Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Algorithms for detection of objects in image sequences captured from an airborne imaging system

This research was initiated as a part of the effort at the NASA Ames Research Center to design a computer vision based system that can enhance the safety of navigation by aiding the pilots in detecting various obstacles on the runway during critical section of the flight such as a landing maneuver. The primary goal is the development of algorithms for detection of moving objects from a sequence of images obtained from an on-board video camera. Image regions corresponding to the independently moving objects are segmented from the background by applying constraint filtering on the optical flow computed from the initial few frames of the sequence. These detected regions are tracked over subsequent frames using a model based tracking algorithm. Position and velocity of the moving objects in the world coordinate is estimated using an extended Kalman filter. The algorithms are tested using the NASA line image sequence with six static trucks and a simulated moving truck and experimental results are described. Various limitations of the currently implemented version of the above algorithm are identified and possible solutions to build a practical working system are investigated.

Kasturi, Rangachar↗

Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainty-aware particle segmentation for electron microscopy at varied length scales

Electron microscopy is indispensable for examining the morphology and composition of solid materials at the sub-micron scale. To study the powder samples that are widely used in materials development, scanning electron microscopes (SEMs) are increasingly used at the laboratory scale to generate large datasets with hundreds of images. Parsing these images to identify distinct particles and determine their morphology requires careful analysis, and automating this process remains challenging. In this work, we enhance the Mask R-CNN architecture to develop a method for automated segmentation of particles in SEM images. We address several challenges inherent to measurements, such as image blur and particle agglomeration. Moreover, our method accounts for prediction uncertainty when such issues prevent accurate segmentation of a particle. Recognizing that disparate length scales are often present in large datasets, we use this framework to create two models that are separately trained to handle images obtained at low or high magnification. By testing these models on a variety of inorganic samples, our approach to particle segmentation surpasses an established automated segmentation method and yields comparable results to the predictions of three domain experts, revealing comparable accuracy while requiring a fraction of the time. These findings highlight the potential of deep learning in advancing autonomous workflows for materials characterization.

36 MATERIALS SCIENCE↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

Next Generation Geostationary Operational Environmental Satellite (GOES-R Series): A Space Segment Overview

The next-generation National Oceanic and Atmospheric Administration (NOAA) Geostationary Operational Environmental Satellite (GOES-R series) is currently being developed by NOAA in cooperation with the National Aeronautics and Space Administration (NASA). The GOES-R series satellites represents a significant improvement in spatial, temporal, and spectral observations (several orders of magnitude) over the capabilities of the currently operational GOES-1 series and the about to be launched GOES-N series satellite. The GOES-R series will incorporate technically advanced third-generation instruments and spacecraft enhancements to meet evolving observational requirements of forecasting for the era 2012-2025. The GOES-R instrument complement being developed includes a Advanced Baseline Imager (ABI), a Hyperspectral Environmental Suite (HES), a GEO Lighting Mapper (GLM), a Solar Imaging Suite (SIS) and a Space Environment In-Situ Suite (SEISS). Also, candidates for a number of GOES-R Pre-Planned Product Improvements (P(sup 3)Is) includes a Geo microwave Sounder, a Coronograph, a Hyperspectral Imager, and a Solar Irradiance Sensor. Currently, the GOES-R Space Segment architecture is being evaluated as part of a GOES-R system end-to-end architecture study. The GOES-R notional baseline architecture is a constellation of two satellites (A-sat and B-sat) each nominally located at 75 degrees west longitude and at 135 degrees west longitude at geostationary altitude, 0 degrees inclination. The primary mission of the A-sat is to provide imaging from the ABI. The A-sat will also contain the SIS and the GLM. The primary mission of the B-sat is to provide sounding of the hemispherical disk of the earth from the HES. The B-sat also contains the SEISS. Both satellites have mesoscale capabilities for severe weather sounding or imaging. This paper overviews the GOES-R Space Segment development including satellite constellation trade-off, improvements and differences between the current and future instrument and spacecraft capabilities, and technology infusion.

Krimchansky, Alexander↗

Open Data and Deep Semantic Segmentation for Automated Extraction of Building Footprints

Advances in machine learning and computer vision, combined with increased access to unstructured data (e.g., images and text), have created an opportunity for automated extraction of building characteristics, cost-effectively, and at scale. These characteristics are relevant to a variety of urban and energy applications, yet are time consuming and costly to acquire with today’s manual methods. Several recent research studies have shown that in comparison to more traditional methods that are based on features engineering approach, an end-to-end learning approach based on deep learning algorithms significantly improved the accuracy of automatic building footprint extraction from remote sensing images. However, these studies used limited benchmark datasets that have been carefully curated and labeled. How the accuracy of these deep learning-based approach holds when using less curated training data has not received enough attention. The aim of this work is to leverage the openly available data to automatically generate a larger training dataset with more variability in term of regions and type of cities, which can be used to build more accurate deep learning models. In contrast to most benchmark datasets, the gathered data have not been manually curated. Thus, the training dataset is not perfectly clean in terms of remote sensing images exactly matching the ground truth building’s foot-print. A workflow that includes data pre-processing, deep learning semantic segmentation modeling, and results post-processing is introduced and applied to a dataset that include remote sensing images from 15 cities and five counties from various region of the USA, which include 8,607,677 buildings. The accuracy of the proposed approach was measured on an out of sample testing dataset corresponding to 364,000 buildings from three USA cities. The results favorably compared to those obtained from Microsoft’s recently released US building footprint dataset.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-67: Evaluation of Adaptive MLC Morphing for Online Correction of Prostate Cancer Radiotherapy

Purpose: Online adaptive MLC morphing is desirable over translational couch shifts to accommodate target position as well as anatomic changes. A reliable method of adaptive MLC segment to target during prostate cancer IMRT treatment is proposed and evaluated by comparison with daily online-image guidance (IGRT) correction and online-IMRT planning. Methods: The MLC adaptive algorithm involves following steps; move the MLC segments according to target translational shifts, and then morph the segment shape to maintain the spatial relationship between the planning-target contour and MLC segment. Efficacy of this method was evaluated retrospectively using daily-CBCT images on seven prostate patients treated with seven-beam IMRT treatment to deliver 64Gy in 20 fractions. Daily modification was simulated with three approaches; daily-IGRT correction based on implanted radio-markers, adaptive MLC morphing, and online-IMRT planning, with no-residual variation. The selected dosimetric endpoints and nEUD (normalized equivalent uniform dose to online-IMRT planning) of each organ of interest were determined for evaluation and comparison. Results: For target(prostate), bladder and rectal-wall, the mean±sd of nEUD were 97.6%+3.2%, 103.9%±4.9% and 97.4%±1.1% for daily-IGRT correction; and 100.2%+0.2%, 108.9%±5.1% and 99.8%±1.2% for adaptive MLC morphing, respectively. For daily-IGRT correction, adaptive MLC morphing and online-IMRT planning, target D99 was <95% of the prescription dose in 30%, 0% and 0% of 140 fractions, respectively. For the rectal-wall, D5 exceeded 105% of the planned-D5 in 2.8%, 11.4% and 0% of 140 fractions, respectively. For the bladder, Dmax exceeded 105% of the planned-D5 in 2.8%, 5.6% and 0% of 140 fractions, respectively. D30 of bladder and rectal-wall were well within the planned-D30 for all three approaches. Conclusion: The proposed method of adaptive MLC morphing can be beneficial for the prostate patient population with large deformation and rotation. It is superior to the daily-IGRT correction, and comparable to the online-IMRT planning for dose to the target and rectal-wall.

60 APPLIED LIFE SCIENCES↗

Effects of diffraction and static wavefront errors on high-contrast imaging from the Thirty Meter Telescope

High-contrast imaging, particularly direct detection of extrasolar planets, is a major science driver for the next generation of extremely large telescopes such as the segmented Thirty Meter Telescope. This goal requires more than merely diffraction-limited imaging, but also attention to residual scattered light from wavefront errors and diffraction effects at the contrast level of 10-8-10-9. Using a wave-optics simulation of adaptive optics and a diffraction suppression system we investigate diffraction from the segmentation geometry, intersegment gaps, obscuration by the secondary mirror and its supports. We find that the large obscurations pose a greater challenge than the much smaller segment gaps. In addition the impact of wavefront errors from the primary mirror, including segment alignment and figure errors, are analyzed. Segment-to-segment reflectivity variations and residual segment figure error will be the dominant error contributors from the primary mirror. Strategies to mitigate these errors are discussed.

segmented mirrors↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Leveraging unlabeled SEM datasets with self-supervised learning for enhanced particle segmentation

Scanning Electron Microscopes (SEMs) are widely used in experimental science laboratories, often requiring cumbersome and repetitive user analysis. Automating SEM image analysis processes is highly desirable to address this challenge. In particle sample analysis, Machine Learning (ML) has emerged as the most effective approach for particle segmentation. However, the time-intensive process of manually annotating thousands of SEM images limits the applicability of supervised learning approaches. Self-Supervised Learning (SSL) offers a promising alternative by enabling knowledge extraction from raw, unlabeled data. This study presents a framework for evaluating SSL techniques in SEM image analysis, focusing on novel methods leveraging the ConvNeXtV2 architecture for particle detection. A dataset comprising 25,000 SEM images is curated to benchmark these proposed SSL methods. The results demonstrate that ConvNeXtV2 models, with varying parameter counts, consistently outperform other techniques in particle detection across different length scales, achieving up to a 34% reduction in relative error compared to established SSL methods. Furthermore, an ablation study explores the relationship between dataset size and SSL performance, providing actionable insights for practitioners regarding model selection and resource efficiency. This research advances the integration of SSL into autonomous analysis pipelines and supports its application in accelerating materials science discovery.

Rettenberger, Luca↗

SU-F-T-41: 3D MTP-TRUS for Prostate Implant

Purpose: Prostate brachytherapy is an effective treatment for early prostate cancer. The current prostate implant is limited to using 2D transrectal ultrassound (TRUS) or machenical motor driven 2D array either in the end or on the side. Real-time 3D images can improve the accuracy of the guidance of prostate implant. The concept of our system is to allow realtime full visualization of the entire prostate with the multiple transverse scan. Methods: The prototype of 3D Multiple-Transverse-Plane Transrectal Ultrasound probe (MTP-TRUS) has been designed by us and manufactured by Blatek inc. It has 7 convex linear arrays and each array has 96 elements. It is connected to cQuest Fire bird research system (Cephasonics inc.) which is a flexible and configurable ultrasound-development platform. The size of cQuest Firebird system is compact and supports the real-time wireless image transferring. A relay based mux board is designed for the cQuest Firebird system to be able to connect 672 elements. Results: The center frequency of probe is 6MHz±10%. The diameter of probe is 3cm and the length is 20cm. The element pitch is 0.205 mm. Array focus is 30mm and spacing 1.6cm. The beam data for each array was measured and met our expectation. The interface board of MTP-TURS is made and able to connect to cQuest Firebird system. The image display interface is still under the development. Our real-time needle tracking algorithm will be implemented too. Conclusion: Our MTP-TRUS system for prostate implant will be able to acquire real-time 3D images of prostate and do the real-time needle segmentation and tracking. The system is compact and have wireless function.

60 APPLIED LIFE SCIENCES↗

A deep learning model for automatic analysis of cavities in irradiated materials

Transmission electron microscopy (TEM) is a commonly used technique in materials science for defect investigation. Quantitative analysis of defects is important for understanding the properties of a material, but manual analysis of TEM micrographs can be time-consuming and prone to error, especially when the defects have irregular shapes rather than spherical shapes. Many existing methods or deep learning models do not handle a wide range of sizes for the same object type within a single image. In this work, we present a framework that enables users to train an instance segmentation model called Mask R- CNN on any microstructure dataset, perform multi-detection on the same image at different scales, and obtain properties (e.g., size, area) of the objects based on the desired shape (e.g., circle, ellipse, rectangle). Additionally, we have developed a parallel detection module that uses multiple GPUs to increase the efficiency of the object detection process. We demonstrate the capabilities of our framework using a set of TEM images of cavities with different shapes, size distributions, and background contrasts. Finally, we show that the performance of our model in terms of density, size, and swelling of the cavities is comparable to the human average and that our model achieves the highest recall value compared to existing methods due to the use of image multi-rescaling.

36 MATERIALS SCIENCE↗

TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-18C-06: Prospective Patient Evaluation of Iterative Reconstruction in Radiation Oncology

Purpose: This work incorporates iterative reconstruction (IR) into a dose reduction study to characterize image quality metrics, delineation, and dosimetric assessment, with the goal of reducing imaging dose in Radiation Oncology. Methods: Three-dimensional noise power spectrum (NPS) analysis characterized noise magnitude/texture (120 kVp, 50–200 mAs, IR levels 1–6 yielding noise reduction of 0.89–0.55 compared to filtered backprojection (FBP)). Task-specific Modulation Transfer Functions (MTFtask) were characterized across varied subject contrasts. A prospective dose reduction study (500 to 150 mAs) was conducted for 12 patients (43 inter-fraction CTs) for high-dose rate brachytherapy. Three physicians performed qualitative image assessment between full-dose FBP (FD-FBP, 500 mAs), low-dose FBP (LD-FBP, 150–250 mAs), and low-dose IRL5-6 (LD-IR) scans for image noise, cuff/bladder interface detectability, spatial resolution, texture, and segmentation confidence. Comparisons between LD-FBP and LD-IR were conducted for the following metrics: delineation (bladder and rectum evaluated via overlap indices (OI) and Dice similarity coefficients (DSC)), noise, boundary changes, dose calculation, and digitally reconstructed radiographs (DRRs). Results: NPS showed ∼50% reduction in noise magnitude and ∼0.1 1/mm spatial frequency shift with IRL6. The largest MTFtask decrease between FBP and IR was 0.08 A.U. Qualitative patient image evaluation revealed LD-IR was equivalent or slightly worse than FD-FBP, and superior to LD-FBP for all metrics except low contrast interface and texture. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using IRL6 (−1.2 ± 4.9 HU (range: −17.6 – 12.5 HU)). No significant contour differences (OIs and DSCs = 0.85 – 0.95) and dose calculation discrepancy (<0.02%) were observed. DRRs preserved anatomical detail and demonstrated <2% difference in intensity between LD-FBP and LD-IRL6. Conclusion: While phantom analysis showed slight noise texture differences with IR, patient results revealed that image quality, contouring ability, and dosimetric parameters were not adversely affected, thus support integrating IR into treatment planning. Research supported in part by a grant from Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-05: [18F]NaF PET/CT Imaging Biomarkers in Metastatic Prostate Cancer

Purpose: Clinical use of {sup 18}F-Sodium Fluoride (NaF) PET/CT in metastatic settings often lacks technology to quantitatively measure full disease dynamics due to high tumor burden. This study assesses radiomics-based extraction of NaF PET/CT measures, including global metrics of overall burden and local metrics of disease heterogeneity, in metastatic prostate cancer for correlation to clinical outcomes. Methods: Fifty-six metastatic Castrate-Resistant Prostate Cancer (mCRPC) patients had NaF PET/CT scans performed at baseline and three cycles into chemotherapy (N=16) or androgen-receptor (AR) inhibitors (N=39). A novel technology, Quantitative Total Bone Imaging (QTBI), was used for analysis. Employing hybrid PET/CT segmentation and articulated skeletal-registration, QTBI allows for response assessment of individual lesions. Various SUV metrics were extracted from each lesion (iSUV). Global metrics were extracted from composite lesion-level statistics for each patient (pSUV). Proportion of detected lesions and those with significant response (%-increase or %-decrease) was calculated for each patient based on test-retest limits for iSUV metrics. Cox proportional hazard regression analyses were conducted between imaging metrics and progression-free survival (PFS). Results: Functional burden (pSUV{sub total}) assessed mid-treatment was the strongest univariate predictor of PFS (HR=2.03; p<0.0001). Various global metrics outperformed baseline clinical markers, including fraction of skeletal burden, mean uptake (pSUV{sub mean}), and heterogeneity of average lesion uptake (pSUV{sub hetero}). Of 43 patients with paired baseline/mid-treatment imaging, 40 showed heterogeneity in lesion-level response, containing populations of lesions with both increasing/decreasing metrics. Proportion of lesions with significantly increasing iSUV{sub mean} was highly predictive of clinical PFS (HR=2.0; p=0.0002). Patients exhibiting higher proportion of lesions with decreasing iSUV{sub total} saw prolonged radiographic PFS (HR=0.51; p=0.02). Conclusion: Technology presented here provides comprehensive disease quantification on NaF PET/CT imaging, showing strong correlation to clinical outcomes. Total functional burden as well as proportions of similarly responding lesions was predictive of PFS. This supports ongoing development of NaF PET/CT based imaging biomarkers in mCRPC. Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Incremental growth of short SWNT arrays by pulsed chemical vapor deposition

Very short, aligned arrays of continuous single wall carbon nanotubes were grown incrementally in steps as small as 25 nm using pulsed chemical vapor deposition. In situ optical extinction measurements indicate that over 98% of the nanotubes reinitiate growth on successive gas pulses, and HRTEM images show that the SWNTs do not exhibit segments, caps, or noticeable sidewall defects resulting from repeatedly stopping and restarting growth. Time-resolved laser reflectivity (3-ms temporal resolution) was used to record the nucleation and growth kinetics for each fast (0.2 second) gas pulse and measure the height increase of the array in situ, providing a "digital" method to incrementally grow short nanotube arrays to precise heights. Derivatives of the optical reflectivity signal reveal distinct temporal signatures for both nucleation and growth kinetics, with their amplitude ratio on the first gas pulse serving as a good predictor for aligned vs. unaligned growth. Incremental growth by pulsed CVD is interpreted in the context of autocatalytic kinetic models as a special processing window in which a sufficiently high flux of feedstock gas drives the nucleation and rapid growth phases of a catalyst nanoparticle ensemble to occur within the temporal period of the gas pulse, but without inducing growth termination.

36 MATERIALS SCIENCE↗

Electric field enhanced diffusion welding of alloy 617: Microstructural characteristics and mechanical properties

This study investigated the microstructural characteristics and mechanical behavior of diffusion welded nickel-based Alloy 617 obtained by electric field-assisted sintering (EFAS) using various parameters. The interfacial microstructure exhibited different characteristics including good grain boundary (GB) migration across the interface in the samples diffusion-welded at 1100 °C and a flat interface in the samples joined at 1000 °C and 1050 °C. The interface consisted of fine Al 2 O 3 oxides, while precipitation of interfacial M 23 C 6 carbides was not observed. Grain boundaries migrated across the Al 2 O 3 oxides, leaving these oxides within the grains. Graded grain size was observed, with grain coarsening being more significant near the sample surface due to the temperature gradient induced by EFAS. Tensile testing revealed that the specimens fractured in the matrix away from the interface, indicting strong diffusion-welded joints. Further, the peak tensile strength of 807 MPa was obtained in the samples welded at 1000 °C due to minimal grain growth. The materials obtained at 1100 °C exhibited reduced tensile strength but improved ductility. Strain maps revealed by digital image correlation showed alternating high and low strain segments in the samples produced at 1000 °C and 1050 °C, indicating that the flat interfaces with no GB migration were less ductile compared to the matrix. A greater strain uniformity was observed along the bond interfaces with improved GB migration. The hardness reduced near the sample surfaces due to enlarged grains induced by temperature gradient. This study demonstrates that GB migration and enhanced mechanical strength can be achieved in diffusion-welded Alloy 617.

36 MATERIALS SCIENCE↗

Measuring thermal curing induced shrinkage of material extrusion based additive manufacturing silicone elastomer lattices by X-ray computed tomography

Thermal curing induces shrinkage in material extrusion based additive manufacturing silicone elastomer samples, resulting in discrepancies between as printed and final geometries. Knowing the extent to which the samples change in shape and size allows us to make appropriate modifications to the printing design to better control the geometry of the samples. We present an X-ray computed tomography (CT) based approach to determine filament-level shrinkage due to thermal curing of silicone elastomer samples printed with direct ink writing (DIW). The approach relies on custom-designed build plates that are resistant to the elevated curing temperatures and that have sufficiently distinct X-ray absorption characteristics from the silicone elastomer to ensure adequate segmentation of the latter in X-ray imaging data. We implement the approach to evaluate shrinkage in DIW ‘log pile’ samples with three distinct strand arrangements and demonstrate of how filament-level information can be extracted from the X-ray CT data.

Additive manufacturing↗