Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Hall B superconducting magnets for the CLAS12 detector at JLAB

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the 12 GeV upgrade is presented.

43 PARTICLE ACCELERATORS↗

Status of Hall B superconducting magnets for the CLAS12 detector at JLab

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the CLAS12 detector is presented.

43 PARTICLE ACCELERATORS↗

Magnetic System for the CLAS12 Proposal

The conceptual design of a magnetic system for an experiment to measure the transverse spin effects in semi-inclusive Deep Inelastic Scattering (SIDIS) at 11 GeV with a transversely polarized target using the CLAS12 detector at Jefferson Lab is presented. A proposal has been submitted to study spin azimuthal asymmetries in SIDIS using an 11-GeV polarized electron beam from the upgraded CEBAF facility and the CLAS12 detector equipped with a transversely polarized target. The main focus of the experiment will be the measurement of transverse target single and double spin asymmetries in the reaction ep{up_arrow} -> ehX, where e is an electron, p{up_arrow} is transversely polarized proton, h is a meson (e.g., a pion or a kaon) and X is the undetected final state. The details of the conceptual design of the shielding magnetic system and transverse dipole are reported.

43 PARTICLE ACCELERATORS↗

Analysis of Superconducting Dipole Coil of 11 GeV Super High Momentum Spectrometer

Jefferson Lab is constructing five Super High Momentum Spectrometer (SHMS) superconducting magnets for the 12 GeV Upgrade. This paper reports measured coil material properties and the results of the extensive finite element analysis (FEA) for the dipole coil. To properly define the smeared orthotropic material of the coil, a detailed coil model is set up to compute material parameters because not all parameters were measured. Stress and strain acceptance criteria are discussed. Eight load steps are defined. The preheat temperature of the force collar is optimized under two loading scenarios so that the positive pressure between the inner coil and central spacer is maintained while there is not too much squeeze to the coil.

Sun, Eric↗

Structural Analysis of Thermal Shields During a Quench of a Torus Magnet for the 12 GeV Upgrade

A toroidal magnet system consisting of six superconducting coils is being built for the Jefferson Lab 12- GeV accelerator upgrade project. This paper details the analysis of eddy current effects during a quench event on the aluminum thermal shield. The shield has been analyzed for mechanical stresses induced as a result of a coil quench as well as a fast discharge of the complete magnet system. The shield has been designed to reduce the eddy current effects and result in stresses within allowable limits.

43 PARTICLE ACCELERATORS↗

Electromagnetic and Mechanical Analysis of the Coil Structure for the CLAS12 Torus for 12 GeV Upgrade

The torus magnet for the CLAS12 spectrometer is a 3.6 T superconducting magnet being designed and built as part of the Jefferson Lab 12 GeV Upgrade. The magnet consists of six coil case assemblies mounted to a cold central hub. The coil case assembly consists of an aluminum case and cover enclosing an epoxy vacuum impregnated coil pack. The coil pack consists of a 117 turn double-pancake winding wrapped with 2 layers of 0.635 mm thick copper cooling sheets. The coil case assembly is cooled by supercritical helium at 4.6 K. This report details the structural analysis of the coil case assembly and the assessment of the coil pack stresses. For the normal operation of the torus magnet, the coil case assembly was analyzed for cool down to 4.6 K and the Lorentz forces at normal operating current. In addition to the normal operating configuration, the coil case assembly was analyzed for Lorentz forces arising from coil misalignment and current imbalances. The allowable stress criteria for the magnet followed the approach of the ASME codes. Primary stresses were limited to the lesser of 2/3 times the yield strength or 1/3 times the ultimate tensile strength. Primary plus secondary stresses were limited to 3 times the primary stress allowable. The analysis was performed using ANSYS Maxwell to calculate the magneto-static loads and ANSYS Mechanical to calculate the stresses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and Testing the 1970's Era LASS Solenoid Magnet in JLab's Hall D

JLab refurbished and reconfigured the LASS1, 1.85m bore Solenoid and installed it as the principal analysis magnet for nuclear physics in the newly constructed, Hall D at Jefferson Lab. The magnet contains four superconducting coils within an iron yoke. The magnet was built in the early1970's at Stanford Linear Accelerator Center and used a second time at Los Alamos National Laboratory. The coils were extensively refurbished and individually tested by JLab. A new Cryogenic Distribution Box provides cryogens and their control valving, current distribution bus, and instrumentation pass-through. A repurposed CTI 2800 refrigerator system and new transfer line complete the system. We describe the re-configuration, the process and problems of re-commissioning the magnet and the results of testing the completed magnet.

43 PARTICLE ACCELERATORS↗

Commissioning Validation of CLAS-12 Torus Magnet Protection and Cryogenic Safety System

This paper provides an overview of the CLAS12 Torus magnet electromagnetic loss and energy balance in the magnet system and impact on the cryogenics system during an event of a fast dump and quench, as part of the commissioning activities within Hall B for the 12 GeV Accelerator Upgrade project at Jefferson Lab in November 2016. Test carried out validates the design of torus magnet protection and cryogenic safety system. This magnet is unique in that it comprises 6 superconducting coils which are individually conduction-cooled by helium, thereby providing an element of thermal and mechanical decoupling between the coils. Lastly, as such its behavior under a fast dump condition (and even a quench) is markedly different from that of more conventional bath-cooled superconducting magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Mapping of the CLAS12 Torus - A Comparative Study between the Engineering Model and Measurements at JLab

This study provides an overview of the magnetic field measurement and subsequent electromagnetic re-modeling of the CLAS12 torus during the commissioning of the magnet in the fall of 2016. The CLAS12 detector in Hall B is part of the 12 GeV Accelerator Upgrade project at Jefferson Lab. The torus magnet allows precise determination of particle momenta in the forward direction (~ 5 0 x 4 0 ) in the forward direction. The ability to do this requires we know the fB.dl of the torus to within an accuracy of 0.5 % or better. To achieve this, an accurate model of the field along the particle paths is required. The TOSCA code is used to generate a full 3D simulation of the magnetic envelope of the magnet as designed. Experimentally the actual magnetic field within the magnet was surveyed to confirm the model design and to measure the deviation from the ideal case. The magnetic field deviations are attributed to manufacturing variability and assembly tolerances. A final model was created with allowances for these deviations guided by the survey data to create a more precise field integral model which greatly improves momentum resolution capability allowing it to deliver the required specifications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of an Interaction Region Quadrupole Magnet for a Future Electron-Ion Collider at JLab

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 11 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 10 34 cm -2 sec -1 . The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The lattice file for the machine has changed to accommodate the higher energy; this change requires all the magnets in the interaction region to change. This paper will describe the requirements for both the ion and electron beam superconducting magnets around the interaction point. All the Final Focusing Quadrupole (FFQ) magnets now have preliminary designs. This paper will describe the optimization process for one of these FFQs. The optimization is performed using the optimization module of SIMULIA Opera FEA and compared with ROXIE. An analytical design tool has also been developed to estimate the peak field in the coils. The quadrupole has been optimized for peak field in the coils, and magnetic length.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems related to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature

Here, the aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the measurement of a lepton–lepton electroweak reaction (MOLLER) experiment in experimental Hall A at Jefferson Lab, Newport News, VA. In this article, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the short-beam shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils, tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well-suited for electrical insulation of MOLLER magnets.

36 MATERIALS SCIENCE↗

Nonevaporable getter coating chambers for extreme high vacuum

Techniques for NEG coating a large diameter chamber are presented along with vacuum measurements in the chamber using several pumping configurations, with base pressure as low as 1.56x10^-12 Torr (N2 equivalent) with only a NEG coating and small ion pump. We then describe modifications to the NEG coating process to coat complex geometry chambers for ultra-cold atom trap experiments. Surface analysis of NEG coated samples are used to measure composition and morphology of the thin films. Finally, pressure measurements are compared for two NEG coated polarized electron source chambers: the 130 kV polarized electron source at Jefferson Lab and the upgraded 350 kV polarized 2 electron source, both of which are approaching or within the extreme high vacuum (XHV) range, defined as P<7.5x10^-13 Torr.

47 OTHER INSTRUMENTATION↗

SU-GG-T-49: Real Time Dose Verification for Novel Shielded Balloon Brachytherapy

Purpose: The validation of a novel approach for reducing skindoses to an acceptable level during Accelerated Partial Breast Irradiation (APBI) when the balloon-to-skin distance is inadequate (less than 7 mm) is reported. The study uses a real time dose verification method for a metallic shielded balloon applicator using scintillation fiber technology. Method and Materials: Partial shielding of the radiationdose to the skin using iron or other ferrous powder could enable the extension of APBI to some patients. With small external and pre-determined magnetic fields (<few Gauss), the metallic elements deposition can be controlled on the inner surface of a balloon. Geant4 simulations were used to generate an attenuation dose curve for various radiation lengths after cross-calibration with dedicated data acquired at Jefferson Lab. Some powder was then injected into various inflated MammoSite and rectal balloons within realistic breast and torso phantoms of differing sizes. The dose on the external surface of the skin was measured from a 6.1 Ci {sup 192}Ir of a GammaMed 12i afterloader unit, with a MOSFET,ion chamber and scintillating fiber array detectors. Results: Realistic Monte Carlo simulation studies for the amount and distribution of the required shielding material were compared to dedicated phantom data. A decrease of the skindose was measured to an acceptable level (~350-450 cGy) during standard breast Brachytherapy treatments with relatively weak magnetic fields. Additional measurements provided negligible corrections (< few %) on the saline water density from the suspended ironpowder.Conclusion: This project opens the possibility to increasing the survival expectancy and minimizing negative side effects during brachytherapy treatments, as well as improving cosmetic outcome for all APBI patients. The proposed method may also be used in other procedures for brain, heart, rectal, or vaginal cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Source-size measurements in the e 3 He( 4 He) → e'pΛX reaction

We report preliminary data on proton-lambda correlations at small relative momentum q in the e 3 He( 4 He) → e'pΛX reaction at E 0 = 4.7(4.46) GeV using the CLAS detector at Jefferson Lab. The enhancement of the correlation function at small q was found to be in qualitative agreement with theoretical expectations. The size of emission region about 1.5 fm was estimated using Lednický-Lyuboshitz analytical model. The experimental correlation function is comparable with the P-matrix fit of the hyperon-nucleon data. Small-relative-momentum-proton-lambda correlations both for 3 He( 4 He) target and for electroproduction reaction were studied for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radiative Møller scattering involving polarized particles

A method for taking into account radiative events in experiments aimed at studying Møller scattering with polarized particles was developed for an arbitrary implementation of such experiments. A computer code used to perform a numerical analysis with allowance for the kinematical conditions of the MOLLER experiment at the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab) was constructed. The respective results were compared with their counterparts obtained in the soft-photon approximation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QCD analysis of the Bjorken sum rule revisited

We present extended analysis of the polarized Bjorken sum rule using the four-loop expression for the coefficient function C{sub Bj}(α{sub s}) available now and the recent low Q{sup 2}-data from the Jefferson Lab and COMPASS experiments. We demonstrate that the perturbative series for the function C{sub Bj} gives a hint to its asymptotic nature manifesting itself in the region Q{sup 2} ≲ 1 GeV{sup 2}. It is confirmed by the considered integral model for the perturbative QCD correction. We analyze values of higher-twist terms extracted from the mentioned data and discuss the interplay between higher orders perturbative and higher-twist contributions. We extend our consideration to the Gross-Llewellyn Smith sum rule and investigate the relation between higher twist coefficients in these two sum rules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗