Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Intensive Computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

EMPIRICAL DETERMINATION OF EINSTEIN A-COEFFICIENT RATIOS OF BRIGHT [Fe II] LINES

The Einstein spontaneous rates (A-coefficients) of Fe{sup +} lines have been computed by several authors with results that differ from each other by up to 40%. Consequently, models for line emissivities suffer from uncertainties that in turn affect the determination of the physical conditions at the base of line excitation. We provide an empirical determination of the A-coefficient ratios of bright [Fe II] lines that would represent both a valid benchmark for theoretical computations and a reference for the physical interpretation of the observed lines. With the ESO-Very Large Telescope X-shooter instrument between 3000 Å and 24700 Å, we obtained a spectrum of the bright Herbig-Haro object HH 1. We detect around 100 [Fe II] lines, some of which with a signal-to-noise ratios ≥100. Among these latter lines, we selected those emitted by the same level, whose dereddened intensity ratios are direct functions of the Einstein A-coefficient ratios. From the same X-shooter spectrum, we got an accurate estimate of the extinction toward HH 1 through intensity ratios of atomic species, H I recombination lines and H{sub 2} ro-vibrational transitions. We provide seven reliable A-coefficient ratios between bright [Fe II] lines, which are compared with the literature determinations. In particular, the A-coefficient ratios involving the brightest near-infrared lines (λ12570/λ16440 and λ13209/λ16440) are in better agreement with the predictions by the Quinet et al. relativistic Hartree-Fock model. However, none of the theoretical models predict A-coefficient ratios in agreement with all of our determinations. We also show that literature data of near-infrared intensity ratios better agree with our determinations than with theoretical expectations.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation

Purpose: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented. Methods: Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w{sub t} that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system. Results: The average difference between theoretical and experimental w{sub t} was found to range from 8% to 21%. Experimental w{sub t} values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm{sup 2} and larger are discernable. Conclusions: The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point Cloud Based Approach to Stem Width Extraction of Sorghum

A revolution in the field of genomics has produced vast amounts of data and furthered our understanding of the genotypephenotype map, but is currently constrained by manually intensive or limited phenotype data collection. We propose an algorithm to estimate stem width, a key characteristic used for biomass potential evaluation, from 3D point cloud data collected by a robot equipped with a depth sensor in a single pass in a standard field. The algorithm applies a two step alignment to register point clouds in different frames, a Frangi filter to identify stemlike objects in the point cloud and an orientation based filter to segment out and refine individual stems for width estimation. Individually, detected stems which are split due to occlusions are merged and then registered with previously found stems in previous camera frames in order to track temporally. We then refine the estimates to produce an accurate histogram of width estimates per plot. Since the plants in each plot are genetically identical, distributions of the stem width per plot can be useful in identifying genetically superior sorghum for biofuels.

09 BIOMASS FUELS↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗

Blending Education and Polymer Science: Semiautomated Creation of a Thermodynamic Property Database

Structured databases of chemical and physical properties play a central role in the everyday research activities of scientists and engineers. In materials science, researchers and engineers turn to these databases to quickly query, compare, and aggregate various properties, thereby allowing for the development or application of new materials. The vast majority of these databases have been generated manually, through decades of labor-intensive harvesting of information from the literature, yet while there are many examples of commonly used databases, a significant number of important properties remain locked within the tables, figures, and text of publications. The question addressed in our work is whether and to what extent the process of data collection can be automated. Students of the physical sciences and engineering are often confronted with the challenge of finding and applying property data from the literature, and a central aspect of their education is to develop the critical skills needed to identify such data and discern their meaning or validity. To address shortcomings associated with automated information extraction while simultaneously preparing the next generation of scientists for their future endeavors, we developed a novel course-based approach in which students develop skills in polymer chemistry and physics and apply their knowledge by assisting with the semiautomated creation of a thermodynamic property database.

Collaborative/Cooperative Learning↗

Broadly Applicable Dose Model for Radiotherapy Beams from 6-25 MV

The goal of modern external beam radiotherapy is to deliver a highly targeted radiation dose to a specified treatment volume while sparing the healthy surrounding tissue as much as possible. However, some healthy tissue radiation exposure is unavoidable. Healthy tissue in the margin of the treatment field will receive absorbed doses on the order of the prescribed dose, and tissue far out of field will receive stray dose from scattered and leakage radiation. These doses can lead to late effects such as secondary cancers both near the treatment field and far out of field in tissues only receiving stray radiation dose. Many researchers have investigated algorithms to model absorbed dose from external beam photon radiation therapy; however, none of these works have fully addressed the stray dose far from the treatment field. The AAPM Task Group Report No. 36 described three main sources of stray radiation from external beam radiation therapy delivered with electron linear accelerators. Radiation scattered from the treatment head, known as head scatter, is primarily important within about 10 cm from the field edge. Patient scatter is an important source up to around 30 cm from the field edge. Finally, leakage radiation emanates from the treatment enclosure and predominates the stray radiation dose beyond about 30 cm. Monte Carlo simulations have been a useful research tool for modeling stray dose, but these methods have not found use in clinical settings due to their complexity and long computational times. The feasibility of analytical models to predict stray dose from radiation therapy has been supported by several works, but few attempts have been made at developing models accurate for both in-field and out-of-field doses. Jagetic and Newhauser reported on one such model that predicts absorbed dose from therapeutic, scatter, and leakage radiation with promising results. This model was validated at 6 MV for Conformal Radiation Therapy (CRT) beams from an Elekta linac. Intensity Modulated Radiation Therapy (IMRT) was not considered, and the model has not been tested at beam energies greater than 6 MV. Additionally, this model relies on proprietary, machine specific parameters, and so adapting the model for use on treatment units from other manufacturers is not straightforward. In this study we aim to test whether a physics-based analytical modeling approach is broadly applicable and if sufficient accuracy can be achieved without the need for proprietary, machine specific parameters. In order to accomplish this, a new analytical model was developed that does not rely on machine specific parameters, so that it can easily be trained on measurements from whatever treatment machine is available at a given clinic. This model was tested using measured data from a variety of treatment machines and techniques in the 6 MV to 25 MV energy interval. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Delayed Gamma-Ray Spectroscopy for Non-Destructive Assay of Nuclear Materials

High-­energy, beta-delayed gamma-­ray spectroscopy is a potential, non-­destructive assay techniques for the independent verification of declared quantities of special nuclear materials at key stages of the fuel cycle and for directly assaying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Other potential applications include determination of MOX fuel composition, characterization of nuclear waste packages, and challenges in homeland security and arms control verification. Experimental measurements were performed to evaluate fission fragment yields, to test methods for determining isotopic fractions, and to benchmark the modeling code package. Experimental measurement campaigns were carried out at the IAC using a photo-­neutron source and at OSU using a thermal neutron beam from the TRIGA reactor to characterize the emission of high-­energy delayed gamma rays from 235 U, 239 Pu, and 241 Pu targets following neutron induced fission. Data were collected for pure and combined targets for several irradiation/spectroscopy cycle times ranging from 10/10 seconds to 15/30 minutes.The delayed gamma-ray signature of 241 Pu, a significant fissile constituent in spent fuel, was measured and compared to 239 Pu. The 241 Pu/ 239 Pu ratios varied between 0.5 and 1.2 for ten prominent lines in the 2700-­3600 keV energy range. Such significant differences in relative peak intensities make it possible to determine relative fractions of these isotopes in a mixed sample. A method for determining fission product yields by fitting the energy and time dependence of the delayed gamma-­ray emission was developed and demonstrated on a limited 235 U data set. De-­convolution methods for determining fissile fractions were developed and tested on the experimental data. The use of high count-­rate LaBr 3 detectors was investigated as a potential alternative to HPGe detectors. Modeling capabilities were added to an existing framework and codes were adapted as needed for analyzing experiments and assessing application-­specific assay concepts. A de-­convolution analysis of the delayed gamma-­ray response spectra modeled for spent fuel assemblies was performed using the same method that was applied to the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation

Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study may help to stratify patients at risk for late effects to develop strategies to reduce frequency and severity of radiation sequelae.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implications of Voyager 1 observations beyond the heliopause for the local interstellar electron spectrum

Cosmic-ray observations made by the Voyager 1 spacecraft outside the dominant modulating influence of the heliosphere finally allow the comparison of computed galactic spectra with experimental data at lower energies. These computed spectra, based on galactic propagation models, can now be compared with observations at low energies by Voyager 1 and at high energies by the PAMELA space detector at Earth. This improves understanding of basic propagation effects and also provides solar modulation studies with reliable input spectra from 1 MeV to 100 GeV. We set out to reproduce the Voyager 1 electron observations in the energy range of 6-60 MeV, as well as the PAMELA electron spectrum above 10 GeV, using the GALPROP code. By varying the source spectrum and galactic diffusion parameters, specifically the rigidity dependence of spatial diffusion, we find local interstellar spectra that agree with both power-law spectra observed by Voyager 1 beyond the heliopause. The local interstellar spectrum between ∼1 MeV and 100 GeV indicates that it is the combination of two power laws, with E {sup –(1.45} {sup ±} {sup 0.15)} below ∼100 MeV and E {sup –(3.15} {sup ±} {sup 0.05)} above ∼100 MeV. A gradual turn in the spectral shape matching the power laws is found, between 2.0 ± 0.5) GeV and (100 ± 10) MeV. According to our simplified modeling, this transition is caused primarily by galactic propagation effects. We find that the intensity beyond the heliopause at 10 MeV is (350 ± 50) electrons m{sup –2} s{sup –1} sr{sup –1} MeV{sup –1}, decreasing to (50 ± 5) electrons m{sup –2} s{sup –1} sr{sup –1} MeV{sup –1} at 100 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm

Purpose: Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. Methods: An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered at points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. Results: The performances of the authors’ method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors’ method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors’ method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors’ method ranks 24 of 39. According to the index of the maximum shear stretch, the authors’ method is also efficient to describe the discontinuous motion at the lung boundaries. Conclusions: By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors’ method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.

60 APPLIED LIFE SCIENCES↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of imaging properties for submillimeter rectangular pinholes

Purpose: Recently, a multipinhole collimator with inserts that have both rectangular apertures and rectangular fields of view (FOVs) has been proposed for SPECT imaging since it can tile the projection onto the detector efficiently and the FOVs in transverse and axial directions become separable. The purpose of this study is to investigate the image properties of rectangular-aperture pinholes with submillimeter apertures sizes. Methods: In this work, the authors have conducted sensitivity and FOV experiments for 18 replicates of a prototype insert fabricated in platinum/iridium (Pt/Ir) alloy with submillimeter square-apertures. A sin{sup q}θ fit to the experimental sensitivity has been performed for these inserts. For the FOV measurement, the authors have proposed a new formula to calculate the projection intensity of a flood image on the detector, taking into account the penumbra effect. By fitting this formula to the measured projection data, the authors obtained the acceptance angles. Results: The mean (standard deviation) of fitted sensitivity exponents q and effective edge lengths w{sub e} were, respectively, 10.8 (1.8) and 0.38 mm (0.02 mm), which were close to the values, 7.84 and 0.396 mm, obtained from Monte Carlo calculations using the parameters of the designed inserts. For the FOV measurement, the mean (standard deviation) of the transverse and axial acceptances were 35.0° (1.2°) and 30.5° (1.6°), which are in good agreement with the designed values (34.3° and 29.9°). Conclusions: These results showed that the physical properties of the fabricated inserts with submillimeter aperture size matched our design well.

60 APPLIED LIFE SCIENCES↗

Multiscale and Machine Learning Modeling for Process-informed Microstructure Prediction in Additively Manufactured Materials Using MALAMUTE

Advanced Materials and Manufacturing Technologies (AMMT) program under the Department of Energy Office of Nuclear Energy, aims to develop and qualify additively-manufactured materials for nuclear applications. The key challenges to these efforts are the microstructural variabilities observed on the AM products and their impact on the properties and performance of the material in extreme environments. AMMT is using a combination of high-through-put experimental and modeling techniques to accelerate the qualification efforts. Conventionally, in-situ and ex-situ characterizations and testing are performed to correlate different aspects of the AM process to the final product and its performance. However, adopting a trial-and-error approach to experimentally evaluate the vast range of process parameters required to capture the microstructural variabilities is cost-prohibitive. Modeling and simulation provide a comparatively inexpensive way to understand and correlate the microstructural evolution to the processing conditions. The modeling and simulation work-packages within the AMMT program aims to use physics-based and machine learning modeling capabilities to develop a digital twin for AM that can correlate the process conditions to the final product and establish a process-structure-property-performance (PSPP) correlation for AM materials. The melting and subsequent solidification that occurs during the AM process is a complex phenomenon that requires multiscale multiphysics analysis. Idaho National Laboratory’s (INL) Multiphysics Object-Oriented Simulation Environment (MOOSE), specifically the MOOSE Application Library for Advanced Manufacturing UTilitiEs (MALAMUTE) software, provides an ideal platform for developing the multiphysics multiscale model to explore the intricacies of the microstructural evolution during the AM processes within a single framework. Furthermore, given that such full-fidelity simulations can be computationally intensive, reduced order models are necessary to explore the PSPP space for AM materials in an efficient, reliable, and cost-effective way. This work package focuses on understanding the role of process variabilities on the various microstructural characteristics of the AM materials. Microstructures unique to AM materials, such as compositional micro-heterogeneity and dislocation cells, are of particular interest here since they can influence the creep properties and radiation performance. In fiscal year (FY) 24, we significantly advanced upon our work in the last fiscal year, both on physics-based and ML models. The alloy solidification model available in MOOSE has been extended to incorporate the thermodynamic properties and free energy relevant to 316SS. The model demonstrates the Cr segregation that occurs during solidifcation. It is demonstrated that rate of solidification and solute segregation is primarily influence by the cooling rate dictating the level of freezing. This work captures the microstructural variabilities at the subgrain level that are often missing in the part-scale models. With an aim to connect the microstructural evolution model to realistic process conditions, a reduced order model is developed for predicting the thermal conditions around meltpool from high-fidelity process simulations. Furthermore, machine learning approach is used to accelerate the temperature prediction during the AM process. In the following years, MALAMUTE will be used to connect different aspects of the models and quantitatively predict the microstructural evolution. The developed ML-based surrogate model will consider the process conditions as the input to predict the microstructural features in a cost-effective way. The generated microstructures can be used by other work packages under AMMT to evaluate the properties and environmental response of the material at the mesoscale. Thus, this work help identify the key microstructural features at the subgrain level that are significant in property/performance prediction of the AM products. This work will provide inputs to the large-scale process variability models to reevaluate and validate assumptions/simplifications made in the part-scale models. Furthermore, through active learning this work will help identify the data need from both modeling and experimental sides for development of a robust digital twin for AM.

36 MATERIALS SCIENCE↗

Volume Flow Rate Estimation for Small Explosions at Mt. Etna, Italy, From Acoustic Waveform Inversion

Rapid assessment of the volume and the rate at which gas and pyroclasts are injected into the atmosphere during volcanic explosions is key to effective eruption hazard mitigation. Here, we use data from a dense infrasound network deployed in 2017 on Mt. Etna, Italy, to estimate eruptive volume flow rates (VFRs) during small gas-and-ash explosions. We use a finite-difference time-domain approximation to compute the acoustic Green's functions and perform a full waveform inversion for a multipole source, combining monopole and horizontal dipole terms. The inversion produces realistic estimates of VFR, on the order of 4 × 10 4 m 3 /s and well-defined patterns of source directivity. This is the first application of acoustic waveform inversion at Mt. Etna. Our results demonstrate that acoustic waveform inversion is a mature and robust tool for assessment of source parameters and holds potential as a tool to provide rapid estimates of VFR in near real time.

58 GEOSCIENCES↗

Characterization of geometrical factors for quantitative angle-resolved photoelectron spectroscopy

For conventional angle-resolved x-ray photoelectron spectroscopy (ARXPS), the area under the core-level peaks depends mainly on the in-depth distribution of chemical species at the top surface of a specimen. But the x-ray photoelectron spectroscopy (XPS) intensity is also affected by tool-related geometrical factors such as the shape of the x-ray beam, the spectrometer analysis volume, and the manipulator rotation axis. Data analysis is therefore typically based on normalization with respect to the signal from the substrate. Here, we present an original method to perform quantitative ARXPS without normalization, involving evaluation of these geometrical factors. The method is illustrated for a multiprobe XPS system using a methodology based on a specific software (XPSGeometry{sup Registered-Sign }), but is a general process that can be adapted to all types of XPS equipment, even those not specifically designed for ARXPS. In that case, this method enables bringing the sample as close as possible to the manipulator axis of rotation in order to perform automatic acquisitions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Failure-probability driven dose painting

Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of Organ Motion in Postoperative Endometrial and Cervical Cancer Patients Treated With Intensity-Modulated Radiation Therapy

Purpose: Intensity-modulated radiation therapy (IMRT) may be useful to reduce toxicity in gynecologic cancer patients requiring postoperative pelvic irradiation. This study was undertaken to quantify vaginal wall organ motion during the course of postoperative pelvic irradiation using pelvic IMRT. Methods and Materials: Twenty-two consecutive patients treated with postoperative pelvic IMRT on helical tomotherapy had fiducial markers placed at the vaginal apex prior to simulation then daily megavoltage computed tomography (CT) scans for positioning. The daily positions of the fiducials were registered and measured in reference to the initial CT scan to quantify the degree of vaginal wall organ motion during the entire course of therapy. Results: The total motion of the fiducials center of mass (COM) was a median of 5.8 mm (range, 0.6-20.2 mm), and 95% of all COM positions fell within 15.7 mm of their original position. Directional margins of 3.1 mm along the right-left axis, 9.5 mm along the superoinferior axis, and of 12.1 mm along the anteroposterior axis encompassed the vaginal fiducials in 95% of treatments. Mean organ deformation for all patients was 3.9 mm, (range, 0-27.5 mm; standard deviation, 3.1 mm), with significant distortions of greater than 10 mm in 17% of secondary image sets. Conclusions: These data suggest a planning target volume margin of 16 mm will account for maximal organ motion in the majority of gynecologic patients undergoing postoperative pelvic IMRT, and it may be possible to incorporate directional motion into the planning target volume margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗