Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Treatment in Intermediate-Risk Prostate Cancer: Secondary Analysis of a Randomized Phase 3 Trial

To identify patients with intermediate-risk prostate cancer (IRPC) benefiting from de-escalation of androgen deprivation therapy (ADT) and/or dose escalated radiation therapy (DERT), we performed a secondary analysis of a phase 3 trial by measuring biochemical failure (BF), distant metastases, prostate cancer–specific mortality, overall survival (OS), and distant metastases-free survival (DMFS) rates according to prognostic intermediate risk factors (IRF).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joint Optimization of Photon–Carbon Ion Treatments for Glioblastoma

Carbon ions are radiobiologically more effective than photons and are beneficial for treating radioresistant gross tumor volumes (GTV). However, owing to a reduced fractionation effect, they may be disadvantageous for treating infiltrative tumors, in which healthy tissue inside the clinical target volume (CTV) must be protected through fractionation. This work addresses the question: What is the ideal combined photon–carbon ion fluence distribution for treating infiltrative tumors given a specific fraction allocation between photons and carbon ions?.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments

Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Therapy in Supradiaphragmatic Lymphoma: Predicting Treatment-Related Mortality to Help Optimize Patient Selection

In some patients with Hodgkin lymphoma (HL), proton beam therapy (PBT) may reduce the risk of radiation-related cardiovascular disease (CVD) and second cancers (SC) compared with photon radiation therapy (RT). Our aim was to identify patients who benefit the most from PBT in terms of predicted 30-year absolute mortality risks (AMR{sub 30}) from CVD and SC, taking into account individual background, chemotherapy, radiation, and smoking-related risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alkali-activated slag (AAS) and OPC-based composites containing crumb rubber aggregate: Physico-mechanical properties, durability and oxidation of rubber upon NaOH treatment

Value-added utilization of waste tires in cementitious materials has been studied for decades, whereas the synergy between rubber and alkali-activated cements deserves more investigations. To this end, we compared physico-mechanical and durability properties of alkali-activated slag (AAS) and OPC-based composites containing NaOH-pretreated/as-received crumb rubber (CR). It was found that the incorporation of CR had both positive and negative effects on specimens due to its special attributes. CR reduced electrical conductivity which was associated with the ion transport ability, since it worked as an electrical insulator and increased hydrophobicity of pore walls. The sulfate expansion decreased with CR content because the flow of sulfate ions was demobilized, and the flexibility of CR relieved the internal stress. CR also improved the freeze-thaw durability of composites if the total CR content was less than 30% in specimens. However, the low Young's modulus of CR impaired the compressive strength and failed to effectively control the total shrinkage upon drying. The composites with CR must avoid high temperature exposure which resulted in the pyrolysis of rubber. In addition, the NaOH pretreatment enhanced adhesion between CR and hydrated cement and improved overall performances of composites. The FTIR spectra confirmed the NaOH-induced accelerated oxidation of CR surface and the generation of polar functional groups including carbonyl and carboxyl groups, increasing the total surface energy of rubber. More importantly, the alkali-activation process for AAS could treat the CR aggregate in the meantime, which means the use of CR in alkali-activated cements does not require the pretreatment of CR before blending.

36 MATERIALS SCIENCE↗

Improved treatment of multi-material cells in thermal radiation transport codes

High-energy-density physics simulations with non-conformal meshes of materials require a multi-material (MM) closure that affects the thermal radiation transport (TRT). We propose a set of novel closures that work for an arbitrary number of materials, both grey and multigroup energy discretizations, and any angular discretization (such as Sn, IMC, or diffusion). For each spatial cell, our closures let each species (ion and electron) of each material have its own temperature, density, and internal energy, but use a single radiation distribution that interacts with all materials within the cell. Our closures maintain energy conservation, do not incur increased computational cost in the TRT solve itself, are compatible with single-material TRT solvers, and do not make any temperature-equilibrium assumptions. Here we test our closures on a wide range of increasingly realistic problems and find them to be robust.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗