Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Quantifying Message Aggregation Optimisations for Energy Savings in PGAS Models

Upon breaking past the exascale barrier, HPC systems are facing their greatest challenge yet - a power wall that must be addressed through new methods in both hardware and software. While energy costs are becoming a major issue at all levels, of particular concern is that of the network, as the relative cost of moving data is increasing faster than ever. The partitioned global address space (PGAS) model is critical within certain HPC domains, but is known to suffer from the small message problem, where irregular many-to-many access patterns result in congesting the network with excessive numbers of small messages. To address this, the conveyor aggregation library was developed to defer individual messages and group them for subsequent bulk processing. In this paper, we investigate its impact on energy use related to the network, with a focus on the Slingshot 11 interconnect. We will demonstrate that this strategy is not only highly performant, but also crucial to reducing energy footprints to remain within target power envelopes.

Welch, Aaron [ORNL]↗

Addressing Electric Aviation Infrastructure Cybersecurity Implementation

This technical report evaluates key considerations of cybersecurity systems in preparation for the electrification of both legacy and new aviation services. The objectives are to consider the landscape of components and interconnections, review sensitivities and the criticality of data and operations, and aim to understand the applicability of existing best practices or the need for new ones associated with the cybersecurity of electric charging systems for the aviation sector. Given the early stages of electric aviation deployment, developers have the opportunity to plan and integrate cybersecurity strategies into the complete electric aviation system during the initial stages of design and procurement and will benefit from employing a framework for continuous cybersecurity monitoring. This paper presents initial considerations of key cybersecurity strategies and their application to forthcoming electric aviation systems.

airports↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generative Design for Resilience of Interdependent Network Systems

Abstract Interconnected complex systems usually undergo disruptions due to internal uncertainties and external negative impacts such as those caused by harsh operating environments or regional natural disaster events. To maintain the operation of interconnected network systems under both internal and external challenges, design for resilience research has been conducted from both enhancing the reliability of the system through better designs and improving the failure recovery capabilities. As for enhancing the designs, challenges have arisen for designing a robust system due to the increasing scale of modern systems and the complicated underlying physical constraints. To tackle these challenges and design a resilient system efficiently, this study presents a generative design method that utilizes graph learning algorithms. The generative design framework contains a performance estimator and a candidate design generator. The generator can intelligently mine good properties from existing systems and output new designs that meet predefined performance criteria while the estimator can efficiently predict the performance of the generated design for a fast iterative learning process. Case studies results based on synthetic supply chain networks and power systems from the IEEE dataset have illustrated the applicability of the developed method for designing resilient interdependent network systems.

Engineering↗

SynchroPhasor Measurements: System Architecture and Performance Evaluation in Supporting Wide-Area Applications

The infrastructure of phasor measurements have evolved over the last two decades from isolated measurement units to networked measurement systems with footprints beyond individual utility companies. This is, to a great extent, a bottom-up self-evolving process except some local systems built by design. Given the number of phasor measurement units (PMUs) in the system is small (currently 70 each in western and eastern interconnections), current phasor network architecture works just fine. However, the architecture will become a bottleneck when large number of PMUs are installed (e.g. >1000~10000). The need for phasor architecture design has yet to be addressed. This paper reviews the current phasor networks and investigates future architectures, as related to the efforts undertaken by the North America SynchroPhasor Initiative (NASPI). Then it continues to present staged system tests to evaluate the performance of phasor networks, which is a common practice in the Western Electricity Coordinating Council (WECC) system. This is followed by field measurement evaluation and the implication of phasor quality issues on phasor applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding DERMS

With the rapid deployment of distributed energy resources (DER), there is a high level of interest in how these devices can be integrated with utility operations at all levels for management and monitoring purposes. This integration is challenging in that the number of devices is high and that ownership is often that of a customer or third party. Industry stakeholders first began to address DER integration by identifying and standardizing the functions that individual DER can perform autonomously, a distributed manner. Device-level functions like “voltage ride-through”, “volt-var”, “frequency-watt”, and “dynamic reactive current” were designed and documented and are now supported by communication standards and grid codes worldwide, making grid-supportive capabilities mandatory for new interconnections. This was a first step. A necessary step, but not sufficient to achieve end-to-end integration of DER with the grid. A substantial gap was recognized between the granular controls of individual DER and the type of organized services needed for grid support, integration with distribution management systems (DMS) and grid operations. In 2012, stakeholders began working to define a common set of grid-supportive services and means to integrate large quantities of DERs into utility systems in a way that is practical, sustainable and extensible. Because multiple parties could be involved; utilities, DMS providers, DER aggregators and facility/microgrid controller providers are working together.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

High Penetration of Photovoltaic Generation Study – Flagstaff Community Power (Final Technical Report, Results of Phases 2-5)

APS’s renewable energy portfolio, driven in part by Arizona’s Renewable Energy Standard (RES) currently includes more than 1100 MW of installed capacity, equating to roughly 3000 GWh of annual production. Overall renewable production is expected to grow to 6000 GWh by 2025. It is expected that distributed photovoltaics, driven primarily by lower cost, will contribute to much of this growth and that by 2025, distributed installations will account for half of all renewable production (3000GHW). As solar penetration increases, additional analysis may be required for routine utility processes to ensure continued safe and reliable operation of the electric distribution network. Such processes include residential or commercial interconnection requests and load shifting during normal feeder operations. Circuits with existing high solar penetration will also have to be studied and results will need to be evaluated for adherence to utility practices or strategy. Increased distributed PV penetration may offer benefits such as load offsetting, but it also has the potential to adversely impact distribution system operation. These effects may be exacerbated by the rapid variability of PV production. Detailed effects of these phenomena in distributed PV applications continue to be studied. Comprehensive, high-resolution electrical models of the distribution system were developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. Modeling methods were refined by validating against field measurements. To augment the field measurements, methods were developed to synthesize high resolution load and PV generation data to facilitate quasi-static time series simulations. The models were then extended to explore boundary conditions for PV hosting capability of the feeder and to simulate common utility practices such as feeder reconfiguration. The modeling and analysis methodology was implemented using open source tools and a process was developed to aid utility engineers in future interconnection requests. Methods to increase PV hosting capacity were also explored during the course of the study. A 700kVA grid-supportive inverter was deployed on the feeder and each grid support mode was demonstrated. Energy storage was explored through simulation and models were developed to calculate the optimum size and placement needed to increase PV hosting capacity. A tool was developed to aid planners in assigning relative costs and benefits to various strategies for increasing PV hosting capacity beyond current levels. Following the completion of the project, APS intends to use the tools and methods to improve the framework of future PV integration on its system. The tools and methods are also expected to aid other utilities to accelerate distributed PV deployment.

14 SOLAR ENERGY↗

Optomechanical ring resonator for efficient microwave-optical frequency conversion

Phonons traveling in solid-state devices are emerging as a universal excitation for coupling different physical systems. Phonons at microwave frequencies have a similar wavelength to optical photons in solids, enabling optomechanical microwave-optical transduction of classical and quantum signals. It becomes conceivable to build optomechanical integrated circuits (OMIC) that guide both photons and phonons and interconnect photonic and phononic devices. Here, we demonstrate an OMIC including an optomechanical ring resonator (OMR), where co-resonant infrared photons and GHz phonons induce significantly enhanced interconversion. The platform is hybrid, using wide bandgap semiconductor gallium phosphide (GaP) for waveguiding and piezoelectric zinc oxide (ZnO) for phonon generation. The OMR features photonic and phononic quality factors of >1 × 10 5 and 3.2 × 10 3 , respectively. The optomechanical interconversion between photonic modes achieved an internal conversion efficiency $η_i$ = (2.1 ± 0.1)% and a total device efficiency $η_{tot}$ = 0.57 x 10 -6 at a low acoustic pump power of 1.6 mW. The efficient conversion in OMICs enables microwave-optical transduction for quantum information and microwave photonics applications.

42 ENGINEERING↗

Creation of System Validation Platform

The objective of this CRADA between Sandia National Laboratories (SNL) and SunSpec Alliance (SunSpec) was to create a software test platform called the System Validation Platform (SVP) that performs end-to-end certification testing of photovoltaic (PV) inverters, energy storage systems, and other distributed energy resources (DERs). The SVP automates interactions of test equipment (PV and grid simulators), data acquisition systems, and interoperable DERs to certify the devices for advanced grid-support functions and interoperability. To assist electricity grid, operators maintain voltage and frequency, new interconnection requirements in the U.S. and Europe require DERs to have grid-support functions with adjustable settings. Automating the certification process for DER devices impacts the bottom line of NRTLs because they do not need to rely on test engineers running days (or weeks) of experiments to validate the performance of the equipment. These savings can then be passed down to the DER vendors so the certification process becomes less expensive and lowers the barrier to market for PV inverters, charge controllers, and other grid-interconnected equipment. This technology can also be used as a research platform for SNL, other national labs, and universities that would like to run hardware tests with power electronics equipment.

14 SOLAR ENERGY↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Relevance of Generation Interconnection Procedures to Feed-in Tariffs in the United States

Feed-in tariffs (FITs) have been used to promote renewable electricity development in over 40 countries throughout the past two decades. These policies generally provide guaranteed prices for the full system output from eligible generators for a fixed time period (typically 15-20 years). Due in part to the success of FIT policies in Europe, some jurisdictions in the United States are consideringimplementing similar policies, and a few have already put such policies in place. This report is intended to offer some guidance to policymakers and regulators on how generator interconnection procedures may affect the implementation of FITs and how state generator interconnection procedures can be formulated to support state renewable energy objectives. This report is based on a literaturereview of model interconnection procedures formulated by several organizations, as well as other documents that have reviewed, commented on, and in some cases, ranked state interconnection procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variance Analysis of Wind and Natural Gas Generation under Different Market Structures: Some Observations

An important area of current research is whether large-scale penetration of variable renewable generation such as wind and solar power pose economic and operational burdens on the electricity system. In such scenarios, this issue has also raised considerable interest in the potential role and value of electricity storage as a method of mitigating variability in generation associated with the inherently variable nature of these forms of generation. At the same time, a number of studies have pointed to the potential benefits of renewable generation as a hedge against the volatility and potential escalation of fossil fuel prices. Prior research and this work suggest that the lack of correlation of renewable energy costs with fossil fuel prices means that adding large amounts of wind or solar generation may also reduce the volatility of system-wide electricity costs. Such variance reduction in overall system costs may be of significant value to consumers due to risk aversion. In contrast to this observation, other studies have focused on returns in restructured markets and noted that, in deregulated markets, baseload natural gas power generation may be relatively more attractive to investors because-unlike wind generation-peak power prices are often strongly correlated to natural gas prices. The analysis in this report recognizes that the potential value of risk mitigation associated with wind generation and natural gas generation may depend on whether one considers the consumer's perspective or the investor's perspective and whether the market is regulated or deregulated. We analyze the risk and return trade-offs for wind and natural gas generation for deregulated markets based on hourly prices and load over a 10-year period using historical data in the PJM Interconnection (PJM)2 from 1999 to 2008. Similar analysis is then simulated and evaluated for regulated markets under certain assumptions. Estimating the absolute value, as opposed to the relative value, of variance reduction will also depend on assumptions about risk aversion and other consumer preferences, such as loss aversion, and this is discussed.

03 NATURAL GAS↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis and Considerations for PV Interconnection Standards in the United States and China

The main objectives of this report are to evaluate China's photovoltaic (PV) interconnection standards and the U.S. counterparts and to propose recommendations for future revisions to these standards. This report references the 2013 report Comparative Study of Standards for Grid-Connected PV System in China, the U.S. and European Countries, which compares U.S., European, and China's PV grid interconnection standards; reviews various metrics for the characterization of distribution network with PV; and suggests modifications to China's PV interconnection standards and requirements. The recommendations are accompanied by assessments of four high-penetration PV grid interconnection cases in the United States to illustrate solutions implemented to resolve issues encountered at different sites. PV penetration in China and in the United States has significantly increased during the past several years, presenting comparable challenges depending on the conditions of the grid at the point of interconnection; solutions are generally unique to each interconnected PV installation or PV plant.

14 SOLAR ENERGY↗

Update on ORNL TRANSFORM Tool: Simulating Multi-Module Advanced Reactor with End-to-End I&C

The Small Modular Reactor (SMR) Dynamic System Modeling Tool project is in the fourth year of development. The project is designed to support collaborative modeling and study of various advanced SMR (non-light water cooled reactor) concepts, including the use of multiple coupled reactors at a single site. The focus of this report is the development of a steam generator and drum system model that includes the complex dynamics of typical steam drum systems, the development of instrumentation and controls for the steam generator with drum system model, and the development of multi-reactor module models that reflect the full power reactor innovative small module design concept. The objective of the project is to provide a common simulation environment and baseline modeling resources to facilitate rapid development of dynamic advanced reactor models; ensure consistency among research products within the Instrumentation, Controls, and Human-Machine Interface technical area; and leverage cross-cutting capabilities while minimizing duplication of effort. The combined simulation environment and suite of models are identified as the TRANSFORM tool. The critical elements of this effort include (1) defining a standardized, common simulation environment that can be applied throughout the Advanced Reactors Technology program; (2) developing a library of baseline component modules that can be assembled into full plant models using available geometry, design, and thermal-hydraulic data; (3) defining modeling conventions for interconnecting component models; and (4) establishing user interfaces and support tools to facilitate simulation development (i.e., configuration and parameterization), execution, and results display and capture.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Light funnel concentrator panel for solar power

The solar concentrator design concept provides a theoretical concentration efficiency of 96 percent with power-to-weight ratios as high as 50 W/kg. Further, it eliminates the need for fragile reflective coatings and is very tolerant to pointing inaccuracies. The concept differs from conventional reflective mirrors and lens design in that is uses the principle of total internal reflection in order to funnel incident sunlight into a concentrator photovoltaic cell. The feasibility of the light funnel concentrator concept was determined through a balanced approach of analysis, development, and fabrication of prototypes, and testing of components. A three-dimensional optical model of the light funnel concentrator and photovoltaic cell was developed in order to assess the ultimate performance of such systems. In addition, a thermal and structural analysis of a typical unit was made. Techniques of fabricating the light funnel cones, optically coupling them to GaAs concentrator cells, bonding the funnels to GaAs cells, making electrical interconnects, and bonding substrates was explored and a prototype light funnel concentrator unit was fabricated and tested. Testing of the system included measurements of optical concentrating efficiency, optical concentrator to cell coupling efficiency, and electrical efficiency.

Source record↗