Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIGESTIVE SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,299 records · Page 73

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field intercomparison of ice nucleation measurements: the Fifth International Workshop on Ice Nucleation Phase 3 (FIN-03)

Abstract. The third phase of the Fifth International Ice Nucleation Workshop (FIN-03) was conducted at the Storm Peak Laboratory in Steamboat Springs, Colorado, in September 2015 to facilitate the intercomparison of instruments measuring ice-nucleating particles (INPs) in the field. Instruments included two online and four offline measurement systems for INPs, which are a subset of those utilized in the laboratory study that comprised the second phase of FIN (FIN-02). The composition of the total aerosols was characterized using the Particle Analysis by Laser Mass Spectrometry (PALMS) and Wideband Integrated Bioaerosol Sensor (WIBS) instruments, and aerosol size distributions were measured by a laser aerosol spectrometer (LAS). The dominant total particle compositions present during FIN-03 were composed of sulfates, organic compounds, and nitrates, as well as particles derived from biomass burning. Mineral-dust-containing particles were ubiquitous throughout and represented 67 % of supermicron particles. Total WIBS fluorescing particle concentrations for particles with diameters of > 0.5 µm were 0.04 ± 0.02 cm−3 (0.1 cm−3 highest; 0.02 cm−3 lowest), typical of the warm season in this region and representing ≈ 9 % of all particles in this size range as a campaign average. The primary focus of FIN-03 was the measurement of INP concentrations via immersion freezing at temperatures > −33 °C. Additionally, some measurements were made in the deposition nucleation regime at these same temperatures, representing one of the first efforts to include both mechanisms within a field campaign. INP concentrations via immersion freezing agreed within factors ranging from nearly 1 to 5 times on average between matched (time and temperature) measurements, and disagreements only rarely exceeded 1 order of magnitude for sampling times coordinated to within 3 h. Comparisons were restricted to temperatures lower than −15 °C due to the limits of detection related to sample volumes and very low INP concentrations. Outliers of up to 2 orders of magnitude occurred between −25 and −18 °C; a better agreement was seen at higher and lower temperatures. Although the 5–10 factor agreement of INP measurements found in FIN-03 aligned with the results of the FIN-02 laboratory comparison phase, giving confidence in progress of this measurement field, this level of agreement still equates to temperature uncertainties of 3.5 to 5 °C that may not be sufficient for numerical cloud modeling applications that utilize INP information. INP activity in the immersion-freezing mode was generally found to be an order of magnitude or more, making it more efficient than in the deposition regime at 95 %–99 % water relative humidity, although this limited data set should be augmented in future efforts. To contextualize the study results, an assessment was made of the composition of INPs during the late-summer to early-fall period of this study inferred through comparison to existing ice nucleation parameterizations and through measurement of the influence of thermal and organic carbon digestion treatments on immersion-freezing ice nucleation activity. Consistent with other studies in continental regions, biological INPs dominated at temperatures of > −20 °C and sometimes colder, while arable dust-like or other organic-influenced INPs were inferred to dominate below −20 °C.

54 ENVIRONMENTAL SCIENCES↗

Characterization and CST Batch Contact Equilibrium Testing of Modified Tank 9H Process Supernate Samples in Support of TCCR

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with crystalline silicotitanate (CST) media to process radioactive waste solutions for the removal of ¹³⁷Cs. TCCR currently focuses on dissolving Savannah River Site (SRS) radioactive tank waste (primarily sodium saltcake solids) within Tank 10H followed by at-tank ion exchange column treatment. Two supernate batches from Tank 10H have been processed through the TCCR unit and processing of a third batch is expected soon. After processing of this supernate batch, plans are to replace the CST columns and process dissolved salt solution from Tank 9H through Tank 10H and then through the new CST columns installed in the TCCR unit. The new columns are expected to contain either a media similar to an archived CST batch (IE-911) or the R9120-B CST media used in the current TCCR columns (the two materials are fundamentally the same; just different specifications, product names, and preconditioning steps). Samples of Tank 9H dissolved saltcake were received at the Savannah River National Laboratory (SRNL) and characterized. The Tank 9H supernate contained a high sodium concentration (~9.6 M Na⁺) and will require dilution to near 6 M [Na⁺] prior to processing through the TCCR unit. The cesium concentration in Tank 9H is currently significantly higher than was observed with Tank 10H. Three dilutions of the Tank 9H supernate were conducted to mimic possible dilutions that could be conducted in the tank farm prior to TCCR processing using inhibited water, sodium hydroxide, and sodium nitrate solutions. Dilution #1 was prepared by diluting the Tank 9H supernate by a factor of 1.6 with inhibited water, Dilution #2 was prepared by diluting the Tank 9H supernate by a factor of 3.7 with a mixed sodium hydroxide/sodium nitrate diluent, and Dilution #3 was prepared by also diluting by a factor of 3.7 but with sodium hydroxide only. All three dilutions have similar Na⁺ concentrations (~6 M), but Dilutions #2 and #3 contain significantly less cesium. Major and key minor components of the diluted Tank 9H supernate samples are provided in Table ES-1. Batch contact equilibrium tests were conducted with the Tank 9H dilutions and the two different CST media batches being considered for use in the new TCCR columns. Results are summarized in Table ES-2 and compared to ZAM model predictions. The highest cesium distribution coefficient and percent removal were observed with Dilution #3. IE-911 CST (an archived CST media batch) was more effective at removing cesium than the more recently prepared R9120-B CST media, though both media samples removed >88% of the cesium and the differences may not be statistically different considering the overall uncertainty. Based on the results, maximum cesium loadings were calculated for each CST media type and Tank 9H dilution. In general, maximum cesium loadings from dilutions of this supernate batch are quite high (approaching 0.1 mmol total Cs⁺/g CST for Dilution #1). The highest calculated maximum ¹³⁷Cs loading for the Tank 9H dilutions using the ZAM model with input of the tank compositions and batch contact results was 207 Ci/kg CST (Dilution #1 with IE-911 CST). In all cases, higher maximum cesium loading values were predicted for IE-911 CST versus R9120-B, although the differences varied considerably between the dilutions. The maximum loading value for IE-911 CST with Tank 9H Dilution #1 was only 7% higher than the maximum loading for R9120-B. The maximum loading value for IE-911 CST with Dilution #3 was 24% higher than the maximum loading for R9120-B. Dilution #2 was intermediate between these values. Note that these maximum loading values are the theoretical calculated values, and actual operating conditions will cause differences. A CST binder dilution (correction) factor near 0.7 (relative to pure powder CST) was required for each batch contact test with IE-911 engineered CST using the three Tank 9H dilutions. Correction factors calculated for R9120-B CST ranged from 0.56 to 0.66 for the three dilutions. Following the batch contact tests, the CST samples were isolated from the Tank 9H solution, washed, dried, and digested in acid following established procedures. The analysis results are provided in Table ES-3. Total cesium loading values determined by CST digestion were similar to the calculated loading values based on solution analysis (Table ES-2) for all samples. In addition, the CST was observed to load calcium (R9120-B sample only), iron, strontium, lead, uranium, and plutonium after contact with the waste supernate, as has been observed previously.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗