identified if they are longer than an 'identification resolution' of five times the radar cell size. The moon is considered here as an analog of Venus, since the two planets have similar mean scattering behavior.

Thompson, T. W.↗