Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Turbulent kinetics of a large wind farm and their impact in the neutral boundary layer

High-resolution large-eddy simulation of the flow over a large wind farm (64 wind turbines) is performed using the HIGRAD/FIRETEC-WindBlade model, which is a high-performance computing wind turbine–atmosphere interaction model that uses the Lagrangian actuator line method to represent rotating turbine blades. These high-resolution large-eddy simulation results are used to parameterize the thrust and power coefficients that contain information about turbine interference effects within the wind farm. Those coefficients are then incorporated into the WRF (Weather Research and Forecasting) model in order to evaluate interference effects in larger-scale models. In the high-resolution WindBlade wind farm simulation, insufficient distance between turbines creates the interference between turbines, including significant vertical variations in momentum and turbulent intensity. The characteristics of the wake are further investigated by analyzing the distribution of the vorticity and turbulent intensity. Quadrant analysis in the turbine and post-turbine areas reveals that the ejection motion induced by the presence of the wind turbines is dominant compared to that in the other quadrants, indicating that the sweep motion is increased at the location where strong wake recovery occurs. Regional-scale WRF simulations reveal that although the turbulent mixing induced by the wind farm is partly diffused to the upper region, there is no significant change in the boundary layer depth. The velocity deficit does not appear to be very sensitive to the local distribution of turbine coefficients. However, differences of about 5% on parameterized turbulent kinetic energy were found depending on the turbine coefficient distribution. Furthermore, turbine coefficients that consider interference in the wind farm should be used in wind farm parameterization for larger-scale models to better describe sub-grid scale turbulent processes.

17 WIND ENERGY↗

VLASOV SIMULATIONS OF MULTI-ION PLASMA TURBULENCE IN THE SOLAR WIND

Hybrid Vlasov-Maxwell simulations are employed to investigate the role of kinetic effects in a two-dimensional turbulent multi-ion plasma, composed of protons, alpha particles, and fluid electrons. In the typical conditions of the solar-wind environment, and in situations of decaying turbulence, the numerical results show that the velocity distribution functions of both ion species depart from the typical configuration of thermal equilibrium. These non-Maxwellian features are quantified through the statistical analysis of the temperature anisotropy, for both protons and alpha particles, in the reference frame given by the local magnetic field. Anisotropy is found to be higher in regions of high magnetic stress. Both ion species manifest a preferentially perpendicular heating, although the anisotropy is more pronounced for the alpha particles, according to solar wind observations. The anisotropy of the alpha particle, moreover, is correlated to the proton anisotropy and also depends on the local differential flow between the two species. Evident distortions of the particle distribution functions are present, with the production of bumps along the direction of the local magnetic field. The physical phenomenology recovered in these numerical simulations reproduces very common measurements in the turbulent solar wind, suggesting that the multi-ion Vlasov model constitutes a valid approach to understanding the nature of complex kinetic effects in astrophysical plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

13 HYDRO ENERGY↗

Distributed Acoustic Sensing for Whale Vocalization Monitoring: A Vertical Deployment Field Test

Abstract There is growing interest in floating offshore wind turbine (FOWT) technology, where turbines are installed on floating structures anchored to the seabed, allowing wind energy development in areas unsuitable for traditional fixed-platform turbines. Responsible development requires monitoring the impact of FOWTs on marine wildlife, such as whales, throughout the operational lifecycle of the turbines. Distributed acoustic sensing (DAS)—a technology that transforms fiber-optic cables into vibration sensor arrays—has been demonstrated for acoustic monitoring of whales using seafloor telecommunications cables. However, no studies have yet evaluated DAS performance in dynamic, engineered environments, such as floating platforms or moving vessels with complex, dynamic strain loads, despite their relevance to FOWT settings. This study addresses that gap by deploying DAS aboard a boat in Monterey Bay, California, where a fiber-optic cable was lowered using a weighted and suspended mooring line, enabling vertical deployment. Humpback whale vocalizations were captured and identified in the DAS data, noise sources were identified, and DAS data were compared to audio captured by a standalone hydrophone attached to the mooring line and a nearby hydrophone on a cabled observatory. This study is unique in: (1) deploying DAS in a vertical deployment mode, where noise from turbulence, cable vibrations, and other sources posed additional challenges compared to seafloor DAS applications; (2) demonstrating DAS in a dynamic, nonstationary setup, which is uncommon for DAS interrogators typically used in more stable environments; and (3) leveraging looped sections of the cable to reduce the noise floor and mitigate the effects of excessive cable vibrations and strain. This research demonstrates DAS’s ability to capture whale vocalizations in challenging environments, highlighting its potential to enhance underwater acoustic monitoring, particularly in the context of renewable energy development in offshore environments.

Saw, Jaewon↗

Temperature-based Instanton Analysis: Identifying Vulnerability in Transmission Networks

A time-coupled instanton method for characterizing transmission network vulnerability to wind generation fluctuation is presented. To extend prior instanton work to multiple-time-step analysis, line constraints are specified in terms of temperature rather than current. An optimization formulation is developed to express the minimum wind forecast deviation such that at least one line is driven to its thermal limit. Results are shown for an IEEE RTS-96 system with several wind-farms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

The effect of variability on X-ray binary luminosity functions: multiple-epoch observations of NGC 300 with Chandra

We have obtained three epochs of Chandra ACIS-I observations (totaling ∼184 ks) of the nearby spiral galaxy NGC 300 to study the logN–logS distributions of its X-ray point-source population down to ∼2 × 10{sup −15} erg s{sup −1} cm{sup −2} in the 0.35–8 keV band (equivalent to ∼10{sup 36} erg s{sup −1}). The individual epoch logN–logS distributions are best described as the sum of a background active galactic nucleus (AGN) component, a simple power law, and a broken power law, with the shape of the logN–logS distributions sometimes varying between observations. The simple power law and AGN components produce a good fit for “persistent” sources (i.e., with fluxes that remain constant within a factor of ∼2). The differential power-law index of ∼1.2 and high fluxes suggest that the persistent sources intrinsic to NGC 300 are dominated by Roche-lobe-overflowing low-mass X-ray binaries. The variable X-ray sources are described by a broken power law, with a faint-end power-law index of ∼1.7, a bright-end index of ∼2.8–4.9, and a break flux of ∼8×10{sup −15} erg s{sup −1} cm{sup −2} (∼4 × 10{sup 36} erg s{sup −1}), suggesting that they are mostly outbursting, wind-fed high-mass X-ray binaries, although the logN–logS distribution of variable sources likely also contains low-mass X-ray binaries. We generate model logN–logS distributions for synthetic X-ray binaries and constrain the distribution of maximum X-ray fluxes attained during outburst. Our observations suggest that the majority of outbursting X-ray binaries occur at sub-Eddington luminosities, where mass transfer likely occurs through direct wind accretion at ∼1%–3% of the Eddington rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Impacts of Wind and Solar on Fossil-Fueled Generators: Preprint

High penetrations of wind and solar power will impact the operations of the remaining generators on the power system. Regional integration studies have shown that wind and solar may cause fossil-fueled generators to cycle on and off and ramp down to part load more frequently and potentially more rapidly. Increased cycling, deeper load following, and rapid ramping may result in wear-and-tearimpacts on fossil-fueled generators that lead to increased capital and maintenance costs, increased equivalent forced outage rates, and degraded performance over time. Heat rates and emissions from fossil-fueled generators may be higher during cycling and ramping than during steady-state operation. Many wind and solar integration studies have not taken these increased cost and emissions impactsinto account because data have not been available. This analysis considers the cost and emissions impacts of cycling and ramping of fossil-fueled generation to refine assessments of wind and solar impacts on the power system.

01 COAL, LIGNITE, AND PEAT↗

Western Wind and Solar Integration Study Phase 2 (Presentation)

This presentation accompanies Phase 2 of the Western Wind and Solar Integration Study, a follow-on to Phase 1, which examined the operational impacts of high penetrations of variable renewable generation on the electric power system in the West and was one of the largest variable generation studies to date. High penetrations of variable generation can induce cycling of fossil-fueled generators. Cycling leads to wear-and-tear costs and changes in emissions. Phase 2 calculated these costs and emissions, and simulated grid operations for a year to investigate the detailed impact of variable generation on the fossil-fueled fleet. The presentation highlights the scope of the study and results.

14 SOLAR ENERGY↗

Solar wind kinetic instabilities at small plasma betas

The ordinary perpendicular mode of drifting bi-Maxwellian plasma particle distributions with and without temperature anisotropy can provide aperiodic instabilities. These instabilities occur if the perpendicular thermal energy is much smaller than the streaming energy. This provides instabilities at small parallel plasma betas β{sub ∥}<1 and temperature anisotropies A < 1. In this regime, the solar wind is unstable, which cannot be explained so far. To clarify if the ordinary perpendicular mode can be responsible for this instability, here we compare measurements in the solar wind with the instability provided by this mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling Streamflow and Sediment Transport Under Current and Future Climates at the West Valley Site - 20231

Performance Assessment models often require inputs representing specific hydrologic processes such as streamflow and sediment flux. This paper details the development of a process-level hydrologic model and its use in a Probabilistic Performance Assessment (PPA) system-level model for the West Valley Site in western New York. For this PPA model, a watershed model was developed using SWAT (Soil and Water Assessment Tool) and used to evaluate water and sediment fluxes in nearby streams draining the Site. A particular challenge of probabilistic modeling over long periods of time is scaling parameters appropriately so that outcomes are not grossly over- or underestimated. This challenge is especially important when the spatial and temporal scales of process and system level models differ. In this instance, the SWAT watershed model and GoldSim PPA model have similar spatial scales of stream reaches and sub-catchments within a single watershed (approximately hundreds to tens of thousands of square meters, but the temporal scales differ considerably. The SWAT model calculates streamflow and sediment transport rates at the daily scale, while the PPA model requires long-term average values that are applied over hundreds to thousands of year-long periods. As such, distributions of daily climatic parameters such as average precipitation rate, temperature, wind speed, and relative humidity were developed to force a transient SWAT model that captures the dynamic behavior of the watershed in response to daily changes in the weather. Output from the model, which includes stream flow (m{sup 3}/y) and sediment transport rate (Mg/y) is then averaged over a 100-year period as an approximation for the long-term average values which can be applied in GoldSim. A single SWAT model was run 5000 times with varying climatic inputs and deterministic soil, land use, and elevation data, and the range of outputs were compiled into a distribution which can be implemented stochastically into the PPA Model. Additionally, this paper includes a high-level discussion of how changes in future climate affect weather input distributions, and a summary of how those changes in weather affect the outcomes from the SWAT model and the inputs into the PPA model. In this analysis, future climate distributions were developed based on climate research documenting the expected changes to precipitation and temperature in western New York. The 5,000 SWAT simulations were then repeated with these future climate distributions, and the resulting output was implemented into the PPA Model as hydrologic conditions under a future climate. In the current version of the PPA Model, hydrologic parameters change linearly from the 'current climate' conditions to the 'future climate' conditions over a period of 100 years, after which they remain constant. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical study of reconnection exhausts in the solar wind

Magnetic reconnection is a fundamental process that changes magnetic field configuration and converts a magnetic energy to flow energy and plasma heating. This paper presents a survey of the plasma and magnetic field parameters inside 418 reconnection exhausts identified in the WIND data from 1995-2012. The statistical analysis is oriented on the re-distribution of the magnetic energy released due to reconnection between a plasma acceleration and its heating. The results show that both the portion of the energy deposited into heat as well as the energy spent on the acceleration of the exhaust plasma rise with the magnetic shear angle in accord with the increase of the magnetic flux available for reconnection. The decrease of the normalized exhaust speed with the increasing magnetic shear suggests a decreasing efficiency of the acceleration and/or the increasing efficiency of heating in high-shear events. However, we have found that the already suggested relation between the exhaust speed and temperature enhancement would be rather considered as an upper limit of the plasma heating during reconnection regardless of the shear angle.

79 ASTRONOMY AND ASTROPHYSICS↗

Cyber Threat Landscape for Distribution Systems

INL cyber analysts will present an overview of the current threat landscape for distribution systems. We will begin with examples of known attacks that have occurred recently to motivate the threat analysis and mitigation discussed in the remainder of the presentation. Examples may include the attacks affecting wind plants in Europe in Spring 2022, ransomware attacks on city utilities and commercial distribution systems, and advanced persistent threats (APTs) including the attacks on Ukrainian electric system in 2015 and 2016, as well as more recent evidence of other APT activity. We will present the end-to-end attack paths and discuss the various attacker skills, financing, motivations, and access that contributed to these attacks. In the second part of this presentation, we will discuss mitigating the cyber threats for distribution systems. We will discuss recent publicly disclosed vulnerabilities and explain their relevant context for distribution system security. Likely attacks to affect distribution systems, such as denial-of-service (DoS), ransomware, edge-device compromise, and advanced persistent threats (APTs) will be described. In addition to an overview of these kinds of attacks, we will provide examples of the various ways in which these attacks can start and what systems they can affect. Simple, cost-effective counter-measures to these attacks will be discussed and we will emphasize how these mitigations can reduce threats when properly applied and maintained.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probability-Weighted LMP and RCP for Day-Ahead Energy Markets using Stochastic Security-Constrained Unit Commitment: Preprint

Variable renewable generation resources are increasing their penetration on electric power grids. These resources have weather-driven fuel sources that vary on different time scales and are difficult to predict in advance. These characteristics create challenges for system operators managing the load balance on different timescales. Research is looking into new operational techniques andstrategies that show great promise on facilitating greater integration of variable resources. Stochastic Security-Constrained Unit Commitment models are one strategy that has been discussed in literature and shows great benefit. However, it is rarely used outside the research community due to its computational limits and difficulties integrating with electricity markets. This paper discusses howit can be integrated into day-ahead energy markets and especially on what pricing schemes should be used to ensure an efficient and fair market.

17 WIND ENERGY↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗