Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

First measurement of lifetimes in the yrast band of {sup 100}Pd

Lifetimes of the yrast states up to 12{sup +} and of a negative parity 5{sup -} state in {sup 100}Pd were measured by means of the recoil distance Doppler shift technique. The experiment was performed at the Cologne FN Tandem accelerator with the Cologne Plunger using the reaction {sup 92}Mo({sup 11}B,p2n) to populate excited states in {sup 100}Pd. Lifetimes were determined by analyzing the transitions in coincidence mode employing the differential decay curve method. The obtained E2 transition strengths were compared to predictions from collective models and the shell model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner

The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 10 12 photons s −1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s −1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

43 PARTICLE ACCELERATORS↗

Flight response of slope‐soaring birds to seasonal variation in thermal generation

Summary Animals respond to a variety of environmental cues, including weather conditions, when migrating. Understanding the relationship between weather and migration behaviour is vital to assessing time‐ and energy limitations of soaring birds. Different soaring modes have different efficiencies, are dependent upon different types of subsidized lift and are weather dependent. We collected GPS locations from 47 known‐age golden eagles that moved along 83 migration tracks. We paired each location with weather to determine meteorological correlates of migration during spring and fall as birds crossed three distinct ecoregions in north‐east North America. Golden eagle migration was associated with weather conditions that promoted thermal development, regardless of season, ecoregion or age. Eagle migration showed age‐ and season‐specific responses to weather conditions that promoted orographic lift. In spring, adult eagles migrated earlier, over fewer days, and under more variable weather conditions than did pre‐adults, suggesting that adults were time limited and pre‐adults made choices to conserve energy. In fall, we found no difference in the time span of migration or when each age class migrates; however, we saw evidence that pre‐adults were less efficient migrants than adults. The decision by soaring birds to migrate when thermals developed allowed individuals to manage trade‐offs between migratory speed and migratory efficiency. When time was limited (i.e. spring movement of adults speeding towards nesting territories), use of whatever lift was available decreased the time span of migration. When migration was not time limited (e.g. spring movements by pre‐adults, all movements in fall), eagles avoided suboptimal flight conditions by pausing migration, thus increasing the time span of migration while reducing energetic costs.

Duerr, Adam E.↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

Performance Validation of Advanced PHEV Vehicle

Summary of Major Accomplishments: Chrysler developed a PHEV minivan as part of a DOE contract to develop a production-ready PHEV prototype. Although conventional certification tests were conducted by Chrysler during their development, Argonne was brought in at the end of the development project to run their research-oriented benchmark testing on one of the prototype vehicles. Here are the accomplishments: Prototype vehicle was instrumented by removing some panels and installing voltage and current probes; Other signals such as temperature and setting up CAN network data collection; 42 drive cycle tests were run on the 4WD chassis dynamometer, in both CD and CS modes over UDDS, US06, HWY, SC03 cycles, and research cycles including steady-state

33 ADVANCED PROPULSION SYSTEMS↗

Total Ambient Ion Count using Atmosphere Pressure Interface Time of Flight (APITOF) Mass Spectrometer

These files contain unit mass resolution data for selected masses measured by an atmospheric pressure interface time-of-flight mass spectometer (APi-ToF) during the 2016 Holistic Interactions of Shallow Clouds Aerosols and Land Ecosystems (HI-SCALE) campaign at the Atmospheric Radiation Measurement Southern Great Plains site. Data for selected ambient ions are presented. Measurements were collected between 2016 August 29 and 2016 September 23. The instrument was switched between positive and negative mode approximately every 24 hours. Positive and negative data are contained in separate files. Files are in ICARTT format.

54 ENVIRONMENTAL SCIENCES↗

Mean sea level determination from satellite altimetry

The primary experiment on the Geodynamics Experimental Ocean Satellite-3 (GEOS-3) is the radar altimeter. This experiment's major objective is to demonstrate the utility of measuring the geometry of the ocean surface; i.e., the geoid. Results obtained from this experiment so far indicate that the planned objectives of measuring the topography of the ocean surface with an absolute accuracy of + or - 5 m can be met and perhaps exceeded. The GEOS-3 satellite altimeter measurements have an instrument precision in the range of + or - 25 cm to + or - 50 cm when the altimeter is operating in the 'short pulse' mode. After one year's operations of the altimeter, data from over 5000 altimeter passes have been collected. With the mathematical models developed and the altimeter data presently available, mapping of local areas of ocean topography has been realized to the planned accuracy levels and better. This paper presents the basic data processing methods employed and some interesting results achieved with the early data. Plots of mean sea surface heights as inferred by the altimeter measurements are compared with a detailed 1 by 1 deg gravimetric geoid.

Kahn, W. D.↗

Laboratory testing and modeling to evaluate perfluorocarbon compounds as tracers in geothermal systems

The thermal stability and adsorption characteristics of three perfluorinated hydrocarbon compounds were evaluated under geothermal conditions to determine the potential to use these compounds as conservative or thermally-degrading tracers in Engineered (or Enhanced) Geothermal Systems (EGS). The three compounds tested were perfluorodimethyl-cyclobutane (PDCB), perfluoromethylcyclohexane (PMCH), and perfluorotrimethylcyclohexane (PTCH), which are collectively referred to as perfluorinated tracers, or PFTs. Two sets of duplicate tests were conducted in batch mode in gold-bag reactors, with one pair of reactors charged with a synthetic geothermal brine containing the PFTs and a second pair was charged with the brine-PFT mixture plus a mineral assemblage chosen to be representative of activated fractures in an EGS reservoir. A fifth reactor was charged with deionized water containing the three PFTs. The experiments were conducted at {approx}100 bar, with temperatures ranging from 230 C to 300 C. Semi-analytical and numerical modeling was also conducted to show how the PFTs could be used in conjunction with other tracers to interrogate surface area to volume ratios and temperature profiles in EGS reservoirs. Both single-well and cross-hole tracer tests are simulated to illustrate how different suites of tracers could be used to accomplish these objectives. The single-well tests are especially attractive for EGS applications because they allow the effectiveness of a stimulation to be evaluated without drilling a second well.

02 PETROLEUM↗

First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dust Studies in DIII-D Tokamak

Studies of submicron dust using Mie scattering from Nd:YAG lasers and video data of micron to sub-millimeter sized dust on DIII-D tokamak have provided the first data of dust sources and transport during tokamak discharges. During normal operation on DIII-D dust observation rates are low, a few events per discharge or less. The net carbon content of the dust corresponds to a carbon atom density a few orders of magnitude below the core impurity density. Statistical analysis of Mie data collected over months of operation reveal correlation of increased dust rate with increased heating power and impulsive wall loading due to edge localized modes (ELMs) and disruptions. Generation of significant amounts of dust by disruptions is confirmed by the camera data. However, dust production by disruptions alone is insufficient to account for estimated in-vessel dust inventory in DIII-D. After an extended entry vent, thousands of dust particles are observed by cameras in the first 2-3 plasma discharges. Individual particles moving at velocities up to {approx}300 m/s, breakup of larger particles into pieces, and collisions of particles with walls are observed. After {approx}70 discharges, dust levels are reduced to a few events per discharge. In order to calibrate diagnostics and benchmark modeling, milligram amounts of micron-sized carbon dust have been injected into DIII-D discharges, leading to the core carbon density increase by a factor of 2-3. Following injection, dust trajectories in the divertor are mostly in the toroidal direction, consistent with the ion drag force. Dust from the injection is observed in the outboard midplane by a fast framing camera. The observed trajectories and velocities of the dust particles are in qualitative agreement with modeling by the 3D DustT code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

Measurement of the b-hadron production cross section using decays to {mu}{sup -}D{sup 0}X final states in pp collisions at {radical}(s)=1.96 TeV

We report a measurement of the production cross section for b hadrons in pp collisions at {radical}(s)=1.96 TeV. Using a data sample derived from an integrated luminosity of 83 pb{sup -1} collected with the upgraded Collider Detector (CDF II) at the Fermilab Tevatron, we analyze b hadrons, H{sub b}, partially reconstructed in the semileptonic decay mode H{sub b}{yields}{mu}{sup -}D{sup 0}X. Our measurement of the inclusive production cross section for b hadrons with transverse momentum p{sub T}>9 GeV/c and rapidity |y|<0.6 is {sigma}=1.30 {mu}b{+-}0.05 {mu}b(stat){+-}0.14 {mu}b(syst){+-}0.07 {mu}b(B), where the uncertainties are statistical, systematic, and from branching fractions, respectively. The differential cross sections d{sigma}/dp{sub T} are found to be in good agreement with recent measurements of the H{sub b} cross section and well described by fixed-order next-to-leading logarithm predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rayleigh criterion and acoustic energy balance in unconfined self-sustained oscillating flames

Instabilities of confined combustion systems are often discussed in terms of the Rayleigh criterion, which provides a necessary condition for unstable operation and is commonly used to distinguish driving and damping regions. The analysis is also carried out in some cases by making use of an acoustic energy balance in which the Rayleigh term acts as a source. The case of unconfined flames is less well documented but of importance in practical systems used in heating and drying. This study is motivated by problems of self-sustained oscillations of radiant burners for domestic or industrial processes and of various other types of open flames. Application of the Rayleigh criterion and of the balance of acoustic energy to oscillations arising in such unconfined systems is examined. The objective is to see if the Rayleigh condition is fulfilled and to show how the different perturbed variables are linked to each other to develop an unstable oscillation. These issues are investigated by experiments in two geometries. The first case relates to a single ''V''- or ''M''-shaped flame formed by a burner behaving like a Helmholtz resonator. The second geometry features a collection of conical flames (CCF) established by a multipoint injector. This system is fed by a manifold that features a set of plane modes and resonates like an organ pipe at frequencies corresponding to odd multiples of the quarter wave. The Rayleigh criterion and a related result written in the form of an acoustic energy balance are used to define conditions of instability. A link is established between the pressure signal radiated by the burner and the total heat release rate perturbation yielding the phase lag between these two variables and providing conditions for unstable operation. Systematic experiments carried out in the two burner geometries and model predictions are in good agreement indicating that the Rayleigh source term is positive and that the criterion is well fulfilled by the wavefield component corresponding to the pressure radiated back by the resonator. The gain and loss terms in the acoustic energy budget are estimated in one typical case, indicating that the source term is balanced by the acoustic power radiated away from the flame region, while dissipation of acoustic energy in the burner is shown to be essentially negligible. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cloud Retrieval Intercomparisons Between SEVIRI, MODIS and VIIRS with CHIMAERA PGE06 Data Collection 6 Products

The Cross-platform HIgh resolution Multi-instrument AtmosphEric Retrieval Algorithms (CHIMAERA) system allows us to perform MODIS-like cloud top, optical and microphysical properties retrievals on any sensor that possesses a minimum set of common spectral channels. The CHIMAERA system uses a shared-core architecture that takes retrieval method out of the equation when intercomparisons are made. Here we show an example of such retrieval and a comparison of simultaneous retrievals done using SEVIRI, MODIS and VIIRS sensors. All sensor retrievals are performed using CLAVR-x (or CLAVR-x based) cloud top properties algorithm. SEVIRI uses the SAF_NWC cloud mask. MODIS and VIIRS use the IFF-based cloud mask that is a shared algorithm between MODIS and VIIRS. The MODIS and VIIRS retrievals are performed using a VIIRS branch of CHIMAERA that limits available MODIS channel set. Even though in that mode certain MODIS products such as multilayer cloud map are not available, the cloud retrieval remains fully equivalent to operational Data Collection 6.

cloud retrieval↗

Search for B + → e + ν e and B + → μ + ν μ decays using hadronic tagging

We present a search for the rare leptonic decays B + → e + ν e and B + → μ + ν μ , using the full Υ(4S) data sample of 772 × 10 6 BB¯ pairs collected with the Belle detector at the KEKB asymmetric-energy e + e – collider. One of the B mesons from the Υ(4S) → BB¯ decay is fully reconstructed in a hadronic mode, while the recoiling side is analyzed for the signal decay. Here, we find no evidence of a signal in any of the decay modes. Upper limits of the corresponding branching fractions are determined as B(B + → e + ν e ) < 3.5 × 10 –6 and B(B + → μ + ν μ ) < 2.7 × 10 –6 at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Collective strong coupling with homogeneous Rabi frequencies using a 3D lumped element microwave resonator

We design and implement 3D-lumped element microwave cavities that spatially focus magnetic fields to a small mode volume. They allow coherent and uniform coupling to electron spins hosted by nitrogen vacancy centers in diamond. We achieve large homogeneous single spin coupling rates, with an enhancement of more than one order of magnitude compared to standard 3D cavities with a fundamental resonance at 3 GHz. Finite element simulations confirm that the magnetic field distribution is homogeneous throughout the entire sample volume, with a root mean square deviation of 1.54%. With a sample containing 10{sup 17} nitrogen vacancy electron spins, we achieve a collective coupling strength of Ω = 12 MHz, a cooperativity factor C = 27, and clearly enter the strong coupling regime. This allows to interface a macroscopic spin ensemble with microwave circuits, and the homogeneous Rabi frequency paves the way to manipulate the full ensemble population in a coherent way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗