Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

GPU-friendly surface model for Monte-Carlo detector simulations

The demands for Monte-Carlo simulation are drastically increasing with the Large Hadron Collider’s high-luminosity upgrade, and are expected to exceed the currently available compute resources. At the same time, modern high-performance computing has adopted powerful hardware accelerators, particularly GPUs. The AdePT and Celeritas projects aim to address the demanding computational needs by leveraging these heterogeneous computing architectures. While both have successfully ported realistic detector simulations to GPUs using the VecGeom library, the complexity of geometry modeling emerged as a bottleneck. Thread divergence and high register usage were degrading the GPU performance. Therefore, a new, GPU-friendly surface-based model has been introduced in the VecGeom library that decomposes the divergent code of the 3D primitive solids into simpler and more balanced surface algorithms. In this work, we present the latest developments, focusing on the additions required to efficiently model complex setups like the CMS Phase-2 geometry. This includes memory reduction techniques, and adding accelerating structures for faster traversal.

Diederichs, Severin [CERN]↗

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

Investigation of sCVD diamond detectors for low energy heavy-ion reactions

Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Technical Assistance for RingIR Aerosol Penetration Study with RingIR

Sandia provided technical assistance to RingIR to test and evaluate of the RingIR molecular detector. The detector can identify gas phase species using molecular fingerprinting and has potential application for SARS-CoV-2 detection in near real time. As part of the development process Sandia will utilize the biological aerosol test bed deployed at the Aerosol Complex to evaluate the penetration of MS2 bacteriophage aerosol through the RingIR system. The objective of this project is to provide experimentally derived measurements of the RingIR molecular detector penetration efficiency, including external exhaust filter for mitigation of exhaust aerosol and operation using MS2 bacteriophage as a biological surrogate to the SARS-CoV-2 virus.

59 BASIC BIOLOGICAL SCIENCES↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Evidence for the singly Cabibbo-suppressed decay Ω 0 c → Ξ¯π + and search for Ω 0 c → Ξ¯ K + and Ω¯K + decays at Belle

Using a data sample of 980 fb -1 collected with the Belle detector at the KEKB asymmetric-energy e + e - collider, we study for the first time the singly Cabibbo-suppressed decays Ω 0 c → Ξ¯π + and Ω¯K + and the doubly Cabibbo-suppressed decay Ω 0 c → Ξ¯ K + . Evidence for an Ω 0 c signal in the Ω 0 c → Ξ¯π + mode is reported with a significance of 4.5σ including systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for new hadronic decays of $h_c$ and observation of $h_c$ → $p\overline{p}η$

A search for the hadronic decays of the $h_c$ meson to the final states $p\overline{p}π^+π^-π^o$, $p\overline{p}η$, and $p\overline{p}π^o$ via the process $\psi$(3686) → $π^oh_c$ is performed using (4.48 ± 0.03) x 10 8 $\psi$(3686) events collected with the BESIII detector. The decay channel $h_c$ → $p\overline{p}η$ is observed for the first time with a significance greater than 5σ and a branching fraction of (6.41 ± 1.74 ± 0.53 ± 1.00) x 10 -4 , where the uncertainties are statistical, systematic, and that from the branching fraction of $\psi$(3686) → $π^oh_c$. Strong evidence for the decay $h_c$ → $p\overline{p}π^+π^-π^o$ is found with a significance of 4.9σ and a branching fraction of (3.84 ± 0.83 ± 0.69 ± 0.58) x 10 -3 . The significances include systematic uncertainties. No clear signal of the decay $h_c$ → $p\overline{p}π^o$ is found, and an upper limit of 6.59 x 10 -4 on its branching fraction is set at the 90% confidence level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-linear flow modes of identified particles in Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV

The pT-differential non-linear flow modes, v 4,22 , v 5,32 , v 6,33 and v 6,222 for π ± , K ± , K$^0_S$ , $p + \bar{p}, Λ + \bar{Λ}$ and ϕ-meson have been measured for the first time at $\sqrt{s_{NN}}$ = 5.02 TeV in Pb-Pb collisions with the ALICE detector at the Large Hadron Collider. The results were obtained with a multi-particle technique, correlating the identified hadrons with reference charged particles from a different pseudorapidity region. These non-linear observables probe the contribution from the second and third order initial spatial anisotropy coefficients to higher flow harmonics. All the characteristic features observed in previous p T -differential anisotropic flow measurements for various particle species are also present in the non-linear flow modes, i.e. increase of magnitude with increasing centrality percentile, mass ordering at low p T and particle type grouping in the intermediate p T range. Hydrodynamical calculations (iEBE-VISHNU) that use different initial conditions and values of shear and bulk viscosity to entropy density ratios are confronted with the data at low transverse momenta. These calculations exhibit a better agreement with the anisotropic flow coefficients than the non-linear flow modes. These observations indicate that non-linear flow modes can provide additional discriminatory power in the study of initial conditions as well as new stringent constraints to hydrodynamical calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The evidence of N = 16 shell closure and β -delayed neutron emission from 25 F

We measured the β -delayed neutron emission from 25 F for the first time at the Facility for Rare Isotope Beams (FRIB). Using combined neutron and γ -ray detector systems of the FRIB Decay Station Initiator (FDSi), we observed β -decay transitions populating neutron unbound states between 4.2 and 8 MeV in 25 Ne. The experimental results led to the revision of the β -decay half-life and β -delayed neutron-emission probability of 25 F. The β -decay strength distribution of 25 F extracted from the data agrees with the shell-model predictions using the USDB and SDPF-M effective interactions. This result indicates that the spherical neutron shell gap persists in 25 F and 25 Ne.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Constraints on axion-like dark matter from a SERF comagnetometer

Ultralight axion-like particles are well-motivated relics that might compose the cosmological dark matter and source anomalous time-dependent magnetic fields. We report on terrestrial bounds from the Noble And Alkali Spin Detectors for Ultralight Coherent darK matter (NASDUCK) collaboration on the coupling of axion-like particles to neutrons and protons. The detector uses nuclei of noble-gas and alkali-metal atoms and operates in the Spin-Exchange Relaxation-Free (SERF) regime, achieving high sensitivity to axion-like dark matter fields. Conducting a month-long search, we cover the mass range of 1.4 × 10 -12 eV/c 2 to 2 × 10 -10 eV/c 2 and provide limits which supersede robust astrophysical bounds, and improve upon previous terrestrial constraints by over two orders of magnitude for many masses within this range for protons, and up to two orders of magnitude for neutrons. These are the sole reliable terrestrial bounds reported on the coupling of protons with axion-like dark matter, covering an unexplored terrain in its parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

Evidence for B 0 → p Σ ¯ 0 π - at Belle

We search for the B 0 → p$\overline{Σ}$ 0 π - decay with $\overline{Σ}$ 0 → $\overline{Λ}$ γ, where the γ is not measured, using a data sample corresponding to an integrated luminosity of 711 fb -1 which contains 772 × 10 6 B$\overline{B}$ pairs, collected around the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e + e - collider. We measure for the first time the B 0 → p$\overline{Σ}$ 0 π - branching fraction to be $\mathscr{B}$(B 0 → p$\overline{Σ}$ 0 π - ) = $({1.17}_{-0.40}^{+0.43} (stat) ± 0.07(syst))$ X 10 -6 with a significance of 3.0σ. We simultaneously measure the branching fraction for the related channel B 0 → p$\overline{Λ}$ π - with much improved precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of η c ( 2 S ) → K + K − η

By analyzing ( 27.12 ± 0.14 ) × 10 8 ψ ( 3686 ) events accumulated with the BESIII detector, the decay η c ( 2 S ) → K + K − η is observed for the first time with a significance of 6.2 σ after considering systematic uncertainties. The product of the branching fractions of ψ ( 3686 ) → γ η c ( 2 S ) and η c ( 2 S ) → K + K − η is measured to be B ( ψ ( 3686 ) → γ η c ( 2 S ) ) × B ( η c ( 2 S ) → K + K − η ) = ( 2.39 ± 0.32 ± 0.34 ) × 10 − 6 , where the first uncertainty is statistical, and the second one is systematic. The branching fraction of η c ( 2 S ) → K + K − η is determined to be B ( η c ( 2 S ) → K + K − η ) = ( 3.42 ± 0.46 ± 0.48 ± 2.44 ) × 10 − 3 , where the third uncertainty is due to the branching fraction of ψ ( 3686 ) → γ η c ( 2 S ) . Using a recent BESIII measurement of B ( η c ( 2 S ) → K + K − π 0 ) , we also determine the ratio between the branching fractions of η c ( 2 S ) → K + K − η and η c ( 2 S ) → K + K − π 0 to be 1.49 ± 0.22 ± 0.25 , which is consistent with the previous result of at a comparable precision level. Published by the American Physical Society 2024

Ablikim, M.↗

Search for the e + e − → ϕ χ c 1 ( 3872 ) process at BESIII

Based on 368.5 p b − 1 of e + e − collision data collected at center-of-mass energies 4.914 and 4.946 GeV by the BESIII detector, the e + e − → ϕ χ c 1 ( 3872 ) process is searched for the first time. No significant signal is observed and the upper limits at the 90% confidence level on the product of the Born cross section σ ( e + e − → ϕ χ c 1 ( 3872 ) ) and the branching fraction B [ χ c 1 ( 3872 ) → π + π − J / ψ ] at 4.914 and 4.946 GeV are set to be 0.85 and 0.96 pb, respectively. These measurements provide useful information for the production of the χ c 1 ( 3872 ) at e + e − colliders and deepen our understanding about the nature of this particle. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Measurement of the branching fractions of the decays Λ c + → Λ K S 0 K + , Λ c + → Λ K S 0 π + , and Λ c + → Λ K * +

Studies are performed of the Cabibbo-favored decay Λ c + → Λ K S 0 K + and the singly Cabibbo-suppressed decay Λ c + → Λ K S 0 π + , based on a sample of e + e − collision data, corresponding to an integrated luminosity of 4.5 fb − 1 , accumulated at center-of-mass energies between 4599.53 MeV and 4698.82 MeV with the BESIII detector. The decay Λ c + → Λ K S 0 π + is observed for the first time. The branching fractions of Λ c + → Λ K S 0 K + and Λ c + → Λ K S 0 π + are measured to be ( 3.04 ± 0.30 ± 0.16 ) × 10 − 3 and ( 1.73 ± 0.27 ± 0.10 ) × 10 − 3 , respectively, where the first uncertainties are statistical and the second are systematic. These results correspond to the most precise measurement of these quantities for both decays. Evidence of a K * + contribution in the Λ c + → Λ K S 0 π + decay is found with a statistical significance of 4.71 σ . The branching fraction of Λ c + → Λ K * + is calculated under three possible interference scenarios, with the significance increasing to 5.03 σ when interference is taken into account. Published by the American Physical Society 2025

Ablikim, M.↗