Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Pd-promoted reduction and restructuring of an In 2 O 3 -based catalyst for CO 2 hydrogenation at room temperature

An unconventional reaction mechanism in an In 2 O 3 /Pd(1 1 1) inverse model catalyst for the CO 2 hydrogenation reaction has been uncovered: In 2 O 3 is partially reduced at room temperature in a reaction atmosphere as a result of its direct contact with Pd(1 1 1), which is an efficient H 2 splitter. The reduction induces changes in surface free energy, leading to a dynamical restructuring at the In 2 O 3 /Pd(1 1 1) interface via formation of InO x and outward diffusion of Pd, as revealed by ambient pressure X-ray photoelectron spectroscopy, X-ray absorption spectroscopy and density functional theory simulations. This dynamical restructuring eventually promotes the growth of 2D InPd y O x nanodomains as the catalytically active phase and the exclusive formation of methanol upon hydrogenation of CO 2 at room temperature. A comparable high selectivity toward CH 3 OH was found in more realistic bulk catalytic systems (2 wt% Pd/In 2 O 3 catalyst and commercial CZA catalyst). Scanning tunneling microscopy under ultrahigh vacuum and ambient pressure reaction atmospheres further reveals the structural dynamics at the InO x /Pd(1 1 1) interface, where we follow in situ the evolution of the InO x particles on Pd(1 1 1) and the mobility of the InPd y O x nanodomains in a CO 2 + H 2 environment. The present findings of the formation of a mixed oxide phase in a dynamically restructuring metal/reducible-oxide interface indicate further implications for other heterogeneous catalytic systems beyond the present CO 2 hydrogenation example and highlight the importance of in situ investigations.

36 MATERIALS SCIENCE↗

Analysis of the Shattered Pellet Injection Fragment Plumes Generated by Machine Specific Shatter Tube Designs

Shattered pellet injector systems have been installed on DIII-D, JET, and KSTAR and used to experimentally determine the effectiveness of the shattered pellet injection (SPI) process in mitigating the deleterious effects of a tokamak plasma disruption. Pellets are fired, and before entering the plasma, strike a bent tube known as a shatter tube causing the pellet to shatter. The process of pellet fragmentation is a chaotic process that can be described in terms of fragment size distribution through a statistical model that incorporates the effects of the pellet material and impact characteristics. In addition to the fragment size distribution, the shatter plume has other characteristics of interest, such as a fragment velocity distribution and temporal mass evolution. The fragment velocity distribution is important because it is needed to accurately model the spread and location of the ablation and the deposition of impurities in the plasma over time. The temporal mass evolution is necessary to determine the time-resolved delivery of mass to the plasma.Due to installation constraints, the shatter tube currently installed on JET has a unique geometry with a modest S-bend followed by a 20-deg bend at the end of the tube. The DIII-D and KSTAR shatter tube design is a simple tube bent through an angle of 20 deg followed by a straight section. The resulting shatter sprays from the JET shatter tube and a 20-deg miter bend shatter tube were experimentally characterized for various pellet materials and speeds. Laboratory testing of these shatter tubes allows for the use of fast cameras to capture the fragment spray traveling through a large vacuum chamber. These high-speed videos of the shatter plumes allow the fragment size distribution, temporal mass evolution, and velocity distribution of the fragments within the plume to be determined. Overall, this paper presents a comparison of the unique geometry of the JET shatter tube to the miter bend geometries used for shattering and some insight into the variables that may be adjusted to produce the optimal shatter spray. The impact of entrained propellant gas on the resulting shatter spray was examined during testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Including the vacuum energy in stellarator coil design

Being three-dimensional, stellarators have the advantage that plasma currents are not essential for creating rotational-transform; however, the external current-carrying coils in stellarators can have strong geometrical shaping, which can complicate the construction. Reducing the inter-coil electromagnetic forces acting on strongly shaped 3D coils and the stress on the support structure while preserving the favorable properties of the magnetic field is a design challenge. In this work, we recognize that the inter-coil forces are the gradient of the vacuum magnetic energy. We introduce an objective functional built on the usual quadratic flux on a prescribed target surface together with a weighed penalty on the vacuum energy. The Euler–Lagrange equation for stationary states is derived, and numerical illustrations are computed using a modern stellarator optimization framework. A study of the effect of the energy functional on the inter-coil forces is conducted and the energy is shown to be a promising quantity in producing coils with low forces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Early Results from Solar Dynamic Space Power System Testing

A government/industry team designed, built and tested a 2-kWe solar dynamic space power system in a large thermal vacuum facility with a simulated Sun at the NASA Lewis Research Center. The Lewis facility provides an accurate simulation of temperatures, high vacuum and solar flux as encountered in low-Earth orbit. The solar dynamic system includes a Brayton power conversion unit integrated with a solar receiver which is designed to store energy for continuous power operation during the eclipse phase of the orbit. This paper reviews the goals and status of the Solar Dynamic Ground Test Demonstration project and describes the initial testing, including both operational and performance data. System testing to date has accumulated over 365 hours of power operation (ranging from 400 watts to 2.0-W(sub e)), including 187 simulated orbits, 16 ambient starts and 2 hot restarts. Data are shown for an orbital startup, transient and steady-state orbital operation and shutdown. System testing with varying insolation levels and operating speeds is discussed. The solar dynamic ground test demonstration is providing the experience and confidence toward a successful flight demonstration of the solar dynamic technologies on the Space Station Mir in 1997.

Shaltens, Richard K.↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuity of reaction kinetics across the pressure and materials gaps in CO oxidation on FeO–Pt interfaces

Translating atomic-scale insights from surface science studies of model catalysts to practical powder catalysts remains a persistent challenge in heterogeneous catalysis. Here, in this study, we demonstrate mechanistic continuity across the pressure and materials gaps during CO oxidation at the FeO-Pt interface using in situ microscopy, spectroscopy and computational modelling. Under reaction conditions, coordinatively unsaturated Fe (Fe cus ) sites at the interface enable selective O 2 activation on CO-saturated surfaces, circumventing the CO-poisoning limitation of platinum-group metals. We identify parallel reaction pathways involving the *O 2 -*CO intermediate. Remarkably, activation energies remain consistent at 12-15 kJ mol −1 (0.12-0.16 eV) from ultrahigh vacuum to atmospheric pressures and from FeO/Pt(111) model catalysts to FeO/Pt powder catalysts, validating mechanistic insights derived from surface science studies. Our findings show an example of bridging the long-standing divide between model and practical catalyst systems, establishing an effective approach to capture catalytic behaviours under operational conditions and advancing mechanism-driven catalyst design.

03 NATURAL GAS↗

Pressure-driven stochastization of flux surfaces in stellarator equilibria: a review of the experimental observations and their analysis

Stellarator vacuum fields are designed to have a dense set of nested flux surfaces, with only small islands and stochastic regions in the interior of the confinement region. As the plasma pressure is increased, pressure driven currents appear, and they can significantly modify the vacuum field. The question arises whether pressure driven currents can cause significant flux surface breakage. Both the Wendelstein 7-AS and large helical device stellarators had dedicated experimental campaigns to study the β limit in those devices. In this paper, we review the evidence that the flux surfaces in a significant fraction of the plasma volume were stochastized by the pressure-driven currents in the highest β experiments. That phenomenon appears to have been the dominant source of pressure-driven flux surface loss in these experiments.

stellarator equilibrium↗

Evaluation of Thermal Control Coatings and Polymeric Materials Exposed to Ground Simulated Atomic Oxygen and Vacuum Ultraviolet Radiation

Numerous thermal control and polymeric samples with potential International Space Station applications were evaluated for atomic oxygen and vacuum ultraviolet radiation effects in the Princeton Plasma Physics Laboratory 5 eV Neutral Atomic Oxygen Facility and in the MSFC Atomic Oxygen Drift Tube System. Included in this study were samples of various anodized aluminum samples, ceramic paints, polymeric materials, and beta cloth, a Teflon-impregnated fiberglass cloth. Aluminum anodizations tested were black duranodic, chromic acid anodize, and sulfuric acid anodize. Paint samples consisted of an inorganic glassy black paint and Z-93 white paint made with the original PS7 binder and the new K2130 binder. Polymeric samples evaluated included bulk Halar, bulk PEEK, and silverized FEP Teflon. Aluminized and nonaluminized Chemfab 250 beta cloth were also exposed. Samples were evaluated for changes in mass, thickness, solar absorptance, and infrared emittance. In addition to material effects, an investigation was made comparing diffuse reflectance/solar absorptance measurements made using a Beckman DK2 spectroreflectometer and like measurements made using an AZ Technology-developed laboratory portable spectroreflectometer.

Kamenetzky, R. R.↗

Hollow Fiber Space Water Membrane Evaporator Flight Prototype Design and Testing

The spacesuit water membrane evaporator (SWME) is being developed to perform thermal control for advanced spacesuits and to take advantage of recent advances in micropore membrane technology. This results in a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. The current design was based on a previous design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape. This was developed into a full-scale prototype consisting of 14,300 tube bundled into 30 stacks, each of which is formed into a chevron shape and separated by spacers and organized into three sectors of 10 nested stacks. The new design replaced metal components with plastic ones, eliminated the spacers, and has a custom built flight like backpressure valve mounted on the side of the SWME housing to reduce backpressure when fully open. A number of tests were performed in order to improve the strength of the polyurethane header that holds the fibers in place while the system is pressurized. Vacuum chamber testing showed similar heat rejection as a function of inlet water temperature and water vapor backpressure was similar to the previous design. Other tests pushed the limits of tolerance to freezing and showed suitability to reject heat in a Mars pressure environment with and without a sweep gas. Tolerance to contamination by constituents expected to be found in potable water produced by distillation processes was tested in a conventional way by allowing constituents to accumulate in the coolant as evaporation occurs. For this purpose, the SWME cartridge has endured an equivalent of 30 EVAs exposure and demonstrated acceptable performance decline.

Bue, Grant C.↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synthesis, crystal structure, and magnetic properties of CoMoFeAl and related compounds

We have carried out joint theoretical and experimental investigations of three Heusler compounds CoMoFeAl, CoMo 0.5 Fe 1.5 Al, and Co 1.5 Mo 0.5 FeAl. Our first-principle calculations show that all three compounds show either ferro- or ferrimagnetic order with CoMoFeAl and CoMo 0.5 Fe 1.5 Al exhibiting high spin polarization of almost 80%. The investigated samples were prepared using arc melting and high vacuum annealing. All the samples show cubic crystal structure with disorder. The parent compound CoMoFeAl shows a small saturation magnetization of 12 emu/g, and a Curie temperature of 440 K. The other two compounds, namely, Co 1.5 Mo 0.5 FeAl and CoMo 0.5 Fe 1.5 Al, show much higher saturation magnetizations of 62 emu/g and 59 emu/g, and substantially higher Curie temperatures of 950 K and 780 K, respectively.

36 MATERIALS SCIENCE↗

Thermal Management and Thermal Protection Systems

During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun's rays directly impinging on the system. Heating rate of the lamps were calculated by knowing fraction of emitted energy in a wavelength interval and the filament temperature. This version of the model can be used to predict performance of the system under vacuum with extreme cold or hot conditions. Initial testing of the PTMS showed promise, and the thermal math model predicts even better performance in thermal vacuum testing. ii) Thermal Protection Systems (TPS) are required for vehicles which enter earth's atmosphere to protect from aerodynamic heating caused by the friction between the vehicle and atmospheric gases. Orion's heat shield design has two aspects which needed to be analyzed thermally: i) a small excess of adhesive used to bond the outer AVCOAT layer to the inner composite structure tends to seep from under the AVCOAT and form a small bead in between two bricks of AVCOAT, ii) a silicone rubber with different thermophysical properties than AVCOAT fills the gap between two bricks of AVCOAT. I created a thermal model using TD to determine temperature differences that are caused by these two features. To prevent false results, all TD models must be verified against something known. In this case, the TD model was correlated to CHAR, an ablation modelling software used to analyze TPS. Analyzing a node far from the concerning features, we saw that the TD model data match CHAR data, verifying the TD model. Next, the temperature of the silicone rubber as well as the bead of adhesive were analyzed to determine if they exceeded allowable temperatures. It was determined that these two features do not have a significant effect on the max temperature of the heat shield. This model can be modified to check temperatures at various locations of the heat shield where the composite thickness varies.

Hasnain, Aqib↗

Structure Sensitivity and Catalyst Restructuring for CO2 Electro-reduction on Copper

Abstract Cu is the most promising metal catalyst for CO 2 electroreduction (CO 2 RR) to multi-carbon products, yet the structure sensitivity of the reaction and the stability versus restructuring of the catalyst surface under reaction conditions remain controversial. Here, atomic scale simulations of surface energies and reaction pathway kinetics supported by experimental evidence unveil that CO 2 RR does not take place on perfect planar Cu(111) and Cu(100) surfaces but rather on steps or kinks. These planar surfaces tend to restructure in reaction conditions to the active stepped surfaces, with the strong binding of CO on defective sites acting as a thermodynamic driving force. Notably, we identify that the square motifs adjacent to defects, not the defects themselves, as the active sites for CO 2 RR via synergistic effect. We evaluate these mechanisms against experiments of CO 2 RR on ultra-high vacuum-prepared ultraclean Cu surfaces, uncovering the crucial role of step-edge orientation in steering selectivity. Overall, our study refines the structural sensitivity of CO 2 RR on Cu at the atomic level, highlights the self-activation mechanism and elucidates the origin of in situ restructuring of Cu surfaces during the reaction.

Science & Technology - Other Topics↗

A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

Heverly, Matthew↗

Impact of annealing at 1000°C in flowing He with low O 2 concentration on the room temperature tensile properties of Mo alloys

NorthStar is developing an accelerator-based technology to produce the medical isotope Mo-99. A previous ORNL report (ORNL/SPR-2022/2490) studied the oxidation behavior of Mo in flowing He with low oxygen content at 800°C and 1000°C and it was shown that an O 2 concentration lower than ~5ppm (μ1/1) is required to achieve acceptable oxidation rates for wrought or powder metallurgy (PM) Mo. Oxidation may also impact the mechanical properties of Mo and this report summarizes tensile results at room temperature on wrought and PM Mo before and after exposure at 1000°C in flowing He with O 2 concentration varying from 1 to 15 ppm O 2 . It was found that oxidation at 1000°C results in a significant decrease of Mo strength and ductility with brittle intergranular fracture surfaces, likely due to the segregation of oxygen at grain boundaries. For the PM Mo material, the decrease in strength and ductility was also observed after annealing in vacuum at 1000°C, indicating that the diffusion of the oxygen trapped in the material pores to grain boundaries after 20-100h at 1000°C is sufficient to embrittle the material. Finally, initial results on actual aMo and high-density disks provided by NorthStar revealed the lack of ductility of the materials due to the specific disk microstructure.

36 MATERIALS SCIENCE↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of size-selected Pt cluster catalysts on prototypical oxide supports

The current quest for new pathways into sustainable, efficient and durable energy conversion technologies makes the used for a fundamental understanding of the atomic-scale phenomena underlying catalytic processes ever more pressing. In this context, characterizing catalyst particles in situ provides valuable information about the evolution of their composition, structure, oxidation state and charge state during an ongoing process. To disentangle the influence of individual parameters – temperature, pressure, gas composition, cluster size, as well as support acidity, redox state and defect density – it is crucial to control them precisely and separately in experiments. At the example of size-selected Pt n clusters – i.e. sub-nm particles defined to the exact number of atoms – on flat oxide supports, we follow their rich evolution phenomena via (synchrotron-based) X-ray photoelectron spectroscopy (XPS) and scanning tunnelling microscopy (STM) during temperature ramps and in various gas environments. Here, we present our experience with these highly defined, yet complicated-to-create samples in ultra-high vacuum (UHV) and at mbar pressures. We discuss their stability during transport to synchrotrons and under reaction conditions on three prototypical oxide supports and show the various phenomena that can be disentangled. Ptn clusters on the non-reducible silicon dioxide, SiO 2 , remain size-selected and show remarkable stability. Doping strongly influences the size-dependent binding energy shifts and changes the Pt response to oxidative and reaction conditions, which we attribute to different cluster geometries: p-type doping leads to wetting, enhanced sinter resistance and a diminished response to oxidative environments, compared to clusters on n-type doped samples. We compare the system with our previous findings of a similar change in dimensionality for Pt 20 clusters on the reducible ceria, CeO 2 (111), support, induced by modulation of its O vacancy density. The Pt n /CeO 2 system is particularly interesting for strategies to stabilize and redisperse Pt clusters dynamically. Finally, we study the evolution of Pt n clusters on another reducible oxide support, magnetite, Fe 3 O 4 (001), in 0.1 mbar alternating redox conditions at RT and elevated temperature. In analogy to findings previously reported for Pt/TiO 2 (110), the clusters either become encapsulated by a thin oxide film via strong metal–support interaction (SMSI) or deeply buried in the magnetite. Overall, our approach of following the evolution of size-selected clusters on oxide supports leads to fundamental atomic-scale insights on nano-scale catalyst materials, on our path to sustainable, dynamic and self-repairing catalysts.

Falling, Lorenz J. [Technical Univ. of Munich (Ger↗

Research and test facilities for development of technologies and experiments with commercial applications

One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

Source record↗