Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

On the feasibility of closed-loop control of intra-aortic balloon pumping

A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.

Clark, J. W., Jr.↗

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.↗

Skylab's photographic workhorse

There are ten Data Acquisition Cameras (DAC) aboard the Skylab workshop, and one additional is aboard each of the three command modules that ferry astronauts to Skylab. These cameras will transport approximately 40,000 feet of 16-mm film at frame rates from time exposures to 24 frames per second (fps). The heart of the 16-mm DAC system is a unique sequence camera. Approximately 80% of the Skylab 16-mm film will be exposed at 2 fps to maximize data acquisition time and remain within spacecraft return weight limitations. Of the approximately 225 accessories, the most unique item is the 400-foot magazine system.-

Gerlach, R.↗

The 1973 Mariner mission to Venus and Mercury. II

The heart of the spacecraft downlink is the flight data subsystem (FDS). The FDS combines the functions of science and engineering measurement control. The FDS can generate six principal telemetry formats, each of which may be transmitted directly to earth. Spacecraft engineering subsystems are considered, giving attention to the power subsystem, the attitude control subsystem, the propulsion subsystem, devices for temperature control, and the tracking subsystem. The mission operations system is also discussed together with the flight plan.

Hooke, A. J.↗

Analytical investigations employing dynamic mechanical properties

Dynamic mechanical spectroscopy has emerged as an effective laboratory method for analytical investigations of polymers. These methods were applied in investigating the property changes of silicone poppets implanted in artificial heart valves, and for exploring the cause of hardening of certain solid propellants. As a research activity, the property-structure relations which lead to the ability to superimpose dynamic data for epoxy resins were investigated.

Cuddihy, E. F.↗

Angiocardiographic methods for determination of left ventricular geometry and volume

Methods are described for calculating left ventricular (LV) dimensions and chamber volumes from radiographic films. The use of biplane films for the calculation of LV volume and volume change is based on the assumption of an ellipsoidal geometry. Calculation of LV volumes from biplane films usually overestimated known volumes in postmortem hearts regardless of the methods used for volume calculation. The reasons for this are probably best explained by the fact that a smooth-surface ellipse is used to represent the irregular cavity of the LV chamber. LV volume calculated from data in a single plane compared favorably and closely with volumes calculated from biplane films. A table of normal values of ventricular volume established by angiographic studies is presented.

Sandler, H.↗

Oxygen utilization of the human left ventricle - An indirect method for its evaluation and clinical considerations

An analytical method is presented for determining the oxygen consumption rate of the intact heart working (as opposed to empty but beating) human left ventricle. Use is made of experimental recordings obtained for the chamber pressure and the associated dimensions of the LV. LV dimensions are determined by cineangiocardiography, and the chamber pressure is obtained by means of fluid-filled catheters during retrograde or transeptal catheterization. An analytical method incorporating these data is then employed for the evaluation of the LV coronary oxygen consumption in five subjects. Oxygen consumption for these subjects was also obtained by the conventional clinical method in order to evaluate the reliability of the proposed method.

Ghista, D. N.↗

Modular liquid-cooled helmet liner for thermal comfort

A modular liquid-cooled helmet liner made of eight form-fitting neoprene patches was constructed. The liner was integrated into the sweatband of an Army SPH-4 helicopter aircrew helmet. This assembly was tested on four subjects seated in a hot (47 C), humid (40%) environment. Results indicate a marked reduction in the rate of increase of physiological body functions. Rectal temperature, weight loss, heart rate, and strain indices are all reduced to approximately 50% of uncooled levels. The cooling liner removed from 10% to 30% of total metabolic heat produced. This study also demonstrated the technical feasilibity of using a cooling liner in conjunction with a standard hard helmet. Potential applications of the cooling liner in thermally stressful environments are numerous, notably for helicopter and other aircrews.

Williams, B. A.↗

Effects of N2O narcosis on the contraction and repayment of an oxygen debt

The oxygen deficit, oxygen debt, and the difference between them were measured in five male and three female subjects during and after exercise while breathing either air or a normoxic mixture containing 33% N2O and nitrogen. With the exception of a higher respiratory quotient at rest in N2O, there were no statistically significant differences for oxygen consumption, carbon dioxide production, expired gas volume, heart rate or blood lactate while breathing N2O during rest, exercise, or recovery. An appreciably, but not statistically, greater mean oxygen deficit was found in N2O along with a significantly greater mean oxygen debt; deficit-debt difference was unaffected by N2O. It was speculated that N2O narcosis did not affect the ability to utilize oxygen but that the response to the greater oxygen need of exercise may have been slowed with perhaps a concomitant greater depletion of stored high energy compounds.

Schatte, C. L.↗

Computer program CORDET

A FORTRAN 4 computer program provides convenient simulation of an all-digital phase-lock loop (DPLL). The DPLL forms the heart of the Omega navigation receiver prototype. Through the DPLL, the phase of the 10.2 KHz Omega signal is estimated when the true signal phase is contaminated with noise. This investigation has provided a convenient means of evaluating loop performance in a variety of noise environments, and has proved to be a useful tool for evaluating design changes. The goals of the simulation are to: (1) analyze the circuit on a bit-by-bit level in order to evaluate the overall design; (2) see easily the effects of proposed design changes prior to actual breadboarding; and (3) determine the optimum integration time for the DPLL in an environment typical of general aviation conditions.

Palkovic, R. A.↗

Vectorcardiographic results from Skylab medical experiment M092: Lower body negative pressure

Vectorcardiograms were recorded via a modified Frank lead system from all crewmen of the three Skylab missions in conjuction with the Lower Body Negative Pressure - M092 Experiment. Data were analyzed by a specially developed computer program (VECTAN). Design of the test sequences allowed direct comparisons of supine resting, Earth based (reference) vectorcardiograms with those taken during lower body negative pressure stress and those obtained at rest in orbit, as well as combinations of these conditions. Results revealed several statistically significant space flight related changes; namely, increased testing and lower body negative pressure stressed heart rates, modestly increased PR interval and corrected QTC interval, and greatly increased P and QPS loop maximal amplitudes. In addition, orientation changes in the QRS maximum vector and the J-vector at rest in space seem quite consistent among crewmen and different from those caused by the application of lower body negative pressure. No clinical abnormalities were observed. Etiology of these findings is conjectured to be, at least in part, related to fluid mass shifts occurring in weightlessness and attendant alterations in cardiovascular dynamics and myocardial autonomic control mechanisms.

Hoffler, G. W.↗

Vectorcardiographic changes during extended space flight

To assess the effects of space flight on cardiac electrical properties, vectorcardiograms were taken on the 9 Skylab astronauts during the flights of 28, 59, and 84 days. The Frank lead system was used and observations were made at rest; during 25%, 50% and 75% of maximum exercise; during a short pulse of exercise (150 watts, 2 minutes); and after exercise. Data from 131 in-flight tests were analyzed by computer and compared to preflight and postflight values. Statistically significant increase in QRS vector magnitude (six of nine crewmen); T vector magnitude (five of nine crewmen); and resting PR interval duration (six of nine crewmen) occurred. During exercise the PR interval did not differ from preflight. Exercise heart rates inflight were the same as preflight, but increased in the immediate postflight period. With the exception of the arrhythmias, no deleterious vectorcardiographic changes were observed during the Skylab missions.

Smith, R. F.↗

Evaluation of the electromechanical properties of the cardiovascular system

Cardiovascular electromechanical measurements were collected on returning Skylab crewmembers at rest and during both lower body negative pressure and exercise stress testing. These data were compared with averaged responses from multiple preflight tests. Systolic time intervals and first heart sound amplitude changes were measured. Clinical cardiovascular examinations and clinical phonocardiograms were evaluated. All changes noted returned to normal within 30 days postflight so that the processes appear to be transient and self limited. The cardiovascular system seems to adapt quite readily to zero-g, and more importantly it is capable of readaptation to one-g after long duration space flight. Repeated exposures to zero-g also appear to have no detrimental effects on the cardiovascular system.

Bergman, S. A., Jr.↗

Design and development experience with a digital fly-by-wire control system in an F-8C airplane

To assess the feasibility of a digital fly-by-wire system, the mechanical flight control system of an F-8C airplane was replaced with a digital system and an analog backup system. The Apollo computer was used as the heart of the primary system. This paper discusses the experience gained during the design and development of the system and relates it to active control systems that are anticipated for future civil transport applications.

Deets, D. A.↗

Apollo experience report: Assessment of metabolic expenditures

A significant effort was made to assess the metabolic expenditure for extravehicular activity on the lunar surface. After evaluation of the real-time data available to the flight controller during extravehicular activity, three independent methods of metabolic assessment were chosen based on the relationship between heart rate and metabolic production, between oxygen consumption and metabolic production, and between the thermodynamics of the liquid-cooled garment and metabolic production. The metabolic assessment procedure is analyzed and discussed. Real-time use of this information by the Apollo flight surgeon is discussed. Results and analyses of the Apollo missions and comments concerning future applications are included.

Waligora, J. M.↗

Search for correlation between geomagnetic disturbances and mortality

Statistical evaluation of death rates in the U.S.A. from heart diseases or stroke did not show any correlation with measured geomagnetic pulsations and thus do not support a claimed relationship between geomagnetic activity and mortality rates to low frequency fluctuations of the earth's magnetic field.

Lipa, B. J.↗

Reactions of astronauts under weightless conditions

Experimental data show that weightlessness conditions lasting 5 days or more (18-25) do not produce significant disturbances in physical reactions of astronauts, with the exception of some singularities in functioning of the cardiovascular system: A reduction in heart rate and somewhat large fluctuations in the physiological indicators of cutaneogalvanic reactions.

Kasyan, I. I.↗