Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

Lightweight electrically-powered flexible thermal laminate

Cross-layered woven or unwoven yarns are used to provide an active thermal control mechanism for spacecraft use. One set of yarns is composed of flexible electrically conductive metal fibers which are capable of being resistance heated by the application of voltage. Another set of yarns, nonconductive and flexible, provides mechanical strength and precludes the passage of electrical current between the metal yarns by virtue of the spacing between them. A lightweight, electrically nonconductive film is bonded to the cross-layered yarns to protect the metal yarns from the elements (minimize electrical shorts from moisture such as rain), to provide additional strength to the fabric, and to prevent conductive loss of heat in nonvacuum applications. The nonconductive film is metalized on its obverse side to provide a more uniform heat load distribution.

Dawn, F. S.↗

Analytical evaluation of the impact of broad specification fuels on high bypass turbofan engine combustors

The impact of the use of broad specification fuels on the design, performance durability, emissions and operational characteristics of combustors for commercial aircraft gas turbine engines was assessed. Single stage, vorbix and lean premixed prevaporized combustors, in the JT9D and an advanced energy efficient engine cycle were evaluated when operating on Jet A and ERBS (Experimental Referee Broad Specification) fuels. Design modifications, based on criteria evolved from a literature survey, were introduced and their effectiveness at offsetting projected deficiencies resulting from the use of ERBS was estimated. The results indicate that the use of a broad specification fuel such as ERBS, will necessitate significant technology improvements and redesign if deteriorated performance, durability and emissions are to be avoided. Higher radiant heat loads are projected to seriously compromise liner life while the reduced thermal stability of ERBS will require revisions to the engine-airframe fuel system to reduce the thermal stress on the fuel. Smoke and emissions output are projected to increase with the use of broad specification fuels. While the basic geometry of the single stage and vorbix combustors are compatible with the use of ERBS, extensive redesign of the front end of the lean premixed prevaporized burner will be required to achieve satisfactory operation and optimum emissions.

Lohmann, R. P.↗

Space station thermal control surfaces

Mission planning documents were used to analyze the radiator design and thermal control surface requirements for both space station and 25-kW power module, to analyze the missions, and to determine the thermal control technology needed to satisfy both sets of requirements. Parameters such as thermal control coating degradation, vehicle attitude, self eclipsing, variation in solar constant, albedo, and Earth emission are considered. Four computer programs were developed which provide a preliminary design and evaluation tool for active radiator systems in LEO and GEO. Two programs were developed as general programs for space station analysis. Both types of programs find the radiator-flow solution and evaluate external heat loads in the same way. Fortran listings are included.

Maag, C. R.↗

Continuum Absorption Coefficient of Atoms and Ions

The rate of heat transfer to the heat shield of a Jupiter probe has been estimated to be one order of magnitude higher than any previously experienced in an outer space exploration program. More than one-third of this heat load is due to an emission of continuum radiation from atoms and ions. The existing computer code for calculating the continuum contribution to the total load utilizes a modified version of Biberman's approximate method. The continuum radiation absorption cross sections of a C - H - O - N ablation system were examined in detail. The present computer code was evaluated and updated by being compared with available exact and approximate calculations and correlations of experimental data. A detailed calculation procedure, which can be applied to other atomic species, is presented. The approximate correlations can be made to agree with the available exact and experimental data.

Armaly, B. F.↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

Conceptual study of a turbojet/ramjet inlet

An inlet concept for separate turbojet and ramjet engines was defined and compared with an equivalent inlet for a wraparound turboramjet engine. The comparison was made for a typical high altitude hypersonic cruise vehicle where the turbojet inlet capture area was required to be half as large as the ramjet inlet capture area at cruise. The use of a shorter nacelle having substantially lower cooling requirements at cruise for the inlet concept for separate turbojet and ramjet engines is suggested. The separate engine concept better isolates the turbojet from the ramjet, requires no special close off mechanisms within the turbojet, and avoids the circumferential heat load imposed by a wraparound ramjet. A more variable geometry is required.

Weidner, J. P.↗

Modeling of radiative heating of base region of Jovian entry probe

The mechanism of radiative heating of the afterbody region of Jovian entry probe is analyzed. A theoretical model is derived to determine the average thermodynamic properties in the expanding region, recirculating region, recompression region, and neck region through application of one-dimensional conservation equations. Flow parameters are obtained from the shadowgraphs of a free-flight test. Radiative transfer is calculated using spectrally detailed computer codes accounting for nonequilibrium. The results show that the most severe heating occurs immediately behind the frustum, and that the recompression and neck regions are the major sources of radiation that heats the base stagnation point. The radiation flux to the base point is slightly stronger with ablation than without, its value being 0.11(43Pb/Ps)squared times that to the front stagnation point, where Pb/Ps is the ratio of base-to-front stagnation point pressures and its value is in the range 0.023-0.066. The time-integrated heat load to the base point is 18(43Pb/Ps)squared kJ/sq cm. Existing experimental data are shown to agree with the theoretical prediction.

Park, C.↗

A solar-energy system in Minnesota

Report discusses system for Minnesota residence. Final design was arrived at that will meet 45 percent of total average heating load and will supply 40 gallons of potable ater at 140 deg F. Document contains detailed drawings, specifications, and cost tradeoff studies. Also included are outline of proposed installation, operation and maintenance manual, and analysis of hazards.

Source record↗

Solar heating for an electronics manufacturing plant--Blue Earth, Minnesota

Partial space heating for 97,000 square foot plant is supplied by 360 flat plate solar collectors; energy is sorted as heat in indoor 20,000 gallon water tank. System includes all necessary control electronics for year round operation. During December 1978, solar energy supplied 24.4 percent of building's space heating load.

Source record↗

Building with integral solar-heat storage--Starkville, Mississippi

Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.

Source record↗

Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR), phase 2

A cryogenic system to be utilized with a mounted pointing system is designed. The analysis indicates that the resulting design is significantly heavier than previous design due to the increased diameter of the system, resulting in greater tank and vacuum enclosure weights. Additional weight is also required in the area where the payload is attached to the pointing system in order to provide additional stiffness to the payload. The vacuum shell required to enclose the instrument is shorter and therefore an attendant reduction in instrument package weight would be expected. The primary resonance of the cooler instrument package occurs at 21 Hz, a mode in which the flexibility of the vacuum shell allows motion of the cryogen tank and instrument, and which can be increased by additional stiffening in the region of the pointing system vacuum shell connection at the cost of additional weight. The second resonance at 59 Hz is due to vibration of the helium tank on the fiberglass support tubes. The parasitic heat load can be reduced to 0.28 W by the utilization of a sandwich support tube structure in place of the monocoque structure assumed in the design.

Source record↗

Environmental control and life support system: Analysis of STS-1

The capability of the orbiter environmental control and life support system (ECLSS) to support vehicle cooling requirements in the event of cabin pressure reduction to 9 psia was evaluated, using the Orbiter versions of the shuttle environmental consumbles usage requirement evaluation (SECURE) program, and using heat load input data developed by the spacecraft electrical power simulator (SEPS) program. The SECURE model used in the analysis, the timeline and ECLSS configuration used in formulating the analysis, and the results of the analysis are presented. The conclusion which may be drawn drom these results. is summarized. There are no significant thermal problems with the proposed mission. There are, however, several procedures which could be optimized for better performance: setting the cabin HX air bypass and the interchanger water bypass to the zero flow position is of questionable efficacy; the cabin air pressure monitoring procedure should be re-evaluated; and the degree of equipment power down specified for this analysis and no problems were noted.

Steines, G.↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Solar space heating for the Visitors Center, Stephens College, Columbia, Missouri

The solar energy system located at the Visitors' Center on the Stephens College Campus, Columbia, Missouri is discussed. The system is installed in a four-story, 15,000 square foot building. The solar energy system is an integral design of the building and utilizes 176 hydronic flat plate collectors which use a 50 percent water ethylene blycol solution and water-to-water heat exchanger. Solar heated water is stored in a 5,000 gallon water storage tank located in the basement equipment room. A natural gas fired hot water boiler supplies hot water when the solar energy heat supply fails to meet the demand. The designed solar contribution is 71 percent of the heating load.

Source record↗

Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina

The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.

Source record↗

Cryogenic cooling of instruments in orbit - A standard solid cryogen cooler approach

A study has been conducted to determine the utility and characteristics of a solid cryogen cooler which could meet a variety of instrument and mission requirements. The cooler consists essentially of two stages of solid cryogen and two cooled shields. The inner shield is thermally grounded to the secondary (warmer) cryogen and provides a low temperature boundary around the colder primary stage, while the outer shield reduces the heat loads upon the secondary cryogen. The baseline design provides cooling of approximately 1 watt over the temperature range 60-100 K, 0.5 watts from 15 to 60 K, and 0.2 watts from 8 to 15 K for a one-year lifetime. For low cooling loads (0.1 W) and with use of an optional cooled shield, cooling lifetimes of 8 years are possible.

Nast, T. C.↗