Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Ion Exchange Testing with SRF Resin FY2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0, which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Hanford Tank Waste Treatment and Immobilization Pl↗

Analytical Study on Thermal and Mechanical Design of Printed Circuit Heat Exchanger

The analytical methodologies for the thermal design, mechanical design and cost estimation of printed circuit heat exchanger are presented in this study. In this study, three flow arrangements of parallel flow, countercurrent flow and crossflow are taken into account. For each flow arrangement, the analytical solution of temperature profile of heat exchanger is introduced. The size and cost of printed circuit heat exchangers for advanced small modular reactors, which employ various coolants such as sodium, molten salts, helium, and water, are also presented.

42 ENGINEERING↗

Ion Exchange Testing with SRF Resin FY 2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.01, which was prepared and approved in response to the Test Specification 24590-PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590-PTF-TEF-RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Ion exchange↗

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99 Tc, effective management of 99 Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99 Tc during the vitrification process. Removal of 99 Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99 Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99 Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 - ). Perrhenate (ReO 4 - ) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of 291 mL/g at a 100:1 phase ratio. This slightly exceeds the computer-modeled equilibrium distribution. The modeling agreed well with the experimental data for perrhenate removal with minor adjustments. Predicted breakthrough performance was on average within about 20% of measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Temperature Heat Exchanger Design and Fabrication for Systems with Large Pressure Differentials

The project’s main purpose was to design, build and test a compact heat exchanger for supercritical carbon dioxide (sCO 2 ) power cycle recuperators. The compact recuperator is required to operate at high temperature and high pressure differentials, 169 bar (~2,500 psi), between streams of sCO 2 . Additional project tasks included building a hot air-to-sCO 2 Heater heat exchanger (HX) and design, build and operate a test loop to characterize the recuperator and heater heat exchangers. A novel counter-current microtube recuperator was built to meet the high temperature high differential pressure criteria and tested. The compact HX design also incorporated a number of features that optimize material use, improved reliability and reduced cost. The air-to-sCO 2 Heater HX utilized a cross flow, counter-current, micro-tubular design. This compact HX design was incorporated into the test loop and exceeded design expectations. The test loop design to characterize the prototype Brayton power cycle HXs was assembled, commissioned and operated during the program. Both the prototype recuperator and Heater HXs were characterized. Measured results for the recuperator confirmed the predictions of the heat transfer models developed during the project. Heater HX data analysis is ongoing.

20 FOSSIL-FUELED POWER PLANTS↗

Low-Cost Recuperative Heat Exchanger for Supercritical Carbon Dioxide Power Systems (Final Scientific/Technical Report)

Closed Brayton super-critical CO 2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m 3 /UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO 2 . Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $\$ $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $\$ $1,500/UA. In addition, the 5,083 kW unit HELC cost of $\$ $61.09/kW is 33.6% lower than the $\$ $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Ultra-compact and efficient heat exchanger for solar desalination with unprecedented scaling resistance

The objective is to design, prototype, and test a heat exchanger technology with an efficiency improvement of more than 150% compared to state-of-the-art heat exchanger technology (UA/volume), with significantly improved fouling/scaling resistance at elevated temperatures (>120°C) when compared to existing technology where scaling is a major performance-limiting issue, as well as at lower operating-temperatures (~63-110°C). We now report our overall progress on the project. An ultra-compact, efficient heat exchanger geometry has been developed that can maximize surface-area-to-volume ratio so that proposed target (UA/volume). Advanced manufacturing techniques, such additive manufacturing, have made it possible to create complex structures cost effectively. In addition to traditional manufacturing methods, additive manufacturing has been successfully used for the development of high-performance geometries. These methods allow the ability to create custom surface textures, which are deployed to dramatically control wettability and create energy-gradient surfaces. These techniques allow fouling/scaling nucleation to be spatially controlled, such that as the fouling layer grows it will be broken and removed by flow forces.

42 ENGINEERING↗

Developing an Ultra-Compact, Topology-Optimized Heat Exchanger using Additive Manufacturing

Traditional heat exchanger designs have relied on a plate-fin architecture, assembled in a crossflow configuration. These HX designs are limited in their maximum allowable temperature and, therefore, efficiency. More advanced designs, such as those containing counter-flow, microtube cores, can yield higher efficiencies, but generally require complex headers. The design of such headers is usually determined based on user experience rather than on rigorous design tools, which can lead to lossy architectures; conventional headers can generate up to 50% of the total pressure loss through the HX. Furthermore, the consequences of manufacturing techniques are rarely considered during the design phase. Our team has developed an ultra-compact, topology-optimized heat exchanger capable of operating in environments with temperatures and pressures up to 800°C (1472°F) and 250 bar (3626 psi), respectively. Throughout the program, the team leveraged extensive additive manufacturing research and experience in supercritical carbon dioxide (sCO 2 ) power generation experience to develop and commercialize the technology. The final power density numbers for the subscale and full-scale heat exchangers are >15 kW/kg and >50 kW/L, which includes the core and the headers. The team has involved the RTX business units, notably Collins Aerospace, in discussions for commercializing the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Low Cost Glass-Ceramic Matrix Composites for Harsh Environment Heat Exchangers (Final Technical Report)

Nearly all high temperature heat exchangers are currently constructed from metallic alloys that can have good capability but are limited to hot inlet temperatures in the range of 1,200 to 1,400 °F. In general, increasing the hot inlet temperature will improve existing application cycles to operate more efficiently, and it will enable new application cycles to be viable that otherwise would not be. The objective of this project was to mature the technologies associated with the development of a ceramic-class heat exchanger that would significantly increase the operating temperature to 1,600 °F and above. The approach taken was to use Glass-Ceramic Matrix Composite (G-CMC) material and to fabricate coupon-scale tube sheet heat exchangers (HXs) to identify risks, refine details of the process and develop a pathway for this novel approach.

36 MATERIALS SCIENCE↗

Enhancing particle-to-sCO2 heat exchanger effectiveness through novel high-porosity metallic foams

In this project, a novel concept of Octet-shape based lattice frame material was developed for deployment in particle-to-sCO2 heat exchangers for CSP application. A comprehensive experimental and numerical program was performed to investigate and characterize the thermal and flow transport behavior in high porosity lattice frame material. The thermal properties include effective thermal conductivity and interstitial heat transfer coefficient and flow properties including permeability and inertial coefficient. Above quantities were determined for both air flow and heated particle flow through the porous channels which were representative of the hot channel in a typical counter flow heat exchanger. The cold side of the heat exchanger feature minichannels which are known to be very efficient in thermal transport. The goal of this project was to enhance the overall heat transfer coefficient (Up) on the hot side by introducing Octet-shape based lattice frame material through enhancement in effective thermal conductivity of the channel and through enhancement in the interstitial heat transfer coefficient.

14 SOLAR ENERGY↗

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability (CRADA NFE-21-08888 Final Report)

Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. Eck Industries successfully casted Al-Ce-Mg heat exchanger. ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE↗

Joining Study for Formed Plate Heat Exchangers (CRADA Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

99 GENERAL AND MISCELLANEOUS↗

Sulfate Conversion of Reillex HPQ Anion Exchange Resin for Disposal (Interim Report)

This report describes preliminary data to validate the Savannah River Plutonium Processing Facility’s (SRPPF) flowsheet for conversion of used Reillex HPQ anion exchange resin from the nitrate form to the sulfate form. The nitrate form is an oxidizer and therefore does not meet acceptance criteria for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose of this study is to develop data to support acceptance for this disposition pathway. Due to the challenges characterizing the nitrate concentration on solid resin, the data developed to date are based upon indirect analysis of the ion exchange column effluent by ion chromatography. These challenges are discussed and two methods for quantification of nitrate directly on the resin are recommended for further development: TGA-MS and permanganate digestion followed by IC. The resin used for this work was provided in the chloride form; this is the form in which resin is supplied by the manufacturer. However, it had to be converted to the nitrate form, which is the form that will be used in SRPPF’s ion exchange process, prior to use in the sulfate conversion experiments. The chloride-form resin was characterized. A lab-scale procedure for the conversion of Reillex HPQ resin from the chloride to nitrate form was validated. The nitrate-form resin was assessed for particle size and chloride concentration to ensure it met SRPPF’s facility specifications. The baseline sulfate conversion flowsheet was tested. However, nitrate was still detectable in the effluent after approximately 10 bed volumes of 1 M sodium sulfate had been passed through the resin bed. Additional experiments were performed to assess the effect of increasing the feed volume, reducing the flowrate, the use of 2 M sulfuric acid instead of sodium sulfate, and the use of irradiated resin. The sulfuric acid test was the only one which provided a nondetectable nitrate concentration (<0.002 M) in the effluent. Detectable nitrate in the column effluent suggests that nitrate is still present on the resin itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

SHOTEAM: Superalloy Heat exchangers Optimized for Temperature Extremes and Additive Manufacturability (Final Technical Report)

UCLA developed an extreme-condition heat exchanger technology targeted to ultra-high efficiency hybrid aviation power cycles. The heat exchanger targeted operation at 50 kW (thermal) at supercritical CO 2 pressures of 80 and 250 bar (1160 and 3626 psi) in hot and cold streams, respectively and at a hot-stream inlet temperature of 800°C (1472°F). A metallic superalloy capable of withstanding high temperature and pressure was used to fabricate a microtube shell-and-tube-based design supplemented with 3D-printed tube augmentations. The optimized design enhanced overall heat transfer while maintaining a small overall form factor and low weight. This class of heat exchanger could dramatically improve efficiency, power density, and cost effectiveness for new hybrid aviation power cycles, thus enabling economically feasible routes to air vehicle propulsion with substantially less CO 2 emissions to the environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continuation of Studies on Development of ODS Heat Exchanger Tubing

The Department of Energy (DOE), National Energy Technology Center (NETL), has initiated a strategic plan for the development of advanced technologies needed to design and build fossil fuel plants with very high efficiency and environmental performance. These plants, referred to as 'Vision 21' and FutureGen programs by DOE, will produce electricity, chemicals, fuels, or a combination of these products, and possibly secondary products such as steam/heat for industrial use. MA956 is a prime candidate material being considered for a high temperature heat exchanger in the 'Vision 21' and FutureGen programs. This material is an oxide dispersion strengthened (ODS) alloy; however, there are some gaps in the data required to commit to the use of these alloys in a full-size plant. To fill the technology gaps for commercial production and use of the material for 'Advanced Power Generation Systems' this project has performed development activity to significant increase in circumferential strength of MA956 as compared to currently available material, investigated bonding technologies for bonding tube-to-tube joints through joining development, and performed tensile, creep and fire-side corrosion tests to validate the use and fabrication processes of MA956 to heat exchanger tubing applications. Development activities within this projected has demonstrated increased circumferential strength of MA956 tubes through flow form processing. Of the six fabrication technologies for bonding tube-to-tube joints, inertia friction welding (IFW) and flash butt welding (FBW) were identified as processes for joining MA956 tubes. Tensile, creep, and fire-side corrosion test data were generated for both base metal and weld joints. The data can be used for design of future systems employing MA956. Based upon the positive development activities, two test probes were designed and fabricated for field exposure testing at 1204 C ({approx}2200 F) flue gas. The probes contained tube portions with FBW and IFW welded MA956. Field testing of the probes and remaining heat exchanger design activity will be performed by Oak Ridge National Laboratory under DOE Contract DE-AC05-00OR22725.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heat exchanger temperature response for duty-cycle transients in the NGNP/HTE.

Control system studies were performed for the Next Generation Nuclear Plant (NGNP) interfaced to the High Temperature Electrolysis (HTE) plant. Temperature change and associated thermal stresses are important factors in determining plant lifetime. In the NGNP the design objective of a 40 year lifetime for the Intermediate Heat Exchanger (IHX) in particular is seen as a challenge. A control system was designed to minimize temperature changes in the IHX and more generally at all high-temperature locations in the plant for duty-cycle transients. In the NGNP this includes structures at the reactor outlet and at the inlet to the turbine. This problem was approached by identifying those high-level factors that determine temperature rates of change. First are the set of duty cycle transients over which the control engineer has little control but which none-the-less must be addressed. Second is the partitioning of the temperature response into a quasi-static component and a transient component. These two components are largely independent of each other and when addressed as such greater understanding of temperature change mechanisms and how to deal with them is achieved. Third is the manner in which energy and mass flow rates are managed. Generally one aims for a temperature distribution that minimizes spatial non-uniformity of thermal expansion in a component with time. This is can be achieved by maintaining a fixed spatial temperature distribution in a component during transients. A general rule of thumb for heat exchangers is to maintain flow rate proportional to thermal power. Additionally the product of instantaneous flow rate and heat capacity should be maintained the same on both sides of the heat exchanger. Fourth inherent mechanisms for stable behavior should not be compromised by active controllers that can introduce new feedback paths and potentially create under-damped response. Applications of these principles to the development of a plant control strategy for the reference NGNP/HTE plant can be found in the body of this report. The outcome is an integrated plant/control system design. The following conclusions are drawn from the analysis: (1) The plant load schedule can be managed to maintain near-constant hot side temperatures over the load range in both the nuclear and chemical plant. (2) The reactor open-loop response is inherently stable resulting mainly from a large Doppler temperature coefficient compared to the other reactivity temperature feedbacks. (3) The typical controller used to manage reactor power production to maintain reactor outlet temperature at a setpoint introduces a feedback path that tends to destabilize reactor power production in the NGNP. (4) A primary loop flow controller that forces primary flow to track PCU flow rate is effective in minimizing spatial temperature differentials within the IHX. (5) Inventory control in both the primary and PCU system during ramp load change transients is an effective means of maintaining high NGNP thermal efficiency while at reduced electric load. (6) Turbine bypass control is an effective means for responding to step changes in generator load when equipment capacity limitations prevent inventory control from being effective. (7) Turbine bypass control is effective in limiting PCU shaft over speed for the loss of generator load upset event. (8) The proposed control strategy is effective in limiting time variation of the differential spatial temperature distribution in the IHX during transients. Essentially the IHX can be made to behave in a manner where each point in the IHX experiences approximately the same temperature rate of change during a transient. (9) The stability of the closed-loop Brayton cycle was found to be sensitive to where one operates on the turbo-machine performance maps. There are competing interests: more stable operation means operating on the curves at points that reduce overall cycle efficiency. Future work should address in greater detail elements that came to light in the course of this work. Specifically: (1) A stability analysis should be performed to identify the phenomena that control reactor outlet temperature stability when operating with the Reactor Outlet Temperature Controller. The goal is to identify a better performing controller. (2) Future simulations should be performed with multiple axial nodes. The single axial node model for the core used in this work gives rise to an initial core reactor outlet temperature perturbation that is a numerical artifact. (3) The tradeoffs referred to above regarding the dependence of Brayton cycle stability and efficiency on performance curve characteristics and use need to be better understood. (4) The role of xenon was neglected in this work and needs to be included in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗