Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Status of the RF BPM upgrade at the Advanced Photon Source.

The Advanced Photon Source (APS),a third-generation synchrotron light source, has been in operation for eleven years. The monopulse radio frequency (rf) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field-programmable gate array (FPGA) that performs the signal processing. A first-article system has been constructed and is currently being evaluated. This paper presents the results of testing of the first-article system as well as the progress made in other areas of this upgrade effort.

43 PARTICLE ACCELERATORS↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

An airborne study of microwave surface sensing and boundary layer heat and moisture fluxes for FIFE

The objectives of this work were to perform imaging radar and scatterometer measurements over the Konza Prairie as a part of the First International land surface climatology project Field Experiments (EIFE) and to develop an mm-wave radiometer and the data acquisition system for this radiometer. We collected imaging radar data with the University of Kansas Side-Looking Airborne Radar (SLAR) operating at 9.375 GHz and scatterometer data with a helicopter-mounted scatterometer at 5.3 and 9.6 GHz. We also developed a 35-GHz null-balancing radiometer and data acquisition system. Although radar images showed good delineation of various features of the FIFE site, the data were not useful for quantitative analysis for extracting soil moisture information because of day-to-day changes in the system transfer characteristics. Our scatterometer results show that both C and X bands are sensitive to soil moisture variations over grass-covered soils. Scattering coefficients near vertical are about 4 dB lower for unburned areas because of the presence of a thatch layer, in comparison with those for burned areas. The results of the research have been documented in reports, oral presentations, and published papers.

Gogineni, S. P.↗

High-Speed Automated Tester for Vacuum Chamber Feedthrough Connectors and Cables

The Goddard Space Flight Center's thermal vacuum laboratory has developed a high-speed automated system for testing the integrity of 37-pin MIL-C-5015 cylindrical electrical feedthrough connectors used on penetration plates of thermal vacuum chambers. The system consists of a desktop PC driving a data acquisition front end. The latter measures the resistance through each pin of the connector and the resistance from each pin to all other pins and the connector shell. In addition to identifying unacceptable feedthroughs, the system is also used for testing cables. In the special case of Type T thermocouples (used almost exclusively at the lab), the difference in resistance between the copper and constantan wires provides positive proof of accidentally reversed connector wiring. Data acquisition time to completely test a cable or feedthrough connector is less than thirty seconds. The system provides a hardcopy printout of the resistance readings. Connectors or cables with fewer wires are tested using simple adapter cables. Initial tests indicate that the performance of a given feedthrough connector can be predicted on the basis of measured resistance readings, reducing ongoing cost of connector replacement. The opportunity to positively certify the integrity of cables, cable connectors and feedthroughs before the start of a thermal vacuum test minimizes the likelihood of a circuit problem that would require returning the chamber to ambient conditions for repair. This system has two principal advantages for the Goddard thermal vacuum laboratory. Its only significant cost was the labor to fabricate the test cable and shorting cable -- about 40 man-hours total. The system was built around a computer and data acquisition unit that were already on hand. The second advantage is that it very quickly tests both of the parameters that are essential.

Swope, Robert H.↗

High performance real-time flight simulation at NASA Langley

In order to meet the stringent time-critical requirements for real-time man-in-the-loop flight simulation, computer processing operations must be deterministic and be completed in as short a time as possible. This includes simulation mathematical model computational and data input/output to the simulators. In 1986, in response to increased demands for flight simulation performance, personnel at NASA's Langley Research Center (LaRC), working with the contractor, developed extensions to a standard input/output system to provide for high bandwidth, low latency data acquisition and distribution. The Computer Automated Measurement and Control technology (IEEE standard 595) was extended to meet the performance requirements for real-time simulation. This technology extension increased the effective bandwidth by a factor of ten and increased the performance of modules necessary for simulator communications. This technology is being used by more than 80 leading technological developers in the United States, Canada, and Europe. Included among the commercial applications of this technology are nuclear process control, power grid analysis, process monitoring, real-time simulation, and radar data acquisition. Personnel at LaRC have completed the development of the use of supercomputers for simulation mathematical model computational to support real-time flight simulation. This includes the development of a real-time operating system and the development of specialized software and hardware for the CAMAC simulator network. This work, coupled with the use of an open systems software architecture, has advanced the state of the art in real time flight simulation. The data acquisition technology innovation and experience with recent developments in this technology are described.

Cleveland, Jeff I., II↗

ECON-T and ECON-D: Endcap Concentrator ASICs for the CMS HGCAL

With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.

Bergamin, G. [CERN] (ORCID:0000000285758704)↗

A method to provide rapid in situ determination of tip radius in dynamic atomic force microscopy

We provide a method to characterize the tip radius of an atomic force microscopy in situ by monitoring the dynamics of the cantilever in ambient conditions. The key concept is that the value of free amplitude for which transitions from the attractive to repulsive force regimes are observed, strongly depends on the curvature of the tip. In practice, the smaller the value of free amplitude required to observe a transition, the sharper the tip. This general behavior is remarkably independent of the properties of the sample and cantilever characteristics and shows the strong dependence of the transitions on the tip radius. The main advantage of this method is rapid in situ characterization. Rapid in situ characterization enables one to continuously monitor the tip size during experiments. Further, we show how to reproducibly shape the tip from a given initial size to any chosen larger size. This approach combined with the in situ tip size monitoring enables quantitative comparison of materials measurements between samples. These methods are set to allow quantitative data acquisition and make direct data comparison readily available in the community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Earthquake response of storey building in Jakarta using accelerographs data analysis

As seismotectonic, the Jakarta city will be greatly affected by the earthquake which originated from the subduction zone of the Sunda Strait and south of Java. Some occurrences of earthquakes in these location are often perceived by the occupants in the upper floors of multi-storey buildings in Jakarta but was not perceived by the occupants on the ground floor. The case shows the difference in ground-motion parameters on each floor height. The analysis of the earthquake data recorded by accelerographs on different floors need to be done to know the differences in ground-motion parameters. Data used in this research is accelerograph data installed on several floors in the main building of Meteorology Climatology and Geophysics Agency with a case study of Kebumen earthquake on January 25{sup th} 2014. Parameters analyzed include the Peak Ground Acceleration (PGA), Peak Ground Displacement (PGD), Peak Spectral Acceleration (PSA), Amplification (Ag), and the Effective Duration of earthquake (t{sub e}). Research stages include accelerographs data acquisition in three (3) different floors, conversion and data partition for each component, conversion to units of acceleration, determination of PGA, PGD, PSA, Ag and t{sub e} as well as data analysis. The study shows the value of PGA on the ground floor, 7{sup th} floor and 15{sup th} floors, respectively are 0.016 g, 0.053 g and 0.116 g. PGD on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 2.15 cm, 2.98 cm and 4.92 cm. PSA on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 0.067 g, 0.308 g and 0.836 g. Amplification of the peak acceleration value on the ground floor, 7{sup th} floor and 15{sup th} floor to the surface rock are 4.37, 6.07 and 7.30. Effective duration of the earthquake on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 222.28 s, 202.28 s and 91.58 s. In general, with increasing floor of the building, the value of the peak ground acceleration, peak ground displacement, peak spectral acceleration and amplification growing, contrary to the value of the effective duration of earthquake decreases. The difference in this parameter is strongly influenced by local soil conditions and building construction.

58 GEOSCIENCES↗

Speckle contrast diffuse correlation tomography of complex turbid medium flow

Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary data and, with further studies, a high potential for translatability to real tissues with arbitrary boundaries. A requisite correction was also found for measurements in the fashion of scDCT to recover accurate speckle contrast of deep tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA remote update for nuclear environments

The Instituto de Plasmas e Fusao Nuclear (IPFN) has developed dedicated re-configurable modules based on field programmable gate array (FPGA) devices for several nuclear fusion machines worldwide. Moreover, new Advanced Telecommunication Computing Architecture (ATCA) based modules developed by IPFN are already included in the ITER catalogue. One of the requirements for re-configurable modules operating in future nuclear environments including ITER is the remote update capability. Accordingly, this work presents an alternative method for FPGA remote programing to be implemented in new ATCA based re-configurable modules. FPGAs are volatile devices and their programming code is usually stored in dedicated flash memories for properly configuration during module power-on. The presented method is capable to store new FPGA codes in Serial Peripheral Interface (SPI) flash memories using the PCIexpress (PCIe) network established on the ATCA back-plane, linking data acquisition endpoints and the data switch blades. The method is based on the Xilinx Quick Boot application note, adapted to PCIe protocol and ATCA based modules. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decision-level Information Fusion to Assess Threat Likelihood in Shipped Containers

A significant challenge in the distribution of goods is assessing the potential threat that an individual shipping container poses. Due to the high volume of shipped goods, a primary concern is balancing accuracy and container scan time. The application of information fusion to the problem enables automated threat determination and the presentation of relevant data to an operator, in a decision support capacity, in order to maintain a sufficient level of processing. This paper outlines an approach to container threat assessment that combines data from multiple sources in order to reliably score the likelihood that a given container holds a threat. Fused data is also leveraged as a tool to optimize the routing of containers through a scanning system comprised of multiple data acquisition stations and providing data in multiple modes. Furthermore, we propose methods for the consolidated presentation of fused data to an operator in order to both minimize the time expended in container evaluation and maximize the accuracy of the assessment.

97 MATHEMATICS AND COMPUTING↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autonomous Control of Space Nuclear Reactors

Nuclear reactors to support future robotic and manned missions impose new and innovative technological requirements for their control and protection instrumentation. Long-duration surface missions necessitate reliable autonomous operation, and manned missions impose added requirements for failsafe reactor protection. There is a need for an advanced instrumentation and control system for space-nuclear reactors that addresses both aspects of autonomous operation and safety. The Reactor Instrumentation and Control System (RICS) consists of two functionally independent systems: the Reactor Protection System (RPS) and the Supervision and Control System (SCS). Through these two systems, the RICS both supervises and controls a nuclear reactor during normal operational states, as well as monitors the operation of the reactor and, upon sensing a system anomaly, automatically takes the appropriate actions to prevent an unsafe or potentially unsafe condition from occurring. The RPS encompasses all electrical and mechanical devices and circuitry, from sensors to actuation device output terminals. The SCS contains a comprehensive data acquisition system to measure continuously different groups of variables consisting of primary measurement elements, transmitters, or conditioning modules. These reactor control variables can be categorized into two groups: those directly related to the behavior of the core (known as nuclear variables) and those related to secondary systems (known as process variables). Reliable closed-loop reactor control is achieved by processing the acquired variables and actuating the appropriate device drivers to maintain the reactor in a safe operating state. The SCS must prevent a deviation from the reactor nominal conditions by managing limitation functions in order to avoid RPS actions. The RICS has four identical redundancies that comply with physical separation, electrical isolation, and functional independence. This architecture complies with the safety requirements of a nuclear reactor and provides high availability to the host system. The RICS is intended to interface with a host computer (the computer of the spacecraft where the reactor is mounted). The RICS leverages the safety features inherent in Earth-based reactors and also integrates the wide range neutron detector (WRND). A neutron detector provides the input that allows the RICS to do its job. The RICS is based on proven technology currently in use at a nuclear research facility. In its most basic form, the RICS is a ruggedized, compact data-acquisition and control system that could be adapted to support a wide variety of harsh environments. As such, the RICS could be a useful instrument outside the scope of a nuclear reactor, including military applications where failsafe data acquisition and control is required with stringent size, weight, and power constraints.

Merk, John↗

Temporal and spatial evolution of runaway electrons at the instability moments in Damavand tokamak

The time and position behavior of runaway electrons at the Parail–Pogutse instability moments has been investigated using experimental observations in plasma current, loop voltage, the Hard X-ray (HXR) radiations, and 18 poloidal pickup coils signals received by data acquisition system simultaneously. The conditional average sampling (CAS) method was used to analyze the output data. Moreover, a filament current code was modified to study the runaway electrons beam movement in the event of instabilities. The results display a rapid drift of runaway beam toward the inner wall of the vacuum vessel and the collision with the wall components at the instability moments. The existence of the collisions in these experiments is evident in the HXR bursts which are considered as the main trigger for CAS Analysis. Also, the variation of HXR bursts with the toroidal magnetic field shows that the hard X-ray bursts drop with increase in the toroidal magnetic field and runaway electrons confinement quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous motion scan ptychography: Characterization for increased speed in coherent x-ray imaging

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object’s complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous “fly-scan” mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.

43 PARTICLE ACCELERATORS↗

Rotorcraft Aeromechanics Branch Home Page on the World Wide Web

The tilt rotor aircraft holds great promise for improving air travel in the future. It's benefits include vertical take off and landing combined with airspeeds comparable to propeller driven aircraft. However, the noise from a tilt rotor during approach to a landing is potentially a significant barrier to widespread acceptance of these aircraft. This approach noise is primarily caused by Blade Vortex Interactions (BVI), which are created when the blade passes near or through the vortex trailed by preceding blades. The XV- 15 Aeroacoustic test will measure the noise from a tilt rotor during descent conditions and demonstrate several possible techniques to reduce the noise. The XV- 15 Aeroacoustic test at NASA Ames Research Center will measure acoustics and performance for a full-scale XV-15 rotor. A single XV-15 rotor will be mounted on the Ames Rotor Test Apparatus (RTA) in the 80- by 120-Foot Wind Tunnel. The test will be conducted in helicopter mode with forward flight speeds up to 100 knots and tip path plane angles up to +/- 15 degrees. These operating conditions correspond to a wide range of tilt rotor descent and transition to forward flight cases. Rotor performance measurements will be made with the RTA rotor balance, while acoustic measurements will be made using an acoustic traverse and four fixed microphones. The acoustic traverse will provide limited directionality measurements on the advancing side of the rotor, where BVI noise is expected to be the highest. Baseline acoustics and performance measurements for the three-bladed rotor will be obtained over the entire test envelope. Acoustic measurements will also be obtained for correlation with the XV-15 aircraft Inflight Rotor Aeroacoustic Program (IRAP) recently conducted by Ames. Several techniques will be studied in an attempt to reduce the highest measured BVI noise conditions. The first of these techniques will use sub-wings mounted on the blade tips. These subwings are expected to alter the size, strength, and location of the tip vortex, therefore changing the BVI acoustics of the rotor. The subwings are approximately 20% of the blade chord and increase the rotor radius by about 3 percent. Four different subwing configurations will be tested, including square tipped subwings with different angles of incidence. The ability of active controls to reduce BVI acoustics will also be assessed. The dynamic control system of the RTA will be used to implement open- and closed-loop active control techniques, including individual blade control. Open-loop testing will be conducted using a personal computer based, automated, real-time data acquisition system. This system features combined automated output of open loop control signals and automated data acquisition of the resulting test data. A final technique to alter the noise of the rotor will be examined. This will involve changing the number of blades from three to four. A four-bladed rotor hub has been fabricated on which the XV-15 blades will be mounted. While the solidity of the rotor will increase, much useful information can be gained by examining the changes in the thrust and RPM with four blades.

Peterson, Randall L.↗