Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Tidal and atmospheric forcing of the upper ocean in the Gulf of California. 2: Surface heat flux

Satellite infrared imagery and coastal meteorological data for March 1984 through February 1985 are used to estimate the net annual surface heat flux for the northern Gulf of California. The average annual surface heat flux for the area north of Guaymas and Santa Rosalia is estimated to be +74 W/sq m for the 1984-1985 time period. This is comparable to the +20-50 W/sq m previously obtained from heat and freshwater transport estimates made with hydrographic surveys from different years and months. The spatial distribution of the net surface heat flux shows a net gain of heat over the whole northern gulf. Except for a local maximum near San Esteban Island, the largest heat gain (+110-120 W/sq m) occurs in the Ballenas and Salsipuedes channels, where strong tidal mixing produces anomalously cold sea surface temperatures (SSTs) over much of the year. The lowest heat gain occurs in the Guayamas Basin (+40-50 W/sq m), where SSTs are consistently warmer. In the relatively shallow northern basin the net surface heat flux is farily uniform, with a net annual gain of approxmately +70 W/sq m. A local minimum in heat gain (approximately +60 W/sq m) is observed over the shelf in the northwest, where spring and summer surface temperatures are particularly high. A similar minimum in heat gain over the shelf was observed in a separate study in which historical SSTs and 7 years (1979-1986) of meteorological data from Puerto Penasco were used to estimate the net surface heat flux for the northern basin. In that study, however, the heat fluxes were higher, with a gain of +100 W/sq m over the shelf and +114 W/sq m in the northern basin. These larger values are directly attributable to the higher humidities in the 1979-1986 study compared to the 1984-1985 satellite study. High humidities reduce evaporation and the associated latent heat loss, promoting a net annual heat gain. In the norther Gulf of California, however, tidal mixing appears to play a key role in the observed gain of heat. Deep mixing in the island region produces a persistent pool of cold water which is mixed horizontally by the large-scale circulation, lowering surface temperatures over most of the northern gulf. These cold SSTs decrease evaporation by reducing the saturation vapor pressure of the overlying air. As a result, heat loss is substantially reduced, even when humidities are low. By removing heat from the surface, tidal mixing alters the time scale of air-sea interaction and reduces or possibly even inhibits the formation of deep water masses via convection.

Paden, Cynthia A.↗

Exploratory Environmental Tests of Several Heat Shields

Exploratory tests have been conducted with several conceptual radiative heat shields of composite construction. Measured transient temperature distributions were obtained for a graphite heat shield without insulation and with three types of insulating materials, and for a metal multipost heat shield, at surface temperatures of approximately 2,000 F and 1,450 F, respectively, by use of a radiant-heat facility. The graphite configurations suffered loss of surface material under repeated irradiation. Temperature distribution calculated for the metal heat shield by a numerical procedure was in good agreement with measured data. Environmental survival tests of the graphite heat shield without insulation, an insulated multipost heat shield, and a stainless-steel-tile heat shield were made at temperatures of 2,000 F and dynamic pressures of approximately 6,000 lb/sq ft, provided by an ethylene-heated jet operating at a Mach number of 2.0 and sea-level conditions. The graphite heat shield survived the simulated aerodynamic heating and pressure loading. A problem area exists in the design and materials for heat-resistant fasteners between the graphite shield and the base structure. The insulated multipost heat shield was found to be superior to the stainless-steel-tile heat shield in retarding heat flow. Over-lapped face-plate joints and surface smoothness of the insulated multi- post heat shield were not adversely affected by the test environment. The graphite heat shield without insulation survived tests made in the acoustic environment of a large air jet. This acoustic environment is random in frequency and has an overall noise level of 160 decibels.

Goodman, George P.↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

Numerical and Experimental Studies of Ultra Low Profile Three-dimensional Heat Sinks (3DHS) Made using a Novel Manufacturing Approach

The continued increase in electronic device packaging densities is placing ever more challenging performance requirements on air-cooled heat sinks. In cases where the state-of-the-art heat sink technology is unable of to meet these requirements, this often results in either a relaxation of design specifications, or the exploration of other thermal management technologies better able to handle high heat density applications, such as liquid cooling. Both of these approaches provide challenges to equipment designers, as relaxing requirements does not allow for a scale-able path to increased device densities and their associated functionality, while incorporating new thermal management technologies often requires major hardware redesigns, which has significant cost implications. In this work, we explore the use of air-cooled heat sinks incorporating three-dimensional features, so-called three-dimensional heat sinks (3DHS), that enhance heat transfer through a number of different physical mechanisms, as an approach to further extending the limits of air cooling. An ultra low profile (5.7 mm) heat sink application is targeted due to the significant thermal challenges associated with restrictions on heat sink height. We also present details on a novel manufacturing method that has significant cost advantages over other fabrication methods such as investment casting and direct metal printing. Experiments on 3DHS and conventional heat sink are conducted in a wind tunnel test apparatus as a function of inlet air mass flow rate and flow bypass above the heat sinks. The experimental results show a strong correlation between heat sink permeability and thermal performance, as measured by heat sink thermal resistance versus ideal pumping power. The results also illustrate the important effects of flow bypass on heat sink performance. The best performing 3DHS design is observed to have up to a 19% improvement in thermal performance relative to a conventional parallel fin heat sink of the same form factor. Comparison of the experimental results with finite-volume simulations of the laminar, steady equations for mass, momentum and energy transport shows good agreement for heat sink thermal resistance and pressure drop across the heat sink. For the case where the fluid flow is modeled as transitional and steady, there is a greater discrepancy between simulations and experiments, suggesting that the experimental flow conditions are predominantly laminar.

42 ENGINEERING↗

Assessment of Latent Heat Reservoirs for Thermal Management of QCW Laser Diodes

There is great interest in improving the thermal management of laser diodes intended for use as pumps in inertial confinement fusion systems. Laser diode power is currently constrained by heat dissipation in the diodes. Diodes typically dissipate a quantity of heat that is comparable to their optical power output. This heating of the diode junction causes a thermal rollover that prevents the output power from scaling linearly with current drive, and also results in reliability limits due to catastrophic failure at diode mirror facets. For the pulsed, quasi-continuous wave (QCW) operating mode employed for LIFE and certain DOD applications, {approx}5 kW/cm{sup 2} of heat must be removed on timescales of {approx}100{micro}s, which is determined by thermal paths located within {approx}200 {micro}m of the laser junction. For these reasons, QCW thermal management is extremely challenging. Reducing the diode junction temperature enables more efficient operation, reduced thermal chirp, and operation at higher output power without compromised reliability - which improves the diode costs as measured in $/W. We have proposed the use of latent heat reservoirs to improve thermal management of diodes used in pulsed, quasi-continuous wave (QCW) operation. Our basic concept involves placement of a reservoir of low-melting-point metal within a few hundred microns of the laser junction, as in Fig. 1-1. This metal's latent heat of fusion maintains a nearly constant temperature (like a cold plate) in the very near vicinity of the diode junction. This cold reservoir creates large thermal gradients, which in turn are anticipated to drive a large heat flow from the diode. In contrast, conventional QCW devices rely on thermal diffusion into a large solid mass which cannot be held at a fixed temperature, which significantly limits the thermal extraction. Our operational concept involves phase changes within the reservoir during every QCW pulse. During the early portion of the pulse, heating of the diode and its surrounding material initiates melting within the latent heat reservoir. This phase change results in a near-constant reservoir temperature that facilitates heat transfer. During the long ({approx}100 ms) time between QCW pulses, the reservoir metal resolidifies. A simple back-of-the-envelope calculation based on Gallium metal shows that a 50 {micro}m thick Gallium reservoir is sufficient to absorb all heat generated by a 350 {micro}s pulse at 5 kW/cm{sup 2}. While this calculation shows that a latent heat reservoir can provide sufficient capacity to handle the magnitude of heat generated, it does not address the transient change in the diode junction temperature, which depends on details the heat flow into and through the reservoir. For this reason, we undertook a set of numerical experiments to quantitatively assess the impact of latent heat reservoirs on junction temperature. This report documents the results of these simulations.

42 ENGINEERING↗

Energy recovery from waste incineration: Assessing the importance of district heating networks

Municipal solid waste incineration contributes with 20% of the heat supplied to the more than 400 district heating networks in Denmark. In evaluation of the environmental consequences of this heat production, the typical approach has been to assume that other (fossil) fuels could be saved on a 1:1 basis (e.g. 1 GJ of waste heat delivered substitutes for 1 GJ of coal-based heat). This paper investigates consequences of waste-based heat substitution in two specific Danish district heating networks and the energy-associated interactions between the plants connected to these networks. Despite almost equal electricity and heat efficiencies at the waste incinerators connected to the two district heating networks, the energy and CO{sub 2} accounts showed significantly different results: waste incineration in one network caused a CO{sub 2} saving of 48 kg CO{sub 2}/GJ energy input while in the other network a load of 43 kg CO{sub 2}/GJ. This was caused mainly by differences in operation mode and fuel types of the other heat producing plants attached to the networks. The paper clearly indicates that simple evaluations of waste-to-energy efficiencies at the incinerator are insufficient for assessing the consequences of heat substitution in district heating network systems. The paper also shows that using national averages for heat substitution will not provide a correct answer: local conditions need to be addressed thoroughly otherwise we may fail to assess correctly the heat recovery from waste incineration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

"Nanotechnology Enabled Advanced Industrial Heat Transfer Fluids"

ABSTRACT Nanotechnology Enabled Advanced industrial Heat Transfer Fluids” Improving the efficiency of Industrial Heat Exchangers offers a great opportunity to improve overall process efficiencies in diverse industries such as pharmaceutical, materials manufacturing and food processing. The higher efficiencies can come in part from improved heat transfer during both cooling and heating of the material being processed. Additionally, there is great interest in enhancing the performance and reducing the weight of heat exchangers used in automotives in order to increase fuel efficiency. The goal of the Phase I program was to develop nanoparticle containing heat transfer fluids (e.g., antifreeze, water, silicone and hydrocarbon-based oils) that are used in transportation and in the chemical industry for heating, cooling and recovering waste heat. Much work has been done to date at investigating the potential use of nanoparticle-enhanced thermal fluids to improve heat transfer in heat exchangers. In most cases the effect in a commercial heat transfer fluid has been marginal at best. In the Phase I work, we demonstrated that the thermal conductivity, and hence heat transfer, of a fluid containing nanoparticles can be dramatically increased when subjected to an external influence. The increase in thermal conductivity was significantly larger than what is predicted by commonly used thermal models for two-phase materials. Additionally, the surface of the nanoparticles was engineered so as to have a minimal influence on the viscosity of the fluid. As a result, a nanoparticle-laden fluid was successfully developed that can lead to enhanced heat transfer in both industrial and automotive heat exchangers

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground-source Heat Pumps Applied to Commercial Buildings

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

15 GEOTHERMAL ENERGY↗

Comparison of heat flux measurement techniques during the DIII-D metal ring campaign

The heat fluxes expected in the ITER divertor raise concerns about the damage tolerances of tungsten, especially due to thermal transients caused by edge localized modes (ELMs) as well as frequent temperature cycling from high to low extremes. Thus we are motivated to understand the heat flux conditions that can cause not only enhanced erosion but also bulk thermo-mechanical damage to a tungsten divertor. For the metal ring campaign in DIII-D, tungsten-coated TZM tile inserts were installed making two toroidal arrays of metal tile inserts in the lower divertor. This study examines the deposited heat flux on these rings with embedded thermocouples (TCs) sampling at 10 kHz and compares them to Langmuir probe (LP) and infrared thermography (IRTV) heat flux measurements. We see agreement of the TC, LP, and IRTV data within 20% of the heat flux averaged over the entire discharge, and that all three diagnostics suggest parallel heat flux at the OSP location increases linearly with input heating power. The TC and LP heat flux time traces during the discharge trend together during large changes to the average heat flux. By subtracting the LP measured inter-ELM heat flux from TC data, using a rectangular ELM energy pulse shape, and taking the relative size and duration of each ELM from ${{D}}_{\alpha }$ measurements, we extract the ELM heat fluxes from TC data. This over-estimates the IRTV measured ELM heat fluxes by a factor of 1.9, and could be due to the simplicity of the TC heat flux model and the assumed ELM energy pulse shape. ELM heat fluxes deposited on the inserts are used to model tungsten erosion in this campaign. These TC ELM heat flux estimates are used in addition to IRTV, especially in cases where the IRTV view to the metal ring is obstructed. We observe that some metal inserts were deformed due to exposed leading edges. The thermal conditions on these inserts are investigated with the thermal modeling code ABAQUS using our heat flux measurements when these edges were exposed. We report on how the thermal cycling on the ends of the inserts caused this deformation.

42 ENGINEERING↗

Port Graham Community Building Biomass Heating Design Project

Native Village of Port Graham completed preconstruction activities to prepare for construction and operations of a cord wood biomass heating system to five or more community buildings in Port Graham, Alaska. Project Description Native Village of Port Graham (NVPG) completed preconstruction activities that pave the way towards reduced local energy costs through the construction and operations of a cord wood biomass heating system. NVPG plans include installation of a GARN WHS 3200 Boiler that uses cord wood as fuel source. Implementation of the 700,000 Btu per hour output biomass community building heat utility would heat 5-community buildings in Port Graham, Alaska. Heating system is estimated to displace 85% of the heating fuel oil or 5365 gallons of fuel on an annual basis with an estimated peak output of 600,000 Btu per hour. Estimated savings is $15,112.00 per year. The construction cost estimate made to install the new biomass boiler system is estimated $251,693.47 with an additional Boiler Building expansion cost estimated at $97,828.40. Total installed cost is estimated $349,521.87. The WHS 3200 Boiler would be placed inside a new structure at the old community Water Plant Building site that is controlled by NVPG. Design of the new biomass heat plant and hot water loop system was completed by Richmond Engineering, NVPG contractor for the project. A hot water heat loop system running off the boiler is designed to be placed underground on lands controlled by NVPG and stubbed to feed hot water to existing base board heating system in the following community buildings: 1. Anesia Anahonak Moonin Health and Dental Clinic 2. Native Village of Port Graham offices 3. Port Graham Public Safety Building/Fire Department 4. Port Graham Corporation Office Building which also houses the Port Graham Museum and Head Start Center 5. North Pacific Rim Housing Authority Workshop/Old Fire Hall Existing community buildings fuel oil heating systems are to be retro-fitted to accommodate hot water from the proposed wood-burning GARN Boiler, once installed, and rely on the existing fuel oil-fired hot water heating equipment for backup. The boiler would use an estimated 125 bone dry tons, equivalent to 100 cords, woody biomass feedstock obtained from local lands per year. Project would use local labor as described in the Port Graham Biomass Project, report completed by Chena Power, Inc. and Winters and Associates as part of the in-kind support to the U. S. Department of Energy (DOE) project for work on a project for State of Alaska’s Alaska Energy Authority (AEA). NVPG will likely initiate operations of the biomass boiler system even though several operational variations were studied. Obtaining the fuel source could be done by contractors, PGVC employees, or NVPG employees. Feeding the system would likely be done by NVPG employees. A majority of the buildings heated would be owned by NVPG. The PGVC office would be heated as well as the Old Fire Hall used as a workshop and storage area for North Pacific Rim Housing Authority. One methodology studied to charge for cost of utilizing the community building biomass system would use a percentage of use of hot water generated by the biomass hot water system based on past heating oil usage in relation to all buildings heated by biomass hot water. The method is better described in the Port Graham Biomass Project report. Fuel source agreements have been drafted to enter into agreements with area landowners. One Native allotment owner has asked Chugachmiut Forestry to begin a timber sale process to sell timber off her lands, specifically wind thrown timber that was determined to be of sufficient quantity to supply to the proposed biomass heating system for approximately 5-years. On NVPG’s behalf, Chugachmiut has presented to PGVC three different documents, attached, that could lead to a sale of woody biomass fuel for the project for up to 25-years, the expected life of the project. PGVC has signed a letter of intent to negotiate a sale of woody biomass material April 30, 2015. Chugachmiut Forestry has conducted two different field forest measurements of Native allotment lands and PGVC forest and timber lands. Lands deemed road accessible for biomass harvest were analyzed for this project. Forestry then conducted three different analyses and developed two reports to determine forest biomass on a tons per acre basis in addition to timber volume measurements taken for forest management purposes. Permits required were limited. For the biomass building, the Kenai Peninsula Borough did not require a permit. State of Alaska, Department of Public Safety, Division of Fire and Life Safety requires a plan review for fire and life safety requirements called an application for Fire and Life Safety Plan Review that would require a registered design professional to sign the document. State of Alaska State Forest Practices Act is required to be followed for any timber sale or harvest. This Act also requires consultation with Alaska Department of Fish and Game when operations are in close proximity or cross anadromous waters. Native allotment lands require following U. S. Bureau of Indian Affairs timber sale contracting process and approval.

09 BIOMASS FUELS↗

Heat Exchanger Performance Impacts on Optimum Cost Conditions in Thermoelectric Energy Recovery Designs

Cost is just as important as power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG). Prior work [1] has shown that the system design that minimizes cost (e.g., the $/W value) can be close to the designs that maximize the system’s efficiency or power density, however, it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent work [1, 2, 3] the impact of heat exchanger conditions on the optimum TEG fill factors and cost scaling of a waste heat recovery thermoelectric generator with a detailed treatment of the hot side exhaust heat exchanger has been investigated further. The effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances [4] that maximize power output are considered. The optimum fill factor to minimize TEG energy recovery system costs is strongly dependent on the heat leakage fraction, σ, the mass flow rate of the exhaust, the hot-side heat exchanger effectiveness, heat exchanger UAh, and heat flux. These relationships are explored and characterized for typical exhaust gas-flow conditions to show the inherent design complexities. The heat exchanger costs often dominate the TEG cost equation and it is critical to fully understand the tradeoff between heat exchanger performance, optimum TEG fill factors, and cost to establish potentially optimum design points within the cost-performance design space. This work will explore the design tradeoffs and relationships within the cost-efficiency-power density design space for a typical thermoelectric energy recovery system application. The interplay between optimum TEG fill factors and heat exchanger design can impact system footprint, volume, and mass in weight-sensitive applications. Less-effective, low-cost heat exchangers may outperform higher cost alternatives from a market adoption perspective. This shift of emphasis acknowledging the interdependence of optimum TEG fill factors and heat exchanger performance has significant implications on thermoelectric waste heat recovery systems designs and their operation. In addition, preferred TEG design regimes exist that accommodate reasonable compromises in TE performance and cost. This effort highlights how the optimum fill factor–heat exchanger performance relations couple to these optimum TEG performance-cost domains based on TEG-system-level analyses and provides a focus for future system research and development efforts.

Energy recovery↗

System Modeling and Building Energy Simulations of Gas Engine Driven Heat Pump

To improve the system performance of a gas engine driven heat pump (GHP) system, an analytical modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system the sensible heat ratio (SHR- sensible heat ratio) can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion,using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of GHP in sixteen US cities, and the performances are compared to a baseline unit, which has a electrically-driven air conditioner with the seasonal COP of 4.1 for space cooling and a gas funace with 90% fuel efficiency for space heating.

building energy simulation↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗

Advanced Energy and Water Recovery Technology from Low Grade Waste Heat

The project has developed a nanoporous membrane based water vapor separation technology that can be used for recovering energy and water from low-temperature industrial waste gas streams with high moisture contents. This kind of exhaust stream is widely present in many industrial processes including the forest products and paper industry, food industry, chemical industry, cement industry, metal industry, and petroleum industry. The technology can recover not only the sensible heat but also high-purity water along with its considerable latent heat. Waste heats from such streams are considered very difficult to recover by conventional technology because of poor heat transfer performance of heat-exchanger type equipment at low temperature and moisture-related corrosion issues. During the one-year Concept Definition stage of the project, the goal was to prove the concept and technology in the laboratory and identify any issues that need to be addressed in future development of this technology. In this project, computational modeling and simulation have been conducted to investigate the performance of a nanoporous material based technology, transport membrane condenser (TMC), for waste heat and water recovery from low grade industrial flue gases. A series of theoretical and computational analyses have provided insight and support in advanced TMC design and experiments. Experimental study revealed condensation and convection through the porous membrane bundle was greatly improved over an impermeable tube bundle, because of the membrane capillary condensation mechanism and the continuous evacuation of the condensate film or droplets through the membrane pores. Convection Nusselt number in flue gas side for the porous membrane tube bundle is 50% to 80% higher than those for the impermeable stainless steel tube bundle. The condensation rates for the porous membrane tube bundle also increase 60% to 80%. Parametric study for the porous membrane tube bundle heat transfer performance was also done, which shows this heat transfer enhancement approach works well in a wide parameters range for typical flue gas conditions. Better understanding of condensing heat transfer mechanism for porous membrane heat transfer surfaces, shows higher condensation and heat transfer rates than non-permeable tubes, due to existence of the porous membrane walls. Laboratory testing has documented increased TMC performance with increased exhaust gas moisture content levels, which has exponentially increased potential markets for the product. The TMC technology can uniquely enhance waste heat recovery in tandem with water vapor recovery for many other industrial processes such as drying, wet and dry scrubber exhaust gases, dewatering, and water chilling. A new metallic substrate membrane tube development and molded TMC part fabrication method, provides an economical way to expand this technology for scaled up applications with less than 3 year payback expectation. A detailed market study shows a broad application area for this advanced waste heat and water recovery technology. A commercialization partner has been lined up to expand this technology to this big market. This research work led to new findings on the TMC working mechanism to improve its performance, better scale up design approaches, and economical part fabrication methods. Field evaluation work needs to be done to verify the TMC real world performance, and get acceptance from the industry, and pave the way for our commercial partner to put it into a much larger waste heat and waste water recovery market. This project is addressing the priority areas specified for DOE Industrial Technologies Program's (ITP's): Energy Intensive Processes (EIP) Portfolio - Waste Heat Minimization and Recovery platform.

02 PETROLEUM↗

Simulation of divertor heat flux width on EAST by BOUT++ transport code

The BOUT++ edge plasma transport code is applied to study the effects of neutral recycling, drifts and heating scheme on edge plasma profiles and the divertor heat flux width of two discharges of the experimental advanced superconducting tokamak (EAST) steady-state H-mode plasmas heated by low hybrid wave (LHW) and neutral beam (NB), respectively. Neutral recycling seems to have played an important role in the plasma density profile. The edge plasma density drops dramatically for the case w/o neutral recycling, while it can be sustained for the case w/ neutral recycling. Drifts are found to have significant influences on edge plasma profiles. Both the amplitude and width of the divertor heat flux are found to have increased a lot due to drifts. The simulated heat flux width w/ drifts for the two discharges shows reasonable agreement with the experiments. However, the width from the simulation and experiment for the LHW heated discharge is much larger than that of the NB heated discharge. Comparison with Goldston's drift-based model and more detailed analysis on the heat flux contributions from drifts versus turbulence show that drifts are the dominant factor in edge plasma transport for both LHW and NB heated discharges, while turbulence may have played a more important role in determining the heat flux width in LHW heated discharges than that in NB heated discharges. This may account for the larger heat flux width in the LHW heated discharge. The magnetic topology and the equilibrium change by the LHW power may also be a potential reason for the larger heat flux width in the LHW heated discharges, which still needs more evidence and studies to support it. Finally, additional SOLPS simulation w/o drifts for the two discharges show reasonable agreement with the counterpart from the BOUT++ simulation, suggesting the two are both suitable codes for EAST edge plasma simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Technical Report: Using Solid Particles as Heat Transfer Fluid for use in Concentrating Solar Power (CSP) Plants

In today’s industrial economy, energy consumption has never been higher. Over the last 15 years the US alone has consumed an average of nearly 100 quadrillion BTUs per year [21]. A need for clean and renewable energy sources has become quite apparent. The SunShot Initiative is an ambitious effort taken on by the United States Department of Energy that targets the development of solar energy that is cost-competitive with other methods for generating electricity. Specifically, this work is concerned with the development of concentrating solar power plants (CSPs) with granular media as the heat transfer fluid (HTF) from the solar receiver. Unfortunately, the prediction of heat transfer in multiphase flows is not well understood. For this reason, our aim is to fundamentally advance the understanding of multiphase heat transfer, particularly in gas-solid flows, while providing quantitative input for the design of a near black body receiver (NBB) that uses solid grains (like sand) as the HTF. Over the course of this three-year project, a wide variety of contributions have been made to advance the state-of-the art description for non-radiative heat transfer in dense, gas-solid systems. Comparisons between a state-of-the-art continuum heat transfer model and discrete element method (DEM) simulations have been drawn. The results of these comparisons brought to light the limitations of the continuum model due to inherent assumptions in its derivation. A new continuum model was then developed for heat transfer at a solid boundary by rigorously accounting for the most dominant non-radiative heat transfer mechanism (particle-fluid-wall conduction). The new model is shown to be in excellent agreement with DEM data and captures the dependence of heat transfer on particle size, a dependency that previous continuum models were not capable of. DEM and the new continuum model were then employed to model heat transfer in a variety of receiver geometries. The results provided crucial feedback on the efficiency and feasibility of various designs. Namely, a prototype design consisting of an array of heated hexagonal tubes was later supplanted by a vertical conduit with internal baffles. Due to low solids heat transfer on the bottom faces of the hexagonal tubes in the prototype, the predicted wall temperature gradients exceeded the design limitations. By contrast, the vertical conduit can be constructed to continually force particle-wall contacts, and thus, result in more desirable solids heat transfer and wall temperature gradients. Finally, a new heat flux boundary condition was developed for DEM simulations to assess the aforementioned wall temperature gradients. The new boundary condition advances current state-of-the-art techniques by allowing the heat fluxes to each phase to vary with space and time while the total flux remains constant. Simulations with the new boundary condition show that the total boundary heat flux is in good agreement with the imposed total boundary heat flux. While the methods we have utilized here are primarily numerical and fundamental by nature, they offer some key advantages of: (i) being robust and valid over a large range of conditions, (ii) able to quickly explore large parameter spaces, and (iii) aid in the construction of experiments. We have ultimately leveraged our computational capabilities to provide feedback on the design of a CSP which possesses great potential to become a cost effective source of clean and renewable electricity. Overall, ensuring that future energy demands are met in a responsible and efficient manner has far reaching impacts that span both ecologic and economic concerns. Regarding logistics, the project was successfully re-negotiated after the go/no-decisions of Years 1 and 2. All milestones were successfully completed.

14 SOLAR ENERGY↗