Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONNECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Lanthanide and actinide extractions using functionalized cobalt bis(dicarbollide) ion derivatives substituted with metal ligating functions

Several extractants based on cobalt bis(dicarbollide) ion of formula [(1,2-C{sub 2}B{sub 9}H{sub 10})(1',2'- C{sub 2}B{sub 9}H{sub 11})-3,3'-Co(III)]{sup -} with covalently bonded CMPO group of general formulation [(Ph){sub 2}P(0)(CH{sub 2})C(0)N(H){sub n=0,1}] were prepared and tested for extraction of trivalent radionuclides. The compounds studied differ in mode of attachment of CMPO group to COSAN moiety. Compound 1 with diethylene glycol connector between the COSAN cage and CMPO group provided better extraction properties than compounds with direct attachment (2) and N-bridge connection of COSAN moiety to nitrogen of CMPO group (3a or 3b). The compounds allowed the use of a less-polar solvent mixture of hexyl-methylketone and n-dodecane, which could replace the polar and less environmentally friendly solvent nitrobenzene.

07 ISOTOPE AND RADIATION SOURCES↗

Synthesis, structure and fluorescence of novel cadmium(II) and silver(I) complexes with in situ ligand formation of 1-(5-tetrazolyl)-4-(imidazol-1-ylmethyl)benzene

Hydrothermal reactions of cadmium(II) or silver(I) salt, NaN{sub 3}, 4-(imidazol-1-ylmethyl)benzonitrile (IBN) yield three coordination complexes, [Cd(L){sub 2}(H{sub 2}O){sub 2}].3H{sub 2}O (1), [Cd{sub 3}(L){sub 5}(OH)] (2) and [Ag{sub 2}(L){sub 2}] (3) where HL=1-(5-tetrazolyl)-4-(imidazol-1-ylmethyl)benzene. The crystal structure analysis revealed that 1 has 1D hinged-chain structure containing 24-membered ring with a Cd...Cd intra-chain distance of 13.18 A, while 2 is 1D ladder-like chain with Cd{sub 3}O core. However, the complex 3 is a 3D 4-connected framework with Schlaefli symbol of (4{sup 2}.6{sup 3}.8)(4{sup 3}.6{sup 2}.8). The L{sup -} ligand was found to show four different coordination modes in 1-3, as 2-, 3- and 4-connector, respectively. The results indicate that the coordination modes of the ligand and metal centers with different coordination geometry have great influence on the structures of the complexes. In addition, the photoluminescence of the complexes were studied in the solid state at room temperature. - Graphical abstract: Three novel coordination polymers were obtained with in situ ligand formation through Sharpless's [3+2] reaction. The structure and luminescence properties of the complexes were investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Syntheses, structures and properties of silver(I) complexes with flexible 1,3,5-tris(pyridylmethoxyl)benzene ligands

Five new silver(I) complexes [Ag{sub 2}(L{sub 2}){sub 2}](BF{sub 4}){sub 2}.CH{sub 3}CN.CH{sub 3}OH (1), [Ag(L{sub 2})(CF{sub 3}SO{sub 3})] (2), [Ag(L{sub 3})]ClO{sub 4}.CH{sub 3}OH (3), [Ag{sub 2}(L{sub 3}){sub 2}](CF{sub 3}SO{sub 3}){sub 2}.CH{sub 3}CN.CH{sub 3}OH.H{sub 2}O (4) and [Ag(L{sub 3})]PF{sub 6}.2CH{sub 3}CN (5) [L{sub 2}=1,3,5-tris(2-pyridylmethoxyl)benzene, L{sub 3}=1,3,5-tris(3-pyridylmethoxyl)benzene] were synthesized and characterized by single crystal X-ray diffraction analyses. In complexes 1-5, ligands L{sub 2} and L{sub 3} show different conformations and act as three-connectors, while the Ag(I) atom serves as three-connecting node to result in the formation of 2D and 3D frameworks. Complexes 1 and 2 with different counteranions have similar 2D network structure with the same (4,8{sup 2}) topology. Complex 3 has a 3D structure with (10,3)-a topology while complexes 4 and 5 have the same 2D (6,3) topological structure. The results showed that the structure of organic ligands and counteranions play subtle but important role in determining the structure of the complexes. In addition, the photoluminescence and anion-exchange properties of the complexes were investigated in the solid state at room temperature. - Graphical abstract: Five new silver(I) coordination frameworks with different topology were obtained and their structures were determined by single crystal X-ray diffraction studies. The influence of counteranion and ligand on the structure of complexes was discussed, the photoluminescence and anion-exchange properties were reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techniques for controlling charging and/or discharging of batteries using a tanks-in-series model

In some embodiments, a battery management system is provided. The battery management system comprises a connector for electrically coupling a battery to the battery management system, at least one sensor configured to detect a battery state, a programmable chip configured to control at least one of charging and discharging of the battery, and a controller device. The controller device is configured to receive at least one battery state from the at least one sensor; provide the at least one battery state as input to a tanks-in-series model that represents the battery; and provide at least one output of the tanks-in-series model to the programmable chip for controlling at least one of charging and discharging of the battery.

25 ENERGY STORAGE↗

Expandable systems for space

Systems for insulating a space vehicle or space borne container from an external environment as well as cryogens from heat sources. Such systems also protect the vehicle from the high dynamic pressures, the high heat loads encountered in atmospheric flight, and provide storage capability that strongly limits, or effectively eliminates, cryogenic boil-off losses once in space. Such systems include an expandable structure having a plurality of contiguously adjacent expandable layers. The layers are connected by a plurality of tension connectors between successive layers. For launch and flight the layers can be restrained in a collapsed position. Whereupon exiting a free stream environment, the layers are expanded where they can lock into place or otherwise remain in an expanded state. The expansion creates separation between the layers with minimal conduction paths providing near theoretically perfect multi-layer insulation and extremely effective debris protection.

de Jong, Maxim↗

Apparatus and method for high density detachable electrical interface

The present disclosure relates to a high density electrical interconnect apparatus for interfacing with remotely located electrical components. The apparatus may have a housing, a substrate element supported within the housing, and a plurality of independent substrate interface connect subsystems arranged in a planar grid on the substrate element. The apparatus further has a plurality of independent electrical interface connector subassemblies, each configured to be coupled to an associated subplurality of the substrate interface connect subsystems, to form a plurality of electrical communication channels with the remotely located electrical components.

Patra, Susant↗

Development of Wireless Data Transmission System for the Monitoring in Geological Disposal of Radioactive Waste - 12063

The authors have been developing a wireless data transmission system to monitor the performance of a geological disposal system for radioactive waste. The system's concepts, advantages, and a recent development focused on reducing transmitter size to suit narrow spaces such as bentonite buffers and boreholes. A wireless transmitter with a built-in temperature sensor and a connector for external sensors has been developed, measuring 130 mm in length and 50 mm in diameter. The capability of the transmitter was confirmed by transmission tests on the ground and in a bentonite block. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A nano-structured ZnO film as diagnostic X-ray sensor

Currently some international organizations such as WHO and IAEA have shown concerns about the quality of diagnostic services in clinics and hospitals that use ionizing radiation. In fact, the IAEA recommend that the characteristics of the X-ray beam must be adjusted to obtain the highest quality of the radiographic image with the minimum exposure to the patient. Several types of detectors may be used for monitoring X-ray beams, such as: ionization chamber, photodiode, phototransistor, among others. Recently nano-structured films made of various types of metal oxide materials have been used for various technological applications. Accordingly, the purpose of this paper is to present a sort of device based on a nano-structured zinc oxide (ZnO) to operate as a diagnostic X-ray sensor. By depositing a thin film on the glass substrate some ZnO semiconductor samples were built by sputtering techniques and then mounted in a BNC type connector to perform the electrical characterization. To test the device, we choose a standard X-Ray beam, the RQR9 radiation quality, which is normally used as the tool and condition for calibrating diagnostic X-Ray instruments in the energy range of computed tomography, in accordance with the stated requirements of IEC 61267. A 6430 sub-femto-ammeter, Keithley, was used as electrometer to perform the output readings and simultaneously bias the ZnO sensor. Analysis of the angular dependence and the dose rate were performed to evaluate how the device responds under the RQR9 radiation spectra. Although the results have shown that the ZnO film presents a certain angular dependence, if an angle of incidence of photons is selected, the device displays reproducibility as X-ray sensor and has the feature of radiation hardness unlike other types of semiconductor electronic devices typically used as an X-ray detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Target Multiwire for the Fermilab Booster Neutrino Beamline

The Booster Neutrino Beamline experiment re-quested a new secondary electron emission multiwire profile monitor installation. The device had to be durable in high radiation conditions and mounted within a large 10-foot airtight steel fixture for installation near the beam target. Previous iterations of multiwire suffered radiation damage to both the connectors and wires. To ensure accurate horizontal and vertical beam profile measurements, an updated design was pro-posed, designed, and constructed. The new BNB multiwire utilizes 3 mil diameter gold-plated tungsten sense wires soldered to vertical and horizontal Alumi-na-96 ceramic planes, 50 wires per plane. Radiation hard Kapton insulated 30-gauge wires carry the output signals. Profiles are readout through charge integrator scanner electronics. This paper will detail the design and functionality of the BNB target multiwire and present relevant beam profile data.

43 PARTICLE ACCELERATORS↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CAPTAN+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Capillary interconnect device

A manifold for connecting external capillaries to the inlet and/or outlet ports of a microfluidic device for high pressure applications is provided. The fluid connector for coupling at least one fluid conduit to a corresponding port of a substrate that includes: (i) a manifold comprising one or more channels extending therethrough wherein each channel is at least partially threaded, (ii) one or more threaded ferrules each defining a bore extending therethrough with each ferrule supporting a fluid conduit wherein each ferrule is threaded into a channel of the manifold, (iii) a substrate having one or more ports on its upper surface wherein the substrate is positioned below the manifold so that the one or more ports is aligned with the one or more channels of the manifold, and (iv) means for applying an axial compressive force to the substrate to couple the one or more ports of the substrate to a corresponding proximal end of a fluid conduit.

Renzi, Ronald F↗

Methods and systems for rapid prototyping of high density circuits

A preferred embodiment provides, for example, a system and method of integrating fluid media dispensing technology such as direct-write (DW) technologies with rapid prototyping (RP) technologies such as stereolithography (SL) to provide increased micro-fabrication and micro-stereolithography. A preferred embodiment of the present invention also provides, for example, a system and method for Rapid Prototyping High Density Circuit (RPHDC) manufacturing of solderless connectors and pilot devices with terminal geometries that are compatible with DW mechanisms and reduce contact resistance where the electrical system is encapsulated within structural members and manual electrical connections are eliminated in favor of automated DW traces. A preferred embodiment further provides, for example, a method of rapid prototyping comprising: fabricating a part layer using stereolithography and depositing thermally curable media onto the part layer using a fluid dispensing apparatus.

42 ENGINEERING↗

Material morphology and electrical resistivity differences in EPDM rubbers.

Electrical resistance anomalies noted in EPDM gaskets have been attributed to zinc-enriched surface sublayers, about 10-{micro}m thick, in the sulfur cured rubber material. Gasket over-compression provided the necessary connector pin contact and was also found to cause surprising morphological changes on the gasket surfaces. These included distributions of zinc oxide whiskers in high pressure gasket areas and cone-shaped features rich in zinc, oxygen, and sulfur primarily in low pressure protruding gasket areas. Such whiskers and cones were only found on the pin side of the gaskets in contact with a molded plastic surface and not on the back side in contact with an aluminum surface. The mechanisms by which such features are formed have not yet been defined.

42 ENGINEERING↗

Magnetic coupling device

A quick connect/disconnect coupling apparatus is provided in which a base member is engaged by a locking housing through a series of interengagement pins. The pins maintain the shaft in a locked position. Upon exposure to an appropriately positioned magnetic field, pins are removed a sufficient distance such that the shaft may be withdrawn from the locking housing. The ability to lock and unlock the connector assembly requires no additional tools or parts apart from a magnetic key.

42 ENGINEERING↗

Multifunctional Epidermal Electronics Printed Directly onto the Skin

Materials and designs are presented for electronics and sensors that can be conformally and robustly integrated onto the surface of the skin. A multifunctional device of this type can record various physiological signals relevant to health and wellness. Furthermore, this class of technology offers capabilities in biocompatible, non-invasive measurement that lie beyond those available with conventional, point-contact electrode interfaces to the skin.

36 MATERIALS SCIENCE↗

Endovascular Embolization of Bronchial Artery Originating from the Upper Portion of Aortic Arch in Patients with Massive Hemoptysis

Purpose: Our experience with endovascular embolization (EVE) of the bronchial artery (BA) originating from the upper portion of the aortic arch (AA) in six patients is described. Methods: Altogether, 818 patients with hemoptysis underwent multidetector row computed tomography angiography (MDCTA) before EVE or AA angiography during EVE. Aberrant BAs originating from the upper portion of the AA were the source of massive hemoptysis in six patients (0.73 %). MDCT angiograms and/or Digital subtraction angiograms were retrospectively reviewed. Selective catheterization and embolization were performed. Results: The ostia of the BAs were located on the superior surface of the AA between the brachiocephalic trunk and left common carotid artery in three patients, the junction of the aorta and medial surface of the left subclavian artery in two, and the posterior wall of the upper portion of the AA in one. The six BAs comprised two common trunks, three single right sides, and one single left side. The targeted vessels were successfully catheterized and embolized by a coaxial microcatheter system using polyvinyl alcohol particles. Other pathologic BAs and nonbronchial systemic arteries also were embolized. Bleeding was immediately controlled in all patients with no recurrence of hemoptysis. No procedure-related complications occurred. Conclusions: Application of EVE of anomalous origin of BAs in patients with hemoptysis is important, as demonstrated in the six reported patients. MDCTA before EVE or AA angiography during EVE is critical to avoid missing a rare aberrant BA originating from the upper portion of the AA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolisation for Symptomatic Adenomyosis with Polyzene F-Coated Hydrogel Microspheres: Three-Year Clinical Follow-Up Using UFS–QoL Questionnaire

PurposeThis study was designed to assess midterm outcome of uterine artery embolisation (UAE) for women with therapy-resistant adenomyosis using polyzene F-coated hydrogel microspheres.MethodsBetween September 2006 and January 2010, 29 consecutive women with adenomyosis (15 in combination with fibroids) were treated with UAE using polyzene F-coated hydrogel microspheres. Junction zone thickness was assessed with MRI at baseline and 3 months. Women filled out the uterine fibroid symptom and quality of life questionnaire at baseline, 3 months and after a mean clinical follow-up of 37 months (median 35, range 29–64 months).ResultsAt baseline, symptom severity score of 29 women was mean 67 (median 72, range 23–100). At 3 months, this score decreased to mean 22 (median 15, range 0–66) and mean 15 (median 17, range 0–34) at final follow-up. At final follow-up of mean 37 months (median 35, range 29–64 months), 22 of 29 (76 %) patients were asymptomatic. Of these 22 women, 3 underwent a second UAE at 6, 7, and 14 months. The remaining seven patients clinically improved but still had symptoms; one underwent a hysterectomy. There was no difference in outcome between women with pure adenomyosis and women with additional fibroids. The junction zone of 4 women with additional therapy was significantly thicker compared with the remaining 25 patients.ConclusionsIn women with therapy resistant adenomyosis, UAE using polyzene F-coated hydrogel microspheres resulted in 3 years preservation of the uterus in 28 of 29 (97 %) with good clinical outcome in the vast majority of patients. Initial thickness of the junction zone is related to additional therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗