Analytical study of the feasibility of a pneumatic neutron flux detector
Pneumatic thermal neutron flux detector feasibility study
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Pneumatic thermal neutron flux detector feasibility study
Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cava (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.
This report describes the process and findings of a Wind Energy Feasibility Study (Study) conducted by the Lower Sioux Indian Community (Community). The Community is evaluating the development of a wind energy project located on tribal land. The project scope was to analyze the critical issues in determining advantages and disadvantages of wind development within the Community. This analysis addresses both of the Community's wind energy development objectives: the single turbine project and the Commerical-scale multiple turbine project. The main tasks of the feasibility study are: land use and contraint analysis; wind resource evaluation; utility interconnection analysis; and project structure and economics.
This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.
The results are reported of a preliminary feasibility screening study for providing long-term solutions to the problems of handling and managing radioactive wastes by extraterrestrial transportation of the wastes. Matrix materials and containers are discussed along with payloads, costs, and destinations for candidate space vehicles. The conclusions reached are: (1) Matrix material such as spray melt can be used without exceeding temperature limits of the matrix. (2) The cost in mills per kw hr electric, of space disposal of fission products is 4, 5, and 28 mills per kw hr for earth escape, solar orbit, and solar escape, respectively. (3) A major factor effecting cost is the earth storage time. Based on a normal operating condition design for solar escape, a storage time of more than sixty years is required to make the space disposal charge less than 10% of the bus-bar electric cost. (4) Based on a 10 year earth storage without further processing, the number of shuttle launches required would exceed one per day.
Feasibility of low temperature, variable infrared source - calibration of instrumentation used in defining earth horizon
Deep Vadose Zone contamination is a significant issue because it represents a potential source for continued release of contamination to the groundwater and associated receptors. This contamination, which is the result of past waste disposal practices on the Hanford Site Central Plateau, occurs deep in the subsurface and is not easily remediated by typical surface remedies. The Deep Vadose Zone is defined as the sediment below the limit of typical surface-based remedies (such as, excavation or caps), but above the water table. The Central Plateau Deep Vadose Zone begins at a depth of approximately 15 m (50 ft) below ground surface and extends to a depth of approximately 76 m (250 ft) below ground surface. Cleanup of the Deep Vadose Zone is challenging because contamination is difficult to access and expensive to characterize; contaminants occur at different depths and soil types; conventional, surface-based remedies have limited effectiveness; and remedy performance is difficult to predict, test, and monitor. Typically, remedial technologies for Deep Vadose Zone contamination are less developed than for the shallow soil contamination or saturated groundwater contaminants. In addition, few remediation technologies have been tested in the field, and fewer still have been successfully implemented as full remedial actions. These challenges, along with the limited number of potentially applicable remediation technologies, complicate the decision-making process for evaluating and selecting Deep Vadose Zone remedial alternatives. The Deep Vadose Zone remediation technologies pre-screening involved a comprehensive review of potentially applicable technologies for remediating Deep Vadose Zone contamination in the Hanford Site's Central Plateau. The list of remediation technologies was developed from previous Hanford Site studies, science and technology databases, as well as other cleanup projects across the country that have similar conditions. The list of remediation technologies was shared with the public and stakeholders to provide an opportunity to identify additional technologies. From these efforts, 59 technologies that may support future remediation of the Deep Vadose Zone were identified. The initial list of 59 potential technologies were then screened in order to identify viable or potentially viable technologies whose implementation would benefit from further investigation and evaluation during the remedial investigation/feasibility study activities. This approach eliminated five technologies from further consideration because they either would not be ready to support remediation within the next 3 to 5 years or were not applicable for Deep Vadose Zone remediation. Eleven (11) technologies were identified as viable, requiring no further testing or investigation during the RCRA Facility Investigation/Remedial Investigation activities. The remaining 43 potentially applicable technologies were identified as requiring additional testing or investigation to determine whether they should be considered further in the selection of a remedial alternative for the 200-DV-1 Operable Unit. The results of this pre-screening effort will be used to plan and scope the appropriate field investigation, treatability study, and feasibility study tasks during development of the 200-DV-1 Operable Unit Work Plan. (authors)
Feasibility study for using radio frequency resonance counting for measuring propellant mass aboard orbiting spacecraft
Feasibility study and results on use of radio frequency resonance counting for measuring propellant mass aboard orbiting spacecraft
Flight investigation of lightweight helicopter to study feasibility of fixed collective pitch autorotations
Abstract Objective The ‘Connected We St@nd’ is an online self‐management intervention programme for people receiving in‐centre haemodialysis and family caregivers that combines an educational and psychosocial support component. This study aimed to evaluate its feasibility and acceptability before proceeding to a large‐scale trial. Design This was a pre‐post single‐arm feasibility pilot study conducted with adults undergoing in‐centre haemodialysis and family caregivers. Methods Feasibility was based on eligibility, consent, retention, completion and intervention adherence rates, while acceptability was assessed in post‐intervention focus group interviews. Results Twenty‐six people (16 adults on haemodialysis and 10 family caregivers) recruited through social networks completed the intervention. Consent, retention and completion rates were excellent (>90%) and eligibility (77.5%) and intervention adherence were satisfactory (69% for the psychosocial support sessions). Qualitative findings revealed that participants shared positive feelings regarding their participation in the programme. The valuable interactions with group peers and health psychologists during the support sessions, the perception of the adequacy and coherence of the programme's contents and materials and the participants' confidence in using the platform developed to deliver the intervention were some of the aspects highlighted as facilitators of intervention acceptability. Additionally, people on haemodialysis and caregivers reported that participation in the programme brought several educational and emotional benefits (e.g., additional disease‐related knowledge, improved communication and coping skills, greater confidence in managing dialysis complications or caregiving demands) that helped increase their self‐management skills and psychosocial adjustment to the demands of kidney failure and renal therapies. Conclusions The results suggested that the ‘Connected We St@nd’ programme is likely to be feasible and acceptable for adults on haemodialysis and family caregivers, thus representing a promising resource for the future of interdisciplinary renal rehabilitation. Suggestions were made to fine‐tune the intervention design to proceed with a large‐scale trial.
Feasibility design of instrument system to collect data of horizon radiance profile in carbon dioxide absorption band
The Department of Energy (DOE) Environmental Management Los Alamos Field Office (EM-LA) is examining options for managing its transuranic (TRU) waste currently in interim storage at the Waste Control Specialists LLC (WCS) facility located near Andrews, Texas. As part of this examination, a Draft Engineering Evaluation and Initial Feasibility Study, collectively referred to as the Feasibility Study, is being implemented to investigate the feasibility of different options and methodologies for preparing the waste for transport and disposal at the Waste Isolation Pilot Plant (WIPP). To support the needs identified in the Feasibility Study, the Savannah River National Laboratory (SRNL) has been requested to pursue the characterization and assess the classification of inappropriately treated Remediated Nitrate Salt (RNS) wastes generated at the Los Alamos National Laboratory (LANL). Previous results from experimentation conducted at SRNL showed that both reaction time and water content had an observable effect on the exothermicity of a remediated waste surrogate under conditions mimicking the SW-846 Method 1050 test for spontaneous combustion. To further elucidate parameters that may contribute to the propensity for spontaneous combustion, SRNL designed and performed additional benchscale testing on simulated wastes targeting the compositions of six remediated drums of similar material previously sampled and characterized at LANL. Differential scanning calorimetry analysis displayed a general decrease in reactivity with increasing age and triethanolamine addition. Review of heat generation data versus analyzed compositions indicate that regardless of salt composition, water content, or age, no substantial combustion was witnessed for any mixture tested that contained at least 50 wt% of organic material.
A preliminary study was conducted of the feasibility of space disposal of the actinide class of radioactive waste material. This waste was assumed to contain 1 and 0.1 percent residual fission products, since it may not be feasible to completely separate the actinides. The actinides are a small fraction of the total waste but they remain radioactive much longer than the other wastes and must be isolated from human encounter for tens of thousands of years. Results indicate that space disposal is promising but more study is required, particularly in the area of safety. The minimum cost of space transportation would increase the consumer electric utility bill by the order of 1 percent for earth escape and 3 percent for solar escape. The waste package in this phase of the study was designed for normal operating conditions only; the design of next phase of the study will include provisions for accident safety. The number of shuttle launches per year required to dispose of all U.S. generated actinide waste with 0.1 percent residual fission products varies between 3 and 15 in 1985 and between 25 and 110 by 2000. The lower values assume earth escape (solar orbit) and the higher values are for escape from the solar system.
The goals of the NASA Standard Gas Generator (NSGG) Program are to create a NASA standard gas generating cartridge, characterize its performance, and make it readily available to users. A cartridge within the same envelope as the NASA Standard Initiator (NSI) has the greatest potential use. This potential use is described in viewgraph form. Our approach for NSGG development and qualification was planned to be conducted in several phases. Test methods were developed to evaluate output performance for a variety of potential applications. A feasibility study using modified NSI's was accomplished. Preliminary and final development will be conducted with a delta qualification to evaluate the effects of manufacturing lots and environments. Feasibility study results, feasibility study conclusions, and future plans are presented.
A preliminary feasibility study of the microwave multi-applications payload (MMAP) system for the Spacelab has been carried out. The initial objectives of this study have been to determine the minimum equipment requirements of the MMAP and the feasibility of placing the numerous large aperture antennas in the Spacelab. The study was begun by reviewing the experimental objectives and techniques and determining areas of commonality. Emphasis was given to the determination of common RF equipment requirements. These requirementers were considered after agreement among the experiments had been reached on limiting the number of frequencies to be used in the system. This was done so that the number of antennas, transmitters, and receivers could be minimized. The electronics system block diagram and the antenna configurations were considered in some details. It was concluded that the MMAP is feasible and can be an economical method of achieving a large number of experimental goals.
The report presents a feasibility study of a new type of gas turbine. A partial oxidation gas turbine (POGT) shows potential for really high efficiency power generation and ultra low emissions. There are two main features that distinguish a POGT from a conventional gas turbine. These are associated with the design arrangement and the thermodynamic processes used in operation. A primary design difference of the POGT is utilization of a non?catalytic partial oxidation reactor (POR) in place of a conventional combustor. Another important distinction is that a much smaller compressor is required, one that typically supplies less than half of the air flow required in a conventional gas turbine. From an operational and thermodynamic point of view a key distinguishing feature is that the working fluid, fuel gas provided by the OR, has a much higher specific heat than lean combustion products and more energy per unit mass of fluid can be extracted by the POGT expander than in the conventional systems. The POGT exhaust stream contains unreacted fuel that can be combusted in different bottoming ycle or used as syngas for hydrogen or other chemicals production. POGT studies include feasibility design for conversion a conventional turbine to POGT duty, and system analyses of POGT based units for production of power solely, and combined production of power and yngas/hydrogen for different applications. Retrofit design study was completed for three engines, SGT 800, SGT 400, and SGT 100, and includes: replacing the combustor with the POR, compressor downsizing for about 50% design flow rate, generator replacement with 60 90% ower output increase, and overall unit integration, and extensive testing. POGT performances for four turbines with power output up to 350 MW in POGT mode were calculated. With a POGT as the topping cycle for power generation systems, the power output from the POGT ould be increased up to 90% compared to conventional engine keeping hot section temperatures, pressures, and volumetric flows practically identical. In POGT mode, the turbine specific power (turbine net power per lb mass flow from expander exhaust) is twice the value of the onventional turbine. POGT based IGCC plant conceptual design was developed and major components have been identified. Fuel flexible fluid bed gasifier, and novel POGT unit are the key components of the 100 MW IGCC plant for co producing electricity, hydrogen and/or yngas. Plant performances were calculated for bituminous coal and oxygen blown versions. Various POGT based, natural gas fueled systems for production of electricity only, coproduction of electricity and hydrogen, and co production of electricity and syngas for gas to liquid and hemical processes were developed and evaluated. Performance calculations for several versions of these systems were conducted. 64.6 % LHV efficiency for fuel to electricity in combined cycle was achieved. Such a high efficiency arise from using of syngas from POGT exhaust s a fuel that can provide required temperature level for superheated steam generation in HRSG, as well as combustion air preheating. Studies of POGT materials and combustion instabilities in POR were conducted and results reported. Preliminary market assessment was performed, and recommendations for POGT systems applications in oil industry were defined. POGT technology is ready to proceed to the engineering prototype stage, which is recommended.
This work summarizes a feasibility study on testing numerical algorithms that are suitable and efficient for advanced system analysis code development under the mutli-physics framework, MOOSE. The key is the implementation of a high-order one-dimensional staggered-grid finite volume method (SG-FVM), and its direct interaction with the linear/nonlinear solver, PETSc. Leveraging the existing capabilities of the SAM code, significant code coverages were established in the finite volume method code. This in turn allows for a suite of test problems with different problem sizes and levels of complexity to be used to quantify the performance improvement of the finite volume method code. As evidently shown in this study, the implemented SG-FVM demonstrated superior performance improvement against a direct finite element method implementation through MOOSE for the wide range of selected problems. On two computer systems, the speedup was observed to be significant, with at least one order of magnitude of solving time reduction. In addition, for a complex reactor model, transient simulation was performed using the finite volume method code, the results of which agree very well with the reference results from the finite element method code. Overall, this study demonstrates a successful feasibility study on the proposed numerical algorithms and software structure to support advanced system analysis tool development. In this work, short-term priority development and testing items were identified, and long-term code adoption and integration plans were made for the eventual deployment of the finite volume method in the SAM code.