Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

Technical Note: EGSnrc-based dosimetric study of the BEBIG {sup 60}Co HDR brachytherapy sources

Purpose: The purpose of this work is to calculate two-dimensional (2D) dose rate distributions around the BEBIG (Eckert and Ziegler, BEBIG GmbH, Germany) models GK60M21 (old) and Co0.A86 (new) {sup 60}Co high dose rate brachytherapy sources in an unbounded liquid water phantom. The study includes calculation of absorbed dose to water-kerma ratio D/K around the BEBIG sources and a {sup 60}Co point source in water. A comparison is made with previously published data. Methods: The EGSnrcMP Monte Carlo code system is used to calculate the absorbed dose and water-kerma in water and air-kerma strength in vacuum. EGSnrcMP-based user codes such as EDKnrc, FLURZnrc, and DOSRZnrc are employed in the work. Results: The value of D/K reaches a maximum of 1.040{+-}0.002 for the {sup 60}Co point source (constant between 3.6 and 4.5 mm from the source) and 1.076{+-}0.002 for the BEBIG sources (constant between 2.6 and 3.2 mm along the transverse axis of the sources). Dose rate data for the new and old sources are comparable to published data for radial distances r>0.5 cm. Differences up to 9% are observed at points close to the source (r=0.25 cm). In addition for the new source, compared to previously published data, dose rate data are higher by 14% along the longitudinal axis where the source cable is connected. Dose rate differences on the longitudinal axis ({theta}=180 deg.) of this source are explained by varying the length of the simulated source cable. Conclusions: The 2D rectangular data set calculated in the present work could be considered for quality control on radiotherapy treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Report: Multi-Instrument Comparison of AAF Condensation Particle Counters

Condensation particle counters (CPCs), also known as condensation nucleus counters (CNCs) are sophisticated instruments designed to measure the concentration of aerosol particles in the atmosphere. These devices are pivotal in environmental monitoring, industrial applications, and scientific research, particularly in atmospheric studies. CPCs are vital for understanding the role of aerosols in climate systems. Aerosols influence cloud formation, radiative forcing, and atmospheric chemistry. By providing accurate measurements of particle concentrations and distributions, CPCs contribute to models that predict atmospheric impact and weather patterns (Mei et al. 2021). CPCs operate by enlarging submicron particles, including those as small as a few nanometers, to sizes detectable by optical methods. This report delves into the mechanisms, importance, and contributions of CPCs to atmospheric research at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), highlighting their role in advancing air quality assessment, pollution control, and atmospheric studies.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric constituent measurements using commercial 747 airliners

NASA is implementing a global atmospheric monitoring program to measure the temporal and spatial distribution of particulate and gaseous constituents related to aircraft engine emissions in the upper troposphere and lower stratosphere (6 to 12 km). Several 747 aircraft operated by different airlines flying routes selected for maximum world coverage will be instrumented. The initial design of the system (location of equipment, aircraft interfaces, etc.) was conceptually defined in feasibility studies conducted by several airlines and an airframe company. An instrumentation system is now being assembled and tested and is scheduled for operation in airline service in late 1974. An ambient air sampling system was developed to provide undisturbed outside air to the instruments in the pressurized aircraft cabin.

Perkins, P. J.↗

Ozone variations observed during the International Ozone Rocket Sonde Intercomparison

The International Ozone Rocket Sonde Intercomparison (IORI) conducted at Wallops Island during October 1979 provided a unique opportunity to observe ozone variations in great detail from several observing systems. The measurement period lasted 15 days during which time ozone observations were taken by ground-based, balloon, rocket, and satellite instruments. These data provided a unique opportunity for diagnosing regional stratospheric variability over a 2 week period. Examination of NMC analyses indicated that during this period the stratospheric polar vortex moved southeastward bringing air form high latitudes to Wallops Island above 10 mb. A concurrent change was observed in the upper stratosphere ozone fields observed by Nimbus-7 SBUV and in the ozone vertical distribution measured by the rocket soundings. In this study the satellite and rocket measurements are compared. The agreement is good, certainly within the errors of the measurements.

Hilsenrath, E.↗

A wall interference assessment/correction system

A Wall Signature method originally developed by Hackett was selected to be adapted for the Ames 12-ft Wind Tunnel Wall Interference Assessment/Correction (WIAC) System in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interference at the model location. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered, and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method - Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. The following two additional tasks are included in the supplement No. 1 to the basic Grant. On-line wall interference calculation: The developed wall signature method (modified Hackett's method) for Ames 12-ft Tunnel will be the pre-computed coefficients which facilitate the on-line calculation of wall interference; and support system effects estimation: The effects on the wall pressure measurements due to the presence of the model support systems will be evaluated.

Lo, Ching F.↗

Global Lightning Activity

Our knowledge of the global distribution of lightning has improved dramatically since the advent of spacebased lightning observations. Of major importance was the 1995 launch of the Optical Transient Detector (OTD), followed in 1997 by the launch of the Lightning Imaging Sensor (LIS). Together, these instruments have generated a continuous eight-year record of global lightning activity. These lightning observations have provided a new global perspective on total lightning activity. For the first time, total lightning activity (cloud-to-ground and intra-cloud) has been observed over large regions with high detection efficiency and accurate geographic location. This has produced new insights into lightning distributions, times of occurrence and variability. It has produced a revised global flash rate estimate (44 flashes per second) and has lead to a new realization of the significance of total lightning activity in severe weather. Accurate flash rate estimates are now available over large areas of the earth (+/- 72 deg. latitude). Ocean-land contrasts as a function of season are clearly reveled, as are orographic effects and seasonal and interannual variability. The space-based observations indicate that air mass thunderstorms, not large storm system dominate global activity. The ability of LIS and OTD to detect total lightning has lead to improved insight into the correlation between lightning and storm development. The relationship between updraft development and lightning activity is now well established and presents an opportunity for providing a new mechanism for remotely monitoring storm development. In this concept, lightning would serve as a surrogate for updraft velocity. It is anticipated that this capability could lead to significantly improved severe weather warning times and reduced false warning rates. This talk will summarize our space-based lightning measurements, will discuss how lightning observations can be used to monitor severe weather, and present a concept for continuous geostationary-based lightning observations.

Christian, Hugh J.↗

Global Mobile Satellite Service Interference Analysis for the AeroMACS

The AeroMACS (Aeronautical Mobile Airport Communications System), which is based on the IEEE 802.16-2009 mobile wireless standard, is envisioned as the wireless network which will cover all areas of airport surfaces for next generation air transportation. It is expected to be implemented in the 5091-5150 MHz frequency band which is also occupied by mobile satellite service uplinks. Thus the AeroMACS must be designed to avoid interference with this incumbent service. Simulations using Visualyse software were performed utilizing a global database of 6207 airports. Variations in base station and subscriber antenna distribution and gain pattern were examined. Based on these simulations, recommendations for global airport base station and subscriber antenna power transmission limitations are provided.

Wilson, Jeffrey D.↗

Global Mobile Satellite Service Interference Analysis for the AeroMACS

The AeroMACS (Aeronautical Mobile Airport Communications System), which is based on the IEEE 802.16-2009 mobile wireless standard, is envisioned as the wireless network which will cover all areas of airport surfaces for next generation air transportation. It is expected to be implemented in the 5091-5150 MHz frequency band which is also occupied by mobile satellite service uplinks. Thus the AeroMACS must be designed to avoid interference with this incumbent service. Simulations using Visualyse software were performed utilizing a global database of 6207 airports. Variations in base station and subscriber antenna distribution and gain pattern were examined. Based on these simulations, recommendations for global airport base station and subscriber antenna power transmission limitations are provided.

Wilson, Jeffrey D.↗

Refined Analysis of CO2 Emissions in Urban Air Mobility Networks

In this study, we examine the environmental impact of Urban Air Mobility (UAM) operations as measured via carbon dioxide (CO2) emissions by leveraging a computational model from previous studies that has been refined and expanded. Several scenarios are examined in which total transportation emissions for a representative day in a metro area are distributed differently among vehicle types and transportation modes. Specifically, we investigate the use of electric air vehicles in a UAM network; the increasing presence of electric ground vehicles for ground transportation; the impacts from implementing ridesharing in the UAM mode; and the effects of varying the electricity grid emissions. Results for a case study in the Chicago, IL metro area indicate that incorporating electric ground vehicles and UAM ridesharing can both lead to reduced CO2 emissions. These preliminary results indicate that carbon emissions from a UAM system leveraging ridesharing and all-electric aircraft may not be a practical operational limit on UAM, though further improvements to the modeling are warranted.

advanced air mobility↗

Refined Analysis of CO2 Emissions in Urban Air Mobility Networks

In this study, we examine the environmental impact of Urban Air Mobility (UAM) operations as measured via carbon dioxide (CO2) emissions by leveraging a computational model from previous studies that has been refined and expanded. Several scenarios are examined in which total transportation emissions for a representative day in a metro area are distributed differently among vehicle types and transportation modes. Specifically, we investigate the use of electric air vehicles in a UAM network; the increasing presence of electric ground vehicles for ground transportation; the impacts from implementing ridesharing in the UAM mode; and the effects of varying the electricity grid emissions. Results for a case study in the Chicago, IL metro area indicate that incorporating electric ground vehicles and UAM ridesharing can both lead to reduced CO2 emissions. These preliminary results indicate that carbon emissions from a UAM system leveraging ridesharing and all-electric aircraft may not be a practical operational limit on UAM, though further improvements to the modeling are warranted.

advanced air mobility↗

Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

dehumidification↗

Building America Case Study: Columbia County Habitat for Humanity Passive Townhomes, Hudson, New York

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18 percent of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proton therapy dose distribution comparison between Monte Carlo and a treatment planning system for pediatric patients with ependymoma

Purpose: Compare dose distributions for pediatric patients with ependymoma calculated using a Monte Carlo (MC) system and a clinical treatment planning system (TPS). Methods: Plans from ten pediatric patients with ependymoma treated using double scatter proton therapy were exported from the TPS and calculated in our MC system. A field by field comparison of the distal edge (80% and 20%), distal fall off (80% to 20%), field width (50% to 50%), and penumbra (80% to 20%) were examined. In addition, the target dose for the full plan was compared. Results: For the 32 fields from the 10 patients, the average differences of distal edge at 80% and 20% on central axis between MC and TPS are -1.9 {+-} 1.7 mm (p < 0.001) and -0.6 {+-} 2.3 mm (p= 0.13), respectively. Excluding the fields that ranged out in bone or an air cavity, the 80% difference was -0.9 {+-} 1.7 mm (p= 0.09). The negative value indicates that MC was on average shallower than TPS. The average difference of the 63 field widths of the 10 patients is -0.7 {+-} 1.0 mm (p < 0.001), negative indicating on average the MC had a smaller field width. On average, the difference in the penumbra was 2.3 {+-} 2.1 mm (p < 0.001). The average of the mean clinical target volume dose differences is -1.8% (p= 0.001), negative indicating a lower dose for MC. Conclusions: Overall, the MC system and TPS gave similar results for field width, the 20% distal edge, and the target coverage. For the 80% distal edge and lateral penumbra, there was slight disagreement; however, the difference was less than 2 mm and occurred primarily in highly heterogeneous areas. These differences highlight that the TPS dose calculation cannot be automatically regarded as correct.

60 APPLIED LIFE SCIENCES↗

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings

This guideline provides building owners, professionals involved in multifamily audits, and contractors insights for improving the balance and tuning of steam systems. It provides readers an overview of one-pipe steam heating systems, guidelines for evaluating steam systems, typical costs and savings, and guidelines for ensuring quality installations. It also directs readers to additional resources for details not included here. Measures for balancing a distribution system that are covered include replacing main line vents and upgrading radiator vents. Also included is a discussion on upgrading boiler controls and the importance of tuning the settings on new or existing boiler controls. The guideline focuses on one-pipe steam systems, though many of the assessment methods can be generalized to two-pipe steam systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2017 Standard Scenarios Report: A U.S. Electricity Sector Outlook

This report summarizes the results of 26 forward-looking “standard scenarios” of the U.S. power sector simulated by the National Renewable Energy Laboratory (NREL) using the Regional Energy Deployment System (ReEDS) and Distributed Generation (dGen) capacity expansion models. The annual Standard Scenarios, which are now in their third year, have been designed to capture a range of possible power system futures considering a variety of factors that impact power sector evolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of design changes and operating conditions on combustion and operational performance of a 28-inch diameter Ram-jet engine / T. B. Shillito and Shigeo Nakanishi

The results of an altitude test-chamber investigation of the effects of a number of design changes and operating conditions on altitude peformance of a 28-inch diameter ram jet engine are presented. Most of the investigation was for a simulated flight Mach number of 2.0 above the tropopause. Fuel-air distribution, gutter width, the presence of a pilot flame, cimbustion-chamber-inlet temperature, and exhaust-nozzle throat area were found to have significant effects on limits of combustion. Combustion efficiency increased with increasing combustion-chamber-inlet temperature and was adversely affected by an increase in the exhaust-nozzld area. Similiar lean limits of combustion were obtained for both Diesel fuel and normal heptane, but combustion efficiences obtained with Diesel fuel were lower than those obtained with normal heptane.

NOZZLES, EXHAUST - ENGINES, JET↗