Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Dynamic Model Agnostic Reliability Evaluation of Machine-Learning Models Integrated in Instrumentation & Control Systems

In recent years, the field of machine learning (ML), specifically neural networks, has grown significantly and has spurred research in its applicability to digital instrumentation and control systems (DI&C). While ML models have shown promise in operational contexts, the trustworthiness of using such algorithms has not been adequately assessed. Failures of ML integrated systems are not well understood, and the lack of comprehensive risk modeling can degrade the trustworthiness in these systems. In recent reports by the National Institute for Standards and Technology (NIST) [1] and the Nuclear Regulatory Commission (NRC) [2], they indicate that trustworthiness in ML is a critical barrier and will play a vital role in the safe, accountable, and secure operation of intelligent systems. Thus, in this work, we demonstrate a dynamic model-agnostic method to quantify the relative reliability of AI/ML predictions by incorporating out-of-distribution (OOD) detection on the training dataset. It is well documented that most ML algorithms excel at interpolation (or near-interpolation) tasks but experience significant performance degradation at extrapolation. The method, referenced as the Laplacian distributed decay for reliability (LADDR), determines the difference between the operational and training datasets which can used to the relative reliability of AI/ML predictions. LADDR is then demonstrated on a feedforward neural network based digital twin used for the prediction of safety significant factors during a loss-of-flow transient. LADDR is used to demonstrate how training data can be used as evidence to support the relative reliability of ML/AI predictions enhancing the overall trustworthiness of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance gain with low-enriched fuel and optimized use of neutrons

The most challenging type of reactors to convert to low-enriched fuel are high-flux research reactors, which, along with some spallation sources, are the most important neutron sources for modern neutron scattering experiments. Advanced Monte-Carlo computer codes are now available that make it possible to track neutrons from the reactor core, through neutron guides, to instruments and detectors. These 'virtual experiments' allow optimizing the performance of a research facility as a whole instead of the reactor alone. This article briefly reviews performance gains obtained for high-flux reactors during previous facility-upgrades. The Monte-Carlo code VITESS is used to compare results for typical neutron scattering experiments using obsolete versus state-of-the-art technologies. The analysis shows that performance gains due to instrument upgrades or neutron guide renewals dwarf potential neutron flux losses due to conversion to low-enriched fuel. Combined convert-and-upgrade strategies therefore offer unique opportunities for reactor operators and neutron instrument groups to significantly improve the overall performance of research facilities. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of energetic dual-energy detector efficiency using MCNP and GEANT Monte Carlo codes

The use of dual-energy detectors is a powerful tool in homeland security to identify materials atomic number in objects submitted to an X-ray analysis. In this work, the Monte Carlo methodology has been applied to study the response of a dual-energy lineal detector made of two scintillator materials, irradiated with a 160 KV photon spectrum emitted by an X-ray tube. To that, two different Monte Carlo codes have been used in the simulations, the MCNP5 and GEANT codes. The study of the energetic efficiency of a dual-energy detector has been developed by the simulation of several monoenergetic beams (10, 20,..., 160 KeV) oriented towards the detector, and registering the absorbed energy at both scintillators in each energy bin analyzed. Different configurations of scintillators materials and thickness have been simulated and the results show that a dual-energy detector formed GOS-CdWO{sub 4} scintillators materials is a good combination in order to separate the low energy part of the spectrum from the high energy part of it, obtaining as a result, two different images very useful for the identification of the effective atomic number of an irradiated object. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory of particle detection and multiplicity counting with dead time effects

The subject of this paper is the investigation of the effect of the dead time on the statistics of the particle detection process. A theoretical treatment is provided with the application of the methods of renewal theory. The detector efficiency and various types of the dead time are accounted for. Exact analytical results are derived for the probability distribution functions, the expectations and the variances of the number of detected particles. Explicit solutions are given for a few representative cases. The results should serve for the evaluation of the measurements in view of the dead time correction effects for the higher moments of the detector counts. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new flux map processing code for moveable detector system in PWR

This paper presents an introduction to the development of the flux map processing code MAPLE developed by China Nuclear Power Technology Research Institute (CNPPJ), China Guangdong Nuclear Power Group (CGN). The method to get the three-dimensional 'measured' power distribution according to measurement signal has also been described. Three methods, namely, Weight Coefficient Method (WCM), Polynomial Expand Method (PEM) and Thin Plane Spline (TPS) method, have been applied to fit the deviation between measured and predicted results for two-dimensional radial plane. The measured flux map data of the LINGAO nuclear power plant (NPP) is processed using MAPLE as a test case to compare the effectiveness of the three methods, combined with a 3D neutronics code COCO. Assembly power distribution results show that MAPLE results are reasonable and satisfied. More verification and validation of the MAPLE code will be carried out in future. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNM neutron detection using a time-gated synthetic aperture hybrid approach

This work focuses on using forward and adjoint transport in a hybrid application of 3-D deterministic (PENTRAN) and Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or 'channels, ' contain a unique set of moderators with 4 atm He-3 detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real time neutron spectroscopy for detecting special nuclear materials in moving vehicles. The initial design, detector response coupling, confirmation of initial design functionality using adjoint transport calculations, and realistic simulation using PENTRAN and MCNP5 are presented. Future work will include optimization and application to realistic scenarios and additional sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Assays Using a New Advanced Mathematical Algorithm - 12400

Current mathematical efficiency modeling software for in-situ counting, such as the commercially available In-Situ Object Calibration Software (ISOCS), typically allows the description of measurement geometries via a list of well-defined templates which describe regular objects, such as boxes, cylinder, or spheres. While for many situations, these regular objects are sufficient to describe the measurement conditions, there are occasions in which a more detailed model is desired. We have developed a new all-purpose geometry template that can extend the flexibility of current ISOCS templates. This new template still utilizes the same advanced mathematical algorithms as current templates, but allows the extension to a multitude of shapes and objects that can be placed at any location and even combined. In addition, detectors can be placed anywhere and aimed at any location within the measurement scene. Several applications of this algorithm to in-situ waste assay measurements, as well as, validations of this template using Monte Carlo calculations and experimental measurements are studied. Presented in this paper is a new template of the mathematical algorithms for evaluating efficiencies. This new template combines all the advantages of the ISOCS and it allows the use of very complex geometries, it also allows stacking of geometries on one another in the same measurement scene and it allows the detector to be placed anywhere in the measurement scene and pointing in any direction. We have shown that the template compares well with the previous ISOCS software within the limit of convergence of the code, and also compare well with the MCNPX and measured data within the joint uncertainties for the code and the data. The new template agrees with ISOCS to within 1.5% at all energies. It agrees with the MCNPX to within 10% at all energies and it agrees with most geometries within 5%. It finally agrees with measured data to within 10%. This mathematical algorithm can now be used for quickly and accurately evaluating efficiencies for wider range of gamma-ray spectroscopy applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of neutron and gamma fluxes in support to the interpretation of measuring devices irradiated in the core periphery of the OSIRIS Material Testing Reactor

Technological irradiations carried out in material testing reactors (MTRs) are used to study the behavior of materials under irradiation conditions required by different types of nuclear power plants (NPPs). For MTRs, specific instrumentation is required for the experiment monitoring and for the characterization of irradiation conditions, in particular the flux of neutrons and photons. To measure neutron and photon flux in experimental locations, different sensors can be used, such as SPNDs (self-powered neutron detectors), SPGDs (self-powered gamma detectors) and ionization chambers. These sensors involve interactions producing ultimately a measurable electric current. Various sensors have been recently tested in the core periphery of the OSIRIS reactor (located at the CEA-Saclay center) in order to qualify their responses to the neutron and the photon flux. One of the key input data for this qualification is to have a relevant evaluation of neutron and gamma fluxes at the irradiation location. The objective of this work is to evaluate the neutron and the gamma flux in the core periphery of the OSIRIS reactor. With this intention, specific neutron-photonic three-dimensional calculations have been performed and are mainly based on the TRIPOLI-4{sup R} three-dimensional continuous-energy Monte Carlo code, developed by CEA (Saclay Center) and extensively validated against reactor dosimetry benchmarks. In the case of the OSIRIS reactor, TRIPOLI-4{sup R} code has been validated against experimental results based on neutron flux and nuclear heating measurements performed in ex-core and in-core experiments. In this work, simultaneous contribution of neutrons and gamma photons in the core periphery is considered using neutron-photon coupled transport calculations. Contributions of prompt and decay photons have been taken into account for the gamma flux calculation. Specific depletion codes are used upstream to provide the decay-gamma sources required by TRIPOLI-4 calculations. In this paper, the neutron-photonic calculation scheme used for the neutron-gamma flux evaluation in the OSIRIS core periphery will be first detailed. Then, a comparison of calculated and measured values of neutron and gamma fluxes will be introduced. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Maximum Likelihood Expectation-Maximization Algorithms Applied to Localization and Identification of Radioactive Sources with Recent Coded Mask Gamma Cameras

In this work, we tested Maximum likelihood expectation-maximization (MLEM) algorithms optimized for gamma imaging applications on two recent coded mask gamma cameras. We respectively took advantage of the characteristics of the GAMPIX and Caliste HD-based gamma cameras: noise reduction thanks to mask/anti-mask procedure but limited energy resolution for GAMPIX, high energy resolution for Caliste HD. One of our short-term perspectives is the test of MAPEM algorithms integrating specific prior values for the data to reconstruct adapted to the gamma imaging topic. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An evaluation of in-line component process modules

The purpose of this paper is to discuss the analysis of abnormal configurations of in-line components, tanks and pumps in support of the integration of Criticality Safety into the Uranium Processing Facility (UPF) at Y-12 National Security Complex (Y-12). In-line components are components that are used in solution piping systems, including instrumentation, valves, pumps, and other general-use equipment. Mounted on self-contained skids/modules, in-line components (instruments, seal pots, level switches, etc.), tanks, and pumps are associated with a wide variety of the UPF processes. Using computer generated models expected to bound abnormal conditions for process module configurations, this report evaluates the impact of loss of spacing between in-line components in in-line component arrays and the effects of abnormal events. All fissile materials are considered to have a {sup 235}U enrichment of 100% and full theoretical density of 18.81 g/cm{sup 3} to conservatively represent the maximum credible enrichment available. Water and concrete were utilized to account for the construction materials associated with the skids and other reflective surfaces. Uranyl nitrate, was evaluated over the range of 0 to 550 g U/L for various normal and abnormal configurations of components mounted on skids. Abnormal events included fissile spills, sprinkler activation, and loss of spacing due to a seismic event. The results from this analysis provide a basis that supports development of nuclear safety design criteria, which generates standardized volume limits expected to bound the actual internal volume of the planned components. The results also provide a basis for consistent Nuclear Criticality Safety (NCS) control of in-line components, pumps, and tanks, for the ultimate development of Criticality Safety Process Studies in the UPF. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Automated Software Reliability Tester for Digital I and C

Existing nuclear facilities are in the process of upgrading analog systems to new, software- based digital components; however, the qualification of these new systems has been a significant hurdle for their implementation in the United States. This paper describes the development of a Software Reliability Tester (SRT) that will provide a means to quantify the reliability and fault tolerance of digital instrumentation and control (I and C) systems used in nuclear facilities. The SRT is comprised of hardware and software that exercise digital equipment inputs and compare the outputs to expected values to quantify system reliability. Incorporation of fault injection techniques enables the SRT to evaluate the robustness of digital I and C in the presence of abnormal conditions. The integration of both quantitative reliability and fault tolerance measures will provide the nuclear industry with an automated and systematic approach to digital I and C qualification. This will enable safer, more reliable, and more cost effective implementations of a broad spectrum of digital I and C equipment in existing and next generation nuclear facilities. This paper includes a description of the design of the SRT, including software modules and the hardware interface. In addition, an example of using the SRT to automate functional testing of a digital timer relay is presented. The SRT described in this paper provides a means to conduct efficient and robust testing for a variety of digital devices. Future plans for the SRT include integrating fault injection testing so that devices can be evaluated in the presence of off-normal conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Dependability for Digital Instrumentation and Control Systems in Nuclear Power Plants - Lessons Learnt from a DOE Sponsored Project

This paper discusses the lessons learnt from a sponsored study undertaken under the sponsorship of the Department of Energy by a team of scientists at the Ohio State University in collaboration with Technology Resources and experts around the world. This paper makes recommendations for future research and studies based on these lessons learnt. The purpose of the research was to provide a software dependability quantification framework that would allow its evaluation along the software development life cycle for safety critical instrumentation and control systems (I and C) such as those found in nuclear power plants. A typical example of safety critical system is the reactor protection system. The research funded by the Department of Energy built on preliminary research carried out for the US NRC that had focused solely on software reliability quantification. Quantification of software dependability is important for safety critical I and C because the regulatory framework in use in the United States for nuclear power plants is risk informed. Quantification of risk requires quantification of all contributors to risk and those include instrumentation and control systems. The purpose of the study was to help developers of software-based I and C with an early evaluation of the potential risk an application would represent at different stages of the software development life cycle by building gates at the end of each life cycle phase. Life cycle phases of software development comprehend phases such as requirements, design, coding and test. The gates' function would be to stop development from moving forward if the assessed dependability objective for that phase were not met. Gates thresholds were to be defined based on measurements collected during the life cycle phase under evaluation and phases that preceded it and an understanding of the mechanisms that would lead to threatening the dependability objectives. The information contained in the gates would in addition help steer the development towards areas that needed improvement. The following are four high level conclusions to our study. First the study demonstrates a lack of consensus on mechanisms that will threaten the dependability attributes. This lack of consensus should be resolved. The lack of consensus appears for all measures to the exception of reliability. Second, measures should be developed for software availability and safety. Third, for all dependability attributes (with the exception of reliability) consistency of the measurement threads should evaluated and measurement-based development gates derived. Finally our ability to perform such type of research depends in a significant manner on access to vendor and/or utility data. The licensing environment and the first-of-a-kind nature of current software-based applications for nuclear I and C make it difficult to collect the relevant data. An approach which would either increase access to data by providing 'immunity' to the vendor or utility or the development of a software-based I and C for the sole purpose of data collection for research should be investigated. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependability Assessment of Software for Safety Instrumentation and Control Systems

In its 2013 recommendations to the International Atomic Energy Agency (IAEA), the Technical Working Group on Nuclear Power Plant Instrumentation and Control (TWG-NPPIC) identified assessment and evaluation of software dependability as a topic of interest for IAEA Member States. To implement the recommendation of the TWG-NPPIC, the IAEA Scientific Secretary for the TWG initiated a consultancy activity in 2014 to develop a technical report describing a dependability assessment framework suitable for safety instrumentation and control (I and C) systems in nuclear power plants (NPPs). The development of the software dependability assessment report has involved three consultancy meetings at IAEA headquarters in Vienna, Austria. The conduct of these meetings allowed consultation among subject matter experts to generate consensus technical information that serves as the content of the report. The technical contributors consist of international experts from academia, industry, regulatory bodies and research organizations. In September 2014, a technical meeting was held in Daejeon, Republic of Korea, to present interim findings of the consultancy effort and to solicit input from representatives of IAEA Member States. The information and technical comments contributed during the technical meeting were addressed in subsequent development of the report. This paper gives an overview of key technical elements of the IAEA report. The IAEA report presents a framework by which a dependability assessment of safety software can be performed. The specified guiding principles provide the basis for establishing an assessment strategy and implementing the assessment process. The assessment framework provides a systematic, coherent structure within which to organize technical and process evidence to satisfy arguments in support of claims about software dependability properties. During the consultancy activity, the participating subject matter experts focused on high level principles, a structured approach, and identification of suitable methods and techniques. However, it was recognized that what remains is to concretize the framework through specific examples and usage experience. Thus, following publication of the report, it is recommended that case studies be performed to illustrate and more precisely define specific phases and elements of the assessment framework. For example, current national assessment approaches could be mapped into the assessment framework to serve as case studies and help to identify any aspects of the assessment framework that needs further definition or adjustment. Additionally, a challenge problem could be defined to engage stakeholders to apply the assessment framework with a common focus. This could help to better illustrate strategic options and approaches to the assessment phases. It also could serve to suggest other considerations and potential sources of evidence not fully covered in the report. Based on findings from case studies, challenge problems and country experience, it should be possible to develop generalized templates to support application of the assessment framework. These findings can be collected to serve as the basis for a User's Guide on dependability assessment of safety software. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Criteria for Hardware Descripted Language Programmed-Devices for Safety Systems in Nuclear Power Plants in the U.S

The U.S. Nuclear Regulatory Commission (NRC) is in the process of developing a regulatory guide (RG) describing a method the staff of the NRC considers acceptable, for use in complying with NRC regulations with respect to the development of hardware description language-programmed device (HPD). Examples include: field programmable gate arrays (FPGAs), systems in the power, instrumentation, and control portions of safety systems for nuclear power plants. The regulatory framework that NRC is establishing for nuclear power plants consists of a number of regulations and supporting guidelines applicable to the development of HPD-based safety systems. The NRC issues RGs to describe to the public, methods that the NRC staff considers acceptable for use in implementing specific parts of the agency's regulations; to explain techniques that the NRC staff uses in evaluating specific problems or postulated accidents; and to provide guidance to applicants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Solid Angle for a Spherical Surface Source and a Detector with an Arbitrary Aperture: An Elegant Proof

It has previously been proven that the solid angle (or geometry factor, also called the geometrical efficiency) for a spherically symmetric outward-directed surface source with an arbitrary radius and polar angle distribution and an arbitrary detector aperture is equal to the solid angle for an isotropic point source located at the center of the spherical surface source and the same detector aperture. The solid angle for a source-detector system is the fraction of source particles that enter the detector aperture and so it is not purely geometric-the angular distribution of the source is a factor. The previous proof relied on an analytic transport-theory (streaming only) calculation of the solid angle Ω for a spherically symmetric surface source and a point detector. In this paper, a new, more elegant proof is given. Since the net current across any portion of a plane that intersects the center of a spherical surface source is zero, the solid angle for a spherical surface source with any polar angle distribution and a uniform azimuthal angle distribution and any detector aperture is equal to the solid angle for an isotropic point source and the same detector. This insight obviates the calculus and trigonometry involved in the previous proof. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient Mass Spectrometer Data Analysis Pipeline Development

The ability to detect chemical + isotopic information for trace actinide samples is currently not available at SRNL. This negatively impacts our ability to explore, develop, and characterize signatures of nonproliferation interest. Paper spray ionization mass spectrometry (PSIMS) is a novel ambient mass spectrometry technique that promises to rectify this issue. PSI-MS produces copious amounts of data; thus, a data analysis pipeline is necessary to quickly extract meaningful results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension of mutation testing for the requirements and design faults - 322

Mutation Testing is a fault-based software testing technique that is considered to be the most efficient in detecting faults. It focuses on the software code level and follows a set of rules which are called mutation operators to systematically seed faults into the source code. Each seeded fault results is a new version of the software, which is called a mutant. Mutation testing promises to be effective in identifying adequate test data which can be used to find faults in the source code. However, traditional mutation testing is not geared towards the detection of requirements and design faults. To cover the full spectrum of possible faults, the mutation framework has been extended from the code level to the requirements and design level. Twenty-nine defects that appear in requirements and design documents were identified to define appropriate mutants. Then corresponding mutation operators that model the defects were developed. For each mutation operator, the strategy to generate a mutant and the evaluation of the number of possible mutants were defined. Existing code level cost reduction techniques were tailored for requirements and design mutation operators that result in a large number of mutants. With the extended mutation testing framework, the full spectrum of possible faults will be tested and identified to ensure the safety and functionality of the software. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗