Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Cyclic Background Noise Variations on Infrasound Microbarometers From Micrometeorology and Human Activity

Infrasound microbarometers deployed on the Earth's surface capture pressure fluctuations and acoustic signatures, revealing trends in surface wind speed and cycles in ambient sound. Previous studies investigated wind noise trends at quarter day resolution and urban acoustic background variations on hourly to weekly scales. Cyclic variations at sub-hourly resolution over local distances remain unaddressed. We show that topography-driven micrometeorology impacts diurnal background noise levels below 10 Hz. Anthropogenic noise occurs over daily and weekly cycles, with inputs from traffic, ventilation systems, and power lines. These noise patterns vary at stations spaced less than a kilometer apart. We observe these phenomena by using a circular spectrogram to visualize frequency trends over a periodic temporal scale. This study demonstrates that infrasound microbarometer deployments can highlight localized wind patterns and time scales of human activity. The results suggest that future microbarometer deployments may benefit from site noise surveys before selecting final sensor locations.

Malach, Amrit Kaur [Sandia National Lab. (SNL-CA),↗

AN OVERVIEW OF PLASMA PROCESSING OF SRF CAVITIES AT JLAB

Plasma processing is a common technique where the free oxygen produced in a low-pressure RF plasma breaks down and removes hydrocarbons from surfaces. This increases the work function and reduces the secondary emission coefficient of the treated surfaces. Jefferson Lab has an ongoing R&D program in plasma processing. The experimental program investigated processing using argon/oxygen and helium/oxygen gas mixtures. The initial focus of the effort was processing C100 cavities by injecting RF power into the HOM coupler ports. We also developed the methods for establishing a plasma C75 cavities where the RF power is injected via the fundamental power-coupler. As part of the process development we processed, three C100 cryomodules in our off-line cryomodule test facility. In May 2023 we processed four C100 cryomodules in-situ in the CEBAF accelerator with the cryomodules returning to an operational status in Sept. 2023. The cumulative improvement in field emission free operation, as measured on a cavity by cavity basis, was 59 MeV or 24%. We recently started processing 7 cryomodules in the CEBAF accelerator in August 2024. Methods systems and results from processing cryomodules and individual cavities in the vertical test will be presented. Current status and future plans will also be presented.

Ganey, Tiffany↗

Development of Elastic Recoil Detection Technique for Quantifying Light Isotope Concentrations in Irradiated TPBAR Materials.

The National Nuclear Security Administration's Tritium Sustainment Program is responsible for the design, development, demonstration, testing, analysis, and characterization of tritium-producing burnable absorber rods (TPBARs) and their components, in addition to producing tritium for the nation's strategic stockpile. The FY18 call for proposals included the specific basic science research topic, "Demonstration and evaluation of advanced characterization methods, particularly for quantifying the concentration of light isotopes ( 1 H, 2 H, and 4 He, 6 Li, and 7 Li) in metal or ceramic matrices". A project IWO-389859 was awarded to the Ion Beam Lab (IBL) at Sandia-NM in FY18. This reports the success we had in developing and demonstrating such a method: 42 MeV Si + 7 from the IBL' s Tandem was used to recoil these light isotopes into special detectors that separated all these isotopes by simultaneously measuring the energy and stopping power of these reoils. This technique, called Heavy Ion - Elastic Recoil Detection or HI-ERD, accurately measured the enriched 6 Li/Li-total of 0.246 +- 0.016, compared to the known value of 0.239. The isotopes 1 H, 2 H, 4 He, 6 Li and 7 Li were also measured. (page intentionally left blank)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE↗

Synopsis of NREL's Automated Mobility District (AMD) Research Program and Associated Publications

An automated mobility district (AMD) envisions a system of integrated mobility options that serves major activity centers such as campuses, central business districts, and large medical facilities. The National Renewable Energy Laboratory (NREL) has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings. This document provides a synopsis of findings revealed over the last three phases of work, which have yielded insights into the creation and management of AMDs anticipated to use automated vehicle (AV) technology over the next decade. Phase I and Phase II tracked the deployment and lessons learned from 10 early-stage demonstrations of automated shuttle deployments, and their associated insights into the challenges for automated driving systems to achieve safe operations within district-scale deployments. Phase III began in-depth investigations of critical subsystem components, as automation, electrification, and on-demand service continue to converge within initial AMD operations. These directed studies focus on elements of electrification, curbfront/station management, the role of infrastructure sensing, and overall integration of AMD safety management in central, simultaneous coordination of multiple AMD fleets. Future research in AMDs includes systems engineering methodology (more frequently referred to as "digital twins") for planning, design, testing, and ongoing operation of AMDs; location (or co-location) of management functions; and human supervision and passenger communications for safety and security in unattended vehicles. The synopsis references the foundational research products (papers and presentations) that have been published through conference proceedings, journal articles, and NREL reports.

33 ADVANCED PROPULSION SYSTEMS↗

Status of the PrimEx $\eta$ experiment at Jefferson Lab

The GlueX detector in the experimental Hall D at Jefferson Lab offers a unique opportunity to perform a measurement of the decay width of eta mesons through the Primakoff effect. The experiment complements the physics program at Jefferson Lab on measuring the decay width of light pseudoscalar mesons via the Primakoff process. The goal of the experiment is to measure differential cross sections of eta mesons at forward angles using a beam of tagged photons incident on a liquid 4He target, which will be used for the extraction of the decay width. This measurement is vital for understanding fundamental properties like the ratios of the light quark masses and the eta - eta' mixing angle, and will provide an important test of chiral symmetry breaking in QCD. Our experimental results will help reduce uncertainties on partial widths of all other eta decays. The experiment collected data during three physics runs between 2019 and 2022. We will give an overview of the PrimEx eta experiment and the current status of our data analyses. We will also discuss the feasibility of conducting future Primakoff measurements in light of the recent upgrade of the GlueX forward calorimeter and the potential accelerator energy upgrade to 22 GeV.

Somov, Alexander↗

From lab to lamp: Understanding downconverter degradation in LED packages

Downconverters, primarily inorganic phosphors, are critical components in white solid-state LED-based lighting and liquid crystal display backlights. Research efforts have led to a fundamental understanding of a downconverter's absorption, photoluminescence, and efficiency as a function of composition, structure, and processing conditions. However, considerably less work has focused on the reliability of phosphors once they are incorporated into LED packages. Solving these issues is often the final step before the commercialization of new materials, but the significant resources and time required to evaluate and mitigate materials failure are rarely discussed in the literature. In this Perspective, we discuss the need for conducting downconverter reliability testing and the potential of accelerating, screening, and understanding downconverter failure modes. Our focus highlights the mechanisms of failure and discusses how this influences materials selection and the design of different LED packages. We also stress the potential for accelerated reliability testing protocols and note the potential role first-principles calculations and data-driven models could play in establishing the compositional-processing trends for different aspects of downconverter reliability. In conclusion, we close with possible research directions that could improve downconverter reliability and emphasize the importance of assessing a material's (chemical) stability where multiple manufacturing and processing steps can dictate system performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Versatile common instrumentation for optical detection of pH and dissolved oxygen

The recent trend toward use of disposable and miniature bioreactors requires the use of appropriate sensors. pH and dissolved oxygen (DO) are often measured using optical chemical sensors due to their small form factor and convenience in use. These sensors are often interrogated using a specialized opto-electronic transducer that is designed around the optical sensor. In this contribution, we are presenting a new class of opto-electronic transducers that are usable with several different chemical sensors without the need to switch the optics or hardware when changing the type of the chemical sensor. This allows flexibility closer to the lab-grade devices while the size is closer to a dedicated sensor. This versatile instrumentation is capable of seamlessly switching between the pH and DO measurement modes and is capable of auto recognition of the sensor type. The principle of ratiometric fluorescence is used for pH measurements, and that of fluorescence lifetime for DO measurements. An approach to obtain identical calibrations between several devices is also presented. The described hardware constitutes common instrumentation for measuring either pH or DO and has been tested in actual bioprocesses. It has been found adequate for continuous bioprocess monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lagrange-Remap strategy for multi-material fluid-solid simulations using compressive limiters

In the present work, the Lagrange-Remap strategy proposed in [1] is extended to multi-material fluid-solid simulations. Both hypo-elastic and hyper-elastic material models are considered to describe the mechanical behavior of the solids. In practice, the deviatoric stress tensor (for hypo-elastic materials) and the left Cauchy-Green tensor (for isotropic hyper-elastic materials) are remapped, while the use of compressive limiters effectively reduces numerical diffusion during the remapping step. The simplicity of this diffuse interface approach is emphasized in the context of multi-material fluid-solid simulations. A series of Lagrange-Remap test cases, involving both solids and fluids, are conducted and compared with reference Lagrangian simulations, demonstrating the robustness and accuracy of the overall numerical strategy.

Compressive limiters↗

Investigation of the distribution of laser-induced damage precursors in etched grating sidewalls fabricated using inductively coupled plasma reactive-ion etching

Inductively coupled plasma reactive-ion etching for grating fabrication is explored with emphasis on the type and distribution of process-induced defects that can act as precursors to laser-induced damage initiation. To provide flexibility in the ability to perform a variety of material characterization methods, grating-like features with large pitch were fabricated in silica monolayers. The results indicate that the etch process introduces surface fluorine and subsurface carbon-containing contamination, which reduces the laser-induced damage threshold. The local relative concentrations of the laser-damage precursors introduced during the etch step of the manufacturing process were investigated using angle-resolved damage testing, taking advantage of the shift of the location of the peak electric-field intensity incident on the grating sidewall. The results suggest an increased level of etch-related defects near the base of the sidewall, with directly fluorinated silicon identified as the primary defect.

Dent, R. [Univ. of Rochester, NY (United States). ↗

An optimized prototype of electromagnetic calorimeter for the SoLID project at Jefferson Lab

A shashlik-type electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for the Solenoidal Large Intensity Device (SoLID). Wavelength-shifting (WLS) fibers and clear fibers will be used as the light guide part of the calorimeter. The blue light from scintillators is converted into green light by WLS fibers and is carried out to the back of the calorimeters for readout. Since the magnetic field of SoLID reaches about 1.5 T behind the calorimeters, the design is to use clear fibers to further guide the light out of the solenoid for readout by PMTs. Therefore, it is important to study the perfomance of WLS and clear fibers. This paper describes a comparative test of two different WLS fibers and a light attenuation test for a clear fiber. The results show that the performance of the two WLS fibers is the same under large curvature bending, and that the bending has no effect on the light transmission through the clear fiber. In addition, a comparison test for two fiber end-face reflective materials is also reported. It reveals that the use of silver ink as a reflective material can increase the light yield by 30%. Thereby, an optimized prototype based on the above experimental results was built and the basic performance was tested.

Shen, C.↗

η decay program at GlueX

The GlueX detector in the experimental Hall D at Jefferson Lab was designed to search for gluonic excitations in the spectra of light mesons using photon beams. The detector provides a unique capability to perform a precision measurement of the eta -> gamma gamma decay width via the Primakoff effect (PrimEx D experiment) and study rare decays of eta mesons. Measurement of the eta decay width is essential for the determination of fundamental properties such as the ratios of the light quark masses and the eta - eta' mixing angle, and will provide an important test of chiral symmetry breaking in QCD. The physics of rare eta decays spans from critical tests of chiral perturbation theory to the search for lepto-phobic dark matter candidates. I will give an overview of the ongoing PrimEx D experiment and the physics program of rare eta decays, and discuss GlueX plans for the future.

Somov, A.↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the interaction between MED5 and CDK8 in Arabidopsis

Plant metabolic networks are precisely regulated by the spatial and temporal expression of suites of genes. Among the various transcription (co)factors, a multi‐protein complex, Mediator has been identified as a hub for transcription regulation. The core Mediator complex, comprising the head, middle and tail domains, functions as a bridge between transcription factors and basal transcription machinery, whereas the CDK8 kinase module plays a repressive regulatory role. It is still unclear, however, how the kinase module represses target genes especially in planta . Using a forward genetic screen, our lab determined that MED5, an Arabidopsis Mediator tail subunit, is required for maintaining phenylpropanoid homeostasis. A semi‐dominant mutant ( ref4‐3 ) characterized by a single amino acid substitution in MED5a (G383S) was isolated as a strong suppressor of phenylpropanoid pathway, indicated by decreased soluble phenylpropanoid metabolite accumulation, reduced lignin content and dwarfism. In contrast, knocking out MED5a and MED5b ( med5a/5b ) results in the accumulation of increased levels of phenylpropanoid pathway derivatives. Considering that the CDK8 kinase module is a repressive module in Mediator, we tested the hypothesis that Arabidopsis MED5 represses phenylpropanoid pathway by interacting with CDK8. To test this hypothesis, CDK8 knockout lines ( cdk8‐1 ) were crossed with ref4‐3 , and the phenylpropanoid content of the resulting double mutants was evaluated. In ref4‐3 cdk8‐1 plants, the concentration of sinapate esters and total lignin content are as low as they are in ref4‐3 , yet the growth defect in ref4‐3 is largely rescued. To further determine the genes targeted by MED5 and CDK8 in maintaining proper plant growth, we performed an RNA‐seq analysis which showed that a majority of the genes involved in salicylic acid (SA) biosynthesis and signaling are up‐regulated in ref4‐3 compared to wild type and ref4‐3 cdk8‐1 . Consistent with this observation, both free and total SA, both of which have been previously implicated in dwarfing in lignin‐modified plants, are accumulated to elevated levels in ref4‐3 but not in wild type and ref4‐3 cdk8‐1 . Nevertheless, blocking SA biosynthesis is not sufficient to restore the growth deficiency of ref4‐3 , suggesting that the hyperaccumulation of SA is more likely to be an effect rather than a cause for its dwarf phenotype. At the molecular level, to elucidate how ref4‐3 regulates downstream gene targets in either a CDK8‐dependent manner, we performed RNA polymerase II (Pol II) ChIP‐seq analysis in wild type, ref4‐3 , cdk8‐1 and ref4‐3 cdk8‐1 . The Pol II ChIP‐seq data may provide additional information for us to identify the genes that are causative for the dwarfism of ref4‐3 . Taken together, this study identifies the genetic interaction between MED5 and CDK8 in Arabidopsis, which enhances our understanding in the function of Mediator in plant metabolism and its role in lignin‐modification‐induced dwarfism. Support or Funding Information Department of Energy; Global Climate and Energy Project This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Mao, Xiangying↗

1 K refrigerator for the CLAS12 Polarized Target Design, Construction, and First Results

A dynamically polarized target of protons and deuterons in irradiated NH3 and ND3 will be employed with the CLAS12 detector system to explore the spin structure of the nucleon in Hall B at Jefferson Lab. This target will feature a versatile, horizontal 1 K refrigerator that has been constructed by a collaboration of Christopher Newport University, Old Dominion University, the University of Virginia, and the JLab Target Group. A description of the challenges involved with designing the target for the CLAS12 experiments and the collaboration’s solutions will be presented. These include a modular and compact design of the 1 K refrigerator and its ancillary equipment, as well as a novel mechanism for loading the target samples. Initial test results of the system will also be included.

Brock, James↗