Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Autoignition Delay Time Measurements and Chemical Kinetic Modeling of Hydrogen/Ammonia/Natural Gas Mixtures

Abstract In recent years, hydrogen-carrying compounds have accrued interest as an alternative to traditional fossil fuels due to their function as zero-emission fuels. As such, there is interest in investigating hydrogen-carrying compounds to improve understanding of the fuels’ characteristics for use in high-pressure systems. In the current study, the oxidation of ammonia/natural gas/hydrogen mixtures was carried out to study CO formation profiles as well as the ignition delay times behind reflected shock waves in order to refine chemical kinetic models. Experiments were carried out in the University of Central Florida’s shock tube facility by utilizing chemiluminescence to obtain OH* emission and laser absorption spectroscopy to obtain CO profiles. Experimental results were then compared with the GRI 3.0 mechanism, as well as the proprietary UCF 2022 mechanism utilizing CHEMKIN-Pro software. In general, both models were able to capture the trend in autoignition delay times and CO time histories for natural gas and ammonia mixtures. However, for ammonia-hydrogen mixtures, GRI 3.0 failed to predict ignition delay times whereas the UCF 2022 mechanism was able to capture the IDTs within the uncertainty limits of the experiments. A sensitivity analysis was conducted for different mixtures to understand the important reactions at the experimental conditions. Finally, a reaction pathway analysis was carried out to understand important ammonia decomposition pathways in the presence of hydrogen and natural gas.

Baker, Jessica B.↗

Method for boosting dispersive spectrograph stability 1000× using interferometry with crossfaded pairs of delays

We demonstrate a key step along a technical route to achieving cm/s scale accuracy for astronomical spectrographs over long (multi-year) time scales, which is critical for the Doppler characterization of Earth sized exoplanets, and measurement of small cosmic redshift drift over many years. This same technique also enables searching exoplanet atmospheres for biosignificant molecules in direct planet imaging using, otherwise, insufficiently low resolution and drift prone dispersive (grating or prism) spectrographs. Using a method called crossfading for externally dispersed interferometers (EDIs) to get highly robust spectra, we recently demonstrated a factor of 1000 x reduction in the net shift of an EDI measured ThAr line to a deliberate simulated wavelength translation of the detector. This 1000 x gain in disperser stability can be combined with conventional stability gains afforded by fiber scramblers, vacuum tanks, and thermal control, to provide an additional 1 to 3 orders of magnitude reduction in the net point spread function shift drift. Crossfading combines high- and low-delay fringing signals that react oppositely in phase to cancel their net reaction to a detector wavelength drift. This can be implemented by an interferometer addition to a facility spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗

Determination of Particle Size Distribution of Zirconium Dioxide Powders by Static Laser Scattering and Optical Microscopy

Dispersing conditions of powdered zirconium dioxide with addition of 3 mol % yttrium oxide are determined. The particle size distribution of the powders is determined by static laser scattering and optical microscopy. The zeta potential of suspension of zirconium dioxide particles as a function of pH of medium is measured by electrophoresis with titration. The influence of acidity on suspension stability during measurements is studied. It is demonstrated that a stable suspension can be obtained by shift of pH to both the acid and alkaline regions as well as by addition of surfactants, such as Dolapix CE 64.

36 MATERIALS SCIENCE↗

Hydrogen lines in the infrared region and spectral background for the thomson scattering diagnostics of the iter divertor plasma

Calculations are made of the plasma spectral background, which is important for the Thomson scattering diagnostics in the ITER divertor. Theoretical grounds have been elaborated for computing the hydrogen spectral line shapes in the infrared spectral region for a divertor plasma in ITER. The shape of the P-7 Paschen line (transition n = 7 {yields} n = 3) located near the laser scattering signal has been calculated for various lines of sight in the ITER divertor. Contributions from different mechanisms of broadening the P-7 line have been examined. The spectral intensities of bremsstrahlung and photorecombination continuum have been calculated. All calculations use data on the spatial distribution of temperatures and densities of all species of plasma particles computed with the SOLPS4.3 code for basic operation regimes of the ITER divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Evaporation of Laser-Heated Iron–Carbon Nanoparticles Using Analysis of Thermal Radiation

Evaporation of iron nanoparticles in carbon shells under pulsed laser irradiation is analyzed. Iron–carbon nanoparticles are synthesized in a shock tube reactor with the aid of pyrolysis of the 0.25% Fe(CO){sub 5} + 0.25% C{sub 6}H{sub 6} mixture in argon. Laser radiation is used for additional heating to temperatures that exceed the evaporation threshold of the iron core of nanoparticles. Time profiles of the thermal radiation of laser-heated nanoparticles are measured. The two-color pyrometry is used to determine the evaporation temperature of nanoparticles, and the laser extinction makes it possible to monitor the loss of volume fraction of the condensed phase upon evaporation. Approximation of experimental signals of laser-heated nanoparticles using model curves is employed to determine effective enthalpy of evaporation of iron–carbon nanoparticles. It is shown that the iron core of nanoparticles is evaporated through the carbon shell and the energy spent by such a process is approximately twice greater than the evaporation enthalpy of bulk iron with free surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Experimental Investigation and CFD Analysis of Steam Ingress Accidents in HTGRs

This study focuses on the short-term phenomena due to steam ingress following an SG tube rupture accident in HTGRs, instead of covering a long-term scenario induced by a small amount of steam ingress during plant lifetime. Our ultimate goal is to better understand water/steam ingress accidents in HTGRs, where the Rankine cycle is adopted as the power conversion cycle. General Atomics’ 350 MWth Modular High Temperature Gas-cooled Reactor (MHTGR) was chosen as the prototypic reactor design. The models of steam nuclear graphite oxidation proposed in the literature are surveyed, and will be examined, validated or improved if needed. Furthermore, this study aims to develop and validate a predictive tool for steam ingress accidents. To measure the steam concentration evolution in an integral effect test (IET) facility, a tunable diode laser absorption spectroscopy (TDLAS) measurement system was developed. The TDLAS measuring system is a non-intrusive and non-perturbative diagnostic technique that can be used to measure the steam temperature and concentration at various conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Aluminum Metal Powders for Plutonium-238 Program

As part of radioisotope thermoelectric generator (RTG) production for power sources in deep space exploration, Oak Ridge National Laboratory (ORNL) produces plutonium-238 ( 238 Pu). To produce 238 Pu, neptunium-237 ( 237 Np) targets are fabricated at ORNL and subsequently irradiated at the High Flux Isotope Reactor (HFIR) at ORNL and the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Specifically, current flowsheets utilize neptunium dioxide ( 237 NpO 2 ) targets. Aluminum (Al) powder is blended with 237 NpO 2 target material to improve thermal conductivity during irradiation. The current composition of 237 NpO 2 /Al pellets (i.e., cermets, or ceramic–metallics) is 20% 237 NpO 2 , 70% Al, and 10% void space. Al powders utilized by the 238 Pu program are high-fired under vacuum before blending into targets. The primary objective of this work is to measure the physical, chemical, and thermal properties of Al before and after the high-firing process. Properties of interest include the morphology, surface texture, particle size, crystal phase(s), and thermal conductivity of the material. These properties are measured with existing materials characterization equipment at ORNL, including powder x-ray diffraction (pXRD), scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS), laser flash analysis (LFA), and thermogravimetric analysis (TGA). A secondary objective of this work is to compare the Al powders before and after the high-firing procedure to determine the effects of high-firing on chemical, physical, and thermal properties and to determine the efficacy of the high-firing process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

Experimental Measurements of Soot and Soot Precursors of Sustainable Aviation Fuels

Sustainable Aviation Fuels (SAFs) are promising for decarbonizing the challenging-to-electrify aerospace sector and reducing yearly greenhouse gas emissions by thousands of tons. Developing predictive detailed chemical kinetic models for SAF (and traditional) fuel mixtures necessitates a robust experimental database to elucidate the intricate pyrolysis and oxidation chemistry of SAF fuel blend components. Two critical components of SAF surrogate mixtures are iso-dodecane isomers and trans-decalin. This report characterizes the structure of three slightly sooting, laminar, non-premixed, nitrogen-diluted Planar Mixing Layer Flames (PMLFs) fueled by either pure ethylene, ethylene doped with 1500ppm of either 2,2,4,6,6-pentamethyl-heptane or trans-decalin. The flames have the same stoichiometric mixture fraction and total mole fraction of fuels in the fuel stream (X F,F = X C2H4,F + X Dopant,F = 0.26), resulting in approximately the same maximum temperature (T max ≈ 1800 K) to highlight the effect of doping on soot and its gaseous precursors. The PMLF is unconfined and established between adjacent planar jets of the fuel and oxidizer streams surrounded by annular shielding nitrogen. The flow is stabilized by exhausting the hot buoyant flame products through a slot in a downstream plate onto which the cold flow impinges. Importantly, any horizontal cross-section of the PMLF has a self-similar thermochemical structure of a reactive boundary layer that grows at increasing Height Above the Burner (HAB). Therefore, the horizontal cross-sections of a PMLF can be modeled as a One-Dimensional Counterflow Flame (1D-CF) with very low strain rates which are unachievable in traditional CFs and yield a structure that is several millimeters thick. In brief, the PMLF is ideal for performing spatially resolved measurements with minimal effects of the sampling-induced perturbations, to develop and validate detailed chemical kinetic models on time scales of a few tens of milliseconds that are relevant in aviation applications. The horizontal profiles of C0-C18 gaseous species at HAB = 50 mm and soot volume fraction at 25 and 50 mm are measured using capillary sampling followed by GC-MS analyses and Laser Induced Emission Spectroscopy (LIES), respectively. Additionally, the Elastic Laser Light Scattering (E-LLS) coefficient is measured at HAB = 50 mm and 25 mm to determine the strain rates of the 1D-CFs equivalent to the characterized PMLF horizontal cross sections and the profile of the E-LLS equivalent diameter of soot. The comparison of the results in the base PMLF fueled only by ethylene with those in either doped PMLF in which 1500 ppm of ethylene are replaced with 2,2,4,6,6-pentamethyl-heptane or trans-decalin, reveals that the doping increases the mole fraction of several Polycyclic Aromatic Hydrocarbons (PAHs) at both HABs by a factor of approximately 2.5, and the soot volume fraction at both HABs by factors of ~1.5 for 2,2,4,6,6-pentamethyl-heptane and ~1.25 for trans-decalin doping, respectively. Conversely, doping causes a near doubling of the soot equivalent diameter only at HAB = 50 mm, without significant effects at 25 mm. The experimental results partially validate the tested state-of-the-art detailed chemical kinetic model and also point toward the further improvement of its predictive capabilities.

10 SYNTHETIC FUELS↗

Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Measurement System Description and Mass Balance Approach

Natural gas is an abundant resource across the United States, of which methane (CH4) is the main component. About 2% of extracted CH4 is lost through leaks. The Remote Methane Leak Detector (RMLD)-Unmanned Aerial Vehicle (UAV) system was developed to investigate natural gas fugitive leaks in this study. The system is composed of three major technologies: miniaturized RMLD (mini-RMLD) based on Backscatter Tunable Diode Laser Absorption Spectroscopy (TDLAS), an autonomous quadrotor UAV and simplified quantification and localization algorithms. With a miniaturized, downward-facing RMLD on a small UAV, the system measures the column-integrated CH4 mixing ratio and can semi-autonomously monitor CH4 leakage from sites associated with natural gas production, providing an advanced capability in detecting leaks at hard-to-access sites compared to traditional manual methods. Automated leak characterization algorithms combined with a wireless data link implement real-time leak quantification and reporting. This study placed particular emphasis on the RMLD-UAV system description and the quantification algorithm development based on a mass balance approach. Early data were gathered to test the prototype system and to evaluate the algorithm performance. The quantification algorithm derived in this study tended to underestimate the gas leak rates and yielded unreliable estimations in detecting leaks under 7 × 10 − 6 m3/s (~1 Standard Cubic Feet per Hour (SCFH)). Zero-leak cases can be ascertained via a skewness indicator, which is unique and promising. The influence of the systematic error was investigated by introducing simulated noises, of which Global Positioning System (GPS) noise presented the greatest impact on leak rate errors. The correlation between estimated leak rates and wind conditions were investigated, and steady winds with higher wind speeds were preferred to get better leak rate estimations, which was accurate to approximately 50% during several field trials. High precision coordinate information from the GPS, accurate wind measurements and preferred wind conditions, appropriate flight strategy and the relative steady survey height of the system are the crucial factors to optimize the leak rate estimations.

03 NATURAL GAS↗