Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Effects of boron and glass hybrid epoxy-composites on graphite-fiber release in an aircraft fire

Recent studies have shown that the benefits gained by using graphite-epoxy composite structures may not be realized without some risk. The graphite fibers are very good electrical conductors and fibers released into the environment during a fire create a possible hazard to electrical equipment. Several graphite-epoxy hybrids were exposed to a fire and simulated explosion and their graphite fiber retention characteristics were examined. Several low melting-temperature glasses which wet and clump graphite-fibers and a glass/graphite fabric which reduced impact damage were identified as promising hybridizing components to minimize graphite fiber release.

Tompkins, S. S.↗

An assessment of the risk arising from electrical effects associated with the release of carbon fibers from general aviation aircraft fires

A Poisson type model was developed and exercised to estimate the risk of economic losses through 1993 due to potential electric effects of carbon fibers released from United States general aviation aircraft in the aftermath of a fire. Of the expected 354 annual general aviation aircraft accidents with fire projected for 1993, approximately 88 could involve carbon fibers. The average annual loss was estimated to be about $250 (1977 dollars) and the likelihood of exceeding $107,000 (1977 dollars) in annual loss in any one year was estimated to be at most one in ten thousand.

Rosenfield, D.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 1: Coal-fired nocogeneration process boiler, section A

About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuels consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.

Knightly, W. F.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 1: Coal-fired nocogeneration process boiler, section B

About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.

Knightly, W. F.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 6: Computer data. Part 2: Residual-fired nocogeneration process boiler

About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.

Knightly, W. F.↗

Electronic equipment vulnerability to fire released carbon fibers

The vulnerability of electronic equipment to damage by carbon fibers released from burning aircraft type structural composite materials was investigated. Tests were conducted on commercially available stereo power amplifiers which showed that the equipment was damaged by fire released carbon fibers but not by the composite resin residue, soot and products of combustion of the fuel associated with burning the carbon fiber composites. Results indicate that the failure rates of the equipment exposed to the fire released fiber were consistent with predictions based on tests using virgin fibers.

Pride, R. A.↗

Carbon fiber plume sampling for large scale fire tests at Dugway Proving Ground

Carbon fiber sampling instruments were developed: passive collectors made of sticky bridal veil mesh, and active instruments using a light emitting diode (LED) source. These instruments measured the number or number rate of carbon fibers released from carbon/graphite composite material when the material was burned in a 10.7 m (35 ft) dia JP-4 pool fire for approximately 20 minutes. The instruments were placed in an array suspended from a 305 m by 305 m (1000 ft by 1000 ft) Jacob's Ladder net held vertically aloft by balloons and oriented crosswind approximately 140 meters downwind of the pool fire. Three tests were conducted during which released carbon fiber data were acquired. These data were reduced and analyzed to obtain the characteristics of the released fibers including their spatial and size distributions and estimates of the number and total mass of fibers released. The results of the data analyses showed that 2.5 to 3.5 x 10 to the 8th power single carbon fibers were released during the 20 minute burn of 30 to 50 kg mass of initial, unburned carbon fiber material. The mass released as single carbon fibers was estimated to be between 0.1 and 0.2% of the initial, unburned fiber mass.

Chovit, A. R.↗

Degradation of tensile and shear properties of composites exposed to fire or high temperature

The decrease in ultimate tensile strength, shear strength, tensile modulus, and shear modulus of fiber reinforced composites exposed to fire or to high temperature was investigated. A simple model was developed for calculating the mass loss of the material and the thickness of the char layer. The mass loss as well as the degradation in tensile and shear properties of Fiberite T300/1034 and Hercules AS/3501-6 graphite epoxy composites exposed to fire were measured. A correlation between the degradation in properties and the calculated mass loss and the char layer thickness was developed. A technique was proposed for predicting material damage through the use of such correlations.

Pering, G. A.↗

Synthesis of Fire-Extinguishing Dawsonites

Simple nonaqueous process synthesizes sodium or potassium, dawsonites effective against hydrocarbon fuel fires. Fire-extinguishing alkali metal dawsonites are prepared using a finely-pulverized equimolar mixture of hydrogen carbonate, or carbonates and aluminum hydroxide heated for 1 to 6 hours under carbon dioxide pressure.

Altman, R. L.↗

Improved Fire-Resistant Resins for Laminates

Fire-resistant resins for fabricating laminates with inorganic fibers, especially graphite fibers, are formed from bisimides containing main-chain phosphorus and olefinic end groups. Bisimides are thermally polymerized to form resins and laminates virtually imcombustible in pure oxygen at 300 degrees C. New resins are suitable for many applications requiring good adhesion and excellent resistance to heat, fire, solvents and chemicals.

Fohlen, G. M.↗

Wet countdown demonstration and flight readiness firing

The prelaunch tests for the Space Transportation System 1 flight are briefly described. Testing is divided into two major sections: the wet countdown demonstration test/flight readiness firing, which includes a 20 second test firing of the orbiter's three main engines, and a mission verification test, which is centered on flight and landing operations. The functions of the countdown sequence are listed and end of mission and mission abort exercises are described.

Source record↗

Development of assembly techniques for fire resistant aircraft interior panels

Ten NASA Type A fire resistant aircraft interior panels were fabricated and tested to develop assembly techniques. These techiques were used in the construction of a full scale lavatory test structure for flame propagation testing. The Type A panel is of sandwich construction consisting of Nomex honeycomb filled with quinone dioxime foam, and bismaleimide/glass face sheets bonded to the core with polyimide film adhesive. The materials selected and the assembly techniques developed for the lavatory test structure were designed for obtaining maximum fire containment with minimum smoke and toxic emission.

Lee, S. C. S.↗

The NASA/Baltimore Applications Project (BAP). Computer aided dispatch and communications system for the Baltimore Fire Department: A case study of urban technology application

An engineer and a computer expert from Goddard Space Flight Center were assigned to provide technical assistance in the design and installation of a computer assisted system for dispatching and communicating with fire department personnel and equipment in Baltimore City. Primary contributions were in decision making and management processes. The project is analyzed from four perspectives: (1) fire service; (2) technology transfer; (3) public administration; and (5) innovation. The city benefitted substantially from the approach and competence of the NASA personnel. Given the proper conditions, there are distinct advantages in having a nearby Federal laboratory provide assistance to a city on a continuing basis, as is done in the Baltimore Applications Project.

Levine, A. L.↗

Infrared radiation emerging from smoke produced by brush fires

The IR radiative transport properties of brush fire smoke clouds, computed for a model with finite horizontal dimensions as well as the more common plane-parallel model, are presented. The finite model is a three-dimensional version of the two-stream approximation applied to cubic clouds of steam, carbon, and silicates. Assumptions are made with regard to the shape and size distributions of the smoke particles. It is shown that 11.5-micron radiometry can detect fires beneath smoke clouds if the path integrated mass density of the smoke is less than or equal to 3 g/sq m.

Weinman, J. A.↗

Fire-Retardant Epoxy Adhesives

Phosphorus-containing epoxy is fire-retardant and translucent. Intended as adhesive for laminated plastic sheets, new material bonds well to titanium dioxide-filled plastic film, which ordinarily shows little surface interaction with adhesives. Fire retardancy has been demonstrated, and smoke density is low enough to avoid smoke obscuration.

Bilow, N.↗

Telemetry Speeds Forest-Fire Control

Airborne system rapidly delivers hard copy to firefighters. Sensors in airplane send data to ground station for image processing. Imagery immediately transferred to U.S. Geologic Survey (USGS) maps by photo interpreter. Maps transmitted by telecopies directly to fire-control camps. Receipt by fire camp less than 10 minutes. Information aids in decisions involving deployment of firefighters and equipment, flood control, monitoring oilspills, observing thermal currents, and pollutions monitoring.

Arvesen, J. C.↗

Training Simulator for Fire Management

Users manipulate resources in practicing fire-control strategy. Users manipulate resource information displayed on two separate monitors, as computer-generated messages and computer-controlled fire scenes.

Smith, K. A.↗