Development of the coastal zone color scanner for NIMBUS 7. Volume 1: Mission objectives and instrument description

An Earth scanning six channel (detector) radiometer using a classical Cassegrain telescope and a Wadsworth type grating spectrometer was launched aboard Nimbus 7 in order to determine the abundance or density of chlorophyll at or near the sea surface in coastal waters. The instrument also measures the sediment or gelbstroffe (yellow stuff) in coastal waters, detects surface vegetation, and measures sea surface temperature. Block diagrams and schematics are presented, design features are discussed and each subsystem of the instrument is described. A mission overview is included.

Source record↗

A possible technique for cometary studies with high angular and spectral resolution

The echelle spectrographs, designed for and used at the Cassegrain stations of the KPNO and CTIO 4-meter telescopes, are capable of cometary spectroscopy with seeing-limited angular resolution along the slit and with spectral resolving power (lambda/delta lambda) ranging from 10 to the 4th power to 10 to the 5th power. Various gratings, cameras and detectors can be used in combination for specific studies in the 3000A to 10,000A range.

Gull, T. R.↗

Manipulation of Light with Magneto-optic Stripe Domain Films

Magnetic diffraction grating materials, being developed to provide a simple means of deflecting light in a two dimensional, solid state fashion are discussed. The most promising material, for several applications, appears to be bismuth substituted iron garnet films in epitaxial form. Calculations indicate that deflection efficiency greater than 60% is possible in the near infrared region of the spectrum. Within the field of view of the deflector, measurements predict that 105 resolvable spots can be expected. Applications include: (1) general purpose deflection of free laser light, (2) image processing of extended sources such as transparencies, (3) programmable lensing, and (4) fiber optic matrix switching.

Torok, E. J.↗

The sixteen to forty micron spectroscopy from the NASA Lear jet

Two cryogenically cooled infrared grating spectrometers were designed, fabricated and used on the NASA Lear Jet Observatory. The first spectrometer was used to measure continuum sources such as dust in H II regions, the galactic center and the thermal emission from Mars, Jupiter, Saturn, and Venus over the 16 to 40 micron spectral range. The second spectrometer had higher resolution and was used to measure ionic spectral lines in H II regions (S III at 18.7 microns). It was later used extensively on NASA C-141 Observatory to make observations of numerous objects including H II regions, planetary nebulae, stars with circumstellar shells, the galactic center and extragalactic objects. The spectrometers are described including the major innovations and a list of the scientific contributions.

Houck, J. R.↗

Introducing the B stars

Methods for classifying B stars in the visible region by examining low reslution spectra; broadband colors; intermidiate band colors and H beta; absolute magnitude as a function of H beta and H gamma strength and of luminosity class; and the BCD system and its relation to the MK system are examined. The use of OAO-2 spectrophotometry; objective prism and objective grating spectra; and observations from the TD1 satellite for classifying B stars in the ultraviolet region are also discussed. Infrared and radio observations of these stars are reviewed as well as information available concerning masses, radii and velocity of escape.

Source record↗

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

Spectra of cosmic X-ray sources

X-ray measurements provide the most direct probes of astrophysical environments with temperatures exceeding one million K. Progress in experimental research utilizing dispersive techniques (e.g., Bragg and grating spectroscopy) is considerably slower than that in areas utilizing photometric techniques, because of the relative inefficiency of the former for the weak X-ray signals from celestial sources. As a result, the term "spectroscopy" as applied to X-ray astronomy has traditionally satisfied a much less restrictive definition (in terms of resolving power) than it has in other wavebands. Until quite recently, resolving powers of order unity were perfectly respectable, and still provide (in most cases) the most useful spectroscopic data. In the broadest sense, X-ray photometric measurements are spectroscopic, insofar as they represent samples of the overall electromagnetic continua of celestial objects.

Holt, S. S.↗

A Wolter type I LAMAR

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R. C.↗

Requirements for high quality X-ray spectroscopy in an Explorer class mission

Through the use of simulated X-ray spectra the question of instrument requirements for a spectrograph that could significantly advance X-ray astronomy is addressed. It it concluded that resolution (lambda/delta lambda) in the range of 200 to 500, and effective collecting area in excess of 200 sq cm are required. One design, based on the objective reflection grating concept, which would meet these stringent requirements in an Explorer class mission is presented.

Cash, W. C., Jr.↗

Current Studies of CH4 from 2.5 to 7 microns

The 3.5 micron region of methane was analyzed. The positions and strengths of approximately 9000 absorption lines in the region from 2400 to 3200 cm were measured. Spectra were obtained at a resolution of 0.1 cm using the Fourier transform spectrometer and at 0.02 cm resolution using the four passed grating spectrometer. The analysis of the 3.5 micron region required the use of spectra of CH4 in other regions, therefore the methane spectrum from 1200 to 4700 cm is indicated. The method used for the compilation of line lists is demonstrated.

Brown, L.↗

Technology thrusts for passive remote sensing. Sensing Technology Panel report

Technology thrusts for broadband spectrometry and gas filter radiometry development are identified. The development of 'smart' processing and cryogenics/cooling systems for all types of broadband spectrometers is advised. The use of large fixed gratings and the development of 1000-element arrays is recommended. Improvements suggested for interferometers are: the mitigation of background fluctuations; the development of multiaperature, multiband interferometers; and provision of in-flight alignment verification. Specifically recommended for gas filter radiometers are the development of gas filter cell technology, of liner and high dynamic range detectors, and of high uniform optical elements.

Source record↗

A Fourier transform spectrometer for visible and near ultra-violet measurements of atmospheric absorption

The development of a prototype, ground-based, Sun-pointed Michelson interferometric spectrometer is described. Its intended use is to measure the atmospheric amount of various gases which absorb in the near-infrared, visible, and near-ultraviolet portions of the electromagnetic spectrum. Preliminary spectra which contain the alpha, 0.8 micrometer, and rho sigma tau water vapor absorption bands in the near-infrared are presented to indicate the present capability of the system. Ultimately, the spectrometer can be used to explore the feasible applications of Fourier transform spectroscopy in the ultraviolet where grating spectrometers were used exclusively.

Parsons, C. L.↗

The IUE echelle blaze function

An improved form for the echelle blaze function derived by Ake (1981) was used to study the apparent variation of grating constant K with order m for the long and short wavelength spectrographs. For the LWR camera, early images indicate that K should vary linearly with order. It is suggested that this represents a rotation of the observed blaze centers on the camera compared to a constant K=m lambda line. In four years of use, changes in sensitivity across the camera changed the observed blaze function, inducing a curvature in the K versus m relation. This curvature varies in time with variations in camera response. The SWP camera shows these effects to a lesser degree.

Ake, T. B.↗

Planar Rowland spectrometer for fiber-optic wavelength demultiplexing

A planar Rowland spectrometer was fabricated and characterized as a wavelength demultiplexer for multimode fiber-optic applications. The spectrometer consisted of a planar multimode glass waveguide with two curved end faces and a cylindrical concave attached to one of the end faces. Semiconductor lasers with wavelengths between 0.825 and 0.845 micron were used for the measurements. Cross-talk isolation between two adjacent fibers with center-to-center separation of 175 microns (100 A in wavelength difference) was measured to be 18 dB. The device's performance was limited by grating diffraction efficiency, optical aberration, waveguide dispersion, and waveguide losses.

Yen, H. W.↗

Moire interferometry for thermal expansion of composites

Moire interferometry by reflection has been demonstrated using a real reference grating of 1200 lines/mm. The method is shown to be well adapted to thermal environments. Thermal expansion coefficients of graphite-epoxy composites have been measured with high precision over a wide range from nearly zero to 3300 microstrains in the temperature range 297-422 K. Random errors characterized by one standard deviation can be as small as one microstrain.

Bowles, D. E.↗

A wavelength scannable XeCl oscillator-ring amplifier laser system

A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.

Pacala, T. J.↗

Recent spectroscopic measurements of NOx in the lower stratosphere

High resolution (0.02 and 0.06 per cm) Fourier transform airborne systems were used for measurements of long path atmospheric absorption spectra, covering many of the NOx infrared bands. Atmospheric emission measurements with liquid helium cooled grating spectrometer systems at 0.5 per cm resolution were also carried out from different altitudes in the NOx bands region. Analysis of the absorption and emission spectra provides quantification of NOx in the lower stratosphere at different latitudes and seasons, as well as diurnal variability.

Goldman, A.↗